• Title/Summary/Keyword: Wall conditioning

Search Result 402, Processing Time 0.027 seconds

Numerical investigation of Turbulent Flow in $270^{\circ}$ Bend using DES approaches (DES 모형을 이용한 270도 곡관 내 난류유동에 관한 수치해석)

  • Seo, Jeong-Sik;Shin, Jong-Keun;Hong, Seong-Ho;Choi, Young-Don
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.558-563
    • /
    • 2007
  • Detached Eddy Simulation(DES) is performed for turbulent flow of the $270^{\circ}$ bend at a Reynolds number of 56,690. A Fine grid generation is used near a wall in order to satisfy the wall boundary condition of y+<1. Turbulence models adopted for DES and Reynolds Average Navier Stokes(RANS) simulation are SST(Shear Stress Transfort) model. Solutions for both streamwise and circumferential velocity components are compared with the experimental data by Lee for $270^{\circ}$ bend and by Chang for $180^{\circ}$ bend.

  • PDF

An Experimental Study on Insulation and Preventing Condensation Performance of Ventilated Curtain Wall (Mock-up 실험을 통한 통기성 커튼월의 단열 및 결로방지 성능평가)

  • Lee, Mi-Jin;Lee, Sun-Woo;Yeo, Myoung-Souk;Kim, Kwang-Woo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1081-1086
    • /
    • 2006
  • Curtainwall systems has been applied to buildings widely for constructability. However, as cutainwall system include many building materials, they become to damaged vapor barrier and incur condensation. Natural ventilation of an air cavity in a curtainwall is expected to be an prevention of condensation in inner wall and reduce cooling energy in summer. The objective of this experimental study is to evaluating the insulation and condensation Performance of ventilated curtainwall with ventilated cavity depth and ratio of opening area.

  • PDF

Effects of surface radiation on the insulation for mechanical system (표면복사특성이 단열성능에 미치는 영향)

  • Oh, Dong-Eun;Park, Jong-Il;Lee, Min-Woo;Hong, Jin-Kwan;Kang, Byung-Ha;Kim, Suk-Hyun
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1006-1011
    • /
    • 2006
  • In this study, a rational procedures for estimation of insulation thickness for condensation control or personnel protection has been investigated. Both horizontal pipe and vertical wall configuration are included. Design parameters are pipe diameter or, height of the wall, thermal conductivity, emissivity, and operating temperatures. The results Indicated that the surface emissivity plays a very important role in the design of insulation for the purpose of surface temperature control, especially in natural convection situation. radiation heat transfer coefficients for some new insulation material surface, such as elastomers, estimated to be more than 90% of the total surface heat transfer coefficient. Adequate revision of specifications or standards has been also suggested.

  • PDF

Performance Analysis of Combined Passive Solar System for Building South Wall (남측외벽에 적용한 혼합형 태양열시스템의 성능 분석)

  • Yun, Tae-Gyun;Lee, Hyun-Soo;Jang, Hyang-In;Suh, Seung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.2
    • /
    • pp.42-49
    • /
    • 2012
  • In this article, the author carried out a theoretical study on the application techniques of a new Combined Passive Solar System (hereinafter referred to as the CPSS) of direct gain and trombe walls to get quick morning heating and to prevent afternoon overheating for office building. The numerical model proposed in this study can be used for the performance analysis of the CPSS in the winter and summer. Heating and Cooling loads are analysed for building energy consumption reduction using this numerical model. The results indicate that CPSS in the winter and summer modes could provide profitable conditions for improvement of indoor thermal comfort control and energy saving. consequently, the application of CPSS will not lead to significant reductions in the auxiliary air conditioning demand but also realize the environmentally friendly building.

A Study on the Radiation Shielding Analysis for Reinforcing the Hot Cell Regular Concrete Shield Wall (핫셀의 일반 콘크리트 보강을 위한 방사선 차폐해석 연구)

  • 조일제;황용화
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.985-990
    • /
    • 2003
  • In order to demonstrate Advanced Spent Fuel Conditioning Process (ACP), shielding facilities such as hot cell suitable to handling radionuclides and process property will be necessary. But the construction of new facilities needs much money, man-power and time, it is now scheduled to remodel the hot cell, which has already been installed and maintained at Irradiated Material Experiment Facility (IMEF) in the Korea Atomic Energy Research Institute (KAERI). The basic structure and concrete shield wall of hot cell partly have been constructed on the base floor in IMEF building in current status. And hot cell after remodeling will be used for carrying out the lab-scale experiment of ACP. The hot cell was built in accordance with 35 curies of fe-59(1.2 MeV) as design criteria of radiation dose limit. But the radioactive source of ACP is expected to be much higher than design criteria of IMEF, shielding ability of the hot cell in the current status is unsatisfactory to the hot test of ACP. Therefore shield wall shall be reinforced with heavy concrete, steel or lead. In this paper, dose rates are calculated according to ACP source, shielding materials, etc., and reinforcement structures are determined considering the current situation of hot cells, installation of shield windows and the easiness of work.

  • PDF

The Impact of Internal heat gain on heating and Cooling Load in Curtain Wall Office Buildings (커튼월 사무소용 건물에서 실내발열이 냉난방 부하에 미치는 영향)

  • Kim, Jeong-Yoon;Yook, In-Soo;Nam, Hyun-Jin;Lee, Jin-Sung;Kim, Jae-Min;Cho, Soo
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.925-930
    • /
    • 2008
  • As office automation appliances and communication equipments are adopted in office buildings, internal heat gains increase gradually. When making simulation model, internal heat gains are usually set up with standard values or ignored. Therefore, the impact of the internal heat gains has been ignored or not been focused although it is recognised as significant contributor to heating/cooling load of buildings. This study focused on the impact of internal heat gains on curtain wall buildings. the amount and schedules of heat internal gains profiles not only affect the profiles of heating/cooling loads, but also make impact on reducing the effectiveness of high performance glazing systems. It is important to identify internal heat gains profiles before considering the installation of high performance glazing systems.

  • PDF

Characterization of a-C/B:H thin films for KSTAR boronization

  • Sun, Jong-Ho;Hong, Suk-Ho;Woo, Hyun-Jong;Park, Eun-Kyong;Kim, Hye-Ran;Chung, Kyu-Sun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.414-414
    • /
    • 2010
  • KSTAR vacuum vessel has been boronized by carborane ($C_2B_{10}H_{12}$) to reduce various kinds of impurities including carbon and oxygen from the wall, since carborane is solid, non-toxic, non-explosive and is easily evaporated, while diborane ($B_2D_6$) is toxic and explosive. To find the best wall condition for the removal of contaminants before application to KSTAR, various amounts (0.3g, 0.5g, 1g) of carborane are tested in a test chamber, where filament discharge was generated in the mixture of helium and carborane with the same KSTAR target pressure (~ 5 mTorr) from base pressure (${\sim}10^-7\;Torr$). Discharge is performed by a pulse sequence mode with 3 second power on and 5 second power off. Deposited films of a-C/B:H are characterized by ellipsometery, AES and XPS, and are compared with those of KSTAR.

  • PDF