• Title/Summary/Keyword: W-modification

Search Result 312, Processing Time 0.027 seconds

Proeutectoid ${\alpha}$ Reaction at Sub-eutectoid Temperatures in Binary Bypoeutectoid Ti-Co, Ti-Fe Alloys (2원계 아공석 Ti-Co, Ti-Fe 합금의 공석반응 온도 아래의 온도에서 초석 ${\alpha}$ 반응)

  • Lee, Hwack-Joo
    • Applied Microscopy
    • /
    • v.24 no.3
    • /
    • pp.78-86
    • /
    • 1994
  • A TEM study on proeutectoid ${\alpha}$ reaction at sub-eutectoid temperatures has been made in hypoeutectoid Ti-3.gw/o Co and Ti-5.2w/o Fe alloys. Widmanstatten ${\alpha}$ plates were formed in both alloys within the ${\beta}$ matrix with some modification of degenerate forms. These degenerate plates were formed by the sympathetic nucleation of ${\alpha}$ plates at ${\alpha}:{\beta}$ interphase boundaries. Three types of sympathetic nucleation, i.e., edge-to-edge, face-to-edge, face-to-face, were found in both alloys. The edge-to-edge sympathetically nucleated crystals formed a low-angle boundary between two crystals. The ${\alpha}:{\beta}$ interphase boundaries were found to be partially coherent interfaces which consist of regularly spaced misfit dislocations. The growth of these interphase boundaries were accomplished by the lateral movement of growth ledges. The intersection points of two ${\alpha}$ plates or the low angle boundaries which had formed by edge-to-edge sympathetic nucleation played a role as the potential sources of growth ledges during the growth of plate. The interfacial structures and the spatial morphologies of the degenerate proeutectoid ${\alpha}$ plates would be expected to influence the nucleation and growth of the succeeding eutectoid decomposition process.

  • PDF

Analysis of Thermal Shock in Tool Steels for Hot Forging (열간단조 금형강의 열충격특성연구)

  • Kim, J.W.;Kim, B.J.;Jo, I.S.;Moon, Y.H.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.14 no.3
    • /
    • pp.155-159
    • /
    • 2001
  • The thermal shock resistance has been investigated and compared in three hot-work tool steels. The resistance to thermal shock is first of all a matter of good toughness and ductility. Therefore, a proper hot-work tool steel should be characterized by high fracture strength and high temperature toughness. In this study, new test method is proposed to measure the thermal shock resistance. New method is basically based on Uddeholm' thermal shock test but some modification has been properly applied. Based on these results, some critical temperature($T_{fractures}$) at which fracture occur can be measured to characterize the thermal resistance of the materials. The specific values of ${\Delta}T$, the temperature difference between holding temperature and $T_{fractures}$, has been successfully used as a measure of the thermal shock resistance in this study, the results showed that the thermal shock method used in this study was properly modified.

  • PDF

An XY scanner with minimized coupling motions for the high speed AFM (상호 간섭이 최소화된 고속 원자현미경용 XY 스캐너 제작)

  • Park J.;Moon W.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.653-656
    • /
    • 2005
  • This paper introduces design, fabrication and experiment process of a novel scanner for the high speed AFM(Atomic Force Microscope). A proper design modification is proposed through analyses on the dynamic characteristics of the existing linear motion stages using a dynamic analysis program, Recurdyn. Since the scanning speed of each direction is allowed to be different, the linear motion stage for the high-speed scanner of AFM can be so designed to have different resonance frequencies for the modes with one dominant displacement in the desired directions. One way to achieve this objective is to use one-direction flexure mechanism for each direction and to mount one stage for fast motion on the other stage for slow motion. This unsymmetrical configuration separates the frequencies of the two vibration modes with one dominant displacement in each desired direction, hence, the coupling between the motions in the two directions. In addition, a pair of actuators is used for each axis to decrease the cross talks in the two motions and gives a force large enough to actuate the slow motion stage, which carries the fast motion stage. After these design modifications, a novel scanner with scanning speed higher than 10 Hz can be achieved to realize undistorted images in the high speed AFM.

  • PDF

The Effects of Surface Porfiles and Coatings on the Tribological Behaviors of the Surfaces of Piston Skirt (피스톤 스커트 표면의 트라이볼로지 거동에 미치는 표면형상과 코팅의 영향)

  • Cho, Dae-Hyun;Chung, Soon-Oh;Won, Young-Duck;Han, Man-Cheol;Lee, Young-Ze
    • Tribology and Lubricants
    • /
    • v.24 no.3
    • /
    • pp.122-128
    • /
    • 2008
  • To reduce the friction losses and the wear amounts in the piston assembly two methods were proposed. One is the modification of surface profile of the skirt part. The surface coating is another method to protect the sliding surfaces. To modify the profile of the skirt surfaces the surfaces were ground to have three different shapes of profiles. Also, several coatings, such as graphite, TiN, and $MoS_2$, and DLC, were used to protect the surfaces of the piston skirts. The specimens of the skirt and the cylinder bores were tested with the reciprocating wear tester. SAE 5W40 engine oil was used in boundary lubrication regime. Among several coatings the graphite and DLC coatings were very effective to reduce the friction forces. Especially, DLC film represented much better tribological performances than the others. The friction coefficient of the graphite coating was the lowest, but the graphite coating was not effective to protect the surfaces.

Study for Reduction Effect of Pool Top Radiation in Research Reactor by Using Ion Exchanger of Hot Water Layer (고온층계통의 이온교환기에 의한 연구로 수조 상부 방사선의 저감효과에 대한 연구)

  • Park, Yong-Chul;Park, Jong-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.2 no.4 s.5
    • /
    • pp.40-47
    • /
    • 1999
  • A hot water layer (HWL hereinafter) was installed at the depth of 1.2 m from the pool surface to reduce the radiation level at the pool top. After the HWL system was improved by the replacement of the filter with the Ion Exchanger to capture the Na-24, to purify the pool water of HWL and finally to reduce the radiation at the pool top. It was confirmed by the performance test of the pump and the measurement of the pressure difference through the Ion Exchanger and the strainer, that the flow characteristics of HWL system was not adversely affected after the system modification. Also the flow analysis using the pressure loss coefficients of the Ion Exchanger and strainer, calculated by the Darcy formula, could predict the flow variations by pressure changes within $10\%$ error in comparison with the field test results. It was also confirmed that HWL was maintained with the depth of 1.2 m from the pool surface because each electric water heater was electrically and thermodynamically maintained at 30 kW and the temperature of HWL was maintained with $5^{\circ}C$ higher temperature than that of pool water. Finally, it was confirmed that the pool top radiation was saturated and stabilized below 10000 nG/hr within 24 hours as the ion exchanger captured the main nucleus, Na-24 and purified the pool water of HWL.

  • PDF

ION BEAM AND ITS APPLICATIONS

  • Koh, S.K.;Choi, S.C.;Kim, K.H.;Cho, J.S.;Choi, W.K.;Yoon, Y.S.;Jung, H.J.
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.S1
    • /
    • pp.110-114
    • /
    • 1997
  • Development of metal ion source growth of high quality Cu metal film formation of non-stoichiometric $SnO_2$ films of Si(100), and modification fo polymer surface by low enregy ion beam have been carried out at KIST Ion Beam Lab. A new metal ion source with high ion beam flux has been developed by a hybrid ion beam (HIB) deposition and non-stoichiometric $SnO_2$ films are controlled by supplying energy. The ion assisted reaction (IAR) in which keV ion beam is irradiated in reactive gas environment has been deveolped for modifying the polymers and enhancing adhesion to other materials and advantages of the IAR have been reviewed.

  • PDF

Compliance Level with Therapeutic Regimen of Medication and Life Style among Patients with Hypertension in Rural Communities (일 농촌지역 고혈압 환자의 치료적 요법의 이행수준 - 약물복용과 생활습관을 중심으로 -)

  • Ahn, Yang-Heui
    • Journal of Korean Public Health Nursing
    • /
    • v.21 no.2
    • /
    • pp.125-133
    • /
    • 2007
  • Purpose: To identify the compliance level with therapeutic regimen among patients with hypertension residing in rural communities. Method: A descriptive-retrospective research design was employed. One hundred patients with hypertension using 8 Primary Health Care Posts under W Public Health Center were randomly recruited on the basis of being over 35 years of age. After obtaining written consent, the patients underwent direct interviews with a structured questionnaire carried out by 8 public health practitioners. Descriptive statistics and binary logistic regression were utilized. Results: In a binary logistic regression model adjusted for age, sex, education, income, and occupation, those who were receiving medication (OR=5.34), were undergoing a weight control program (OR=4.45), restricted alcohol (OR=9.93), or smoking cessation (OR=25.59) as recommended by medical or health professionals were more compliant (p<.05) while those under a low salt diet, exercise, and stress management were not significant statistically (p>.05). Conclusions: Further research should be conducted to validate these findings so as to facilitate the development of nursing intervention strategies for improving the compliance of hypertensive patients in respect to medication and life style modification.

  • PDF

Method of Controlling CAD Library Based on Part-shape Information Model for Bicycle Configuration Designs (자전거 편집설계를 위한 부품형상 정보 모델 기반 CAD 라이브러리 제어 방법)

  • Myung, B.S.;Lee, J.;Kim, B.C.;Mun, D.;Lee, H.;Park, S.W.
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.6
    • /
    • pp.1025-1031
    • /
    • 2013
  • A library of parametric CAD models should be provided for the reuse of design data in configuration design. Mechanical products have many options and parameters, which in turn, require a large number of CAD models for configuration designs. Existing methods for library construction are limited in their ability to decrease the number of CAD models and ensure independency between the configuration design system and the library. To solve these problems, we propose a method that controls a CAD library based on part-shape information model, and also present its technical details. To verify the proposed method, a CAD library for bicycles was constructed and design modification experiments using a prototype part-shape controller were performed. From the experiments, we found that the proposed method can effectively decrease the required number of CAD models by reusing models for configuration designs.

Running Bucket Vibration Test of Steam Turbines (증기 터빈 버킷의 회전 진동 시험)

  • 박종포;신언탁;김호종
    • Journal of KSNVE
    • /
    • v.8 no.2
    • /
    • pp.331-335
    • /
    • 1998
  • A design modification was made on the 9-th stage wheel dovetail of a high-intermediate pressure (HIP) turbine rotor for a fossil power plant that necessitates the use of new long-shank buckets for the row. A bucket vibration test is necessary to verify that the new 9-th stage buckets have adequate frequency margin from a nozzle passing frequency when running at speed. A finite element analysis (FEA) has been performed using a commercial S/W to approximately estimate bucket natural frequencies, and thus to help the vibration test. A row of the new buckets has assembled on the HIP rotor for the vibration tests using dynamic balancing facilities. The tests have been done during deceleration run with air excitation. The test results are compared with the calculation using our empirical formula, and show that the modified design meets the frequency-margin requirements.

  • PDF

Determination of Orbital Elements and Ephemerides using the Geocentric Laplace's Method

  • Espitia, Daniela;Quintero, Edwin A.;Arellano-Ramirez, Ivan D.
    • Journal of Astronomy and Space Sciences
    • /
    • v.37 no.3
    • /
    • pp.171-185
    • /
    • 2020
  • This paper presents a methodology for Initial Orbit Determination (IOD) based on a modification of the Laplace's geocentric method. The orbital elements for Near-Earth asteroids (1864) Daedalus, 2003 GW, 2019 JA8, a Hungaria-type asteroid (4690) Strasbourg, and the asteroids of the Main Belt (1738) Oosterhoff, (2717) Tellervo, (1568) Aisleen and (2235) Vittore were calculated. Input data observations from the Minor Planet Center MPC database and Astronomical Observatory of the Technological University of Pereira (OAUTP; MPC code W63) were used. These observations cover observation arcs of less than 22 days. The orbital errors, in terms of shape and orientation for the estimated orbits of the asteroids, were calculated. The shape error was less than 53 × 10-3 AU, except for the asteroid 2019 JA8. On the other hand, errors in orientation were less than 0.1 rad, except for (4690) Strasbourg. Additionally, we estimated ephemerides for all bodies for up to two months. When compared with actual ephemerides, the errors found allowed us to conclude that these bodies can be recovered in a field of vision of 95' × 72' (OAUTP field). This shows that Laplace's method, though simple, may still be useful in the IOD study, especially for observatories that initiate programs of minor bodies observation.