• Title/Summary/Keyword: Waste Removal

Search Result 1,012, Processing Time 0.025 seconds

Removal Efficiency of Organic Iodide on Silver Ion-Exchanged Zeolite and TEDA-AC at High Temperature Process (고온공정에서 은교환 제올라이트 및 TEDA 첨착활성탄의 유기요오드 제거성능)

  • 최병선;박근일;윤주현;김성훈;배윤영;지성균;양호연;유승곤
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.207-214
    • /
    • 2003
  • Removal efficiency of methyl iodide at high temperature process by TEDA-impregnated activated carbon used for radioiodine retention in nuclear facility was experimentally compared with that of silver ion-exchanged synthetic zeolite(AgX), In temperature ranges of$30^{\circ}C$ to $400^{\circ}C$, adsorption capacity of un-impregnated carbon was sharply decreased, but TEDA-impregnated carbon showed similar values of adsorption capacity of AgX even around $100^{\circ}C$. Especially, loading amount of methyl iodide on TEDA carbon up to$250^{\circ}C$ represented higher values compared to un-impregnated carbon. Breakthrough curves of methyl iodide in fixed bed packed with AgX and TEDA-impregnated carbon at high temperature was compared. Removal mechanism of methyl iodide on AgX was proposed, based on analysis of by-product gas generated from adsorption reaction.

  • PDF

Decoloration of Polycyclic Aromatic Dyes by Mushroom Fungi (버섯균에 의한 염료의 탈색)

  • Sancheti, Sandesh;Sancheti, Shruti;Seo, Sung-Yum
    • The Korean Journal of Mycology
    • /
    • v.37 no.1
    • /
    • pp.73-79
    • /
    • 2009
  • As waste-water disposal plants and oxidative biodegradation for the removal of waste polyaromatic dyes are proved to be ineffective due to the chemical stability of dyes, we studied various strains of mushroom fungi for the removal of these dyes. 100 fungi were isolated from the mushroom samples of 230 species collected in Korea. The growth medium containing a dye (Bromophenol Blue, Congo Red, or Methylene Blue) was inoculated to 10% and incubated for 7 days without shaking. The six strains which removed dyes effectively were selected for further studies with respect to removal of polycyclic aromatic dyes. For all strains, the rate of decoloration of dyes was increasing with Methylene Blue, Bromophenol Blue and Congo Red. The rate of decoloration was higher with stationary culture than with shaking culture. Adsorption of the dyes was the highest with Congo Red.

Destruction and Removal of PCBs in Waste Transformer Oil by a Chemical Dechlorination Process

  • Ryoo, Keon-Sang;Byun, Sang-Hyuk;Choi, Jong-Ha;Hong, Yong-Pyo;Ryu, Young-Tae;Song, Jae-Seol;Lee, Dong-Suk;Lee, Hwa-Sung
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.4
    • /
    • pp.520-528
    • /
    • 2007
  • A practical and efficient disposal of PCBs (polychlorinated biphenyls) in waste transformer oil by a chemical dechlorination process has been reported. The transformer oil containing commercial PCB mixtures (Aroclor 1242, 1254 and 1260) was treated by the required amounts of PEG 600 (polyethylene glycol 600), potassium hydroxide (KOH) and aluminum (Al), along with different reaction temperatures and times. The reaction of PEG with PCBs under basic condition produces arylpolyglycols, the products of nucleophilic aromatic substitution. The relative efficiencies of PCB treatment process were assessed in terms of destruction and removal efficiency (DRE, %). Under the experimental conditions of PEG600/KOH/Al/100 oC/2hr, average DRE of PCBs was approximately 78%, showing completely removal of PCBs containing 7-9 chlorines on two rings of biphenyl which appear later than PCB no. 183 (2,2',3,4,4',5',6-heptaCB) in retention time of GC/ECD. However, when increasing the reaction temperature and time to 150 oC and 240 min, average DRE of PCBs including the most toxic PCBs (PCB no. 77, 105, 118, 123 and 169) in PCB family reached 99.99% or better, with the exception of PCB no. 5 and 8 (2,3-diCB and 2,4'-diCB). In studying the reaction of PEG with PCBs, it confirmed that the process led to less chlorinated PCBs through a stepwise process with the successive elimination of chlorines. The process also permits complete recovery of treated transformer oil through simple segregating procedures.

Ions Removal of Contaminated Water with Radioactive Ions by Reverse Osmosis Membrane Process (방사성이온으로 오염된 물의 역삼투막공정을 이용한 이온제거)

  • Shin, Do Hyoung;Cheong, Seong Ihl;Rhim, Ji Won
    • Membrane Journal
    • /
    • v.26 no.5
    • /
    • pp.401-406
    • /
    • 2016
  • In this study, we have investigated the removal of the low level radioactive ions of Cs and I in water by the reverse osmosis (RO) process. The two RO modules produced in domestic region and the waste RO module after the cleaning process were selected. Then we compared removal performance of both Cs and I. The experiments are conducted by varying the concentration of feed, the pressure. As a results, it was confirmed that all three modules are higher I decontamination factor than Cs. And particularly, for the cleaned RO module, its decontamination factor of I was 1140. Since the results at low pressure condition were better than that at high pressure conditions, the use of the direct installation of RO modules on the tap water might be possible. In addition, it was confirmed that the waste RO module after cleaning process using EDTA, SBS and NaOH, increased the decontamination performance better than before cleaning, in particular, the recovery ratio after cleaning was 6.3% higher.

Application of Non-Thermal Plasma for the Simultaneous Removal of Odor and Sludge (무기악취와 슬러지 동시처리를 위한 저온플라즈마의 적용)

  • Hwang, Hyun-Jung;Ann, Hae-Young;Shin, Seung-Kyu;Song, Ji-Hyeon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.1
    • /
    • pp.85-92
    • /
    • 2010
  • In this study, odorous compounds emitted from various wastewater treatment were treated with using the non-thermal plasma reaction, and the effluent gas from the plasma reactor was introduced to a waste sludge reactor to achieve simultaneous sludge reduction. Hydrogen sulfide, the model odorous compound, was removed at 70% using the plasma reaction, and greater than 99% removal efficiency was observed when treated by the sludge reactor. In addition, the sludge reactor showed a high efficiency of ozone removal. As ozone reacted with sludge, oxidation with organic matters took place, and total COD decreased by 50~60% and soluble COD increased gradually. As a result, the integrated process consisting of the non-thermal plasma and the sludge reactor can be successfully applied for the simultaneous treatment of malodorous gas and waste sludge.

Removal of Chlorine from Fly Ash in Municipal Solid Waste Incineration Ash by Water Washing (수세에 의한 생활폐기물 소각재 중 비산재로부터 염소성분의 제거)

  • 안지환;한기천;김형석
    • Resources Recycling
    • /
    • v.10 no.5
    • /
    • pp.36-43
    • /
    • 2001
  • The chlorine component in fly ash from municipal solid waste incineration ash was removed by water washing for the purpose of recycling fly ash as a raw material of ordinary portland cement. The samples were a different kind of 리y ashes using $Ca(OH)_2$and NaOH as media of wet scrubber for flue gas cleaning. The content of soluble salts of fly ash using $Ca(OH)_2$and NaOH was 32.8%, 50.1% and the content of chlorine component, 22.9% and 26.0% respectively, which was KCl, NaCl, CaC1OH mainly. When each fly ash was washed using water under conditions of a agitation speed of 300 rpm, a liquid to solid ratio of 10, most soluble salts in fly ash were dissolved within 30 minutes and the content of chlorine component in ash was diminished to the content of 4.4%, 2.O% at $20^{\circ}C$ and 1.7%, 0.8% at $50^{\circ}C$ respectively. And the main compound of residual chlorine component in ash after water washing was friedel`s salt ($3CaO.A1_2$$O_3$.$CaCl_2$.$10H2$O). From analysis results of water quality for wastewater by water washing, the components exceeding discharged wastewater standard were only Pb and Cd. But As pH was controlled to 10 with addition of $CO_2$(g) or $Na_2$$_CO3$in water, the concentration of heavy metals such as Pb and Cd was also under discharged wastewater standard.

  • PDF

Effect of TS Concentration on Anaerobic Digestion using Supernatant of Food Waste (음식물류 폐기물 혐기성 소화에 있어서 TS농도 영향)

  • Jang, Eun-sung;Ruy, Seung-hun;Phae, Chae-gun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.15 no.2
    • /
    • pp.118-127
    • /
    • 2007
  • This study investigated the effect of varying TS concentration levels using supernatant of food waste. The experiment was performed at varying TS concentration levels ranging from 5% to 10% by a $35^{\circ}C$-mesophilic digestion reactor, dual digestion system with acid and methane fermenters combined. As a result, removal efficiency and stabilization were observed at TS concentration of 7~8%, But the removal efficiency notably decreased at 8% or higher TS level. At a stabilized phase of the reactor, more than $0.3m^3/kg{\cdot}vs$ gas was produced, with phenomena such as salt accumulation and increase of pH level being unnoticed. These results indicate that the increase of anaerobic digestion of food waste supernatant TS content has an effect on reaction and that it is necessary to control and operate concentration within 8%, given that the effect is stronger at 8% or higher.

  • PDF

Design Study of Fuel Supply System for 5MW-class Bio Gasturbine by Using Food Waste Water (5MW급 바이오 가스터빈용 전처리시스템 설계연구)

  • Hur, Kwang-Beom;Park, Jung-Keuk;Yun, Eun-Young;Lee, Jung-Bin
    • New & Renewable Energy
    • /
    • v.7 no.2
    • /
    • pp.10-17
    • /
    • 2011
  • Korea is the 11th largest energy consumption country and 96% of its total energy consumption depends on imports from overseas. Therefore it is a very important task to secure renewable energy sources which can reduce both the carbon-dioxide emission and dependency on overseas energy imports. Among the various renewable energy sources, organic wastes are important sources. In Korea, 113 million toe of methane is generated from organic wastes annually, but only 3.7% is effectively used for energy conversion. Thus, it is very important to make better use of organic wastes, especially for power generation. The goals of this project are to develope the fuel supplying system of Bio Gasturbine (GT) for 5MW-class co-generation system. The fuel supplying system mainly consists of $H_2S$ removal system, Bio Gas compression system, Siloxane removal system and moisture separating systems. The fuel requirement of 5MW-class GT is at around 60% of $CH_4$, $H_2S$ (<30 ppm), Siloxane(<10 mg/$nm^3$) and supply pressure (> 25 bar) from biogas compressor. Main mechnical charateristics of Bio Gasturbine system have the specific performance; 1) high speed turbine speed (12,840 rpm) 2) very clean emmission NOx (<50 ppm) 3) high efficiency of energy conversion rate. This paper focuses on the development of design technology for food waste biogas pretreatment system for 5MW-class biogas turbine. The study also has the plan to replace the fuel of gas turbine and other distributed power systems. As the increase of bioenergy, this system help to contribute to spread more New & Renewable Energy and the establishment of Renewable Portfolio Standards (RPS) for Korea.

Recovery of Zirconium and Removal of Uranium from Alloy Waste by Chloride Volatilization Method

  • Sato, Nobuaki;Minami, Ryosuke;Fujino, Takeo;Matsuda, Kenji
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.179-182
    • /
    • 2001
  • The chloride volatilization method for the recovery of zirconium and removal of uranium from zirconium containing metallic wastes formed in spent fuel reprocessing was studied using the simulated alloy waste, i.e. the mixture of Zr foil and UO$_2$/U$_3$O$_{8}$ powder. When the simulated waste was heated to react with chlorine gas at 350- l00$0^{\circ}C$, the zirconium metal changed to volatile ZrCl$_4$showing high volatility ratio (Vzr) of 99%. The amount of volatilized uranium increases at higher temperatures causing lowering of decontamination factor (DF) of uranium. This is thought to be caused by the chlorination of UO$_2$ with ZrCl$_4$vapor. The highest DF value of 12.5 was obtained when the reaction temperature was 35$0^{\circ}C$. Addition of 10 vol.% oxygen gas into chlorine gas was effective for suppressing the volatilization of uranium, while the volatilization ratio of zirconium was decreased to 68% with the addition of 20 vol.% oxygen. In the case of the mixture of Zr foil and U$_3$O$_{8}$, the V value of uranium showed minimum (44%) at 40$0^{\circ}C$ with chlorine gas giving the highest DF value 24.3. When the 10 vol.% oxygen was added to chlorine gas, the V value of zirconium decreased to 82% at $600^{\circ}C$, but almost all the uranium volatilized (Vu=99%), which may be caused by the formation of volatile uranium chlorides under oxidative atmosphere.ere.

  • PDF

Packing Tower Design of Waste Oyster Shells using Bohart-Adams Equation (Bohart-Adams 식을 이용한 폐굴껍질 충진탑의 설계)

  • Kim, Eun-Ho;Kim, Seok-Taek;Kim, Il-Bae;Kim, Hyeong-Seok
    • Korean Journal of Environmental Agriculture
    • /
    • v.18 no.3
    • /
    • pp.209-214
    • /
    • 1999
  • Objective of the research is to estimate neutralization capacity and to determine practical running parameters required in packing tower design of waste oyster shells using Bohart-Adams equation. It is expected that waste oyster shells are able to be recycled for removal of heavy metals through neutralization of plating wastewater because those contain approximate 93% $CaCO_3$. By applying the results of the continuous experiment to Bohart-Adams equation, service time decreases in the order of Cr>Fe>Cu, while removal efficiencies of metals become less in the order of Fe>Cr>Cu.

  • PDF