• Title/Summary/Keyword: Wall following

Search Result 677, Processing Time 0.029 seconds

Radioaerosol Inhalation Imaging in Bronchial Asthma (기관지 천식의 연무흡입 폐환기스캔 소견)

  • Kim, Bum-Soo;Park, Young-Ha;Park, Jeong-Mi;Chung, Myung-Hee;Chung, Soo-Kyo;Shinn, Kyung-Sub;Bahk, Yong-Whee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.1
    • /
    • pp.46-52
    • /
    • 1991
  • Radioaerosol inhalation imaging (RII) has been used in radionuclide pulmonary studies for the past 20 years. The method is well accepted for assessing regional ventilation because of its usefulness, easy fabrication and simple application system. To evaluate its clinical utility in the study of impaired regional ventilation in bronchial asthma, we obtained and analysed RIIs in 31 patients (16 women and 15 men; age ranging 21-76 years) with typical bronchial asthma at the Department of Radiology, Kangnam St. Mary's Hospital, Catholic University Medical college, from January, 1988 to August, 1989. Scintiscans were obtained with radioaerosol produced by a BARC(Bhabha Atomic Reserch Center, India) nebulizer with 15 mCi of $^{99m}Tc-phytate$. The scanning was peformed in anterior, posterior and lateral projections following 5-minute inhalation of radioaerosol on sitting position. The scans were analyzed and correlated with the results of pulmonary function study and the findings of chest radiography. Fifteen patients had concomitant lung perfusion image with $^{99m}Tc-MAA$. Follow-up scans were obtained in 5 patients after bronchodilator therapy. The patients were divided into (1) attack type (4 patients), (2) resistant type (5 patients), (3) remittent type (10 patients) and (4) bronchitic type (12 patients). Chest radiography showed hyperinflation, altered pulmonary vascularity, thickening of the bronchial wall and accentuation of basal interstitial markings in 26 of the 31 patients. Chest radiographs were norma! in the remaining 5 patients. Regardless of type, the findings of RII were basically the same, and characterized by the deposition of radioaerosol in the central parts or in the main respiratory air ways along with mottled nonsegmental ventilation defects in the periphery. Peripheral parenchymal defects were more extensive than that of expected findings from clinical symptoms, pulmonary function test and chest radiograph. Broomstick sign was present in 17 patients. The abnormality of RII was poorly correlated with perfusion scans. In all 5 patients treated with bronchodilators, follow-up study demonstrated a decrease in the degree of radioaerosol deposition in the central air way with improved ventilation defects. This study indicates that RII is a useful technique for the evaluation of regional ventilation abnormality and the effect of treatment with bronchodilators in patients with bronchial asthma.

  • PDF

Induction of Soft Tunic Syndrome by Water Temperature and Physiological and Histological Responses of the Sea Squirt, Halocynthia roretzi (수온에 의한 멍게(Halocynthia roretzi)의 물렁증 유도와 생리 및 조직학적 반응)

  • Shin, Yun Kyung;Park, Jung Jun;Myeong, Jeong In;Kim, Hyejin;Lee, Jung Sick
    • Korean Journal of Environmental Biology
    • /
    • v.32 no.3
    • /
    • pp.225-233
    • /
    • 2014
  • In this study, we investigated the changes in the physiological and histological traits of a sea squirt (Halocynthia roretzi) with the emergence of the soft tunic syndrome induced by the water temperature control (6, 9, 12, 15, 18, 21, 24 and $27^{\circ}C$). It was observed that the induction rate of the soft tunic syndrome was highest at $15^{\circ}C$, but lowest at $24^{\circ}C$. Based on the tunic color condition and contraction strength, the whole process were classified into 4 stages as S0, S1, S2 and S3. Interestingly, there were significant differences in oxygen consumption and filtration rate were observed during S0-S3. The most distinctive aspects were change of blood cell composition at stage S3, whereas multi-vacuole cell ratio was decreased by 1/2 and morula cell ratio expanded about 10 times during S0-S3. Further, change of organ structure started following the syndrome such as degeneration of epithelial cells, microfilaments, increment in hemocytes and damage in muscle fiber have been detected in tunic, siphon, branchial sac, body wall musculature and pyloric gland. Briefly, our study results indicated that the normal physiological functions of the sea squirt can be affected due to the soft tunic syndrome induced by water temperature.

Penetration and Microleakage Assessment of Flowable Resin Applied on Carious Fissure Following Various Fissurotomy Techniques (교합면 우식열구에서 열구성형술 방법에 따른 유동성 레진의 침투도와 미세누출 평가)

  • Kwon, Seok;Lee, Sangho;Lee, Nanyoung;Jih, Meongkwan;Yoon, Youngmi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.45 no.1
    • /
    • pp.90-97
    • /
    • 2018
  • The purpose of this study was to evaluate the effect of fissurotomy on the penetration and microleakage of flowable resins for carious fissures. A total of 250 extracted premolars with early fissure caries were selected and divided into five groups according to the fissurotomy; no fissurotomy (n = 50), fissurotomy with $Fissurotomy^{(R)}$ original bur (n = 50), fissurotomy with $Fissurotomy^{(R)}$ Miro NTF bur (n = 50), fissurotomy with SF104R tapered diamond bur (n = 50), fissurotomy with 1/2 round carbide bur (n = 50). Two types of flowable resins ($UniFil^{(R)}Flow$, $Filtek^{(R)}Flow$) were used as sealing materials. All samples were sectioned and observed using a stereoscopic microscope after thermocycling and immersing in methylene blue solution. The adaptation of flowable resin to the fissure wall was observed using scanning electron microscopy. The penetration of flowable resin into the carious fissure was significantly increased by fissurotomy, which also decreased microleakage. Fissure preparation using different burs showed a significantly different in penetration, but did not show any difference in microleakage. $Unifil^{(R)}Flow$ showed better penetration than $Filtek^{(R)}Flow$, but there was no significant difference in microleakage. Fissurotomy can be used to increase the penetration of flowable resin into carious fissures and decrease microleakage.

ALKALINITY CHANGE IN ROOT DENTIN FOLLOWING CALCIUM HYDROXIDE DRESSING (수종 수산화칼슘 제재를 이용한 근관충전 후 치근상아질에서의 염기도 변화)

  • Lee, Kyung-Ha;Ahn, Yun-Sil;Lee, Kwang-Won;Lee, Myung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.2
    • /
    • pp.670-679
    • /
    • 1997
  • The pH changes in 4 small cavities prepared at the facial inner dentin and lingual outer dentin of the cervical and apical portion of root filled with calcium hydroxide pastes were investigated. Forty extracted permanent teeth with single canal were instrumented with step-back method, and then 4 small cavities were prepared. Two inner dentin cavities were cut a distance of about 1.0mm from the canal wall and two outer dentin cavities were cut to a depth of about 0.5mm from the root surface. Root canals and prepared cavities were flushed with 17% EDTA, and then irrigated with 5% NaOCl to remove smear layer. Teeth were randomly divided into four groups. Control group was not filled and the remaining other groups were filled with mixture of calcium hydroxide and distilled water, Vitapex$^{(R)}$ paste and Pulpdent$^{(R)}$ paste respectively. The pH change of the dentin in each cavity was measured at 0, 1, 3, 7, 14, 21, 28, 60, 90 days with pH microelectrode(WPI Co., USA). The results were as follows : 1. The groups obturated with Pulpdent$^{(R)}$ paste and Aqueous calcium hydroxide produced the increased pH level at 1 day and maintained plateau over next 3weeks and decreased after 3weeks. 2. The group obturated with Vitapex$^{(R)}$ paste observed no significant pH change until 2weeks and slight increased pH at 3weeks and sequential increasing after 3weeks. But, the pH in the group obturated with Vitapex$^{(R)}$ paste remained significantly below the pH measured in the other two experimental groups(P<0.05). 3. All experimental groups showed pH level similar to control group after 28 days. 4. The pH of outer dentin is slightly higher than that of inner dentin. There is no significant difference in pH level between apical and cervical dentin throughout the duration of the experiment, though apical dentin showed slightly higher pH than cervical dentin at 1 day(P<0.05).

  • PDF

Physicochemical Properties of Hull-less Barley Flours Prepared with Different Grinding Mills (제분방법에 따른 쌀보리가루의 이화학적 특성)

  • Lee, Young-Tack;Seog, Ho-Moon;Cho, Mi-Kyung;Kim, Sung-Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.28 no.6
    • /
    • pp.1078-1083
    • /
    • 1996
  • During the pearling process of hull-less barley, protein, lipid, ash and insoluble dietary fiber (IDF) contents decreased, while soluble dietary fiber (SDF) and ${\beta}-glucan$ contents slightly increased. Depending on milling methods and types of grinding mills used, there were differences in particle size distribution of barley flour. Flour particle size was smaller in the following order of Fitz mill, Ball mill, Pin mill, Cyclotec sample mill and Jet mill. Color (brightness) was closely related to the particle size of barley flour. Damaged starch (%) in pearled barley flour was the highest in Jet mill among different mills. Flours prepared with Cyclone mill and Pin mill had a reasonable amount of damaged starch. Flour produced by Fitz mill showed the lowest amount of damaged starch. Scanning electron microscopy (SEM) of the flour samples demonstrated different sizes and shapes of particles consisting of starch granules and cell wall materials. Damaged starch tended to increase water absorption index (WAI), water solubility index (WSI), and water retention capacity (WRC). Pasting viscosity determined by amylograph was relatively high in Pin-milled and Cyclone-milled flours. Viscosity was the lowest in coarsely ground flour by Fits mill.

  • PDF

A Study on the Sludge Reduction and Biogas Production through a Two-phase Anaerobic Digestion Process (이상 혐기성 소화 공정을 통한 슬러지 발생량 저감과 바이오가스 생산에 관한 연구)

  • Woo, Mi-Hee;Han, Gee-Bong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.9
    • /
    • pp.894-899
    • /
    • 2010
  • We coordinated the experiments with ozone pretreatment and two-phase anaerobic digestion using solid-liquid separation to raise the efficiency of sludge volume reduction and obtained the following results. The pre-treatment with ozone reduced the solid concentration in the average of TSS $8.3{\pm}2.0%$ TSS and $9.2{\pm}}2.8%$ VSS. Of the organic material, TCOD decreased $5.1{\pm}2.4%$, but SCOD showed $72{\pm}6.5%$ increased, which was due to destruction of the cell wall and dissolution of icell media by the powerful oxidative stress of ozone. During the two-phase anaerobic digestion process, we achieved the reduction of $21.5{\pm}3.4%$ TSS, $20.2{\pm}8.4%$ VSS, $32.1{\pm}7.9%$ TCOD and $22.1{\pm}7.2%$ SCOD in average. The maximum methane gas production were 177.6 mL per g TSS, 210.8 mL per g VSS, 127.0 mL per g TCOD and 1452.0 mL per g SCOD, respectively. Solid material reduction through the two-phase anaerobic digestion and MLE (Modified Ludzack-Ettinger) processes were 93.8% of TSS and 92.0% of VSS. We concluded that suggested two-phase anaerobic digestion and MLE process could achieve the reasonable production of biogas and a maximum reduction of the sludge volume.

Ridge and field tile aerodynamics for a low-rise building: a full-scale study

  • Tecle, Amanuel;Bitsuamlak, Girma T.;Suskawang, Nakin;Chowdury, Arindam Gan;Fuez, Serge
    • Wind and Structures
    • /
    • v.16 no.4
    • /
    • pp.301-322
    • /
    • 2013
  • Recent major post-hurricane damage assessments in the United States have reported that the most common damages result from the loss of building roof coverings and subsequent wind driven rain intrusion. In an effort to look further into this problem, this paper presents a full-scale (Wall of Wind --WoW--) investigation of external and underneath wind pressures on roof tiles installed on a low-rise building model with various gable roofs. The optimal dimensions for the low-rise building that was tested with the WOW are 2.74 m (9 ft) long, 2.13 m (7 ft) wide, and 2.13 m (7 ft) high. The building is tested with interchangeable gable roofs at three different slopes (2:12; 5:12 and 7:12). The field tiles of these gable roofs are considered with three different tile profiles namely high (HP), medium (MP), and low profiles (LP) in accordance with Florida practice. For the ridge, two different types namely rounded and three-sided tiles were considered. The effect of weather block on the "underneath" pressure that develops between the tiles and the roof deck was also examined. These tests revealed the following: high pressure coefficients for the ridge tile compared to the field tiles, including those located at the corners; considerably higher pressure on the gable end ridge tiles compared to ridge tiles at the middle of the ridge line; and marginally higher pressure on barrel type tiles compared to the three-sided ridge tiles. The weather blocking of clay tiles, while useful in preventing water intrusion, it doesn't have significant effect on the wind loads of the field tiles. The case with weather blocking produces positive mean underneath pressure on the field tiles on the windward side thus reducing the net pressures on the windward surface of the roof. On the leeward side, reductions in net pressure to a non-significant level were observed due to the opposite direction of the internal and external pressures. The effect of the weather blocking on the external pressure on the ridge tile was negligible.

A Study on the Mongolia's Ger and Food in Pastoral Nomadic Way of Life (몽골 유목민의 겔(gel)과 음식문화에 관한 연구)

  • Chang, Bo-Woong
    • Journal of the Korean association of regional geographers
    • /
    • v.3 no.1
    • /
    • pp.155-163
    • /
    • 1997
  • The Mongolian ger is ideally suited to the mongol's steppe climate and the nomadic way of life. This is a multipurpose dwelling which can be easily collapsed, transported to another place and put up again fully preserving its original shape. The pastoral nomadic ger has two key components: the wooden framework and the felt cover. The wooden parts are the walls(khana), the long poles(un), the smoke escape(toono) and its supports(bagana). One wall consists of 10-15 branches of willow tree. each about 1.5m high bound together in a way making it possible to fold it for transportation and then unfold it like an accordion. The unfolded walls are connected to form a circle. The long poles(un) are fastened to the upper part of the walls, with the other end passed through the toono hole, the only sky window and smoke escape through it from the ger. The toono is propped up by two posts, called bagana. All this forms the wooden framework of the ger, which is covered with felt. When the herders fire up their metal stoves, the temperature inside the ger becomes quite comfortable. Because the nomads live in a climate where there is only one growing season in a year, they do not make long migrations to new pastures. Livestock subsist on standing vegetation for eight months of the year. The basic pasture migration strategy is to leave enough standing vegetation at the end of the growing season in September to suffice until the new growth appears the following May. Mongolians use a type of compressed tea leaf that is called "brick" tea in English because it is rock solid and roughly the shape of a brick. And they consume a larger percent(88%) of fat from animal products such as meat, milk, butter, and cheese than any other people in the world. Milk products made from the milk of sheep, yak, and goats are major foods in the nomad's diet, but they are produced mainly in summer when all the animals are lactating. Mongolians made their special nomadic food culture on the steppe.

  • PDF

The Innovative Strategy on the Activation of Marine Tourism in Busan (부산의 해상관광활성화에 관한 혁신적 전략(1))

  • Kim, Jae-Gwan
    • Journal of the Korean association of regional geographers
    • /
    • v.13 no.2
    • /
    • pp.156-170
    • /
    • 2007
  • The commerce and industry of Busan was developed because of good geographical conditions with harbor. After passing its settling-down and diffusing time, Busan has grown in the trade city. Busan has lost the competitive power of the port city since 2000, because of the weakness of its economic power which is caused by the secession of manufacturing industry and the decrease of resident population and foreign tourist. In order to overcome these weaknesses, it is necessary for Busan to take the innovative strategy for the activation of marine tourism. This goal can be achieved by the strong quality of the port city, the coastal terrain, the traditional industry and the international traffic. The aim of this paper is to explore the Innovative Strategy for the activation of marine tourism in Busan and to suggest the following proposal. First, the government must decide the base of marine tourism under the geography viewpoint of the coast and sea, and develope tourism resources after analyzing the identity of marine tourism base. Second, the core part along the selected bases of marine tourism must be constructed the tourism terminal as the landmark of Busan in order to concentrate foreign tourist. Third, after each base of marine tourism must become the resort for tourists, they are able to experience the activity of marine tourism in this resort. Therefore, each base must be specialized. Fourth, each base must be connected with the route of marine tourism Fifth, in order to overcome the off-season of marine tourism, winter tourism goods such as skates, skis, artificial sea-bathing pool, artificial swimming beach, artificial sled, artificial rock wall of coast, hot spring resort of salt water are required to be developed in the center of marine tourism base.

  • PDF

Origin and Preservation Status of the 'Gongju Junghakdong Old Missionary House', the Registered Cultural Property No. 233 (등록문화재 제233호 '공주 중학동 구 선교사가옥'의 유래와 보존현황)

  • Suh, Mancheol;Kim, Sung Bae
    • Journal of Conservation Science
    • /
    • v.34 no.1
    • /
    • pp.11-21
    • /
    • 2018
  • The result of the study on the origin and preservation status of the 'Gongju Junghakdong old missionary house', the Registered Cultural Property No. 233, reveals that the building was approved on October 23, 1921, and missionary Alice H. Sharp was living in the building until her retirement from her missionary life of 39 years in Korea in 1939. In order to review internal and external preservation status of the building, condition of wood material, the composition of the window, the damage of the wall, and the leaning of the building were examined. In particular, in the case of window facilities, it is necessary to restore it to the original upper and lower sliding window. As a result of investigation of the preservation status of the external facilities, it is necessary to restore the original shape of the staircase and a deck of the building on south western side and the well. In addition, the results of the non-destructive diagnosis of the ground revealed that the building was built on uneven surface layer of 2-5 m thickness and the boundary between the surface layer and the upper part of the weathered rock is inclined following geomorphology. This phenomenon shows that when the water content of the ground increases in the rainy season, the bearing capacity of the ground is lowered, and there is a possibility of uneven subsidence. Especially, landslides may occur in case of heavy rain. Therefore, it is desirable to install a masonry facility at the southwest boundary of the site, and it is recommended to install a drainage facility to ensure rapid drainage.