• 제목/요약/키워드: Wall conditioning

검색결과 402건 처리시간 0.032초

건물의 기하학적 형태를 고려한 TRNSYS 모델링 방법 (Modeling Method of the TRNSYS Considering of a Building Geometry)

  • 이재혁;최원기;서승직
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.21-26
    • /
    • 2009
  • TRNSYS 16 had just a wall area and azimuth as an input value about a building shape. So, a geometrical shape of a building was not considered in simulation using TRNSYS 16. In this study, we suggested the more appropriate modeling method for simulation considering of building geometry in TRNSYS 16. To suggest this method, we simulated energy needs affected by shading effect that caused by a geometrical shape of a building, and compared the result to the simulation result of non-shading environment.

  • PDF

공동주택 지하구조물 누수발생 요인에 대한 의견 분석 -설문조사를 중심으로- (An analysis of the Factors Influencing Leakage of Below-Grade Concrete Structures in Residential Buildings -Survey Centered Data-)

  • 안기원;강효진;김수연;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.73-74
    • /
    • 2017
  • Below-grade concrete structure in residential buildings are exposed to various cracking conditions in between installation, construction and usage. Leakage follows the cracks along the exterior wall and floor slabs, and leakage occurring in this conditioning brings about discomfort to the users inside the building. This study analyzes a survey on the causes of leakage in below-grade concrete structure and proposes a solution method.

  • PDF

복합자재에서의 VOCs 방출량 예측에 관한 연구 (Prediction of VOCs Emissions from Multi-layers Materials)

  • 윤창현;권경우;박준석
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.9-14
    • /
    • 2005
  • The purpose of this study is to predict VOCs emission rates from multi-layers materials, which are composed of single-layer materials having various VOCs emission rates, by using effective diffusion coefficients of the single-layer materials. The study was consisted of two parts; the one is the prediction of VOCs emission rates from multi-layer materials through numerical methods. The other is the measurement of VOCs emissions rates of wall composite and floor composite in Mock-up rooms for comparing the prediction and the experiments' values. The results of the study show that the short-term VOCs emission rates of multi-layers materials can be predicted from the effective diffusion coefficients of single materials in odor accuracy.

  • PDF

공동주택 월풀욕조의 소음진동 특성 및 저감 방안 (The properties of noise and vibration in Whirlpool bath and plan for its reduction)

  • 배상환;이병권
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.506-510
    • /
    • 2005
  • This study shows work on the properties of noise and vibration in Whirlpool bath and plan for its reduction. Totally through 3 steps. we found out the properties of noise and vibration. various anti-vibration design for an effeciency test is conducted. By Anti-vibration for the pump causing vibration, about 4dB(A) was reduced. Moreover. by anti-vibration construction fixing the bathtub frame. about 3db(A) could be reduced. In the case of anti-vibration construction about the wall around the bathtub. and spreading damping paint on the bathtub. the noise was reduced.

  • PDF

CFD를 이용한 초고층빌딩 누드 엘리베이터의 온열 및 연돌현상에 관한 연구 (A Study on the Thermal Phenomena and Stack Effect of Nude Elevator Shaft of High Rise Building that used CFD)

  • 박정한
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1059-1064
    • /
    • 2008
  • The present study is to reduce the thermal phenomena and stack effect of nude elevator of the high-rise building used CFD simulation. Since many High-rise buildings used the curtain-wall glass, thermal phenomena and stack effect can easily occur at hot and cold season, respectively. The simulation has been conducted and verified for the effects of the amount of suppling air to the environment of the inside nude elevator shaft. The results of simulations show that the problems due to the thermal and stack effect will be reduced by enforced ventilation or natural ventilation and those will be presented by temperature and velocity profiles and pressure differences.

  • PDF

급기구 형상에 따른 겨울철 실내 온열환경의 비교 (Comparison of Indoor Thermal Environments in Winter depending on Supply Vent Configurations)

  • 한화택;정영균
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.970-975
    • /
    • 2008
  • This study considers indoor thermal comfort in an ondol space by supply vent configurations to prevent cold draft in winter. A specially-designed vent cap has been investigated in comparison with a round pan-type vent and a simple opening without a cap. Numerical simulations have been conducted using CFD to analyze thermal comfort indices such as Predicted Mean Vote (PMV) and Effective Draft Temperature (EDT) as well as air distribution index i.e. Air Diffusion Performance Index (ADPI). Results show the new vent cap provides improved thermal comfort conditions especially near ondol heated floor, as the cold outdoor air spreads upwards along the vertical wall before reaching occupant region near floor. This paper includes discussions on the flow and comfort distributions created by the thermal jets from the vents.

  • PDF

보조 흡입구가 장착된 왕복동 압축기의 성능 분석 (Performance of a Reciprocating Compressor Equipped with Auxiliary Port)

  • 이용호;김현진
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.163-170
    • /
    • 2008
  • Auxiliary port which had been known to be used to reduce the expansion loss of a refrigeration system was applied to a R134a reciprocating compressor in a household refrigerator cycle with an intention of improving the compressor performance. Effects of the auxiliary port on the compressor performance was investigated by a computer simulation program. When a simple hole was made on the side wall of the cylinder as an auxiliary port and surrounding gas inside the compressor shell was assumed to be drawn into the cylinder through the hole, maximum COP improvement of 1.66% was obtained. With auxiliary port equipped with a plate type of check valve, maximum COP was raised to be 1.99%. COP improvement was more distinctive with decreasing the discharge pressure; COP improvement was 5% with discharge pressure of 7 bar.

  • PDF

관류보일러를 위한 예혼합 VIStA 버너 개발 (Premixed VIStA Burner for an Once-Through Type Boiler)

  • 안준;김혁주;최규성
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1013-1018
    • /
    • 2008
  • Vortex Inertial Staged Air (VIStA) burner for an once-through type boiler has been restored to the original premixed type to reduce nitrogen oxide (NOx) emission. The premixed version yields additional de-NOx effect by 20 ppm. The flame is formed closer to the wall at the 1st stage combustion chamber compared with the non-premixed one. The combustion characteristics are more sensitive to the air distribution for the premixed type, which necessitates proper optimization.

  • PDF

Plus50 환경공생빌딩의 열성능 평가에 관한 연구 (A Study on the Assessment of Thermal Performance of Plus50 Eco-building)

  • 이홍철;황인주
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.155-160
    • /
    • 2007
  • This study describes thermal performance of Plus50 eco-building with new technology such as power window system, green wall, structure material, etc. The Plus50 eco-building is house experimental which is constructed by Korea Institute of Construction Technology. In order to estimate thermal performance of the building, TRNSYS program and Prebid, and its sub-modules are used. The results showed that maximum heating and cooling load in the building are calculated at 1st floor and 4th floor, respectively. And also energy saving of the building is calculated as over 30% compared to conventional apartment house.

  • PDF

기능성 골판지 포장재 KS규격표준화연구 (A Study on the KS standardization of functional corrugated fibreboard)

  • 이용무
    • 기술표준
    • /
    • 통권12호
    • /
    • pp.67-78
    • /
    • 2003
  • In order to keep a characteristic corrugated fibreboard of fruits and flowers, temperature and humidity change of corrugated fibreboard are analyzed. According to relative humidity rises at fixed temperature, bursting strength of corrugated fibreboard was fallen and double wall corrugated fibreboard appeared greatly the bursting strength decline rate than double faced corrugated fibreboard and edgewise compressive strength of paper more than humidity 80% in rapidly fall. A column crush test of paper became decrease in the high temperature and ordinary temperature strength did over humidity 70% rapidly fallen and strength decrease happened by low temperature 80% slowly fallen and later rapidly. According to ISO standard temperature humidity conditioning (23$\pm$2 , 50$\pm$2%) change, pulp composition difference as to the ring crush strength of a physical strength and generally compare to KS standard increased 5∼8% for the compressive strength, and wet strength reagent was increased 4% inside and out.

  • PDF