• 제목/요약/키워드: WH

검색결과 855건 처리시간 0.024초

히트펌프를 이용한 농산물 건조 및 저온저장 시스템 (I) - 건조 성능 - (Drying and Low Temperature Storage System for Agricultural Products Using the Air to Air Heat Pump (I) - Drying Performance -)

  • 강연구;한충수;금동혁
    • Journal of Biosystems Engineering
    • /
    • 제32권1호
    • /
    • pp.20-29
    • /
    • 2007
  • Korean farmers have purchased agricultural dryer and low temperature storage system apart. In this study, the system was designed and constructed to investigate the practical application possibility of the air to air heat pump as drying and low temperature storage system for agricultural products with providing basic data. The performance and drying characteristics of the system evaluated by drying red pepper. The value of coefficient of performance of the system for heating was from 1.8 to 2.2 when ambient air temperature varied from 13$^{\circ}C$ to 23$^{\circ}C$. For operating the heat pump as dryer for drying red pepper by setting three drying air temperature of 50, 55 and 60$^{\circ}C$, specific moisture extraction rates meaning amount of energy consumption for removing moisture of 1kg from red pepper were 1.095, 1.017 and 1.094 kg$_{water}$/kWh, respectively. The drying period up to moisture ratio of 0.02 were 31, 26 and 21 hour, respectively. The lightness, redness, yellowness and chroma differences of red pepper dried by the heat pump dryer were lowered than those of red pepper dried by conventional heated air dryer except for yellowness difference at drying air temperature of 60$^{\circ}C$.

수직축 풍력 터빈 블레이드의 최적화 설계 및 Vortex 구조 분석 (Optimized blade of small vertical axis wind turbine and its vortex structure analysis)

  • 나지성;고승철;선상규;방유석;이준상
    • 한국가시화정보학회지
    • /
    • 제13권1호
    • /
    • pp.15-20
    • /
    • 2015
  • Sensitivity studies of blade angle and twisted angle are numerically investigated to optimize the Savonius blade. As blade angle increases, the contact area between blade and wind decreases, showing the suppression of the vortex generation near blade. Compared to the blade angle of 0 degree, the blade angle of 20 degree shows about 2.6% increment of power efficiency. Based on the blade angle of 20 degree, sensitivity studies of the twisted angle are performed. The result indicates that the adjustment of the twisted angle causes the torque of blade to increase. Optimized blade can suppress the formation of the vortex structure in rear region. Also, wind flows without disturbance of vortex when passing through the optimized blade. The 1kw vertical wind turbine system with optimized blade can generate 4442.2kWh per year and have 53% capacity factor.

역삼투-압력지연삼투 조합공정 공정모사 및 비용예측 프로그램 개발 (Development of SWRO-PRO hybrid process simulation and cost estimation program)

  • 최용준;신용현;이상호;김승현
    • 상하수도학회지
    • /
    • 제30권3호
    • /
    • pp.299-312
    • /
    • 2016
  • The main objective of this paper is to develop computer simulation program for performance evaluation and cost estimation of a reverse osmosis (RO) and pressure-retarded osmosis (PRO) hybrid process to propose guidelines for its economic competitiveness use in the field. A solution-diffusion model modified with film theory and a simple cost model was applied to the simulation program. Using the simulation program, the effects of various factors, including the Operating conditions, membrane properties, and cost parameters on the RO and RO-PRO hybrid process performance and cost were examined. The simulation results showed that the RO-PRO hybrid process can be economically competitive with the RO process when electricity cost is more than 0.2 $/kWh, the PRO membrane cost is same as RO membrane cost, the power density is more than $8W/m^2$ and PRO recovery is same as 1/(1-RO recovery).

배관 해석 프로그램을 통한 해수담수화 플랜트 수압 시스템 분석 (Analysis of hydraulic system for seawater desalination plant through piping analysis program)

  • 최지혁;최용준;양흥식;이상호;최준석
    • 상하수도학회지
    • /
    • 제34권3호
    • /
    • pp.221-230
    • /
    • 2020
  • In actual seawater desalination plant, the pressure loss due to frictional force of pipe is about 3~5 bar. Also, the pressure loss at pipe connection about 1~3 bar. Therefore, the total pressure loss in the pipe is expected to be about 4~8 bar, which translates into 0.111 to 0.222 kWh/㎥ of energy when converted into the Specific Energy Consumption(SEC). Reducing energy consumption is the most important factor in ensuring the economics of seawater desalination processes, but pressure loss in piping is often not considered in plant design. It is difficult to prevent pressure loss due to friction inside the pipe, but pressure loss at the pipe connection can be reduced by proper pipe design. In this study, seawater desalination plant piping analysis was performed using a commercial network program. The pressure loss and SEC for each case were calculated and compared by seawater desalination plant size.

풍력발전 경제성 분석과 수치최적화방법을 이용한 육상풍력발전시스템 크기 최적선정 연구 (Optimum Dimension Selection of Onshore Wind Power System Using Economic Analysis and Numerical Optimization Technique)

  • 이기학;박종포;이동호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.36.1-36.1
    • /
    • 2011
  • 풍력개발 기술이 발전함에 따라 풍력발전시스템이 점차 대용량화되는 추세이며, 경제성 있는 풍력단지 건설을 위해 점차 대단지화 되어가고 있는 실정이다. 이로 인해 풍력 발전단가(Cost of electricity, COE)도 개선되고 있다. 풍황이 양호한 풍력발전단지의 경우, 풍력발전 COE는 현재 50~60원/kWh 수준으로 타 신재생에너지원에 비해 경쟁력이 높고, 석탄 화력의 COE와 비교해 봐도 동등한 수준 혹은 더욱 경쟁력 있는 수준으로 감소하였다. 풍력발전단지 조성을 위해서는 시스템의 효율과 고효율, 저비용의 풍력발전시스템을 풍황이 좋은 지역에 설치할 때 낮은 COE를 가지는 경제성 있는 발전단지가 가능하다. 동급 용량 풍력발전시스템을 같은 지역에서 설치하여 에너지생산량을 증대시키기 위해서는 블레이드 지름의 증가시켜 유량을 증가시키거나 타워의 높이를 증가시켜 풍속을 증가시키는 방안이 있다. 이 경우 블레이드 길이와 타워 높이 증가에 의한 시스템 비용의 증가가 발생하는데, 에너지생산량 증가에 의한 수익비용과 시스템 비용 증가에 의한 자본비용은 서로 반비례로 영향을 미친다. 이를 위해 최소의 COE의 최대의 순현재가치(Net Present Value, NPV)를 갖는 목적함수로 두고 블레이드의 최적 길이와 타워의 최적 높이를 선정하였다.

  • PDF

CdTe 태양광 발전 시스템의 전과정평가 (Life Cycle Assessment of CdTe Photovoltaic System)

  • 김연희;허진호;정재우;강정림;최종두
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.54.1-54.1
    • /
    • 2011
  • The conventional energy-production system by burning fossil fuels releases many pollutants and carbon dioxide($CO_2$) to the environment. Therefore, many countries pay attention to new and renewable energy and invest in the development of these new technologies for the future energy security. One of the most promising of these technologies is a photovoltaic system. In this study, Life Cycle Assessment(LCA) is carried out to analyse the environmental issues(e.g. global warming, abiotic resource depletion) of CdTe photovoltaic system. The spatial and temporal scope of this study was set in Korea during 2004~2005. We assumed that CdTe photovoltaic system was installed in Mokpo where the amount of solar irradiation was higher than other places in Korea. Based on the present data and some assumptions, greenhouse gas emission was 39.2g $CO_2$-eq./kWh. Therefore the electricity produced by CdTe photovoltaic system is more environmentally friendly than the conventional power generation system.

  • PDF

하이브리드 태양광 LED 가로등 컨트롤러의 효율 개선 (Improve the Efficiency of Hybrid Solar LED Street Lamp Controller)

  • 윤중현;김진사
    • 한국전기전자재료학회논문지
    • /
    • 제28권2호
    • /
    • pp.131-136
    • /
    • 2015
  • We develop the 60 W class hybrid solar LED street lamp controller. The controller is providing power via an inverter in the day with the least solar cell and battery and charging the battery for the ESS, acts as a power failure, the built-in battery. Rated output of the fabricated LED street lamp is 300 W or greater battery capacity 300 Wh, discharge time 10 hr, LED street lamp efficiency showed a very high level of light efficiency by about 127 lm/W. In addition, as a result of light distribution pattern according to the distance and the light intensity measurement will be able to ensure a very high quality, show the constant brightness in the distance from the road lights 6 m is about 35~40 lux in uniformity ratio. The proposed hybrid solar LED street lamp system showed a high energy capacity of approximately 1.5 to 152.7% power generation efficiency than typical conventional solar street lamp.

남한의 태양에너지 자원 정밀조사 (A Detailed Investigation of Solar Radiation Resources in South Korea)

  • 조덕기;윤창열;김광득;강용혁
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.59-62
    • /
    • 2011
  • The Korea Institute of Energy Research(KIER) has begun collecting horizontal global insolation data since May, 1982 at 16 different locations in Korea and for the more detailed analysis, images taken by geostationary satellite may be used to estimate solar irradiance fluxes at earth I s surface. It is based on the empirical correlation between a satellite derived cloud index and the irradiance at the ground. From the results, the measured data has been collected at 16 different stations and estimated using satellite at 23 different stations over the South Korea from 1982 to 2000. The Result of analysis shows that the armual-average daily global radiation on the horizontal surface is $3.56kWh/m^2/day$ and Estimated solar radiation fluxes show reliable results for estimating the global radiation with average deviation of -7.27 to +3.65% from the measured values.

  • PDF

Glazing 특성에 따른 고층 오피스 건물의 에너지성능 분석 (The Analysis on Energy Performance according to Characteristics of Glazing in High-rise Office Buildings)

  • 황우진;김교준;최원기
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.156-161
    • /
    • 2011
  • In case of newly constructed buildings, the construction type is almost Curtain-wall system or large window in building skin. However, these kind of buildings have problems with regulations on building energy efficiency. And national regulations on building energy efficiency limit only the V-factor of window(except infiltration), it is hard to predict energy consumption of Curtain-wall buildings which gain large solar energy in summer. In this study, the influence of LSG(Light to Solar Gain) on energy performance was theoretically analyzed with simulation. LSG is the value of VLT divide SHGC and represents the optical performance of the glass or glazing. The Window & Therm program developed in LBNL was used to analyze window systems and EnergyPlus was used to building energy. Cases of glazing are three types; single coated Low-e clear glazing, tripple coated Low-e clear glazing, tripple coated Low-e tinted glazing. The results of this study are follows; 1) The building energy consumption of Alt-l, 2, 3 were about 300, 253, $259kWh/m^2{\cdot}yr$ respectively. Therefore, improvement of LSG could save the energy up to 16%. 2) The saved energy could be converted 1 billion won as annual benefit of total energy costs 3) SHGC and LSG more influence on cooling energy than heating energy in office buildings.

  • PDF

VMD 모듈의 열성능 특성 연구 (A Study on the Thermal Characteristics of Vacuum Membrane Distillation Module)

  • 주홍진;양용우;곽희열
    • 한국태양에너지학회 논문집
    • /
    • 제34권5호
    • /
    • pp.23-31
    • /
    • 2014
  • This study was accomplished to get the foundation design data of VMD(Vacuum Membrane Distillation) system for Solar Thermal VMD plant. VMD experiment was designed to evaluate thermal performance of VMD using PVDF(polyvinylidene fluoride) hollow fiber hydrophobic membranes. The total membrane surface area in a VMD module is $5.3m^2$. Experimental equipments to evaluate VMD system consists of various parts such as VMD module, heat exchanger, heater, storage tank, pump, flow meter, micro filter. The experimental conditions to evaluate VMD module were salt concentration, temperature, flow rate of feed sea water. Salt concentration of feed water were used by aqueous NaCl solutions of 25g/l, 35g/l and 45g/l concentration. As a result, increase in permeate flux of VMD module is due to the increasing feed water temperature and feed water flow rate. Also, decrease in permeate flux of VMD module is due to increasing salinity of feed water. VMD module required about 590 kWh/day of heating energy to produce $1m^3/day$ of fresh water.