• 제목/요약/키워드: Waste Water Treatment System

검색결과 241건 처리시간 0.029초

오봉댐 유역의 폐탄광에 의한 오염특성과 감소방안 연구 (Investigation on the Contamination of the Vicinity of Abandoned Coal Mines Located Near the Obong Darn and Preventive Measures)

  • 박선환;장윤영;정정호;손정호;박석효
    • 환경영향평가
    • /
    • 제16권2호
    • /
    • pp.143-156
    • /
    • 2007
  • This study has researched the management status and the pollution level of water, soil, stream sediments of 11 abandoned coal mines out of a total of 12 within Obong-Dam area except Bukyung mine, which was submerged when constructing Obong-Dam, and selected areas which are in needs to have pollution control facilities in the first place. From the results of examination on the runoff at the waste rock pile and mineheads, the runoff from Sueun mine (pH, Fe, Al), Samwon mine (pH, Al), Wangdo mine (pH, Al), Mose mine (pH, Fe, Al) and Daeryeong mine (pH) exceeded the permissible discharge standards of the water quality, but the water at merging point with Obong-Dam after joined with Doma branch satisfied both Water Quality Standards and Drinking Water Quality Standards. In regard to groundwater contamination, it is found that areas where exceeded the Drinking Water Quality Standards are Wangdo mine (pH), Jangjae mine (pH, Zn), Daeryeong mine (pH) whereas all areas satisfied Soil Contamination Warning Standards of Soil Environmental Conservation Law. When comparing a research result on underwater sediments of branches of abandoned mines to the EPA Guidelines for classification of great lakes harbor sediments, Dongguk Gaerim (Fe), Jungwon mine (Fe), Daebo mine (Mn), Samwon mine (Mn) and Daeryeong mine (Mn) showed mid-level of contamination, whereas Sueun (Fe, Mn), Daebo mine (Fe), Woosung mine (Fe, Mn), Wangdo mine (Fe, Mn), Mose mine (Fe) and Daeryeong mine (Fe) showed high-level of contamination. In addition, contamination levels of underwater sediments in Wangsan and Doma branch where abandoned mine's branches merge together, Wangsan branch showed no contamination at all whereas Doma branch shows mid-level of contamination which reflect the Doma branch is affected by waste rock pile and minehead runoff of the abandoned mines in the Doma branch area. It is concluded that Mose mine and Sueun mine required treatment of acid mine drainage. and Wangdo, Jungwon, and Samwon mines were in need of mine tailing and erosion control work. The Samwon mine additionally required a control system for closed minehead runoff. Although the Samwon mine reached a high concentration of Al, Mn $Ca^{2+}$, $SO{_4}^{2-}$ in the runoff, the levels decreased after it was combined with a tributary. It has been concluded that after further monitoring of the cause of pollution, a preventive measure system may be needed to be built.

동전기제염장치에서 발생한 폐액의 재사용을 위한 개선된 처리기술 (Improved Treatment Technique for the Reuse of Waste Solution Generated from a Electrokinetic Decontamination System)

  • 김완석;김승수;김계남;박욱량;문제권
    • 방사성폐기물학회지
    • /
    • 제12권1호
    • /
    • pp.1-6
    • /
    • 2014
  • 우라늄으로 오염된 토양을 복원하기 위해 실규모의 동전기제염장치로 제염하는 과정에서 많은 산폐액이 발생한다. 발생한 산폐액에 CaO를 가해 우라늄수산화물을 침전시켜 여과한 다음, 방사성 폐액을 줄이기 위하여 이 용액을 재사용하였다. 그러나 이 용액을 동전기에 재사용할 경우, 높은 농도의 칼슘 때문에 양극실에서 음극실로 용액이동 속도가 감소하여 여과포의 약화, 전선 부식, 음극면에 산화물 부착 등의 문제점이 발생하였다. 이 문제들을 해결하기 위하여 재생액에 황산을 넣어 $CaSO_4$로 침전시켜 칼슘을 제거하였다. 칼슘이 제거된 재생액을 사용하여 소형 동전기 장치에서 20 일간 토양제염 실험을 수행한 결과는 세척후 토양내 우라늄 잔류 농도가 0.35 Bq/g로 감소하였으며, 이는 증류수 제염한 결과와 유사하게 나타났다.

양식장 배출수 수질관리를 위한 용존공기부상 공법의 운전 인자 영향 분석 (Analysis of the operating factors of dissolved air flotation (DAF) process for effluent quality improvement from aquaculture rearing tank)

  • 기재홍;김형준;이주영;한무영;강희웅
    • 상하수도학회지
    • /
    • 제26권1호
    • /
    • pp.107-113
    • /
    • 2012
  • Pollutants in aquaculture system effluent mostly originated from solid wastes including uneaten feed and excreta of cultured species. In this research, DAF(Dissolved Air Flotation) unit is suggested as an integrated solid control unit especially as a form of IIBG(Inline Injection Bubble Generation) process in aquaculture system. Solid removal performance of DAF unit was examined under various operation and salinity conditions with turbidity and suspended solid. Solid waste removal efficiencies were found to be affected by operation conditions including saturator pressure, recycle ratio, coagulant concentration. Solid removal efficiency was higher under higher saturator pressure and recycle ratio under which condition larger number of bubbles is generated. Coagulant is thought to have important role in creating bubble-particle aggregate by showing better removal efficiency with higher concentration. However higher saline water showed less effectiveness in removing solids by DAF(IIBG). Application of DAF(IIBG) process also showed additional effect in phosphate removal and DO(Dissolved Oxygen) supply. Phosphate existed in polluted water was removed up to 46% after treatment, which is thought to attribute to aluminium phosphate precipitation. And DO concentration was found to increase over 50% of initial saturation concentration after the injection of micro-bubbles. Through experiments on solid removal from aquaculture effluent, DAF(IIBG) process is estimated to be effective solid control method. This property can help aquaculture system being installed and operated simply and effectively.

1차 화학 처리된 닭 가공 폐수의 생물학적 처리에 의한 유기물 및 질소제거에 관한 연구 (Study on Organic Matter and Nitrogen Removal by Biological Treatment of Wastewater Processing of Chicken, which is the Primary Chemical Processing)

  • 한형석;최용구;송진호;김호
    • 한국수자원학회논문집
    • /
    • 제47권3호
    • /
    • pp.247-256
    • /
    • 2014
  • 도계량을 현재의 2배까지 증가시킬 예정인 닭 가공 업체인 A사의 생물학적 처리조를 대상으로 하여 처리효율을 2배까지 높이는 방안을 모색하였다. 이를 위해 MLSS 농도가 증가할 경우 이에 따른 유기물 및 질소 제거 효율증가에 대한 근거를 확보하고자 연구를 진행하였다. 연구는 닭 가공 폐수를 1차 화학 처리한 가압부상처리수를 대상으로 진행되었으며 SBR 형태로 진행되어 호기조 상태 25시간 운전 후, 무산소조 상태 5시간으로 운전되었다. MLSS 12,700mg/L로 진행된 실험 결과 호기조 상태 25시간 이내에 질산화가 완벽하게 일어났으며 C/N비 3 : 1 이상 실험군에서의 탈질효율도 90%를 초과하였다. 후에 진행된MLSS 농도대비 유기물 및 질소제거 효율비교에서는 MLSS 농도를 5,600에서 12,700mg/L까지 변화시켰으며 MLSS 농도 10,800mg/L 실험군에서 유기물과 총 질소 농도 모두 배출허용기준치를 만족하는 결과를 보였다.

Flexo 인쇄폐수의 처리 및 재활용에 관한 연구 (A study on the flexo printing wastewater treatment and recycling)

  • 전용보;허훈;조계민;배우근
    • 청정기술
    • /
    • 제9권3호
    • /
    • pp.107-113
    • /
    • 2003
  • 인쇄 및 출판 산업의 발전으로 인쇄공정에서는 다량의 유독성 폐기물 및 폐수등이 발생한다. 인쇄공정에서 필수적으로 사용되는 각종 환경오염물질에 대한 규제가 강화되고 있기에 환경친화형 청정기술 개발이 필요하며 또한 인쇄업계의 적극적인 환경대응책이 필요한 시점이다. 따라서 본 연구에서는 인쇄폐수에 대한 정밀여과, 한외여과, 역삼투 등의 막분리 시스템의 효용성을 검토하고 공정을 개선할 수 있는 기본 자료를 도출하여 처리수의 재이용 방안을 모색하고 공정의 최적화를 도모하고자 하였다. 그 결과 U/F System의 운전압력은 $2kg/cm^2$이 적당하였으며, U/F처리수는 탁도 3NTU 이하로서 인쇄공정 현장에서 기계세척수로 사용가능할 것으로 판단되었다.

  • PDF

과학적인 수질관리를 위한 오염총량관리제도의 추진 방안 (Policy Directions of Total Maximum Daily Loads for the Scientific Management of Water Quality)

  • 박석순;나유미;나은혜
    • 환경영향평가
    • /
    • 제10권2호
    • /
    • pp.157-165
    • /
    • 2001
  • This paper presents the policy directions of total maximum daily loads(TMDL), which was recently adopted in Korea, for scientific management of water quality. The basic principles of water quality management are also discussed in this paper, along with the TMDL policy in United States as well as the previous policy in Korea. We discussed several unreasonable points out of the previous approaches, such as regulation of all point sources with equal standards, negligence of an assimilative capacity of the receiving water, and emphasis only on drinking water supply, etc.. For successful applications of the TMDL policy in Korea, the following directions are suggested: 1) the unit drainage basin for each TMDL application should be given, 2) the water body where the water quality standards should be maintained, needs to be guided, 3) the water quality parameters of TMDL should be given, 4) the technical guidances should be given for applications of water quality models, and 5) the seasonal TMDL would be allowed. In order to maximize the benefits of the TMDL policy, the local governments would need to implement the following strategies: 1) the increment of an assimilative capacity of the receiving water, 2) the effective controls of the non-point source pollution, 3) the advanced treatment of the point sources, 4) application of system optimization techniques along with effluent trade, and 5) utilization of watershed management systems.

  • PDF

폐가스 가습조(유동상호기 및 무산소조)를 포함한 바이오필터공정을 이용한 악취폐가스의 처리 (Treatment of Malodorous Waste Air by a Biofilter Process Equipped with a Humidifier Composed of Fluidized Aerobic and Anoxic Reactor)

  • 임광희
    • Korean Chemical Engineering Research
    • /
    • 제56권1호
    • /
    • pp.85-95
    • /
    • 2018
  • 본 연구에서는 폐가스 가습조(유동상호기 및 무산소조)를 포함한 바이오필터공정으로 이루어진 바이오필터시스템을 구축하여, 돈사 및 계사 설비, 퇴비공장 또는 공공시설에서 발생되는 황화수소, 암모니아 및 휘발성 유기화합물을 포함한 악취폐가스에 대한 처리효율을 제고하고 적정 작업조건을 구축하였다. 복합 악취폐가스 처리실험에서, 암모니아 부하의 경우 폐가스 가습조에서 약 75%가 제거되고, 후 공정인 바이오필터에서 20%이상 제거되었다. 톨루엔 부하의 경우 폐가스 가습조에서 약 20%가 제거되고, 후공정인 바이오필터에서 70% 이상 제거되었다. 따라서 물에 용해도가 높은 암모니아의 경우에는 폐가스 가습조에서 주로 제거되었고, 용해도가 낮은 톨루엔의 경우는 바이오필터에서 주로 제거되었다. 한편 황화수소는 폐가스 가습조에서 거의 흡수되어 바이오필터에서 검출되지 않았다. 황화수소 및 톨루엔의 공급을 중단하였을 때에, 암모니아 부하는 폐가스 가습조에서 약 65%가 제거되고 후 공정인 바이오필터에서 나머지 약 35% 정도가 제거되어, 거의 100%의 암모니아 부하가 제거되었다. 폐가스 가습조에서는 암모니아 외에 톨루엔 및 황화수소의 부하가 추가된 복합 악취폐가스의 경우보다 약 10% 더 적게 암모니아가 제거되었는데, 이것은 탈질에 필요한 톨루엔과 같은 유기화합물의 공급 중단에 기인하였다. 바이오필터시스템의 feed가, 1)복합 악취폐가스일 때, 2)암모니아 폐가스일 때에; 기존 폐가스 가습조 용수에 yeast extract를 보충한 경우 또는 yeast extract를 첨가하지 않고 탄소원으로 glucose를 첨가한 경우, 각각의 경우에 폐가스 가습조에서 흡수되는 암모니아질소 흡수율은, 각각 약 0.28 mg/min, 약 0.23 mg/min 및 약 0.27 mg/min으로 산출되었다. 한편 각각의 무산소조에서 탈질율은 0.42 mg/min, 0.55 mg/min, 및 약 0.27 mg/min이었다. 또한 폐가스 가습조(유동상 호기조)의 bubble column 모델링에서 유동상 호기조 단위부피당 bubble의 비표면적(a)과 향상된 물질전달계수(E $K_y$)의 곱의 값은 0.12/hr로 평가되었다.

FNN 성능개선을 위한 클러스터링기법의 적용 (Adaptation of Clustering Method to FNN for Performance Improvement)

  • 최재호;박춘성;오성권;안태천
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 1997년도 추계학술대회 학술발표 논문집
    • /
    • pp.135-138
    • /
    • 1997
  • In this paper, we proposed effective modeling method to nonlinear complex system. Fuzzy Neural Network(FNN) was used as basic model. FNN was fused of Fuzzy Inference which has linguistic property and Neural Network which has learning ability and high tolerence level. This paper, we used FNN which was proposed by Yamakawa. The FNN used Simple Inference as fuzzy inference method and Error Back Propagation Algorithm as learning rule. This structure has better property than other structure at learning speed and convergence ability. But it has difficulty at definition of membership function. We used Hard c-Mean method to overcome this difficulty. To evaluate proposed method. We applied the proposed method to waste water treatment process. We obtained better performance than conventional model.

  • PDF

Nonlinear self-tuning regulator for neutralization of weak acid streams by a strong base

  • Lee, Sang-Deuk;Lee, Ji-Tae;Park, Sun-Won
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1989년도 한국자동제어학술회의논문집; Seoul, Korea; 27-28 Oct. 1989
    • /
    • pp.786-789
    • /
    • 1989
  • A nonlinear self-tuning regulator for a neutralization process of a weak acid and strong base system is proposed. Rearranging the state equation of the process model, we first obtain equations which are linear for a manipulated variable or unknown parameters. Then to these equations we apply the standard procedure used in designing linear self-tuning regulators. Simulation results show that the regulator provides very good performances for various realistic situations and traces variations of the unknown parameters. Since computations are simple and additional measurements except the effluent pH value are only flow rates of influent streams, it can be easily applied to real processes such as a waste water treatment process.

  • PDF

RESEARCH PAPERS : REMOVAL EFFICIENCY OF THE POLLUTANTS BY MULTILAYERED METAL TREATED CARBON FILTER

  • Oh, Won-Chun;Lee, Ho-Jin;Bae, Jang-Soon
    • Environmental Engineering Research
    • /
    • 제9권5호
    • /
    • pp.193-200
    • /
    • 2004
  • A study of the treatment of piggery wastes using a multilayered metal-activated carbon system followed by carbon bed filtration was carried out at bench scale. From the physicochemical properties obtained from samples treated with aqueous solutions containing metallic ions such as Ag$^+$, Cu$^{2+}$, Na$^{-}$, K$^+$ and Mn$^{2+}$, main inspections are subjected to isothem shape, pore distribution with micropore, SEM and EDX. Multilayered metal-activated carbons were contacted to waste water to inwestigate the simultaneous catalytic effect for the COD, BOD, T-N and T-P removal. From these removal performance was achieved. The high efficiency of the multilayered metal-activated carbon bed, satisfactory removal performance was achieved. The high efficiency of the multilayered metal-activated carbon bed was derermined by the properties of this material for trapping, catalytic effect and adsorption of organic solid particles.