터널화재유동의 역기류 해석을 위한 LES 및 RANS 결과의 비교 고찰 (Comparative Study on The Numerical Simulation for The Back-Layer of The Tunnel Fire-Driven Flow with LES and RANS)

  • 장용준;김학범;김진호;한석윤
    • 대한기계학회논문집B
    • /
    • 제33권3호
    • /
    • pp.156-163
    • /
    • 2009
  • In this study, comparative analysis on the back-layer phenomena in the tunnel-fire driven flow is performed using numerical simulation with LES and RANS. FDS(Fire Dynamics Simulator) code is employed to calculate the fire-driven turbulent flow for LES and Smartfire code is used for RANS. Hwang and Wargo's data of scaling tunnel fire experiment are employed to compare with the present numerical simulation. The modeled tunnel is 5.4m(L) ${\times}$ 0.4m(W) ${\times}$ 0.3m(H). Heat Release Rate (HRR) of fire is 3.3kW and ventilation-velocity is 0.33m/s in the main stream. The various grid-distributions are systematically tested with FDS code to analyze the effects of grid size. The LES method with FDS provides an improved back-layer flow behavior in comparison with the RANS (${\kappa}-{\epsilon}$) method by Smartfire. The FDS solvers, however, overpredict the velocity in the center region of flow which is caused by the defects in the tunnel-entrance turbulence strength and in the near-wall turbulent flow in FDS code.

수직 배연구의 자연배연 성능에 관한 수치해석연구 (A Numerical Study for the Performance of Natural Smoke-venting of a Vertical Vent)

  • 전흥균;최영상;추홍록
    • 한국화재소방학회논문지
    • /
    • 제22권4호
    • /
    • pp.1-10
    • /
    • 2008
  • 본 연구에서는 미국 NFPA 204 기준에 의해 설계된 수직 배연구에 대하여 배연구의 위치, 외기 온도, 풍속 및 화재크기가 자연배연 성능에 미치는 영향과 화재특성을 CFAST 프로그램을 사용하여 수치 해석적으로 조사하였다. 배연구는 외벽의 최고 상부에 위치한 경우와 외기온도가 낮은 경우 및 풍속이 작은 경우 배연성능기준을 만족하였다. 또 화재크기가 클수록 배출량은 증가하나 연기층 높이는 낮아져 배연성능기준을 만족하지 못하였다. 직접 외기와 통하는 수직 자연배연구의 설계시 해당지역의 최고 온도와 최대 풍속을 고려하고, 설계화재를 정확히 결정하여 배연성능기준이 만족되도록 주의가 요망된다.

소형선박 기관실화재에 대한 자동소화시스템 개발연구 (Development of Fire Extinguishing System Suitable for Unmanned Engine Room of a Small Ship)

  • 김동석;곽지현;강대선;손봉세
    • 한국화재소방학회논문지
    • /
    • 제20권3호
    • /
    • pp.96-100
    • /
    • 2006
  • 소형선박의 기관실을 상사한 모형실에서 분말소화설비의 개발을 위한 화재시험을 수행하였다. 화재시험이 수행된 모형실은 $2.9m^3,\;4.5m^3,\;8m^3$ 3종류였으며 각 모형실에는 개구부와 송풍용 팬이 설치되었다. 경유를 소화모형의 연료로 사용하였다. 또한 소화약제 방출용 노즐은 천장에서는 하향으로 벽 또는 벽의 모서리에서는 수평으로 분사되도록 설치하였다. 개발제품은 모든 소화모형을 분말소화약제 방출 중에 소화하였으며 소화 후 재발화가 없었다.

국내 건축용 유리 및 커튼월의 안전 기준 개선 방향에 관한 연구(II) (The Approach Methods of Improvement of Safety Standard for Architectural Glass and Curtain Wall)

  • 서윤정;서동구;신이철;김동은;권영진
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2010년도 추계학술발표회 자료집
    • /
    • pp.25-28
    • /
    • 2010
  • 최근 건축물의 초고층화에 따른 커튼월 시공에 따라 유리의 비중이 증가하고 있으나 커튼월 구조는 바람, 지진, 화재에 있어서 취약할 것이라 판단되어 국내외 건축용 유리 및 커튼월의 안전기준에 대한 조사를 실시하였다. 그 결과, 국내의 유리 기준은 단열 및 내풍압 성능에만 집중되어있으며 화재 및 지진, 안전 성능에 대한 기준이 미비한 실정이다. 따라서 국내에 적합한 유리 안전성 평가 프로세스를 구축하기 위한 기초 데이터를 마련하기 위해 유리 내화 실험을 시행하였다. 실험 결과, 일반유리, 복층유리, 강화유리, 접합유리 순의 파열 시간을 가지는 것을 알 수 있었으나 시험체 4개가 화재 초기에 파열되는 것으로 나타나 상층부로의 수직 화재 확대 위험성이 높을 것으로 판단된다.

  • PDF

FDS를 사용한 수직벽화재 시뮬레이션의 문제점 (Shortcommings in Simulation of a Vertical Wall Fire by Using FDS)

  • 박외철
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.68-75
    • /
    • 2008
  • 화재시뮬레이션용 소프트웨어인 FDS (Fire Dynamics Simulator)의 수직벽 화재 시뮬레이션에 있어서의 문제점을 파악하기 위해, 수직벽 프로필렌 화재에 대한 시뮬레이션을 수행하였다. 성능기반설계 등에 널리 사용되고 있는 이 전산유체역학 모델에 포함되어있는 주요 매개변수의 기본값을 사용한 경우, 수직벽 화재에서는 정확도가 매우 낮음을 확인하였다. 프로필렌 연소율 $10.08g/m^2$-s과 $29.29g/m^2$-s에 대한 주요 매개변수의 조사를 수행한 결과, 스마고린스키 상수(Smagorinsky constant)가 기본값인 0.2에서 수직벽에 형성된 경계층이 층류로 예측되었다. 스마고린스키 상수가 0.1일 때 온도분포가 실험과 비교적 잘 일치하였으나 벽면에서의 열유속에는 큰 오차가 있음을 확인하였다.

  • PDF

가연성 단열재를 사용한 외단열 도시형 생활주택의 방화를 위한 보강재 검토 (Examined of reinforcement for the fire protection of the outside insulation Urbantype Housing with flammable insulation material)

  • 이광희;정의인;김봉주
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 추계 학술논문 발표대회
    • /
    • pp.28-29
    • /
    • 2015
  • Due to the big fire in Uijeongbu, the status of construction, fireproof materials and structural method were examined to prevent fire propagation through outside insulation parts of urban living homes. Through research and experiments, the following results were obtained. It was confirmed that outside heat-insulation wall method was used in a large number of urban living homes which were made of materials and structures spreading fire easily.Through experiments, it was revealed that lightweight plate material, as a fireproof material, can save the cost as well as the period of construction and obtain more than 30 minutes of evacuation time which is twice the maximum evacuation time.

  • PDF

무인기관실의 효과적인 자동소화장치 개발 연구 (A Study on the Development of Fire Extinguishing System for Machinery Spaces of Small craft)

  • 강대선;이찬재;김동석;곽지현
    • 선박안전
    • /
    • 통권21호
    • /
    • pp.15-30
    • /
    • 2006
  • A study developing the dry powder fire extinguishing system inside the simulated machinery spaces of small boats was performed. Fire tests were conducted inside the compartments having volumes 2.9, 4.5, 8㎥ respectively. The openings and fans were estavlished on the walls of the compartments. Diesel oil was used for the test ruel, In addition fire extinguishing nozzles using dry powder were installed downward at ceiling and horizontally at the wall or conner. All fires in the test were extinguished under system activation and there was no reignition.

  • PDF

Characterization of Burned Architectural Woods by Fire Using SEM-EDXS and Computerized Tomography

  • Lee, Hyun-Mi;Hwang, Won-Joung;Lee, Dong-Heub;Son, Dong-Won
    • Journal of the Korean Wood Science and Technology
    • /
    • 제42권5호
    • /
    • pp.516-522
    • /
    • 2014
  • Old architectural wood materials damaged by a fire were evaluated on the basis of wood species and scanning electron microscopy (SEM) observation of wood tissues in combination with energy dispersive X-ray spectroscopy (EDXS) analysis. Results of SEM observation showed that tracheid wall thickness of burned parts was very thin compared with undamaged and sound wood, and tylosoid in the resin canals disappeared after the exposure to fire. SEM-EDXS analysis indicated that carbon and oxygen peaks occurred in the original energy band, and the carbon peak was higher than that of the oxygen in the burned part. A computerized tomography was also undertaken to investigate the carbonization layer formed by fire and possible internal defects.

커튼월의 박스형 선형조인트 내화충전시스템의 내화성능 (Fire Resistance Performance of Box Type Linear Joint Fire Stop System for Curtain Wall)

  • 여인환;조경숙
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2011년도 춘계학술논문발표회 논문집
    • /
    • pp.357-360
    • /
    • 2011
  • 고층 건축물에 주로 사용되는 커튼월의 경우 구조체와의 접합으로 인해 층간 틈새가 발생하게 되고 이는 화재 시 틈새를 통해 화염이나 연기 등의 확산 경로가 될 수 있다. 본 연구에서는 커튼월 시스템에 적용되는 선형조인트 내화충전시스템의 개발을 위해 경제적이고 시공이 간편한 박스형 시스템을 도입하고 내부에 다양한 변경하여 내화성능을 평가하였으며, 그 결과 케이싱 내부의 단열재 20mm두께의 내화 뿜칠재와 석고보드를 케이싱 안쪽에 박스 형태로 구성한 시스템이 가장 안정적이고 온도상승도 작은 것으로 나타났다.

  • PDF

케이블 관통부의 유기 팽창물을 이용한 밀폐재 내화성 특성 평가 (The Characteristic Evaluation of Fire-Resistance test by Cable Transit For Organic Expansion Sealing material)

  • 임성식;기명석;정혁;소병기;장기훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.198-199
    • /
    • 2007
  • The Cable Transit has an adaptable center hole for accommodating a cable to be passed through the wall(bulkhead/deck). The Cable Transits Sealing System must have important character which seal and protect against fire, smoke, gas, water, etc and consist of natal frame, sealing system and the cable, insulation. In this paper, introduced our cable transit organic expansion sealing material system, fire-resistance test and test result, etc. We carry to fire-resistance test in according to FTP Code Part 3(IMO Res. A. 754(18)) for A-60 class cable transit and the test result for our cable transit sealing system was satisfied.