• Title/Summary/Keyword: Waste factor

Search Result 550, Processing Time 0.032 seconds

The degradation characteristics of waste cigarette filter in outdoor (실외에서 발생되는 폐 담배필터의 분해특성)

  • 김주학;윤오섭;이문수
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.21 no.2
    • /
    • pp.136-143
    • /
    • 1999
  • This study was conducted to evaluate the degradation characteristics of waste cigarette filters under 0, 5, 10, and 15cm in depth from soil surface by environmental conditions. Weather was the most important factor during degradation of waste cigarette filters in this study. Bulking of cellulose acetate filaments exposed on soil surface was observed after 2 months, but the form of filter was kept up after 12 months. The treated cigarette filters in soil landfill revealed a little different degradation pattern at each soil landfill depth, The sample in 5cm depth of soil was more degraded then other site. A fluffy appearance of cellulose acetate filaments in the control filter rods was also developed more strongly in soil landfill then on soil surface. From the observation of waste cigarette filters by scanning electron microscopy, much degradation of the fiber of waste cigarette filters could be ascertained in soil landfill. The weight of waste cigarette filters under 5cm from soil surface was reduced about 50%, and the tensile strength of the samples in soil surface and under 5cm from soil surface were reduced 66.0% and 92.4%, respectively. The microbial experiment date that the viable cell number in microbial population and cellulolytic microorganisms showed the maximum values under 5cm from soil surface, suggest that microorganisms in soil play an important roll in the degradation of acetate cigarette filters.

  • PDF

Considerations on Screening for the Input Data of the Biosphere Model in the Radioactive Waste Disposal Facility (방사성폐기물 처분시설에서 생태계 모델의 입력데이터 선정에 대한 고찰)

  • Mi-Seon Jeong;Dong-Kuk Park;Soo-Gin Kim;Kang-Il Jung
    • Journal of Radiation Industry
    • /
    • v.17 no.2
    • /
    • pp.209-217
    • /
    • 2023
  • The biosphere has important function in the safety assessment of a radioactive waste disposal facility. A biosphere model in the safety assessment needs various input data that contain significantly inherent uncertainties. This paper reviews the effects of the input data on the radiological impact assessment from main radionuclides such as 14C and 99Tc in the biosphere model. In addition, it is confirmed that the safety criteria is met, when the conservative input data for the intake rate, soil to plant concentration ratio, and distribution coefficients of the radionuclides are applied and probabilistic analysis are conducted in the biosphere model. Nevertheless, it is required to generate site-specific input data for the confidence building and reduce excessive conservatism in the biosphere model.

Assessment of Waste Management Practices , Source - reduction Programs and Related Tasks in Elementary School Foodservice in Seoul and Kyonggi Province Areas (서울.경기지역 초등학교 급식소의 쓰레기 감량화 프로그램 및 관리업무영역 규명)

  • Ryu, Gyeong;Gwak, Dong-Gyeong;Choe, Eun-Hui
    • Journal of the Korean Dietetic Association
    • /
    • v.7 no.4
    • /
    • pp.410-425
    • /
    • 2001
  • This study was designed to assess the waste management practices, source-reduction programs and related tasks in elementary school foodservice in Seoul. and Kyonggi Province Areas. A questionnaire mailed to 910 school foodservice managers in Seoul and Kyonggi province: a 202% (N=184) response rate was obtained. About 83.7% of school foodservice managers were responsible for managing solid waste. Most foodservice operations take the responsibility of food waste but not packaging wastes. The average disposal cost per month per person was about 19 won and income was about 35 won. Leftovers were mainly disposed with platewaste. Platewaste was reused for the livestook feed(68.0%), and some platewaste was composted(11.6%). Source reduction programs implemented in half of school foodservice operations were adjustment of portion size', checking the plate waste', 'working with classroom teachers on waste reduction campaign', 'providing information leaflet on food waste minimization', posting education materials, 'classroom instruction about food waste minimization', and 'improving cooking method. According to factor analysis based on importance rating. slid waste management activities of elementary school foodservice operations were divided to 7 dimensions such as communication and cooperation with others', 'employee training', 'product quality control, 'yield control', plate waste control', 'purchasing', and 'public relations'. As a result of Important-Performance Analysis(IPA), sine dimensions such as 'communication and cooperation with others' and 'plate waste control were identified in Focus Here' quardrant area which need more enhanced performance.

  • PDF

Analysis of Factors Affecting the Slope Stability of Uncontrolled Waste Landfill (비위생 폐기물 매립지 사면의 안정성에 관한 영향인자 분석)

  • Yoo, Han-Kyu;Choi, Bong-Hyuck
    • Journal of the Korean GEO-environmental Society
    • /
    • v.3 no.1
    • /
    • pp.5-12
    • /
    • 2002
  • The effects of ground water level, shear strength parameters of refuse, and geological condition of ground on the slope stability of uncontrolled waste landfill were studied. The Janbu method of slices based on the limit equilibrium method was used to calculate the minimum factor of safety with respect to slope stability of landfill. The analytical results showed that the factor of safety for a fully dried condition of landfill increased 2.4~2.8 times as great as that for a fully saturated condition of landfill. Under the condition of actual ground water level, the factor of safety linearly increased with increasing both cohesion and internal friction angle of refuse. Also, when the potential failure surface passed through the underlying layer, the factor of safety and shape of potential failure surface were found to depend on geological conditions of underlying layer.

  • PDF

RECYCLING OPTION SEARCH FOR A 600-MWE SODIUM-COOLED TRANSMUTATION FAST REACTOR

  • LEE, YONG KYO;KIM, MYUNG HYUN
    • Nuclear Engineering and Technology
    • /
    • v.47 no.1
    • /
    • pp.47-58
    • /
    • 2015
  • Four recycling scenarios involving pyroprocessing of spent fuel (SF) have been investigated for a 600-MWe transmutation sodium-cooled fast reactor (SFR), KALIMER. Performance evaluation was done with code system REBUS connected with TRANSX and TWODANT. Scenario Number 1 is the pyroprocessing of Canada deuterium uranium (CANDU) SF. Because the recycling of CANDU SF does not have any safety problems, the CANDU-Pyro-SFR system will be possible if the pyroprocessing capacity is large enough. Scenario Number 2 is a feasibility test of feed SF from a pressurized water reactor PWR. Thefsensitivity of cooling time before prior to pyro-processing was studied. As the cooling time sensitivity of cooling time before prior to pyro-processing was studied. As the cooling time increases, excess reactivity at the beginning of the equilibrium cycle (BOEC) decreases, thereby creating advantageous reactivity control and improving the transmutation performance of minor actinides. Scenario Number 3 is a case study for various levels of recovery factors of transuranic isotopes (TRUs). If long-lived fission products can be separated during pyroprocessing, the waste that is not recovered is classified as low- and intermediate-level waste, and it is sufficient to be disposed of in an underground site due to very low-heat-generation rate when the waste cooling time becomes >300 years at a TRU recovery factor of 99.9%. Scenario Number 4 is a case study for the recovery factor of rare earth (RE) isotopes. The RE isotope recovery factor should be lowered to ${\leq}20%$ in order to make sodium void reactivity less than <7$, which is the design limit of a metal fuel.

The impact of municipal waste disposal of heavy metals on environmental pollution: A case study for Tonekabon, Iran

  • Azizpour, Aziz;Azarafza, Mohammad;Akgun, Haluk
    • Advances in environmental research
    • /
    • v.9 no.3
    • /
    • pp.175-189
    • /
    • 2020
  • Municipal solid waste disposal is considered as one of the most important risks for environmental contamination which necessitates the development of strategies to reduce destructive consequences on the ecosystem as related especially to heavy metal accumulation. This study investigates heavy metal (i.e., As, Cd, Co, Cr, Cu, Mn, Ni, Pb, Zn) accumulation in the Tonekabon region, NW of Iran that is related to city waste disposal and evaluates the environmental impact in the Caspian Sea coastal region. For this purpose, after performing field studies and collecting 50 soil specimens from 5 sites of the study area, geochemical tests (i.e., inductively coupled plasma mass spectrometry, atomic absorption spectroscopy and x-ray fluorescence) were conducted on the soil specimens collected from the 5 sites (named as Sites A1, A2, A3, A4 and A5) and the results were used to estimate the pollution indices (i.e., geo-accumulation index, normalized enrichment factor, contamination factor, and pollution load index). The obtained indices were utilized to assess the eco-toxicological risk level in the landfill site which indicated that the city has been severely contaminated by Cu, Mn, Ni, Pb and Zn. These levels have been developed along the stream towards the nearshore areas indicating uptake of soil degradation. The heavy metal contamination was classified to range from unpolluted to highly polluted, which indicated serious heavy metal pollution in the study area as related to municipal solid waste disposal in Tonekabon.

Prediction of Polychlorinated-dibenzofurans (PCDFs) Formation in Municipal Waste Incinerator (도시소각로에서 Polychlorinated-dibenzofurans (PCDFs)의 생성 예측)

  • Ryu, Jae-Yong;Suh, Jeong-Min
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.6
    • /
    • pp.842-850
    • /
    • 2006
  • The role of chlorination reactions in the formation of polychlorinated dibenzofurans (PCDFs) in a municipal waste incinerator was assessed using a chlorination model for predicting PCDF isomer distributions. Complete distributions of PCDF congeners were obtained from a stoker-type municipal waste incinerator operated under 13 test conditions. Samples were collected from the flue gas prior to the gas cleaning system. While total PCDF yields varied by a factor of five to six, the distributions of congeners were similar. A chlorination model, dependent only on the observed distribution of monochlorinated isomers, was developed to predict the distributions of poly-chlorinated isomers formed by chlorination of dibenzofuran (DF). Agreement between predicted and measured PCDF isomer distributions was high for all homologues, supporting the hypothesis that DF chlorination can play an important role in the formation of PCDF byproducts.

Development of a Scaling Factor Prediction Method for Radioactive Composition in Low-level Radioactive Waste

  • Park, Jin-Beak;Lee, Kun-Jai
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05b
    • /
    • pp.833-838
    • /
    • 1995
  • This study presents a method to predict plant-specific and operational history dependent scaling factors. Realistic and detailed approaches are taken to find scaling factors at reactor coolant. This approach begins with fission product release mechanisms and fundamental release properties of fuel-source nuclide such as fission product and transuranic nuclide. Scaling factors at various waste streams are derived from the predicted reactor coolant scaling factors with the use of radionuclide retention and build up model. This model makes use of radioactive material balance within the radioactive waste processing systems. According to input parameters of plant operation history, scaling factors predicted at reactor coolant and waste streams are well brought out the effects of plant operation history.

  • PDF

A research on the actual condition on Dental Waste Treatment of dental hygienes (치과위생사의 감염성 폐기물 처리실태)

  • Park, Young-Nam;Min, Hee-Hong;Lee, Hye-Jin
    • Journal of Korean society of Dental Hygiene
    • /
    • v.6 no.1
    • /
    • pp.37-48
    • /
    • 2006
  • Dental personnels faced risks of infection in the clinic. For infection control, recognition and practice of dental personnels are important factor. This study was performed to investigate the recognition and practice of dental hygiene for infection control and infection waste control. A stratified convenience sample of dental hygienists in dental health-care settings. The major finding of the present study are as follows: 1. The existence of education about Standard Precaution and low of infection waste storage was higher dental hospital than dental clinic. 2. The degree of practice in the storage of dental wastes was low in absorbent cotton and body tissue exclude damage waste. And the degree of practice in the disposal of dental wastes was high in all three. 3. Practice in the storage of dental waste was higher dental hospital than dental clinic. 4. At the conclusion of this investigation, systematic refresher training of infection control should be prepared by campaign an various media, Dental health care workers should be encouraged to practice those action items from training. For successful implementation of infection control in every dental health-care settings, it is highly demanded as well that development of effective safe-guard tools, stategic support, and standardized action items against infection problems.

  • PDF

Decrease of the Hydrogen Sulfide($H_2S$) in the Produced Biogas by the Anaerobic Digestion (혐기성소화 시 발생되는 $H_2S$ 감소에 관한 연구)

  • Hong, Jong-Soon;Kim, Jae-Woo
    • Journal of environmental and Sanitary engineering
    • /
    • v.24 no.4
    • /
    • pp.80-89
    • /
    • 2009
  • In the organic waste, food waste is the most difficult controls. In the study, food waste was treatmented to removal only the dockage. To decrease the hydrogen sulfide($H_2S$) in the produced biogas, iron chloride put in the anaerobic digester. Respectively treatment quantity of the food waste, content of the methane($CH_4S$) gas in the biogas, produced gases quantity, put in the quantity of the Iron chloride, pH, TS, Alkalinity, VFA, Ammonia. The results obtained from the experiment are as follows: 1. The produced biogases quantity/the treatment quantity of the food waste was $83.82{\sim}129.41m^3/ton$. 2. The content of the hydrogen sulfide($H_2S$) in the produced biogas is below of the 500ppm. The iron chloride put in the anaerobic digester. 200~300kg of the iron chloride put in the anaerobic digester at the steady-state. 400~850kg of the iron chloride put in the anaerobic digester at the unsteady-state. 3. Factor of the operator was the pH: 7.7~8.4, content of mathane: 55~65%. 4. TS(total solid) of the digestor sludge was 17~20%, Alkalinity was 38,500~41,750ppm, VFA(Volatile Fatty Acids) was 2,800~2,420ppm, Ammonia was 4,300~3,650ppm.