• Title/Summary/Keyword: Wall Jet

Search Result 361, Processing Time 0.022 seconds

Characteristics of Plasma Emission Signals in Fiber Laser Welding of API Steel (II) -The Relationship between Welding Conditions and Emission Signals- (API강재의 파이버레이저 용접시 유기되는 플라즈마의 방사특성 (II) -용접조건과 방사신호의 관련성-)

  • Lee, Chang-Je;Kim, Jong-Do;Kim, Yu-Chan
    • Journal of Welding and Joining
    • /
    • v.30 no.4
    • /
    • pp.24-30
    • /
    • 2012
  • Laser welding by fiber laser accompanied by a lot of spatter and humping bead. This is because the deep and narrow keyhole usually form due to high beam quality. So the weld bead is formed defects, because the plasma jet with a high vapor pressure make the molten pool on keyhole wall scattered. For such a reason, unstable behavior of keyhole is difficult to monitor laser welding by using the laser induced plasma. Mostly, fiber laser welding of thick plates most be influenced by this effect. Therefore, fiber laser welding has been difficult to apply the sole. Thus, laser welding monitoring based on plasma measurements have much difficulty in measurements and analysis of signal. In this study, influence of the plasma emission signal according to welding speed and laser power in fiber laser welding analysed by using RMS and FFT analysis. We can verify that RMS value of the plasma emission signal changes with welding parameters in fiber laser welding, and aspect ratio greater than 1, the peak of FFT frequency had been moved in accordance with welding parameter.

Scramjet Experimental Techniques Using a Shock Tunnel (충격파 터널을 이용한 스크램제트 실험 기술)

  • Yang, Sungmo;Kim, Keunyeong;Chang, Eric Won Keun;Jin, Sangwook;Park, Gisu
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.5
    • /
    • pp.97-106
    • /
    • 2018
  • This paper summarizes the technical difficulties pertaining the double-compression ramp scramjet inlet model testing in a shock tunnel and their corresponding solutions. Four technical difficulties are identified: 1) test facility unstart, 2) flow disturbance and model damage due to the impact of diaphragm debris, 3) lack of fuel jet development due to multiple injection, and 4) short test time. After overcoming the identified technical difficulties, the improved results were confirmed through the results of shadowgraph images and shock tube end wall pressure.

Numerical Investigation of Hydraulic Jump in a Spillway (여수로에서 도수 수치해석 연구)

  • Paik, Joongcheol;Ryu, Yong Uk;Lee, Nam-Ju
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.66-66
    • /
    • 2017
  • Hydraulic jump is typically designed to occur over low-haed dam spillways and weirs in the river. An important engineering application of the hydraulic jump is to dissipate the intense kinetic energy of the flows over such hydraulic structures. Turbulent flow and roller-like vortex riding up the free sureface of the jump cause most of the energy dissipation. We carry out a high resolution three-dimensional numerical simulations of a submerged hydraulic jump in a spillway and compare numerical results with a laboratory measurement obtained by the PIV. The numerical results further show the dynamic behavoirs of the inner and outer layers of the submerged wall-jet and the recirculating roller of the hydraulic jump.

  • PDF

Experimental and Numerical Studies on Application of Industrial Explosives to Explosive Welding, Explosive Forming, Shock Powder Consolidation (산업용 폭약을 이용한 폭발용접, 폭발성형과 충격분말고화에 관한 실험 및 수치해석적 연구)

  • Kim, Young-Kook;Kang, Seong-Seung;Cho, Sang-Ho
    • Tunnel and Underground Space
    • /
    • v.22 no.1
    • /
    • pp.69-76
    • /
    • 2012
  • Theoretical backgrounds on the experimental methods of explosive welding, explosive forming and shock consolidation of powders are introduced. Explosive welding experiments of titanium (Ti) and stainless steel (SUS 304) plate were carried out. It was revealed that a series of waves of metal jet are generated in the contact surface between both materials; and that the optimal collision velocity and collision angle is about 2,100~2,800 m/s and $15{\sim}20^{\circ}$, respectively. Also, explosive forming experiments of Al plate were performed and compared to a conventional press forming method. The results confirmed that the shock-loaded Al plate has a larger curvature deformation than those made using conventional press forming. For shock consolidation of powders, the propagation behaviors of a detonation wave and underwater shock wave generated by explosion of an explosive are investigated by means of numerical calculation. The results revealed that the generation and convergence of reflected waves occur at the wall and center position of water column, and also the peak pressure of the converged reflected waves was 20 GPa which exceeds the detonation pressure. As results from the consolidation experiments of metal/ceramic powders ($Fe_{11.2}La_2O_3Co_{0.7}Si_{1.1}$), shock-consolidated $Fe_{11.2}La_2O_3Co_{0.7}Si_{1.1}$ bulk without cracks was successfully obtained by adapting the suggested water container and strong bonding between powder particles was confirmed through microscopic observations.

Heat Transfer Characteristics of Water Jet Impinging on Oblique Surface (경사면(傾斜面)에 충돌(衝突) 하는 수분류(水噴流)의 열전달(熱傳達) 특성(特性)에 관(關)한 연구(硏究))

  • Choi, Guk-Gwang;Na, Gi-Dae;Kim, Yeun-Young;Jeon, Sung-Taek;Lee, Jong-Su
    • Solar Energy
    • /
    • v.13 no.1
    • /
    • pp.1-10
    • /
    • 1993
  • The purpose of this research is to investigate the characteristics of heat transfer in the downward axisymmetric free water jet system impinged on a flat oblique plate which has the uniform heat flux. Experimental conditions considered were Reynolds number, distance between nozzle and Bat plate, inclination angle of heater surface and nozzle exit velocity. Local Nusselt number was subjected to the influence of Re number, Pr number, oblique angle of heating surface and local position of flat plate. In the wall region of downward surface, The secondary peak point of heat transfer appeared at the local point of X/D=-8 from the stagnation point. The stagnation heat transfer rate of this experimental study augments 2.4 times than that of laminar theorical solution. The stagnation nusselt number is function of Reynolds number, nozzle-plate spacing Prandtl number and oblique angle of impinging plate.

  • PDF

A Study on the Damages of Head Works by the Storm Flood in the Area of Cheong Ju and Boeun -Emphasis onFactors Influenced on the Disasters and their Countermeasures- (淸州 및 報恩地方의 頭首工洪水災害에 關한 調査硏究(II) -災害原因 및 對策方案을 中心으로-)

  • Nam, Seong-Woo;Kim, Choul-Kee
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.24 no.2
    • /
    • pp.49-55
    • /
    • 1982
  • The purpose of this study is to classify the factors influenced on the damages of head works suffered from the storm flood occurred on July 22 1980 in both Musim and Bochong rivers and to find out an integral counter measures against the causes influenced on the disaster of head works in the engineering aspect of planning, design, construction and maintenance. In this survey, number of samples was taken 25 head Works, and the counter measures against the causes of their disasters summarized was as follows, 1. In the aspect of planning a. As the flood water level after the establishment of head works is more increased than the level before setting of head works owing to having more gentle slope of river bed between the head works than nature slope of river bed. Number of head works should be reduced for the appropriate annexation of them b. In the place where head works is established on the curved point of levee, the destruction of levee becomes severe by the strong deflective current. Therefore the setting of head works on the curved point should be kept off as long as possible and in case of unavoidable circumstances the construction method such as reinforced concrete wall or stone wall filed with concrete and anchored bank revetments should be considered. 2. In the aspect of design a. As scoring phenomena at up stream is serious around the weir Where the concentration of strong current is present in such a place, up stream apron having impermeability should be designed to resist and prevent scoring. b. As the length of apron and protected bed is too short to prevent scoring as down stream bed, the design length should be taken somewhat more than the calculated value, but in the case the calculated length becomes too long to be profitable, a device of water cushion should be considered. c. The structure of protected river bed should be improved to make stone mesh bags fixed to apron and to have vinyl mattress laid on river bed together with the improvement for increasing the stability of stone mesh bags and preventing the sucked sand from the river bed. d. As the shortage of cut-off length, especialy in case of the cutoffs conneting both shore sides of river makes the cause of destruction of embankment and weir body, the culculation of cut-off length should be taken enough length based on seepage length. 3. In the aspect of design and constructions a. The overturing destruction of weir by piping action was based on the jet water through cracks at the construction and expansion joints. therefore the expansion joint should be designed and constructed with the insertion of water proof plate and asphalt filling, and the construction joint, with concaved shape structure and steel reinforcement. b. As the wrong design and construction of the weep holes on apron will cause water piping and weir destruction, the design and construction of filter based on the rule of filter should be kept for weep holes. c. The wrong design and construction of bank revetment caused the severe destruction of levee and weir body resulting from scoring and impulse by strong current and formation of water route behind the revetment. Therefore bank revetment should be designod and constructed with stone wall filled with concrete and anchored, or reinforced concrete wall to prevent the formation of water flow route behind the wall and to resist against the scoring and impulse of strong stream. 4. In the aspect of maintenance When the damaged parts occurred at head works the authorities and farmers concerned should find and mend them as soon as possible with mutual cooperation, and on the other hand public citizen should be guided for good use of public property.

  • PDF

Hydrodynamic Characteristics of Self-expandable Graft Stents in Steady Flow (정상유동에서 자가팽창성 그래프트 스텐트의 수력학적 특성)

  • 이홍철;김철생;박복춘;박복춘
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.1
    • /
    • pp.37-44
    • /
    • 2003
  • This experimental study is aimed at evaluating the hydrodynamic performance of newly designed self-expandable graft stents under steady flow condition. Two graft stents with different coating materials and a bare TiNi metallic stent for comparison test were used in the experiment. Pressure variation and velocity distribution at the upstream and downstream of the stents were measured at flow rates of 5, 10, and 15 l/min, respectively. Pressure loss due to insertion of the stent increased with increasing flow rate exponentially as expected. At a flow rate of 15 l/min, pressure loss of Polyure-thane(PU)-coated graft stent was 6 times higher than that of TiNi metallic stent, while the pressure loss of a porous Polytetrafluoroethylene(PTFE)-coated graft stent was comparable to a bare TiNi metallic stent. Velocity profiles of the porous PTFE-coated graft stent were similar to those of a bare TiNi metallic stent regardless of flow rate. Furthermore, the velocity profile of PU-coated graft stent revealed an asymmetrical and relatively low central velocity at a higher flow rate than 10 1/min, expecially, where the effects resulted in increases of wall shear stress and normal stress. The worse hydrodynamic behavior of PU-coated graft stent than the other two stents might be attributed to formation of folds due to poor flexibility of coated material when inserting the graft stent into the pipe with a more smaller size, which later gave rise non-symmetry of flow area, increase of surface roughness and jet flow via the crevice between the stent and cylinder wall.

Improvement of Rectangle Sedimentation basin using the Moving Baffle (이동식 정류장치를 이용한 횡류식 침전지 침전효율 개선 연구)

  • Cho, Young-Man
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.7
    • /
    • pp.726-731
    • /
    • 2005
  • Sedimentation is treated as the most important unit process in waterworks, and plays great role on turbidity removal efficiency. Rectangle sedimentation basin is the most widely accepted sedimentation process. But it has some problems with short-circuit flow and density flow caused by temperature and influent turbidity variation. To solve these problems, installation of rectification wall was suggested, but not generally fully accepted in field. Because hole of rectification wall cause jet flow. In this research, use of moving baffle was investigated. Moving baffle was designed to induce uniform velocity at every section of water flow. The baffle walls was made from soft fiber materials. The baffle walls with flow of sedimentation basin moves at same speed. It is like that it controls density flow and short-circuit flow and induce uniform velocity at every section of water flow in sedimentation basin. When moving baffle was operated retention time of sedimentation basin was extended to 1 hours. When it talked again and the effluent time of highest concentration of the chlorine ion from 100 minutes was extended to 160 minutes. Turbidity removal efficiency was tested with different operation modes(continuous and batch) with influent turbidity and retention time. It was revealed that turbidity removal efficiency carl be improved up to 36%(continuous mode) and 58%(batch mode) respectively. Consequently if moving baffle introduces in Rectangle sedimentation basin, it forecasts that the turbidity improvement above 30% will be possible.

A Study on the MESG of Flammable Ternary Gas Mixtures (3성분계 인화성 혼합가스의 MESG에 관한 연구)

  • Hwang, Kyungyong;Byeon, Junghwan;Rhee, Kyunam;Lee, Taeck-Kie
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.3
    • /
    • pp.30-37
    • /
    • 2016
  • Electrical apparatuses for use in the presence of flammable gas atmospheres have to be specially designed to prevent them from igniting the explosive gas. Flameproof design implies that electrical components producing electrical sparks are contained in enclosures and withstand the maximum pressure of internal gas or vapours. In addition, any gaps in the enclosure wall have to designed in such a way that they will not transmit a gas explosion inside the enclosure to an explosive gas or vapours atmosphere outside it. In this study, we explained some of the most important physical mechanism of MESG(Maximum Experimental Safe Gap) that the jet of combustion products ejected through the flame gap to the external surroundings do not have an energy and temperature large enough to initiate an ignition of external gas or vapours. We measured the MESG and maximum explosion pressure of ternary gas mixtures(propane-acetylene-air) by the test method and procedure of IEC 60079-20-1:2010. As a result, the composition of propane gas that has lower explosive power than acetylene gas in the ternary gas mixtures makes greater effects on MESG and explosion pressure.

An Experimental Study of Film Cooling Characteristics at Supersonic Free Stream Conditions (초음속 주유동 환경에서의 막냉각 특성 시험 연구)

  • Kim, Manshik;Lee, Dong Min
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.4
    • /
    • pp.342-348
    • /
    • 2017
  • In this paper, film cooling characteristics at supersonic free stream conditions were examined experimentally by applying an IR-thermography. Film cooling experiments were carried out in a free-jet facility at Mach number of 3.0 and with unit Reynolds number of $42.53{\times}10^6$ and $69.35{\times}10^6$ using wedge shaped film cooling model which has a converging film cooling nozzle. Film cooling efficiency was calculated by measuring the surface temperature of PEEK(Polyether Ether Ketone) and the effects of angle of attack and blowing ratios on the film cooling efficiency were examined. The measured wall temperature was significantly reduced by the film cooling flow compared with the results without the film cooling flow. The usefulness of film cooling was also confirmed by the surface heat flux calculated using the surface temperature history of PEEK. As the blowing ratio increases the protected area of PEEK was also expanded along the direction of free stream and film cooling flow.