• 제목/요약/키워드: Wall panel

검색결과 439건 처리시간 0.029초

Car Parking Lot 모니터링 시스템 (Monitoring System with PLC I/O for Car Parking Lot)

  • 이성재;김재양
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.511-512
    • /
    • 2007
  • The monitoring system has won acceptance as a premium mark that identifies the highest standard of product quality in advanced industry. The TOP features with multi-I/O ports and VGA & RCA TV-out ports supporting mirroring & multiple dual-display modes by windows 0/5. With the choice of versatile stands, panel mount, or VESA wall-mount swing arm and connecting to modem. Wireless keyboard, Customer Display and Card Reader, is your idea Panel system for the application of TOP(Touch Operation Pannel), KIOSK, or Office / Factory Automation. TOP is the hardware and software product that transacts all kind of functions for advanced technology equipment to button, switch, voice and graph etc so that let consumer use easily Industrial HMI System Touch Panel. System characteristics: Easy of use and flexibility to the user, Present a high value solution and advanced function for many Application, Factory Automation, Office Automation, Building Automation System, Information Service System, etc. Analog Touch - 2MB Flash Memory for Saving Screen Data - RS-232C/422 Serial Port - Multi Language Support.

  • PDF

대형 콘크리트 패널구조 수평접합부의 지지력 성능에 관한 연구 (Compressive Strength of Horizontal Joints in Precast Concrete Large Panel System)

  • 서수연;정봉오;이원호;이리형
    • 콘크리트학회지
    • /
    • 제6권2호
    • /
    • pp.138-147
    • /
    • 1994
  • 대형 콘크리트 판넬구조 수평접합부는 상부로부터 전달되는 축하중에 대하여 저항하게 되며 이때의 저항내력은 그라우트와 판넬의 강도, 접합부의 형태 및 단부 모멘트, 그라우트의 폭 등에 따라 변하게 된다. 본 연구는 패쇄형 수평접합부에 대한 실험연구로서 슬래브의 단부형태, 벽판넬의 단부보강 및 슬래브의 횡변위 구속에 따른 내력의 변화를 관찰하고자 하였다. 현재 대형 콘크리트 패널구조 수평접합부의 설계에 적용되고 있는 국내 규준식은 국내의 대형 콘크리트 패널구조와는 다소 다른 형태의 실험결과에 의해 유도된 식으로서 그 적용성에 대한 평가가 요망된다. 따라서 본 연구에서는 실험결과를 근거로 이에 대한 평가를 실시할 뿐만 아니라 폐쇄형 수평접합부의 내력을 평가할 수 있는 적합한 이론식을 제시 하였다. 실험결과, 상부 벽판넬의 단면이 결손(10mm)됨에 따라 약 23.5% 내력이 저감되는 것으로 나타났으며, 슬래브 단부형태의 따른 차이와 벽판넬의 단부보강에 따른 내력의 차이, 슬래브의 횡변위 구속 유무에 따른 내력의 차이는 거의 없는 것으로 나타났다. 또한, 제안되 이론식과 실험결과를 비교한 결과 이론식에 의한 결과가 실험결과와 좋은 대응을 보이는 것으로 나타났다.

침엽수 합판의 구조용 및 콘크리트 거푸집용으로서의 성능 평가 (Performance Evaluation of Softwood Plywood as Structural and Concrete-Form Panels)

  • 이전제;김광철;이국식
    • Journal of the Korean Wood Science and Technology
    • /
    • 제28권3호
    • /
    • pp.14-24
    • /
    • 2000
  • 본 연구에서는 향후 공급량이 증가될 것으로 예상되는 라디아타소나무와 국산 낙엽송의 두 수종을 이용하여 합판을 제조하고 구조용 합판 및 콘크리트 거푸집용 합판으로서의 사용 가능성을 검토하고자 하였다. 먼저, 기초적인 재질을 평가하기 위하여 합판의 재질시험 및 못성능 등의 시험을 실시하였고, 콘크리트조 주택 혹은 목조주택 등의 구조용 재료로의 사용을 검토하기 위해 집중하중과 균일분포하중에 의한 구조성능 시험 및 콘크리트 거푸집용으로서의 성능시험을 실시하였다. 합판의 기초 재질에 해당되는 비중, 너비 굽음, 길이 굽음 비틀림에 대한 실험 결과, 구조용 재료로서의 기준을 만족하였다. 못 측면 저항력, 못 인발 저항력 그리고 못머리 관통력에 대한 실험 결과, 구조용 재료로서의 벽체나 지붕재에 대한 표준성능을 만족하였다. 이들 두 수종으로 제조한 합판의 경우, 집중하중과 균일 분포하중에 의한 구조성능 평가, 콘크리트 거푸집용으로서의 성능 평가 결과를 볼 때 구조용 덮개재, 바탕바닥 마감재, 콘크리트 거푸집용 재료로의 사용이 가능하다고 판단되었다.

  • PDF

New Address Electrode Suitable for Fast Addressing with High Xe ac-PDP

  • Lee, Don-Kyu;Lee, Ho-Jun;Lee, Hae-June;Kim, Dong-Hyun;Park, Chung-Hoo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.564-567
    • /
    • 2004
  • New address electrode having separated dual electrode is suggested to reduce addressing time in ac PDP. Addressing characteristics of suggested electrode has been investigated in the test panel with high Xe partial pressure. It has been found that both the formative and jitter width of the suggested electrode is improved by 10 -20 % over the wide range of address voltage level compared with the conventional one. The dynamic margin of the panel also greatly improved. The key feature behind this type of structure is that it can extend the controllability of the wall charge distribution during the reset and address discharge without significant increase in capacitive load of address electrode.

  • PDF

2축 인장을 받는 철근콘크리트 패널의 균열 거동 (Cracking Behavior of RC Panel Subjected to Biaxial Tension)

  • 조재열;조남소;구은숙;김남식;전영선
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.475-480
    • /
    • 2002
  • Tension tests of six half-thickness concrete containment wall elements were conducted as part of a Korea Atomic Energy Research Institute (KARRI) program. The aim of the KAERI test program is providing a test-verified analytical method for estimating capacities of concrete reactor containment buildings under internal overpressurization from postulated degraded core accidents. The data from the tests reported herein should be useful for benchmarking method that requires modeling of material behavior including concrete cracking and reinforcement/concrete interaction exhibited by the test. Major test variable is the compressive strength of concrete and its effect on the behavior of prestressed concrete panel subjected to biaxial tension.

  • PDF

목분의 첨가량에 따른 산화마그네슘 경화체의 밀도 및 흡수율 특성 (Density and Water Absorption Ratio Property of the Magnesium Oxide Matrix According to Wood flour Addition Ratio)

  • 정병열;김헌태;이상수;송하영
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.236-237
    • /
    • 2014
  • Recently, it changes to the frame construction in the wall type structure for the life span improvement of the apartment house of our country. The execution of the light panel increased while the execution of the frame construction increased. Therefore, the density and absorption ratio of the magnesium oxide matrix according to the wood flour amount of addition ratio property try to be analyze for the lightweight of the surface material of the light panel. The test result, the density has been declined as the addition ratio increase of the wood flour. In the case of the water absorption ratio, water absorption ratio has been increased as addition ratio increase of wood flour. However, wood flour addition ratio 15% determined the most appropriate when considering the density and water absorption ratio.

  • PDF

High luminous efficiency AC PDP with the auxiliary electrode

  • Lee, Jae-Hyun;Park, Sang-Dae;Shin, Bhum-Jae;Choi, Kyung-Cheol
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.101-104
    • /
    • 2003
  • The real test panel with the $200{\mu}m$ discharge gap in a coplanar AC plasma display panel was investigated. The auxiliary electrode was placed between two sustain electrodes and used for providing wall charges and prime particle during sustain period. The luminous efficiency had the maximum value when the voltage of the auxiliary pulses was 20 ${\sim}$ 100[V]. The luminous efficiency of coplanar long-gap discharge with auxiliary electrode was 2.6 times as much as that of the conventional structure.

  • PDF

P.C. 대형판 구조물의 수평접합부 유효강성에 대한 정량적 분석 (Quantitative Analysis on Effective Stiffness of Horizontal Joints in Precast Concrete Large Panel Structures)

  • 이한선;장극관;신영식
    • 콘크리트학회지
    • /
    • 제6권3호
    • /
    • pp.142-151
    • /
    • 1994
  • 프리캐스트 콘크리트 대형판 구조물에 있어서 접합부의 강성은 일반적으로 일체식 철근 콘클리트 벽식구조물에 비하여 떨어지는 것으로 알려져있으나 이들 강성에 대한 정량적인 값에 대한 정보가 매우 부족한 실정이다. 이 논문은 몇가지 실험으로부터 도출된 해석적 결과에 근거하여 특히 수평접합부의 압축강도에 관한 정량적 정보를 제공하는 것을 목적으로 한다. 또한 접촉문제로부터의 접근에 의해 구해진 수평접합부의 압축강성값이 위에서 얻은 값들과 매우 유사함을 보여주고 있다.

AC PDP에서의 국부적 패널 온도 변화에 따른 경계 잔상 특징 (The characteristic of boundary image sticking as local temperature variation in panel)

  • 최우성;이지훈;장용민;유수복;이호준;김동현;박정후
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.204-206
    • /
    • 2005
  • Although intensive experiments have been performed to investigate the origin of boundary image sticking, one of major factors to determine display quality in AC PDP, it has not being reported clearly why it is occurred. The relationships between boundary image sticking and its possible origins such as phosphor degradation, temporal change of MgO layer, wall charge have been discussed. In this paper, we have analyzed characteristics of the boundary image sticking more clearly by the influence of local panel temperature.

  • PDF

경량복합패널 심재의 버미큘라이트 첨가율에 따른 밀도 및 열전도율 특성 (Properties of Density and Thermal Conductivity according to Addition ratio of Vermiculite of Lightweight Composite Panel Core)

  • 신진현;김헌태;김태현;이동훈;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 추계 학술논문 발표대회
    • /
    • pp.111-112
    • /
    • 2016
  • Lately, In case of domestic fire situation, Suffocation due to inflammables has shown higher than direct disaster of the fire among the statistics of death caused by disaster. According to study, Lightweight Hybrid Panel as using the inner or outer wall is made with Polysilicon of the inorganic material, PA and vermiculite, so we make progress to performance experiment and review the density, thermal conductivity properties.

  • PDF