국내 건설 폐기물 활용 현황 및 활성화에 관한 연구 (A Study on the Method Applying Construction Wastes of Construction in Korea)

  • 장재명;최희복;강경인
    • 한국건축시공학회지
    • /
    • 제3권1호
    • /
    • pp.147-154
    • /
    • 2003
  • Recently, the amount of the construction and demolition wastes has rapidly increased due to increasing construction projects. In the past, most of the construction and demolition wastes were buried in the ground of thrown away. Illegally, without any treatment, so various harmful environmental pollution problems were occurred. In this study, the domestic data on the amount of the construction and demolition wastes and the disposal methods were collection and analysed. Specially, the recycling and management systems of the construction and asphalt concrete wastes were studied. A new technology and necessary policy for recycling were suggested. In general, the industrial wastes were produced in the particular place, and the amount and the characteristics of the wastes able to be estimated by the studies on the treatment technology. And the investment of the facilities for the industrial wastes have been made continuously. But little attention has been relatively given to the treatment technology. And system for the construction and demolition wastes for the political support and facilitation on the proper treatment and the recycling, the necessary of information exchange system and the manifest system for treatment of waste on commission were recommended, and also devised methods to develope and support the recycling industry. In the future, the subject of study is going to carry out analysis of economic and market in making products.

대청호 정체수역의 수질예측과 관리 (Management of Water Quality of Embayments in Daechong Reservoir)

  • 이종호
    • 환경영향평가
    • /
    • 제3권2호
    • /
    • pp.33-45
    • /
    • 1994
  • Water quality of Chongju and Daejeon Water Intake Tower Region, embayments in Daechong Reservoir was found to be worse than that of main lake after analysis of water which were sampled during April, July, October in 1993. Concentration of COD and SS at those two water intake tower sites were 2.8-5.6 mg/l and 2.2-3.2 mg/l, higher than that of main lake. T-N concentration of those two sites was 1.1-1.9 mg/l similar to that of main lake, and T-P concentration of those two sites was 0.14-0.18 mg/l, higher than that of main lake. This study used water quality model of embayment which can analyse pollutant loads from stream and surrounding land use, advection, decay, and diffusion transport between embayment and main lake. The model can predict water quality of embayment according to the change of pollutant load, water elevation of embayment, quantity of water intake in order to suggest water quality management. This study suggests embayment water quality management alternatives, 1) construction of waste water treatment facilities at embayment and main lake for the decrease of pollutant loading, 2) water intake at main lake less polluted or eutrophicated than embayment, and 3) outflow elevation selection for polluted hypolimnion water outflow during stratification.

  • PDF

식당 주방의 위생 향상을 위한 공간계획에 관한 연구 (A Study on the Space Planing for Restaurant Kitchens to Improve Hygiene)

  • 이종란
    • 한국디지털건축인테리어학회논문집
    • /
    • 제11권1호
    • /
    • pp.5-13
    • /
    • 2011
  • This research proposed the space planing methode and diagrams of restaurant kitchens to improve hygiene by analyzing the related contents collected from books and researches in interior design and HACCP (Hazard Analysis and Critical Control Point). HACCP is an effective and scientific hygiene system for food safety in order to prevent cross-contamination from food hazards. Based on the analyses, improvement of food production environments like restaurant kitchens is necessary for food hygiene. The space planing methode of restaurant kitchens to improve hygiene are followings: The circulation planing is that the direction of movement of the food, workers, waste, and dishes should be fractionated and managed for cross-contamination prevention. The space separation planing is that the spaces in the kitchen should be classified and divided into contaminated area and non-contaminated and clean area depending on the degree of cleanliness. The zoning is space arrangement with feed-back process to check the possible points of cross-contamination and correct space arrangement until the possibility of cross-contamination disappear in kitchen. However, if cross-contamination is unavoidable in some points in restaurant kitchens, hygiene facilities such as washing rooms, pass rooms, and double doors with air-shower should be located in order to remove contamination.

Water treatment sludge for removal of heavy metals from electroplating wastewater

  • Ghorpade, Anujkumar;Ahammed, M. Mansoor
    • Environmental Engineering Research
    • /
    • 제23권1호
    • /
    • pp.92-98
    • /
    • 2018
  • Suitability of aluminium-based water treatment sludge (WTS), a waste product from water treatment facilities, was assessed for removal of heavy metals from an electroplating wastewater which had high concentrations of copper and chromium along with other heavy metals. Batch tests with simulated wastewater in single- and multi-metal solutions indicated the influence of initial pH and WTS dose on removal of six metals namely Cu(II), Co(II), Cr(VI), Hg(II), Pb(II) and Zn(II). In general, removal of cationic metals such as Pb(II), Cu(II) and Zn(II) increased with increase in pH while that of anionic Cr(VI) showed a reduction with increased pH values. Tests with multi-metal solution showed that the influence of competition was more pronounced at lower WTS dosages. Column test with diluted (100 times) real electroplating wastewater showed complete removal of copper up to 100 bed volumes while chromium removal ranged between 78-92%. Other metals which were present in lower concentrations were also effectively removed. Mass balance for copper and chromium showed that the WTS media had Cu(II) and Cr(VI) sorption capacities of about 1.7 and 3.5 mg/g of dried sludge, respectively. The study thus indicates that WTS has the potential to be used as a filtration/adsorption medium for removal of metals from metal-bearing wastewaters.

해체 데이터베이스 개념적 모델링 및 정보 분류 체계 확립 (Establishment of the Classification scheme and Conceptual Modeling on the Decommissioning Database)

  • 박희성;박승국;정기정;장세규
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 2002년도 춘계 학술발표회 논문집
    • /
    • pp.43-48
    • /
    • 2002
  • 연구로 1호기와 2호기의 해체 DB 구축을 위한 정보전략계획(ISP: Information Strategy Planning)연구가 수행되었다. 해체 DB 구축 범위를 설정하기 위해 사용자 요구사항과 정보 자료 중요도를 분석하였고, 해체 DB 개념을 정립하였으며, 해체와 관련한 정보 및 자료들의 분류 체계를 확립하였다. 해체와 관련한 20여종의 자료 수집과 연구로 1, 2호기 시설방문을 통한 시설조사 및 현황, 그리고 연구로 해체 설계자와 방사성폐기물 관리 전문가, 방사선안전관리 전문가와의 면담을 통하여 해체 시설정보, 작업자 정보, 폐기물 정보, 그리고 방사선학적 정보를 도출하였다. 또한 해체 정보들을 코드화하였다. 연구를 통하여 얻어진 해체 데이터 모델링 결과와 해체 정보들에 대한 분류 체계 결과는 해체 DB Prototype 설계를 위한 기초자료로 활용될 것이다.

  • PDF

가축매몰지 소멸시 잔존물 처리방안 (Treatment of residues of excavated carcasses burials)

  • 김건하
    • 상하수도학회지
    • /
    • 제32권3호
    • /
    • pp.269-277
    • /
    • 2018
  • Burials for the rapid disposal of carcasses have diverse and profound effects on the rural living condition, natural environment, and local economy throughout construction, management and final destruction of burials. In this study, possible residue excavated from standard burials, storage using FRP (Fiberglass Reinforced Plastic) tanks, and microbial-treated burials are characterized as carcasses, contaminated soil by leachate, and wasted plastic film. Treatment technologies for volume reduction of the residue including composting, rendering, and thermal hydrolysis were investigated. If the solid and liquid residues generated during volume reduction treatment are directly transferred to the environmental facilities, it may cause disorder due to high concentrations of organics, antibiotics, and lipid. Benefits and drawbacks of composting as a volume reduction techniques are extensively investigated. We also discussed that proper treatment of excavated soils and the reusing the treated soil as agricultural purpose. For the protection of public health and worker's hygiene, treatment criteria including produced residue qualities, and quality standards for the treated soil as agricultural use are required. In addition, Scientific manual for the proper treatment of residues is required. It is necessary to consider the establishment of a pretreatment facility to the occurrence of large-scale residue treatment.

충주시 악취발생원으로부터 배출되는 악취원인물질 특성 분석 (Characterization of Odorous Elements from Emission Sources in Chungju)

  • 조병렬;조영민
    • 대한환경공학회지
    • /
    • 제30권4호
    • /
    • pp.415-422
    • /
    • 2008
  • 충주시에 소재하는 주요 환경시설로부터 배출되는 악취성 물질의 배출특성을 주민 민원에 대한 설문과 정치형 시료채취기를 활용하여 조사하였다. 네 군데의 조사시설 가운데 분뇨처리장이 가장 높은 악취농도를 보여주었다. 악취성물질의 주요 성분은 황화합물, 트리메칠아민, 알데히드 등이었다. 음식물 쓰레기 처리공정은 황화합물과 알데히드를 많이 배출하였다. 도시하수처리장은 고농도의 알데히드를 배출하는 것으로 나타났다. 악취의 관능 수준은 기상여건에 따라 다양하였으며, 심야의 악취 강도가 주간보다 훨씬 심각하게 나타났다.

터널 굴착시 발생하는 지하수의 유출량 예측에 관한 연구 (A Study on the Prediction of Outflow of Groundwater in Tunnel Construction Areas)

  • 박선환;장윤영;강형식;최준규;양근호
    • 환경영향평가
    • /
    • 제16권6호
    • /
    • pp.407-419
    • /
    • 2007
  • This study investigated the predicted and abserved outflow of groundwater which occurred during tunnel constructions. Among the 586 road construction projects from 1986 to 2006, 4 route 25 tunnel construction areas and 26 waste water treatment facilities under construction were studied. Most of the tunnel outflow prediction in EIA (Environmental Impact Assessment) process have been classified into the 17 types of units depending on the assessor's options, which have not conformed to the request of the residents and non government organizations. The investigation results showed that the outflow of underground water in tunnel construction areas averaged about $0.133m^3/km{\cdot}min$ with the maximum $0.386m^3/km{\cdot}min$, and that the outflow mostly occurred in the early stage of tunnel excavation and diminished gradually. The prediction of outflow of underground water in the EIA process showed excessive results compared to observed outflow, the even 51.7 times. Consequently for more realistic prediction, current EIA method for prediction of outflow of underground water in tunnel construction areas has to adopt numerical methods coupled with hydraulics and geologic informations from unit methods of present time.

친환경 캠퍼스 평가 기준 도출에 관한 연구 (A Study on the Assesment Guideline for Environment-Friendly University Campuses)

  • 노미영;신지훈;임승빈
    • 한국환경복원기술학회지
    • /
    • 제11권4호
    • /
    • pp.103-118
    • /
    • 2008
  • University campuses, in Korea, experienced expansion during the 1970's and exceeded its capacity in the 1980's. On the other hand, universities needed to deal with increasing capacity and expansion of its facilities. This study is carried out in three steps : developing the factors of environmental friendly assessment, designing an assessment table based on specific categories, and applying the categories to the campus of Seoul National University. The assessment factors and assessment table were designed through a survey of experts in landscaping, architecture, and urban planning. The elements of major categories were classified as follows; 1) Management of land and accessibility, 2) Pollution and waste matter, 3) Energy, 4) Natural resources, 5) Operation, maintenance and management of environmental friendly campus. And, this study classified five major categories into twenty subcategories on the evaluation of the environmental friendly campus. The twenty subcategories include various fields such as architecture, landscape architecture, environment, urban design, and social sciences etc., profound studies at this line should make more precise assesment guidelines.

Sorption of chlorophenols on geotextile of the geosynthetic clay liners

  • Ahari, M'hamed;Touze-Foltz, Nathalie;Mazeas, Laurent
    • Environmental Engineering Research
    • /
    • 제25권2호
    • /
    • pp.163-170
    • /
    • 2020
  • Knowledge of organic micropollutant transfers in barrier seal materials from waste storage facilities is limited to volatile organic compounds and phenolic compounds at ambient temperature. This study focused on the sorption of chlorophenols (CPs) from various geotextiles from clay geosynthetics under the influence of temperature. Also to study the impact of the polarity or the amount of CPs adsorbed on geotextiles with the partition coefficient. The effect of various parameters such as contact time, effect of temperature, initial CPs concentration and adsorbent dosage has been carried out in this study. The result obtained is non-linear and the data was calculated for affinity with Freundlich isotherm model. An important observation is that the amount of CPs sorbed on geotextiles increases with a growing number of chlorine atoms, ie increases with the partition coefficient (log Kow). During this study, a decrease in adsorbent properties was observed with the rise in temperature from 23℃ to 55℃. The partitioning coefficients for CPs examined range are from 2.4 (R2 = 0.86) to 8.4 mL/g (R2 = 0.90). Among the CPs studied, the highest adsorbed quantity was observed for pentachlorophenol with 0.052 g/g at 23℃, this quantity will decrease with the increase in temperature.