• Title/Summary/Keyword: Waste clogging

Search Result 28, Processing Time 0.038 seconds

Filter Clogging of Leachate Collection and Removal System at Waste Landfill (폐기물 매립지 침출수 집.배수 시스템에서 필터 막힘에 관한 연구)

  • 고재학;이재영;노희정
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1999.10a
    • /
    • pp.77-80
    • /
    • 1999
  • In this study, to evaluate the performance of leachate collection and removal system, the clogging of geotextile filter was tested and simulated for HELP. As a result of clogging test, the all permeability of geotextiles were decreased rapidly in several day. Also, $Ca^{2+}$ and CODcr concentrations were decreased during test. In model simulation for HELP, Daily discharge volume was shown insignificant change with the filter clogging. however, this result may effect on increasing of the hydraulic gradient in waste layer.r.

  • PDF

A Study on the Optimal Design of Confluent Pipe for Waste Collection Piping System (쓰레기 자동집하시설 이송배관의 합류관 최적설계 연구)

  • Sung, Sun-Kyung;Park, Jun-Gil;Suh, Sang-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.5
    • /
    • pp.428-432
    • /
    • 2012
  • In the waste collection system, living waste is collected through the piping network. There are many confluent pipes in a piping network. These confluent pipes were often clogged up with waste. The optimal configuration of the confluent pipes has been defined by the design guide. However, nobody know how this design guide were determined. Therefore, in this paper, we found the design data for the confluent pipe configuration in order to avoid the waste clogging in a piping network. The distance between connected point on the confluent pipes should be longer than the previous design guide.

Comparison of ImmDbilization Techniques Using Phanerochaete chrysosporium for the Treatment of Pulp Waste Effluent (생물학적 펄프 파수처리를 위한 Phanerochaete chrnosporium의 고정화 방법 비교)

  • 유인상
    • KSBB Journal
    • /
    • v.8 no.4
    • /
    • pp.351-357
    • /
    • 1993
  • Three immobilization techniques and free cell system were tested to determine the most effective technique for the treatment of pulp waste effluent. The tests were conducted using Phanerochaete chrysosporium as a biocatalyst in a process designed to treat pulp waste effluent. The results show that Ca-alginate gel was the best immobilization material. The chosen material improved the stability and increased the removal efficiency of the system. The experiment using the chosen material was mom- bored for 400 hours with no significant changes in the state of the fungus. Common problems with other immobilization materials and free cell system were oxygen transfer resistance caused by air channelling and clogging in the bioreactor.

  • PDF

High-pressure Air Impulse Technique for Rehabilitating Well and Its Application to a Riverbank Filtration Site in Korea

  • Jeon, Hang-Tak;Hamm, Se-Yeong;Cheong, Jae-Yeol;Han, Suk-Jong;Yun, Sul-Min
    • Journal of Environmental Science International
    • /
    • v.28 no.10
    • /
    • pp.887-898
    • /
    • 2019
  • Rehabilitation work is required to increase well productivity, which decreases with the elapsed time of pumping owing to the clogging of the water well. Clogging causes not only a reduction in the well productivity but also a deterioration of the water quality. For unclogging and rehabilitating wells, several techniques are used such as brushing, air surging, surge blocks, and gas impulse. In this study, the high-pressure air impulse technique, which effectively and economically rehabilitates wells, was applied to a riverbank filtration site in Korea for the same objective. At most of the wells, the hydraulic parameters (transmissivity, storage coefficient, and specific capacity) were increased by the application of the high-pressure air impulse technique. The well loss change values also indicate an increase in the hydraulic parameters by the air impulse implementation. Thus, the high-pressure air impulse technique can be efficiently and economically applied to water and riverbank filtration wells for rehabilitating the decreased productivity.

Soil Improvement Effect of Waste Lime Sludge Using Prefabricated Vertical Drains (연직배수재를 이용한 폐석회 슬러지의 지반개량 효과)

  • Shin, Eun-Chul;Park, Jeong-Jun;Kim, Jong-In
    • Journal of the Korean GEO-environmental Society
    • /
    • v.6 no.2
    • /
    • pp.51-60
    • /
    • 2005
  • The disposal problem of waste lime which is a residual product of lime industry have caused a lots of arguments in the past few years. Further more, waste lime contains a high moisture content which causes the disposal of waste lime is a great difficulty. The purpose of this study is to investigate for the effective dewatering solutions by placing various prefabricated vertical drains. The moisture content and degree of consolidation, pore water pressure, changes of settlement, bearing capacity with various vertical drains in waste lime were analyzed. The laboratory test results indicate that PBD is 2 times higher than circular drain in coefficient of consolidation. Based on the laboratory test results, settlement, pore water pressure, and dewatering measurements are shown in similar tendency. It is considered that PBD can drain primitive pore water much efficiently. The picture of SEM shows that circular drain filter has a serious clogging problem in comparison with PBD. In conclusion, PBD holds a superiority in waste lime's ground improvement and dewatering pore water pressure from the waste lime sludge. Also, circular drain is desired for some modification in its filtering system.

  • PDF

A Study on the Manufacturing Process of Black Ink for Screen Printing by using Waste Ink (폐잉크를 이용한 스크린 인쇄용 블랙 잉크 제조에 관한 연구)

  • Kwon, Hee-Kyoung;Woo, Jin-Ho
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.28 no.2
    • /
    • pp.87-99
    • /
    • 2010
  • The ink which is left by sealed more than 6 months, it clogs head nozzle of machine due to precipitation and coagulation. In addition, if you stop printing about 3~4 hours in the middle of printing work, the head nozzles of printer could be naturally clogged. To prevent of this situation, worker should implement cleaning and checking head nozzle before hands. When the nozzle is clogged in the middle of work, running a head cleaning mode can clear the clogged nozzle. Yet, large amount of waste inks which are passed clogged nozzle will be remained after cleaning. It would be very nice that ink companies take the waste ink back by green marketing, but none of them are doing it currently. The purpose of this research is that making a black water-based recycle ink by waste inks which are left of nozzle clogging or passed expiration date. This recycle ink will improved working environment and reduce cost of disposing waste inks. Furthermore, it is very environment friendly and economical. It is called a recycle ink which is water-based black ink made by waste inks.

Phosphorus Removal from Synthetic Wastewater by Waste Oyster Shells (폐굴껍질에 의한 합성폐수 중의 인 제거)

  • 정경훈;정오진;최형일
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.3
    • /
    • pp.43-49
    • /
    • 2000
  • A laboratory experiments were performed to investigate the effects of several factors on the phosphorus removal by waste oyster shells. The waste oyster shells used in this experiments were crushed particle, calcined particle and extracted solution. A higher efficiencies of phosphorus removal were observed, when a particle size of crushed and calcined particle were smaller. The effluent concentration of phosphorus was around 1.6mg/ι in continuous column experiment which packed with crushed particle of waste oyster shell at the influent concentration of PO4-P of 10 mg/ι. But the clogging of column occurred with increasing of throughput volume of influent. The efficiency of phosphorus removal increased with increasing of dosage amount of crushed, calcined particle and extracted solution. When the calcined particle which contained only about 1/10~1/100 of crushed particle was used, the efficiency of phosphorus removal was correspondingly equivalent to the removal efficiency obtained from crushed particle. The efficiency of phosphorus removal by calcined particle after 9 runs repeated use was decreased about 21.5% as that of the first run. The removal efficiency of 100% could have been achieved at the HRT of 18 hours during the continuous treatment of phosphorus by the solution extracted from calcined particle.

  • PDF

Solids removal by foam fractionator in simulated seawater aquarium system

  • Lei Peng;Jo, Jae-yoon
    • Proceedings of the Korean Society of Fisheries Technology Conference
    • /
    • 2003.05a
    • /
    • pp.219-220
    • /
    • 2003
  • The success of recirculating system depends largely on the treatment efficiency of waste generated in the system. fine solids were suspected to be responsible for fish kill in a recirculating system. Clogging of biofilter may be induced by high solids concentration in recirculating systems. Also, the solids could generate more ammonia nitrogen and oxygen demand if not removed out of recirculating system as soon as possible (Weeks et al., 1992). (omitted)

  • PDF

Characteristics of Reinforced Drainage Geotextile for Waste Treatment System (폐기물매립지용 보강형배수재의 배수특성에 관한 연구)

  • Jeong, Ji-Hoon;Lee, Jai-Young;Lee, Myung-Ho
    • Journal of the Korean Geosynthetics Society
    • /
    • v.7 no.1
    • /
    • pp.31-37
    • /
    • 2008
  • The settlement occurring during landfill construction often causes a damage of drainage system. Clogging can reduce the hydraulic conductivity of the Leachate Collection and Drainage System, which results in the increase of leachate level within the landfill. Consequently, the insulation ability of leachate will be decreased. The main purpose of this project is to estimate a newly designed reinforced drainage geotextile (RDG) combining non-woven fabrics with geogrid for minimizing the destruction of drainage layer as well as evaluating RDG's application in the leachate collection and drainage system. Thus, the project observed the permittivity changes of RDG, and evaluated the drainage ability using RDG in the leachate collection and drainage system.

  • PDF

방사성환기설비 운전에 있어서의 부압변동 요인 및 대응 방안

  • 이강무;이범철;이영희;김태국;손종식;홍권표;김홍태
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.334-335
    • /
    • 2004
  • It is important that the contaminated air is not revealed to the outside of the facility. The inside of the facility should be classified into several zones according to the radioactivity and each zone should maintain tile differential negative pressure between the zones also. It is not easy to equilibrate the pressure during the operation. On the normal operation, the clogging of the HEPA filter and the opening of the doors/shutters influence very much. We could maintain the differential negative pressure between the zones by the constant watching and periodical replacement of the filters.

  • PDF