• 제목/요약/키워드: W-beam

검색결과 1,046건 처리시간 0.032초

Planning and Dosimetric Study of Volumetric Modulated Arc Based Hypofractionated Stereotactic Radiotherapy for Acoustic Schwannoma - 6MV Flattening Filter Free Photon Beam

  • Swamy, Shanmugam Thirumalai;Radha, Chandrasekaran Anu;Arun, Gandhi;Kathirvel, Murugesan;Subramanian, Sai
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권12호
    • /
    • pp.5019-5024
    • /
    • 2015
  • Background: The purpose of this study was to assess the dosimetric and clinical feasibility of volumetric modulated arc based hypofractionated stereotactic radiotherapy (RapidArc) treatment for large acoustic schwannoma (AS >10cc). Materials and Methods: Ten AS patients were immobilized using BrainLab mask. They were subject to multimodality imaging (magnetic resonance and computed tomography) to contour target and organs at risk (brainstem and cochlea). Volumetric modulated arc therapy (VMAT) based stereotactic plans were optimized in Eclipse (V11) treatment planning system (TPS) using progressive resolution optimizer-III and final dose calculations were performed using analytical anisotropic algorithm with 1.5 mm grid resolution. All AS presented in this study were treated with VMAT based HSRT to a total dose of 25Gy in 5 fractions (5fractions/week). VMAT plan contains 2-4 non-coplanar arcs. Treatment planning was performed to achieve at least 99% of PTV volume (D99) receives 100% of prescription dose (25Gy), while dose to OAR's were kept below the tolerance limits. Dose-volume histograms (DVH) were analyzed to assess plan quality. Treatments were delivered using upgraded 6 MV un-flattened photon beam (FFF) from Clinac-iX machine. Extensive pretreatment quality assurance measurements were carried out to report on quality of delivery. Point dosimetry was performed using three different detectors, which includes CC13 ion-chamber, Exradin A14 ion-chamber and Exradin W1 plastic scintillator detector (PSD) which have measuring volume of $0.13cm^3$, $0.009cm^3$ and $0.002cm^3$ respectively. Results: Average PTV volume of AS was 11.3cc (${\pm}4.8$), and located in eloquent areas. VMAT plans provided complete PTV coverage with average conformity index of 1.06 (${\pm}0.05$). OAR's dose were kept below tolerance limit recommend by American Association of Physicist in Medicine task group-101(brainstem $V_{0.5cc}$ < 23Gy, cochlea maximum < 25Gy and Optic pathway <25Gy). PSD resulted in superior dosimetric accuracy compared with other two detectors (p=0.021 for PSD.

광자선에 의한 민조사면 경계영역의 선량분포 (Peripheral Dose Distributions of Clinical Photon Beams)

  • 김진기;김정수;권형철
    • 한국의학물리학회지:의학물리
    • /
    • 제12권1호
    • /
    • pp.71-77
    • /
    • 2001
  • 방사선조사면의 가장자리는 반음영 영역으로 선량변화가 급격한 부분이다. 이러한 부분은 메가볼트 광자선 영역의 조사면에서 선원크기, 콜리메이터, 차폐불럭, 보조기구 그리고 내부산란선에 의한 것으로 알려져 있다. 본 연구에서는 기준조사면 경계 영역의 선량특성을 확인하고 선험적인 이론적 관계식으로 비교하여 치료시스템 조사면의 특성을 알고자 하였다. 조사면 경계영역의 주변선량분포를 깊이와 중심축으로부터 거리의 함수로서 구성하여 6MV 광자선에 의한 민조사면 경계영역의 주변선량분포를 측정하고 이를 선험적인 함수분포와 비교하였다. 3차원 물 팬톰으로 조사면 가장자리 영역의 주변선량분포를 측정하고 이를 선험적인 함수값과 비교하여 측정치와 근접한 함수방법을 알아보았다. 반도체 검출기와 전리함으로 최대선량점, 5 cm , 10 cm 깊이의 위치에서 측정값의 비를 이용하고, 유효 가장자리 영역은 80-20 % 를 선택하여 거리의 함수로 분석하였다. 깊이가 증가함에 따라경계영역의 선량폭이 증가하였다. 주변선량분포에서 검출기의 특성에 따라서 측정값과 함수값에 작은 차이가 있었다. 민조사면 경계영역 선량 분포함수를 비교하였다.

  • PDF

이온화 클러스터 빔 증착의 박막 형성 기구에 관한 연구 (A Study on the Film-Formation Mechanism by Ionized Cluster Beam Deposition)

  • 신치범;이경호;황경순;문상흡;조원일;윤경석
    • 공업화학
    • /
    • 제7권3호
    • /
    • pp.464-472
    • /
    • 1996
  • 이온화 클러스터 빔 증착에 의한 박막 형성 기구를 연구하였다. 가속전압, 기판온도, 표면이동 활성화에너지, 임계핵 크기 등이 박막의 결정입자크기 및 표면 평활도에 미치는 영향을 조사하기 위하여 Monte-Carlo방법에 근거한 전산 모사 프로그램을 개발하였다. 클러스터의 운동에너지가 박막형성에 미치는 영향을 관찰함으로써 높은 가속전압이 입자들의 표면이동에너지를 증가시키며 단결정막의 생성을 용이하게 함을 알 수 있었다. 기판온도가 증가함에 따라 입자의 운동에너지 소산(dissipation)속도는 느려지고 따라서 결정입자의 크기가 커졌다. 이러한 효과는 임계핵 크기가 클수록 두드러졌다. 표면이동 활성화에너지는 입자와 기판간의 상호작용력과 운동에너지 소산속도에 영향을 미침이 발견되었다. 가속전압, 기판온도, 표면이동 활성화에너지는 박막의 평활도에 복합적인 영향을 미치는 것을 알 수 있었다.

  • PDF

외음부 암의 방사선 치료 (Radiation Therapy in Carcinoma of the Vulva A Review of Fifteen Patients)

  • 이형식;오원용;서창옥;김귀언;박찬규
    • Radiation Oncology Journal
    • /
    • 제3권1호
    • /
    • pp.51-58
    • /
    • 1985
  • 외음부에서 발생하는 악성종양은 부인과 영역의 악성종양 중에서는 드물게 발생하는 것으로 알려져 있으며 치료에 있어서도 수술 또는 방사선치료 단독의 경우보다는 수술 후 보조적으로 방사선 치료를 시행하는 것이 더 효과적이고 치료율도 높은 것으로 알려져 있다. 이에 1971년 1월부터 1985년 4월 사이에 연세대학교 의과대학 치료방사선과에서 외음부 악성 종양으로 진단되어 방사선 치료를 받았던 15예에 대하여 후향성 분석을 시행한 바 다음과 같은 결과를 얻었기에 보고하는 바이다. 1. 15예의 외음부 종양 환자 중 4예는 수술요법 시행 후 보조적요법의 방사선 치료를 받았으며, 1예는 수술전 방사선 치료를 받았고, 나머지 10예는 근치적 목적의 방사선 치료를 받았다. 2. 방사선치료만을 시행한 군과 방사선치료 및 수술요법을 병행한 군과의 국소제어율을 비교하여 본 결과, 전 15예의 국소제어율은 $53\%(8/15)$였으며, 단지 방사선 치료만을 시행한 군에서는 $40\%$(4/10), 방사선 치료 및 수술요법을 병행한 군에서는 $80\%(4/5)$의 국소제어율을 보였다. 3. 치료 실패율은(국소적 잔존+국소재발 또는 원격전이) 단지 방사선 치료만을 시행한 군에서는 $70\%(7/10)$, 수술 후 방사선 치료를 시행한 군에서는$40\%(2/5)$의 성적을 보였으며, 치료실패 호발부위는 원발병소(외음부)였다.

  • PDF

Part I Advantages re Applications of Slab type YAG Laser PartII R&D status of All Solid-State Laser in JAPAN

  • Iehisa, Nobuaki
    • 한국레이저가공학회:학술대회논문집
    • /
    • 한국레이저가공학회 1998년도 추계학술발표대회 초록개요집
    • /
    • pp.0-0
    • /
    • 1998
  • -Part I- As market needs become more various, the production of smaller quantities of a wider variety of products becomes increasingly important. In addition, in order to meet demands for more efficient production, long-term unmanned factory operation is prevailing at a remarkable pace. Within this context, laser machines are gaining increasing popularity for use in applications such as cutting and welding metallic and ceramic materials. FANUC supplies four models of $CO_2$ laser oscillators with laser power ranging from 1.5㎾ to 6㎾ on an OEM basis to machine tool builders. However, FANUC has been requested to produce laser oscillators that allow more compact and lower-cost laser machines to be built. To meet such demands, FANUC has developed six models of Slab type YAG laser oscillators with output power ranging from 150W to 2㎾. These oscillators are designed mainly fur cutting and welding sheet metals. The oscillator has an exceptionally superior laser beam quality compared to conventional YAG laser oscillators, thus providing significantly improved machining capability. In addition, the laser beam of the oscillator can be efficiently transmitted through quartz optical fibers, enabling laser machines to be simplified and made more compact. This paper introduces the features of FANUC’s developed Slab type YAG laser oscillators and their applications. - Part II - All-solid-state lasers employing laser diodes (LD) as a source of pumping solid-state laser feature high efficiency, compactness, and high reliability. Thus, they are expected to provide a new generation of processing tools in various fields, especially in automobile and aircraft industries where great hopes are being placed on laser welding technology for steel plates and aluminum materials for which a significant growth in demand is expected. Also, in power plants, it is hoped that reliability and safety will be improved by using the laser welding technology. As in the above, the advent of high-power all-solid-state lasers may not only bring a great technological innovation to existing industry, but also create new industry. This is the background for this project, which has set its sights on the development of high-power, all-solid-state lasers with an average output of over 10㎾, an oscillation efficiency of over 20%, and a laser head volume of below 0.05㎥. FANUC Ltd. is responsible for the research and development of slab type lasers, and TOSHIBA Corp. far rod type lasers. By pumping slab type Nd: YAG crystal and by using quasi-continuous wave (QCW) type LD stacks, FANUC has already obtained an average output power of 1.7㎾, an optical conversion efficiency of 42%, and an electro-optical conversion efficiency of 16%. These conversion efficiencies are the best results the world has ever seen in the field of high-power all-solid-state lasers. TOSHIBA Corp. has also obtained an output power of 1.2㎾, an optical conversion efficiency of 30%, and an electro-optical conversion efficiency of 12%, by pumping the rod type Nd: YAG crystal by continuous wave (CW) type LD stacks. The laser power achieved by TOSHIBA Corp. is also a new world record in the field of rod type all-solid-state lasers. This report provides details of the above results and some information on future development plans.

  • PDF

유방암 방사선치료에서 Field-in-Field (FIF) 기법의 조사면 주변 선량 분석 (Evaluation of Surface Dose for Field-in-Field (FIF) Technique in Breast Radiotherapy)

  • 조일훈;김대홍
    • 한국방사선학회논문지
    • /
    • 제16권7호
    • /
    • pp.851-856
    • /
    • 2022
  • 본 연구의 목적은 종속조사면 병합 (Field-in-Field, FIF) 방식을 이용하여 유방암 방사선 치료에서 조사면 주변 표면선량 감소 효과를 확인하는 것이다. 방사선 조사를 위해 선형가속기를 사용했으며, 조사면 주변 선량은 유리 선량계로 측정하였다. SSD는 90 cm, 조사면은 10 × 10 cm2, X-선 에너지는 각각 6 MV와 10 MV를 사용했다. FIF 방식의 표면선량과 비교를 위해 금속쐐기(Physical Wedge, PW)와 동적쐐기(Dynamic Wedge, DW) 방식에서 선량을 측정하였다. PW와 DW 방식에서 각각 15°와 30°의 쐐기 각도를 사용하였다. 표면선량은 조사면 중심부에서 각각 1 cm, 3 cm, 5 cm 지점에서 측정하였다. 표면선량 분석 결과 FIF는 P W와 DW와 비교하여 치료 빔의 에너지, 쐐기 각도, 선량 측정 위치에 관계없이 모두 낮은 표면선량 값을 보였다. FIF는 유방암 치료에서 조사면 주변부 선량을 낮출 수 있으므로 표적에 균등한 선량 분포 획득뿐 만 아니라 방사선 빔에 의한 2차 장해를 감소시킬 수 있을 것으로 기대된다.

Echosounder와 GNSS 기반 해저지형측량시스템의 구축 (Construction of Sea-Floor Topographic Survey System Based on Echosounder and GNSS)

  • 이진덕;최용진;이재빈
    • 한국지리정보학회지
    • /
    • 제26권1호
    • /
    • pp.56-68
    • /
    • 2023
  • 본 연구에서는 소규모 해역을 대상으로 한 해양수심측량을 위해 단빔 음향측심기와 GNSS를 조합하여 해상에서 수평위치와 수심을 동시에 연속적으로 관측하여 해저지형정보를 추출하는 시스템을 구축하고 실측에 적용함으로써 수심측량 및 해저지형데이터 획득의 효용성을 검토하고자 하였다. 개발한 외업용 프로그램 DS-NAV와 내업용 프로그램 DS-CAD를 이용하고 대상 해역의 실측 당시 조위데이터를 적용함으로써 기준면(약최저저조면)을 기준으로 한 수심측량 성과를 도출할 수 있었으며, 또한 자동 구축된 데이터베이스로부터 해저지형을 3D 모델링하고 단면도 등을 추출할 수 있었다. 본 연구결과는 소규모 해역에서 해저지형정보를 추출하거나 해상 준설시공현장 등에 경제적으로 활용할 수 있을 것으로 기대된다.

펄스 레이저 증착기술에 의한 $Y_{3}Fe_{5)O_{12}$ 에피택셜 박막제조 (Magnetic Properties of Heteroepitaxial $Y_{3}Fe_{5)O_{12}$ Films Grown by a Pulsed Laser Ablation Technique)

  • 양충진;김상원
    • 한국자기학회지
    • /
    • 제5권2호
    • /
    • pp.128-133
    • /
    • 1995
  • YIG 단결정 소재가 주로 circulator, isolator, filter 및 resonator 등의 고주파 협대역 이동통신용 소자에 사용되고 있으나, 최근 소형/경량화에 따른 YIG 박막의 소요가 예상되면서 에피택셜 박막성장 기술이 많이 연구되고 있다. 본 연구에서 KrF excimer laser 를 사용하고, 산소분압을 20~500 mTorr로 조절하면서 박막을 제조하여 산소분압과 박막두께가 박막의 조직, 조성 및 자기특성에 미치는 영향을 조사하였다. 기판으로는 GGG(111)을 사용하였고 $700^{\circ}C$에서 증착을 실시하였다. 사용한 laser beam의 에너지 밀도는 $7.75\;J/cm_{2}$였다. 20 mTorr 산소분압 하에서 증착한 박막은 항상 에피택셜 성장을 보이고, $2.75\;{\mu}$ 두께의 시편은 $800\;^{\circ}C/20분$ 열처리 후에 $4{\pi}M_{s}$가 1500 Gauss, $H_{c}$는 3 Oe의 값을 보였고, 특히 $0.8\;\mu\textrm{m}$ 두께의 시편은 열처리 없이 $4{\pi}M_{s}$ 값이 1730 Gauss, $H_{c}$는 7 Oe의 우수한 특성을 보여, YIG 단결정의 자기특성에 육박하는 값을 보였다.

  • PDF

Nd:YAG Laser 직접 각인을 이용한 Carbon 스트레인 센서 (Carbon strain sensor using Nd: YAG laser Direct Writing)

  • 주동현;윤상우;김주한;박우태
    • 마이크로전자및패키징학회지
    • /
    • 제25권1호
    • /
    • pp.35-40
    • /
    • 2018
  • Nd:YAG Laser를 이용하여 polyimide film에 탄화(carbonization)를 진행하여 Carbon을 생성하여 저가의 센서를 간단한 제조과정으로 만들었다. 이를 통하여 유연한 저가형 압저항 센서의 특성에 관한 연구를 수행하였다. 기존에 많은 연구들이 Polyimide에 $10.6{\mu}m$의 파장을 가지는 $CO_2$ laser를 이용하여 carbonization을 하여 센서를 제작하였다. 본 논문에서는 polyimide film에 $1.064{\mu}m$의 파장을 가지는Nd:YAG laser를 이용하여 carbonization(탄화공정)을 진행하였다. 또한 Nd:YAG laser를 사용하여 polyimide film위에 직접 탄화시키며 carbon을 생성하는 최적의 전력밀도($W/cm^2$)과 속도(scan rate) 조건 조합을 찾아 해상도를 높였다. $CO_2$ laser를 사용하였던 기존의 선행연구에서는 carbon생성의 최소 선폭이 $140{\sim}220{\mu}m$의 길이를 가졌지만, 본 연구에서는 카본의 생성되는 선폭이 $35{\sim}40{\mu}m$으로 축소시켰다. 이번 연구에서 제작된 센서의 초기 면저항은 $100{\sim}300{\Omega}/{\square}$ 이였다. 곡률 반경 21 R 로 인장을 하였을 때 저항이 30% 줄어들었고, 이를 통하여 계산된 게이지 팩터는 56.6이였다. 본 연구는 압저항 센서를 제조하기 위한 단순하고, 매우 유연하고 저렴한 공정을 제공한다.

MBE로 성장된 $In_{0.5}Ga_{0.5}As/GaAs$ 양자점 원적외선 수광소자의 수소화 처리가 광학적 특성에 미치는 특이영향 (Anomalous Effect of Hydrogenation on the Optical Characterization $In_{0.5}Ga_{0.5}As$ Quantum Dot Infrared Photodetectors)

  • 임주영;송진동;최원준;조운조;이정일;양해석
    • 한국진공학회지
    • /
    • 제15권2호
    • /
    • pp.223-230
    • /
    • 2006
  • 분자선 에피택시 (MBE)법으로 성장된 양자점 원적외선 수광소자(Quantum Dot Infrared Photodetector: QDIP)구조의 $In_{0.5}Ga_{0.5}As/GaAs$ 자발형성 양자점에 대하여, 수소화 처리(Hydrogen Plasma treatment) 전후의 각각의 특성을 광학적인 방법으로 분석하였다. 광학적 특성은 광루미네센스(photoluminescence: PL) 그리고 광전류(Photocurrent: PC)방법으로 각각 15K 300K 10K 130k 범위에서 측정되었으며, 수소화 처리 전후의 $In_{0.5}Ga_{0.5}As$ 자발형성 양자점의 광학적 특성을 비교 분석해보면, 원시료(as-grown)의 하나의 봉우리가 수소화 처리를 통하여 두개의 봉우리로 나뉘지만 PL의 전체 세기(intensity)에는 큰 변화가 없었으며, 광전류는 수소화 처리 후에 감소함을 알 수 있다. 수소화 처리 전후의 샘플에 대해 PL의 결과로부터 활성화 에너지를 계산하여 비교해보면, 수소화 처리 전후의 활성화 에너지가 다름을 알 수 있고, 이 변화된 활성화 에너지 값은 측정된 광전류의 봉우리에 해당하는 에너지 값과 거의 일치함을 알 수 있다. 수소화 처리된 샘플은 역 수소화 처리를 통하여 PL 그래프의 모양이 원시료의 모양으로 되돌아가야 함에도 불구하고, 수소화 처리된 시료의 PL의 그래프와 동일한 모습을 보였다. 이러한 현상은 자발형성 양자점의 수소화 처리에 따른 양자점 내부의 양자점 조성의 변동에 그 원인이 있는 것으로 보인다.