• Title/Summary/Keyword: Waste Loads

Search Result 92, Processing Time 0.022 seconds

Mutual Accreditation of Certification Systems for Apartment Housing - Focused on Green Building Certification Criteria and Good Housing Certification System - (공동주택 관련 인증제도 간 상호 인정 방안 - 친환경건축물인증제도와 주택성능등급표시제도를 중심으로 -)

  • Ahn, Sun Ju;Song, Sang Hoon
    • KIEAE Journal
    • /
    • v.11 no.2
    • /
    • pp.35-44
    • /
    • 2011
  • Many countries have run their own certification systems in order to reduce the environmental loads from buildings. Domestically, various systems are applied according to building types from Building Energy Efficiency Rating System since 2001 to Green Home Construction Standard and Performance since 2009. However, these systems provide the applicants with confusion and waste by exposing them to several systems simultaneously, some of which are mandatory. Therefore, this study aims to ensure the flexibility among those systems and eliminate the possible waste by suggesting mutual accreditation method of evaluation results. To achieve this purpose, firstly, the thirteen similar evaluation items are identified between Housing Performance Grading Indication System and Green Building Rating System. Then, the mutual accreditation method is developed by comparing detailed evaluation criteria and credits for those thirteen items.

A Study on the Environmental Impact of Biological Production Facilities (대규모 생물생산 시설의 환경 영향 연구)

  • 남상운
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.38 no.5
    • /
    • pp.106-115
    • /
    • 1996
  • This study was carried out to provide fundamental data for reuse of resources and prevention of environmental pollution Actual states of environmental pollution by biological production facilities were investigated. Various pollution loads and quantity of wastes from greenhouse and animal housings estimated. In greenhouse contents of investigation were wastes of plastic cover, noise of heater and fan, air pollutant of heater, and wastes of soilless culture system, etc. In animal housings, those were actual state of livestock waste treatment and reuse, pollutant mass unit discharge, noise pollution, and malodorant, etc. The main pollutants discharged from greenhouses were wastes of plastic cover, rockwool, and waste fluid of nutrient solution. Developments of waste disposal methods for plastic cover and rockwool are required. And recycle technique of nutrient solution for soilless culture should be developed and propagated. With the buildup of legal control, pollutant mass discharged from livestock wastes are, on the decrease. The other side, reuse of livestock excreta increased. Most animal housings are located near the dwelling house. Malodorant and noise from animal housings have bad effects on the rural living conditions. So developments of integrated complex for small scale livestock farms are required.

  • PDF

Evaluation of Reduction of CO2 Emission Achieved by Using Low-carbon Recycled Cement with Cementitious Waste Powder (폐미분말을 원료로 한 저탄소형 재생시멘트의 CO2배출량 저감평가)

  • Kwon, Eun-Hee;Ahn, Jae-Cheol;Park, Dong-Cheon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.250-251
    • /
    • 2014
  • With the recent movement toward sustainable development, many efforts have been made to reduce environmental loads in various domains of industry. In particular, a great deal of research and technology development has been underway on approaches to reducing industrial waste and the emission of greenhouse gases. For this reason, a quantitative analysis of the reduction in CO2 emission that could be achieved by replacing limestone material with cementitious waste powder was performed in this study. Through the analysis, it was found that CO2 emissions were reduced by up to 50 percent compared with the scenario in which OPC was used, which suggests that it is possible to reduce global CO2 emissions by approximately 5percent, or by 446.4 Tg of the 965 Tg of CO2 emissions generated by the cement industry, in the total global CO2 emissions of 19300Tg.

  • PDF

Ultimate Load and Load Distribution of Ground Anchor in Waste Landfill (쓰레기 매립층에서 그라운드 앵커의 극한하중 및 하중분포)

  • Kim, Sung-Kyu;Cho, Kyu-Wan;Kim, Woong-Kyu
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1434-1441
    • /
    • 2005
  • For anchored system applications, each ground anchor is tested after installation and prior to being put into service to loads that exceed the design. This load testing methodology, combined with specific acceptance criteria, is used to verify that the ground anchor can carry the design load without excessive deformations and that the assumed load transfer mechanisms have been properly developed behind the assumed critical failure surface. After acceptance, the ground anchor is stressed to a specified load and the load is locked-off. The two types of load tests conducted during the research program included performance test and creep test which were carried out in accordance with testing procedures by AASHTO(AASHTO 1990) and FHWA(Weatherby 1998) at Samsung-Dong 00 Site. Form the measurements, ultimate load and creep rate of anchors are proposed for straight shaft pressured grouted anchors in waste landfill. The load distribution on the grout was obtained from the measured strain data at each fraction of the ultimate load during the load tests.

  • PDF

Investigation of Leachate Leakage in Waste Landfill by Tracer Test (추적자시험에 의한 폐기물매립장 침출수 누출조사)

  • 이광열;이영준;장삼식
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.4
    • /
    • pp.49-56
    • /
    • 2004
  • Tracer tests were conducted to investigate leachate outflow through damaged parts on HDPE liner subject to puncture loads in a closed landfill. Natural gradient tracer test was used with two different types of tracers, iodide and Rhodamine WT. Tracers were selected under careful consideration of chemical components of leachate. Five injection wells with fourteen detection points were installed and operated throughout the test site. In this study, it is found that Iodide and Rhodamine WT are applicable and effective for leachate leakage investigation on waste landfills. Also, it is concluded that considerable amount of leachate was leaked through the rain water drain box and side wall of drain box.

INTEGRATED WATER RESOURCES AND QUALITY MANAGEMENT SYSTEM USING GIS/RS TECHNOLOGIES

  • Shim, Kyu-Cheoul;Shim, Soon-Bo;Lee, Yo-Sang
    • Water Engineering Research
    • /
    • v.3 no.2
    • /
    • pp.85-92
    • /
    • 2002
  • There has been continuous efforts to manage water resources for the required water quality criterion at river channel in Korea. However, we could obtain the partial improvement only for the point sources such as, waste waters from urban and factory site through the water quality management. Therefore, it is strongly needed that the best management practice throughout the river basin fur water quality management including non-point sources pollutant loads. This problem should be resolved by recognizing the non-point sources pollutant loads from the upstream river basin to the outlet of the basin depends on the landuse and soil type characteristics of the river basin using the computer simulation by a distributed model based on the detailed investigation and application of Geographic Information System (GIS). The purpose of this study is consisted of the three major distributions, which are the investigation of spread non-point sources pollutants throughout the river basin, development of the base maps to represent and interpret the input and outputs of the distributed simulation model, and prediction of non-point sources pollutant loads at the outlet of a up-stream river basin using Agricultural Non-Point Sources Model (AGNPS). For the validation purpose, the Seom-Jin River basin was selected with two flood events in 1998. The results of this application showed that the use of combined a distributed model and an application of GIS was very effective fur the best water resources and quality management practice throughout the river basin

  • PDF

The effect of bleaching reagents on bleachabilities of DIP and environmental loads (탈묵펄프용 표백약품에 따른 표백 특성 및 표백폐수의 환경부하 영향)

  • Ahn, Chi-Deuk;Park, Jung-Yoon;Hwang, Sung-Jun;Hong, Seok-Jun;Lee, Jin-Hee;Kim, Hyoung-Jin;Chung, Sung-Hyun
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.47 no.1
    • /
    • pp.66-74
    • /
    • 2015
  • DIP(deinked pulp) was bleached by FAS, $Na_2S_2O_4$ and $H_2O_2$, which are widely used in DIP bleaching process, in order to improve optical properties of DIP, and the bleaching efficiencies of DIP and environmental loads of waste water were compared, depending on bleaching chemical dosages. With the application of different bleaching chemicals, some positive improvements were shown in optical and physical properties of bleached pulp. However, the physical properties of bleached DIP and their characteristics of wastewater were remarkably different, depending on dosages and bleaching reagents. DIP chemicals with FAS and $Na_2S_2O_4$ have higher improvement in optical and physical properties than $H_2O_2$. Also, environmental loads such as pH, turbidity, SCODcr and cationic demand were decreased in reductive bleaching process. Despite of higher effectiveness of reductive bleaching process, there were some environmental problems caused by sulfur ions from FAS and $Na_2S_2O_4$. With the method of sulfur ion controls, it would be more effective than $H_2O_2$ bleaching process.

Evaluation of Canister Weld Flaw Depth for Concrete Storage Cask (콘크리트 저장용기의 캐니스터 용접부 결함깊이 평가)

  • Moon, Tae-Chul;Cho, Chun-Hyung;Jung, Sung-Hun;Lee, Young-Oh;Jung, In-su
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.15 no.1
    • /
    • pp.91-99
    • /
    • 2017
  • Domestically developed concrete storage casks include an internal canister to maintain the confinement integrity of radio-active materials. In this study, we analyzed the depth of flaws caused by loads that propagate canister weld cracks under normal, off-normal and accident conditions, and evaluated the maximum allowable weld flaw depth needed to secure the structural integrity of the canister weld and to reduce the welding time of the internal canister lid of the concrete storage cask. Structural analyses for normal, off-normal and accident conditions were performed using the general-purpose finite element analysis program ABAQUS; the allowable flaw depth was assessed according to ASME B&PV Code Section XI. Evaluation results revealed an allowable canister weld flaw depth of 18.75 mm for the concrete storage cask, which satisfies the critical flaw depth recommended in NUREG-1536.

Long-term Loads based on Evaluation of Resistance and Seakeeping Performances for a Desalination Plant Ship (해상 이동형 해수담수화 플랜트 선박의 저항 및 내항 성능 평가에 따른 장기 하중 추정)

  • Lee, Jae-bin;Paik, Kwang-Jun;Choung, Joonmo
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.6
    • /
    • pp.632-640
    • /
    • 2019
  • Desalination plant ships have been recently regarded as one of the probable solutions for drought seasons in many countries. Because desalination plants should be mounted on the desalination ships and special purpose storages such as salty waste water tanks are necessary, onboard and compartment arrangements would be distinguished from those of other conventional commercial ships. This paper introduces some basic design procedure including resistance/propulsion and seakeeping performances. The ship lines were improved step by step after modification of the ship lines and verification of resistance/propulsion performances using computational fluid dynamics (CFD). After finalization of the ship lines, the seakeeping performance was also evaluated to check motion behaviors and drive wave-induced loads such as the wave shear force and bending moment. It was proved that the predicted long-term vertical wave shear force and bending moment were significantly less than the rule-based ones, thus it is expected that the deliverables of this study will reduce the construction cost of desalination plant ships.

Non-Duplication Loading Method for supporting Spatio-Temporal Analysis in Spatial Data Warehouse (공간 데이터웨어하우스에서 시공간 분석 지원을 위한 비중복 적재기법)

  • Jeon, Chi-Soo;Lee, Dong-Wook;You, Byeong-Seob;Lee, Soon-Jo;Bae, Hae-Young
    • Journal of Korea Spatial Information System Society
    • /
    • v.9 no.2
    • /
    • pp.81-91
    • /
    • 2007
  • In this paper, we have proposed the non-duplication loading method for supporting spatio-temporal analysis in spatial data warehouse. SDW(Spatial Data Warehouse) extracts spatial data from SDBMS that support various service of different machine. In proposed methods, it extracts updated parts of SDBMS that is participated to source in SDW. And it removes the duplicated data by spatial operation, then loads it by integrated forms. By this manner, it can support fast analysis operation for spatial data and reduce a waste of storage space. Proposed method loads spatial data by efficient form at application of analysis and prospect by time like spatial mining.

  • PDF