• Title/Summary/Keyword: Waste incinerators

Search Result 97, Processing Time 0.025 seconds

A Study on Characteristics of Water Quality in Wastewater according to the Washing of Municipal Solid Waste Incinerator (MSWI) Ash

  • Byun, Mi-Young;Kim, Hyung-Seok;Ahn, Ji-Whan;Kim, Hwan
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.296-300
    • /
    • 2001
  • In order to recycle the incineration ash (bottom ash and fly ash) generated from the incineration of municipal waste for a cement material, salts as well as heavy metal should be removed by the stabilization treatment. Most of these heavy metal and over 80% of salts are removed by a washing as a pre-treatment. However, wastewater which is another pollutant is generated by a washing, then proper treatment should be developed. First the characteristics of incineration ashes collected from two domestic full-sized incinerators were investigated and removal rate of salts and heavy metals from them also studied. The wastewater quality was compared to the criteria of the regulation by analyzing the characteristics of generated wastewater during the washing of incineration ash as a condition of liquid/solid ratio. Also, we tried to used this experimental results for the basic data to develop proper processing technique of municipal waste.

  • PDF

Current treatment and disposal practices for medical wastes in Bujumbura, Burundi

  • Niyongabo, Edouard;Jang, Yong-Chul;Kang, Daeseok;Sung, Kijune
    • Environmental Engineering Research
    • /
    • v.24 no.2
    • /
    • pp.211-219
    • /
    • 2019
  • Since improper management practices of solid medical waste (SMW) could potentially result in serious health risks and environmental problems, it is very important to properly treat and dispose of the medical wastes. In this study, current practices of SMW management from storage to final disposal stage in 12 health care facilities (HCFs) of Burundi were investigated using the official government reports. The results showed that 75% and 92% of HCFs used uncovered wheelbarrows and trucks for on-site or off-site SMW transportation, respectively, indicating that most transportation equipment and waste workers are not safely protected. The results also showed that 92.8% of SMW (15,736.4 ton) from all 12 HCFs were inappropriately disposed of through uncontrolled land disposal and incineration. If pharmaceutical wastes and discarded medical plastics (29.5% of SMW) can be separated and treated properly, the treatment costs can be reduced and resource savings can be achieved. Raising awareness of healthcare workers and general public about potential health effects arising from improper SMW management, sufficient financial and human resources for the treatment facilities (especially incinerators), and effective regulations and guidelines for transportation and treatment of SWM are some of the major tasks for safe and sustainable medical waste management in Burundi.

Study on the heavy metal stabilization by dosing of chelate on the bottom ash (소각재에서의 용출억제제를 이용한 중금속 안정화에 관한 연구)

  • Jang, Hyeon-Jong;Kim, Seong-Jung
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.17 no.4
    • /
    • pp.81-90
    • /
    • 2009
  • About 35 domestic incinerators are being operated currently. There is waste management policy to reuse waste efficiently and reduce waste through incineration which include reuse, recycling and energy recovery. However, there is a critical social issue that some heavy metals(Cu, Pb) were found in bottom ash from incineration of waste. After incineration, bottom ash is treated with chemicals to prevent second pollution of heavy metals from bottom ash and increase efficiency of heavy metal stabilization.

PCDD/PCDFs Emission and Operating Conditions of Domestic MSW Incinerators (국내 도시 쓰레기 소각로에서의 운전조건과 다이옥신 배출량과의 상관관계에 관한 연구)

  • Yang, Won;Shin, Donghoon;Choi, Jinhwan;Choi, Sangmin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.12
    • /
    • pp.1755-1762
    • /
    • 1998
  • In order to minimize emission of polychlorinated dibenzo dioxins and polychlorinated dibenzo furans (PCDD/PCDFs) from municipal solid waste incinerators, it is important to maintain optimized operating conditions along with the system modification/improvement. Operating conditions of MSW incinerator make very complicated influence on formation of PCDD/PCDFs in each unit apparatus. For revealing these influences, concentrations of PCDD/PCDFs are measured from the stack and from the fly ash, while monitoring the plant operating conditions. The effects are grouped into 3 main categories, combustion conditions, de Novo synthesis effects, and adsorption/destruction effects in the flue gas treatment system. Interpretation of the results showed that de Novo synthesis effect, reformation by metalic catalyst, especially Cu in fly ash in the temperature range of $250{\sim}500^{\circ}C$, is found to influence most dominantly on the concentration of PCDD/PCDFs. A plausible mathmatical model for predicting concentration of PCDD/PCDFs is proposed, and discussed.

Chemical Analysis of Fly Ashes from Municipal Solid Waste Incinerators (생활폐기물 처리시설 배출 비산재의 조성분석)

  • Jang, Seong-Ki;Choi, Duk-Il;Lim, Chang-Ho;Lee, Jin-Sook
    • Analytical Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.215-221
    • /
    • 2000
  • Analysis of fly ashes from the MSW incinerators was carried out using XRF, ICP-MS and ICP-AES. It was found that the major elements of fly ash were Ca, K, Na, Si, Al, S, Cl and O by the XRF analysis. The XRD spectra showed that the fly ashes were mainly consisted with the chlorides, hydroxides, carbonates and also oxides of former elements. For the determination of minor elements such as Zn, Pb, Cu, Cr, and Cd, we used ICP-AES and ICP-MS after microwave digestion and the results were compared with the result of XRF.

  • PDF

Manufacturing Characteristics of Environmental-friendly Waste Ash Brick with Industrial By-Products (산업부산물을 이용한 친환경 연소재벽돌의 제조특성)

  • Kim, Han-Seok;Jung, Byung-Gil;Kim, Dae-Yong;Kang, Dong-Hyo;Jang, Seong-Ho
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.3
    • /
    • pp.226-234
    • /
    • 2009
  • The main objective of this study was to evaluate the effects on shape and size, compressive strength, water absorption and heavy metals leaching with various weight mixing ratios in waste ash brick products using waste recycling MSWI(Municipal Solid Waste Incinerator) bottom ash, steel slag and waste building material. The manufacturing processes for the waste ash brick consist of screening, mixing, conveyor transmission, compaction.forming, and curing steps of raw materials. The weight mixing ratios of steel slag around bottom ash were adjusted within the ranges of 10% to 30%. The reported results show that the width and thickness of the manufactured waste ash brick could be satisfied with $90{\pm}2mm\;and\;57{\pm}2mm$, respectively which are K.S. standards of products qualities. And in case of length, only 20-Ba50Ss30, 20-Ba60Wb20 and 20-Ba50Wb30 for the mixing ratios could be satisfied with $190{\pm}2mm$ that is K.S. standards of products quality. The compressive strength and water absorption for 20-Ba50Ss30 and 20-Ba70Wb10 were over $8N/mm^2$ and below 15% respectively that are K.S. standards of manufactured waste ash brick. The results of tests for the heavy metals leaching in the all manufactured waste ash bricks are also passed to the wastes management regulations. The cost analysis of 20-Ba50Ss30 is evaluated. The manufacturing cost is evaluated 34.3 won/brick with 8 hours and 20tons of raw material per day. Incinerators with problems in bottom ash disposal can therefore derive significant benefits from the application of waste ash brick production.

Demonstration of a Modular Electrostatic Precipitator to Control Particulate Emissions from a Small Municipal Waste Incinerator

  • Intra, Panich;Yawootti, Artit;Tippayawong, Nakorn
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.239-246
    • /
    • 2014
  • Incineration is conceptually sound as a waste treatment technology. There is, however, concern over its emissions when it is improperly designed and operated. An electrostatic precipitator is one of the most commonly used devices to control particulate emissions from boilers, incinerators and some other industrial processes. In this work, a modular electrostatic precipitator with sizing of $1m{\times}1m{\times}1m$ was developed for removal of particulate matter from the exhaust gases of a small waste incinerator. Its design was based on a simple wire-and-plate concept. The corona discharge wires were connected to a positive high-voltage pulse generator, while the collection plates were grounded. The high-voltage pulse generator was used to produce the corona discharge field between the individual discharge wire and the collection plate. The particulate-laden exhaust gas flow was directed across the corona discharge field. The charged particles were deflected outward and collected on the plate. The collection efficiency was evaluated as a mass loading ratio between the difference at the inlet and the outlet to the particulate loading at the inlet of the precipitator. The collection efficiency of this modular electrostatic precipitator design was approximately 80 %.