• 제목/요약/키워드: Warm Water Method

검색결과 89건 처리시간 0.025초

토장국의 문헌적 분석 고찰 (A bibliographical Study on the Tojangguk in Korea)

  • 이윤경;전희정;이효지
    • 한국식생활문화학회지
    • /
    • 제7권1호
    • /
    • pp.81-90
    • /
    • 1992
  • The Guk had lessened to use Gang, Whak, Tang. The Guk was classified into cooking method as a soup stock, the used main substances, and the temperature of the Guk. According to the soup stock were divided clear soup, Tojangguk, and Gooumguk. Another classification of Guk by main substances were Yuktang (meat soup), Otang (fish soup), bongtang (poultry soup), Shotang (vegetable soup), Japtang (vary substance soup) and Yonpotang (soybean-curd soup), and by the temperature of the Guk were divided Doounguk (warm soup) and Naengguk (cold soup). In the thesis, according to the kinds of Tojangguk, the reference frequency to them, the adding foods in them, and the variety cooking method in the Tojangguk were analyzed by the cook books published from 1700 to 1988 in Korea. 1. There were 29 kinds of Tojangguk. 2. The main substances of Tojangguk were meat, poultry, fish, shellfish, vegetable, mushrooms and seasonings. 3. The Tojangguk was boiled with the rice water and fermented soybean paste and fermented soybean-pepper powder paste. For the development of taste were added beef, shellfish, dried anchovy, dried small prawn, and soup stock of beef bones in winter. Seasoning substances were green onion, garlic, black pepper, sesame powder and oil.

  • PDF

화물선의 결로 방지에 대한 연구 (A Study on the Condensation Prevention of Bulk Carrier)

  • 오세진;김원욱;김성환;이성근;김종수
    • 해양환경안전학회지
    • /
    • 제17권4호
    • /
    • pp.429-434
    • /
    • 2011
  • 선박에 적재된 곡류, 철강재 등의 산적화물에 여러 가지 이유로 손상이 발생될 수 있다. 본 논문에서는 코일 운반선의 화물손상 원인 중 특히, 결로에 의한 손상과 그에 대한 방지대책에 대해 분석하고자 한다. 결로란 주위 온도가 이슬점 이하로 떨어져 물체 표면에 공기 중의 수증기가 물방울로 맺히는 현상을 말하며 일반적으로 실내외 온도차가 큰 건축물이나 선박의 화물창에서 많이 발생한다. 특히, 비슷한 시기에 기온차가 있는 전 세계를 운항하는 선박에서 흔히 발생할 수 있는 현상이다. 본 연구에서는 코일 운반선의 결로에 의한 화물손상 방지 대책에 대해 고찰하고 화물손상을 방지하기 위해 제습장치와 가열온풍장치를 병용하는 새로운 방법의 제안과 습도, 습기량, 제습장치 용량, 결로수량, 화물 및 공기와 외기의 온도 차이에 따른 화물창 내 공기와 화물 가열에 필요한 열량, 가열장치 용량 등의 산정법을 제시한다.

자료동화 기법에 따른 황·동중국해 지역 해양순환모델 결과 비교 (Comparison of Data Assimilation Methods in a Regional Ocean Circulation Model for the Yellow and East China Seas)

  • 이준호;문재홍;최영진
    • Ocean and Polar Research
    • /
    • 제42권3호
    • /
    • pp.179-194
    • /
    • 2020
  • The present study aims to evaluate the effects of satellite-based SST (OSTIA) assimilation on a regional ocean circulation model for the Yellow and East China Seas (YECS), using three different assimilation methods: the Ensemble Optimal Interpolation (EnOI), Ensemble Kalman Filter (EnKF), and 4-Dimensional Variational (4DVAR) techniques, which are widely used in the ocean modeling communities. The model experiments show that an improved initial condition by assimilating the SST affects the seasonal water temperature and water mass distributions of the YECS. In particular, the SST data assimilation influences the temperature structures horizontally and vertically in winter, thereby improving the behavior of the YS warm current water. This is due to the fact that during wintertime the water column is well mixed, which is directly updated by the SST assimilation. The model comparisons indicate that the SST assimilation can improve the model performance in resolving the subsurface structures in wintertime, but has a relatively small impact in summertime due to the strong stratification. The differences among the different assimilation experiments are obvious when the SST was sharply changed due to a typhoon passage. Overall, the EnKF and 4DVAR show better agreement with the observations than the EnOI. The relatively low performance of EnOI under storm conditions may be related with a limitation of EnOI method whereby an analysis is obtained from a number of climatological fields, and thus the typhoon-induced SST changes in short-time scales may not be adequately reflected in the data assimilation.

제주지역 지하공기를 이용한 농업시설용 히트펌프시스템의 난방 성능 분석 - 제주지역을 중심으로 - (The Analysis of heating performance of heat pump system for agricultural facility using underground air in Jeju area - Focused on the Jeju Area -)

  • 강연구;임태섭
    • KIEAE Journal
    • /
    • 제16권6호
    • /
    • pp.109-114
    • /
    • 2016
  • Purpose: The underground air is the warm air discharged from the porous volcano bedrock 30-50m underground in Jeju, including excessive humidity. The temperature of the underground air is $15-20^{\circ}C$ throughout the year. In Jeju, the underground air was used for heating greenhouses by supplying into greenhouses directly. This heating method by supplying the underground air into greenhouses directly had several problems. The study was conducted to develop the heat pump system using underground air as heat source for resolving excessive humidity problem of the underground air, adopting the underground air as a farm supporting project by Ministry of Agriculture, Food and Rural Affairs(MAFRA) and saving heating cost for agricultural facilities. Method: 35kW scale(10 RT) heat pump system using underground air installed in a greenhouse of area $330m^2$ in Jeju-Special Self-Governing Province Agricultural Research & Extension Services, Seogwipo-si, Jeju. The inlet and outlet water temperature of the condenser, the evaporator and the thermal storage tank and the underground air temperature and the air temperature in the greenhouse were measured by T type thermocouples. The data were collected and saved in a data logger(MV200, Yokogawa, Japan). Flow rates of water flowing in the condenser, the evaporator and the thermal storage tank were measured by an ultrasonic flow meter(PT868, Panametrics, Norway). The total electric power that consumed by the system was measured by a wattmeter(CW240, Yokogawa, Japan). Heating COP, rejection heat of condenser, extraction heat of evaporator and heating cost were analyzed. Result: The underground air in Jeju was adopted as a farm supporting project by Ministry of Agriculture, Food and Rural Affairs(MAFRA) in 2010. From 2011, the heat pump systems using underground air as a heat source were installed in 12 farms(16.3ha) in Jeju.

Analysis of Visual Sensibility Evaluation of Naturally Colored Organic Cotton: Identification of Reliability and Proper Scouring Method

  • Park, Jang-Woon;Chang, Yoon;Hong, Won-Gi;Lee, Myung-Eun;Han, Ah-Reum;Chae, Young-Joo;Cho, Gil-Soo;You, Hee-Cheon
    • 대한인간공학회지
    • /
    • 제30권2호
    • /
    • pp.311-317
    • /
    • 2011
  • Objective: The present study was intended to identify (1) the intra- and inter-rater reliabilities of a visual sensibility evaluation protocol and (2) the effects of NaCOC color and scouring method on the visual sensibility of NaCOC. Thirty female participants(20s & 30s) were participated in the visual sensibility evaluation of NaCOC. Background: Interests in naturally colored organic cotton(NaCOC) increase rapidly in parallel with the social trend of eco-friendly living and wellbeing. Method: Three color sets (ivory, green, and coyote-brown) of NaCOC specimens including one untreated and four treated specimens($Na_2CO_3$; NaOH; enzyme; boiling water) were examined in the study. The visual sensibility evaluation was conducted by the test-retest method using nine pairs of bipolar visual sensibility adjectives(bright-dark; clear-murky; heavy-light; vivid-subdued; warm-cool; fresh-stale; strong-weak; showy-plain; and luxurious-cheap). Results: As a result of reliability of a visual sensibility evaluation protocol, inter-rater variability(average SD=1.06) of visual sensibility evaluation was more than 1.4 times the intra-rater variability(average SD=0.74). However, both the sensibility evaluation reliabilities did not show any systematic pattern of changes. Lastly, ANOVA and post-hoc analysis showed that preferred scouring methods for a visual sensibility adjective pair significantly vary depending on NaCOC color. Application: Both the reliability of visual sensibility evaluation protocol and the analysis of proper scoring method of NaCOC in the study would be useful information to design the affective textile.

발전 및 해수담수화를 위한 태양열-해양온도차 복합 시스템에 대한 연구 (A Study on the Solar-OTEC Convergence System for Power Generation and Seawater Desalination)

  • 박성식;김우중;김용환;전용한;현창해;김남진
    • 한국태양에너지학회 논문집
    • /
    • 제34권2호
    • /
    • pp.73-81
    • /
    • 2014
  • Ocean thermal energy conversion(OTEC) is a power generation method that utilizes temperature difference between the warm surface seawater and cold deep sea water of ocean. As potential sources of clean-energy supply, Ocean thermal energy conversion(OTEC) power plants' viability has been investigated. Therefore, this paper evaluated the thermodynamic performance of solar-OTEC convergence system for the production with electric power and desalinated water. The comparison analysis of solar-OTEC convergence system performance was carried out as the fluid temperature, saturated temperature difference and pressure of flash evaporator under equivalent conditions. As a results, maximum system efficiency, electric power and fresh water output show at 40, 10, 2.5 kPa of the flash evaporator pressure, respectively. And their respective enhancement ratios were approximately 6.1, 18, 8.6 times higher than that of the base open OTEC system. Also, performance of solar-OTEC system is the highest in the flash evaporator pressure of 10 kPa.

대마난류의 유동 특성과 PDO의 관계 분석 (Analysis of the Relationship between the Flow Characteristics of the Tsushima Warm Current and Pacific Decadal Oscillation)

  • 서호산;정용현;김동선
    • 해양환경안전학회지
    • /
    • 제28권6호
    • /
    • pp.882-889
    • /
    • 2022
  • 본 연구에서는 대마난류(Tsushima Warm Current, TWC)의 유동 변화에 영향을 주는 요소를 파악하기 위하여 TWC의 수송량과 태평양 순년진동(Pacific Decadal Oscillation, PDO) 및 엘니뇨 남방진동(El Niño - Southern Oscillation, ENSO)의 상호 관계 분석을 실시하였다. 25년(1993~2018년) 동안의 TWC의 월별 수송량을 계산해보면 하계에 가장 크고 동계에 가장 작게 나타나는 계절변동 주기가 뚜렷하다. TWC 수송량과 PDO 및 ENSO의 한 척도인 Oceanic Niño Index(ONI) 각각의 주기성 파악을 위한 power spectrum 분석결과, TWC 수송량은 1년 주기에서 peak를 보이지만 PDO 및 ONI는 뚜렷한 주기가 나타나지 않았다. 또한, TWC 수송량과 PDO 및 ONI의 상호 관계 파악을 위해 coherence 추정 방법을 이용하여 분석하였다. PDO 및 ONI의 coherence는 3년 이상의 장주기 변동에서 상호 기여도가 높으나 1년 이내의 단주기 변동에서는 상호 기여도가 낮다. 그러나 TWC 수송량과 PDO 두 요소 간 0.8~1.2년 주기에서 coherence 값은 0.7로 상호 기여도가 높다. 한편 서수도를 통과하는 TWC 수송량과 PDO는 I기간(1993~2002년)과 III기간(2010~2018년)에 역상관 관계성을 가진다. TWC 최대 수송량 (2.2 Sv 이상)이 높게 나타나는 시기에 PDO 지수가 -1.0 이하의 음의 값, 2.2 Sv 이하로 작은 시기에 PDO 지수가 양의 값을 나타낸다. 따라서 장기적인 PDO 지수 자료를 이용하면 TWC 수송량 변동 및 동해 연안역의 수온변화를 예측 또한 가능할 것으로 판단된다.

한국 남해연안의 해표면 수온분포와 천해전선의 변동 특성 (Variations of the Sea Surface Temperature Distribution and the Shelf Fronts in the Cheju Strait and the Korea Strait)

  • 양성기
    • 한국환경과학회지
    • /
    • 제3권2호
    • /
    • pp.111-128
    • /
    • 1994
  • 서귀포와 부산사이를 취항하고 있는 “카페리 제 주1호”에 수온계를 설치하여 1990년 10월 부터 10 개월간 제주해협과 대한해협을 횡단하는 해역에서 표면수온의 관측을 실시하였다. 그 결과 거문도 부근의 해역에서 뚜렷한 수온전선이 형성되고 있 으나, 그 위치는 약간의 변동성을 냐타내고 있었 다. 전선이 북으로 이동할 때는 비교적 느리고 뚜 렷하나 남으로 이동할 때는 전선구조가 분명하지 않았다. 수온전선에는 수십일 주기를 가진 단주기 변동이 관측된다. 이 변동은 동계 강한 북서계절 풍의 영향과 열이동의 효과로 인한 것으로 사료된 다 표변수온의 수평구배가 3월부터 10월에 걸쳐 매우 약하고, 그 이외의 시기에는 확실하다. 이러 한 결과는 제주해협과 대한해협을 횡단하는 표면 수온의 연속적 인 관측이 한국남안수의 소장과 대 마난류수의 출현 동을 모니터하는데 매우 유효함 을 나타내고 있다. 제주해협과 대한해협에서의 해양관측을 통하여 추자도 부근 해역에서 형성되는 연안전선의 구조 를 파악하였다. 이 전선은 연중 형성되고 있으나, 계절과 연에 따라 그 위치 및 분포형상이 매우 다 르다 이같은 연안전선이 대한해협에서는 매우 약 하게 형성되고 있었다.

  • PDF

Effect of Flue Gas Heat Recovery on Plume Formation and Dispersion

  • Wu, Shi Chang;Jo, Young Min;Park, Young Koo
    • 한국입자에어로졸학회지
    • /
    • 제8권4호
    • /
    • pp.161-172
    • /
    • 2012
  • Three-dimensional numerical simulation using a computational fluid dynamics (CFD) was carried out in order to investigate the formation and dispersion of the plume discharged from the stack of a thermal power station. The simulation was based on the standard ${\kappa}{\sim}{\varepsilon}$ turbulence model and a finite-volume method. Warm and moist exhaust from a power plant stack forms a visible plume as entering the cold ambient air. In the simulation, moisture content, emission velocity and temperature of the flue gas, air temperature and wind speed were dealt with the main parameters to analyze the properties of the plume composed mainly of water vapor. As a result of the simulation, the plume could be more apparent in cold winter due to a big difference of latent heat capacity. At no wind condition, the white plume rises 120 m upward from the top of the stack, and expands to 40 m around from the stack in cold winter after flue gas heat recovery. The influencing distance of relative humidity will be about 100 m to 400 m downstream from the stack with a cross wind effect. The decrease of flue gas temperature by heat recovery of thermal energy facilitates the formation of the plume and restrains its dispersion. Wind speed with vertical distribution affects the plume dispersion as well as the density.

PLC를 이용한 온실의 환경제어 (Control of Environments in Greenhouse Using Programmable Logic Controller)

  • 김동억;조한근;김형준
    • Journal of Biosystems Engineering
    • /
    • 제23권6호
    • /
    • pp.599-606
    • /
    • 1998
  • This study was carried out to develop the control system with PLC and its operating software and to investigate its control ability of greenhouse environments. Two experimental greenhouses were controlled by PLC and ON/OFF controller, respectively. In greenhouse controlled by PLC, target values of air temperature, relative humidity and $CO_2$ concentration were automatically changed. In warm-water heating, the variation of air temperature was reduced to $\pm$ $0.6^{\circ}C$ by the method of proportional-integration(PI) control with an inverter. In ventilation, the variation of air temperature was reduced, since windows open and close with multistage by mutual relation formula among the target, indoor, and outdoor temperature. Relative humidity at daytime was maintained with range of 35% to 55% by PLC controlled fogger. $CO_2$ concentration was automatically controlled from 300 to 800 $\mu$molㆍ$mol^{-1}$ according to amount of solar radiation. The suppling amount and frequency of nutrient solution were controlled by total integrated solar radiation. Difference in the yield of cucumber in the greenhouse controlled by PLC and by ON/OFF controller was not significant at the 5% level.

  • PDF