• Title/Summary/Keyword: Wall jet region

Search Result 83, Processing Time 0.023 seconds

Numerical Study on Flow Characteristics of Synthetic Jet with Rectangular and Circular Slot Exit (사각형 및 원형 출구 Synthetic Jet의 유동 특성에 대한 수치적 연구)

  • Kim, Min-Hee;Kim, Woo-Re;Kim, Chong-Am;Jung, Kyung-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.7
    • /
    • pp.585-595
    • /
    • 2011
  • The flow characteristics of synthetic jet depending on rectangular and circular jet exit configuration are investigated using numerical computation with cross flow. In rectangular slot, synthetic jet generates the strong vortex but supplies fewer momentum and effectiveness of flow control is reduced along flow direction. In circular slot, regular vortex is formed from slot center to end. It affects the wider region than rectangular slot. The distribution of wall shear stress is considered in order to indicate the effectiveness of flow control device for flow separation delay. Consequently, circular slot is a more suitable candidate for delaying flow separation. In order to derive the optimal shape of a circular slot exit, hole gap and diameter that affect the flow structure and flow control were analyzed. As a result, consider the hole diameter and gap of circular slot exit design, effectiveness of the flow control can be increased.

Characteristic study of fluid flow of laminar impinging jet in an aligned magnetic field (자기장이 인가된 영역에서의 층류 충돌제트의 유동특성 변화에 대한 수치적 연구)

  • Lee, Hyun-Goo;Ha, Man-Yeong;Yoon, Hyun-Sik;Chun, Ho-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1845-1850
    • /
    • 2004
  • The laminar impinging jet flow fields were investigated with or without magnetic fields. The transient phenomenon from steady to unsteady flow was founded at specific Reynolds number ranges. In unsteady flow region, the magnetic fields make flow stable. So the characteristics of fluid flow at impingement wall are changed

  • PDF

Characteristic study of heat transfer of laminar impinging jet in an aligned magnetic field (자기장이 인가된 영역에서의 층류 충돌제트의 열전달특성 변화에 대한 수치적 연구)

  • Lee, Hyun-Goo;Ha, Man-Yeong;Yoon, Hyun-Sik;Chun, Ho-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1447-1451
    • /
    • 2004
  • The laminar impinging jet thermal fields were investigated with or without magnetic fields. The transient phenomenon from steady to unsteady flow was founded at specific Reynolds number ranges. In unsteady flow region, the magnetic fields make flow stable. So the characteristics of heat transfer at impingement wall are changed

  • PDF

Effect of Turbulence Promoter Width on Heat Transfer Augmentation in Impinging Air Jet System (충돌공기분류계(衝突空氣噴流系)에서 난류촉진체(亂流促進體)의 폭변화(幅變化)가 전열증진(傳熱增進)에 미치는 영향(影響))

  • Kum, S.M.;Seo, J.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.4
    • /
    • pp.427-438
    • /
    • 1994
  • This experimental study was earned out to examine the heat transfer characteristics of a 2-dimensional impinging air jet on a flat plate with a set of square rods. The objectives of the study were to investigate the flow and heat transfer characteristics caused by the square rods and to find out the optimum rods arrangement. Experiment was carried out first without using the rods to establish the baseline heat transfer performance. Then, rods of different widths and clearances were installed to cause the turbulence on the fluid flow.

  • PDF

A Study on Heat Transfer Augmentation in Rectangular Impinging Water Jet System (사각(四角) 충돌수분류(衝突水噴流)의 열전달증진(熱傳達增進)에 관(關)한 연구(硏究))

  • Park, S.Y.;Lee, J.S.;Ohm, K.C.;Seo, J.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.1
    • /
    • pp.42-50
    • /
    • 1991
  • The purpose of this study is an augmentation of heat transfer in the case of upward rectangular impinging water jet system. The variables of this study are nozzle-to-heated surface distance, jet velocity and supplementary water height. Optimum heights of supplementary water which augment the heat transfer rate are S/B=2 for H/B=30 and S/B=I for H/B=40, 50. On the Y-direction of nozzle, there exhibits the secondary peak of heat transfer coefficient when supplementary water is not used, however using the supplementary water, it does not exhibits. In the case of using supplementary water, heat transfer coefficient increases not only in stagnation region but also in wall jet region.

  • PDF

Heat Transfer on a Heated Flat Plate by an Impinging Round Jet Using Liquid Crystal (Liquid Crystal을 이용한 원형충돌분류의 전열특성 연구)

  • 오승묵;이상준
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.8
    • /
    • pp.1566-1574
    • /
    • 1992
  • Local heat transfer characteristics for a round air jet impinging normally on a heated flat plate were experimentally investigated. The problem parameters investigated were jet Reynolds number, Re=4000,10000, and 20000, and nozzle-to-plate spacing(L/D) of 2,6, and 10. The temperature variations on the flat uniform heat flux surface were mapped using a thermo-sensitive liquid crytal sheet. The isochromatic images corresponding to the characteristic temperature of liquid crystal were analyzed with the help of a digital image processing system. The local Nusselt number, Nu decreased rapidly in the impingement region and exhibited a similar profiles in the wall jet region independent of the nozzle-to-plate spacing L/D. In the case of large Reynolds number, heat transfer rate (Nu) was proportional to 0.5 power of the Reynolds number. For L/D=2, a secondary peak in the heat transfer rate was seen in the region of X/D=1.5~3 due to the transition from laminar to turbulent boundary layer.

Effect of Inclined Jet on Heat/Mass Transfer for Impingement/Effusion Cooling System (경사제트에 따른 충돌제트/유출냉각에서 열/물질전달 특성)

  • Hong, Sung-Kook;Rhee, Dong-Ho;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.4
    • /
    • pp.283-289
    • /
    • 2008
  • An experimental investigation was conducted to investigate the heat/mass transfer for impingement/effusion cooling system with inclined jet. Jets with inclined angle of 60 are applied to impingement/effusion cooling. At the jet Reynolds number of 10,000, the experiments were carried out for blowing ratios ranging from 0.0 to 1.5. The local heat/mass transfer coefficients on the effusion plate are measured using a naphthalene sublimation method. The result indicates that the inclined jet causes the non-uniform and low heat/mass transfer compared to the vertical jet. At stagnation region, the peak position is shifted from the geometrical center of injection hole due to Coanda effect and its level is higher than that of vertical jet due to increase in turbulence intensity by steep velocity gradient near the stagnation region. Further, the secondary peak region disappears because the interaction between adjacent wall jets weakens. When the initial crossflow occurs, the distorted heat/mass transfer pattern appears. As the blowing ratio (crossflow rate) increases, the heat/mass transfer distributions become similar to those of the vertical jet. This is because the effect of crossflow is dominant compared to that of inclined jet under high blowing ratio $(M{\geq}1.0)$. At low blowing ratio $(M{\leq}0.5)$, averaged Sh value is 10% lower than that of vertical jet, whereas its value at high blowing ratio $(M{\geq}1.0)$ is similar to that of vertical jet.

Turbulence Characteristics of a Three-Dimensional Boundary Layer on a Rotating Disk with an Impinging Jet (II) - Turbulence Statistics - (충돌제트를 갖는 회전원판 위 3차원 경계층의 난류특성 (II) - 난류 통계량 -)

  • Kang, Hyung Suk;Yoo, Jung Yul;Choi, Haecheon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.9
    • /
    • pp.1290-1306
    • /
    • 1998
  • An experimental study has been performed on a three-dimensional boundary layer over a rotating disk with an impinging jet at the center of the disk. The objective of the present study is to investigate the turbulence statistics of the three-dimensional turbulent boundary layer, which may be regarded as one of the simplest models for the flow in turbomachinery. Six components of the Reynolds stresses and ten triple products are measured by aligning the miniature X-wire probe to the mean velocity direction. The ratio of the wall-parallel shear stress magnitude to twice the turbulent kinetic energy in the near-wall region is strongly decreased by the impinging jet. In the case of the free rotating disk flow the shear stress vector lags behind the mean velocity gradient vector in the whole boundary layer, while the lag is weakened as the impinging jet speed increases.

Effect of nozzle geometry on heat transfer of confined slot jet impingement on a flat plate with square rods (사각봉이 배열된 슬롯제트 충돌면에서 노즐형상이 열전달에 미치는 영향)

  • Chung, In-Kee;Park, Si-Woo;Ko, Wan-Wook
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.272-277
    • /
    • 2000
  • The heat transfer characteristics of confined turbulent slot jet impingement on the flat plate with square rods(turbulence promoter) have been experimentally investigated at different nozzle configuration. The effects of jet Reynolds number (Re=3900, 5800, 7800, 9700), dimensionless slot-to-plate distance(H/B=4, 6, 8) and clearance(c) between square rods and the plate were examined. Measurement of heat transfer rate were conducted using naphthalene sublimation technique. When square rods were inserted over the heat transfer surface, heat transfer rate was slightly increased in the wall jet region and the sharp-edged orifice nozzle was heigher than squared orifice nozzle.

  • PDF

Heat Transfer characteristics of distance between impinging surface and a plane jet (평면제트와 충돌면과의 거리변화에 따른 열전달 특성)

  • 김동건
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.5
    • /
    • pp.588-594
    • /
    • 1998
  • Heat transfer characteristics of distance between impinging surface and a plane jet were experi-mentally investigated. The local heat transfer coefficients were measured by a thermochromic liq-uid crystal(TLC) The jet Reynolds number studied was varied over the range from 10,000310 to 30,000310 the nozzle-to-plate distance (H/B) from 4 to 10. It was observed that the Nusselt number increases with Reynolds number the occurrence of the secondary peak in the Nusselt number is within the potential core region the potential core of the jet flow can reach the impinging surface so that the wall jet can a transition from laminar to turbulent flow resulting in a sudden increase in the heat transfer rate.

  • PDF