• Title/Summary/Keyword: Volumetric model

Search Result 428, Processing Time 0.023 seconds

Volumetric Error Identification for NC Machine Tools Using the Reference Artifact (기준물을 이용한 NC 공작기계의 체적오차 규명)

  • Kim, Gyeong-Don;Jeong, Seong-Jong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.12
    • /
    • pp.2899-2908
    • /
    • 2000
  • Methodology of volumetric error identification is presented to improve the accuracy of NC machine tools by using a reference artifact and a touch trigger probe. Homogeneous transformation matrix and kinematic chain are used for modeling the geometric and thermal errors of a three-axis vertical machining center. The reference artifact is designed and fabricated to identify the model parameters by machine tool metrology. Parameters in the error model are able to be identified and updated by direct measurement of the reference artifact on the machine tool under the actual conditions which include the thermal interactions of error sources. The proposed method can speed up and simplify volumetric error identification processes.

Volumetric NURBS Representation of Multidimensional and Heterogeneous Objects: Concepts and Formation (VNURBS기반의 다차원 불균질 볼륨 객체의 표현: 개념 및 형성)

  • Park S. K.
    • Korean Journal of Computational Design and Engineering
    • /
    • v.10 no.5
    • /
    • pp.303-313
    • /
    • 2005
  • This paper proposes a generalized NURBS model, called Volumetric NURBS or VNURBS for representing volumetric objects with multiple attributes embedded in multidimensional space. This model provides a mathematical framework for modeling complex structure of heterogeneous objects and analyzing inside of objects to discover features that are directly inaccessible, for deeper understanding of complex field configurations. The defining procedure of VNURBS, which explains two directional extensions of NURBS, shows VNURBS is a generalized volume function not depending on the domain and its range dimensionality. And the recursive a1gorithm for VNURBS derivatives is described as a computational basis for efficient and robust volume modeling. In addition, the specialized versions of VNURBS demonstrate that VNURBS is applicable to various applications such as geometric modeling, volume rendering, and physical field modeling.

Rockwell Hardness Modeling Using Volumetric Variable (체적변수를 이용한 로크웰 경도 모델링)

  • Chin, Do-Hun;Oh, Sang-Rok;Yoon, Moon-Chul
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.3
    • /
    • pp.394-401
    • /
    • 2013
  • A new Rockwell hardness (HRC) model using a volumetric parameter by a least square and fractal interpolation method is suggested. The results are also investigated in comparison to real measured hardness data. For this purpose, the measurement of an indented volume is performed using a confocal laser scanning microscope (CLSM), and the captured height encoded image (HEI) is used as an original surface for the calculation of the indented volume. After configuring the surface, the constructed volume is calculated and used as an independent variable for HRC hardness modeling. The hardness model is established using an experimental modeling technique involving a least square algorithm and fractal interpolating model, and this suggested model can be used to reliably predict the Rockwell hardness. These techniques can also be applied to the modeling of the Brinnell and Vickers hardnesses using a volumetric variable.

Analysis of 3D Volumetric Error for Machine Tool using Ball Bar (볼바를 이용한 공작기계의 3차원 공간오차 해석)

  • Lee, Ho-Young;Choi, Hyun-Jin;Son, Jae-Hwan;Lee, Dal-Sik
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.5
    • /
    • pp.1-6
    • /
    • 2011
  • Machine tool errors have to be characterized and predicted to improve machine tool accuracy. Therefore, it is very important to assess errors in machine tools. Volumetric error analysis has been developed by many researchers. This paper presents a useful technique for analyzing the volumetric errors in machine tools using the ball bar. The volumetric error model is proposed in specific vertical machining center and the program is developed for generating NC code, acquiring the ball bar data, and analyzing the volumetric errors. The developed system assesses the volumetric errors such as positional, straightness, squareness, and back lash. Also this system analyzes the dynamic performance such as servo gain mismatch. The radial data acquired by ball bar on 3D space is used for analyzing these errors. It is convenient to test the volumetric errors on 3D space because all errors are calculated at once. The developed system has been tested using an actual vertical machining center.

A micro-computed tomographic study using a novel test model to assess the filling ability and volumetric changes of bioceramic root repair materials

  • Fernanda Ferrari Esteves Torres;Jader Camilo Pinto;Gabriella Oliveira Figueira;Juliane Maria Guerreiro-Tanomaru;Mario Tanomaru-Filho
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.1
    • /
    • pp.2.1-2.8
    • /
    • 2021
  • Objectives: New premixed bioceramic root repair materials require moisture for setting. Using micro-computed tomography (micro-CT), this study evaluated the filling ability and volumetric changes of calcium silicate-based repair materials (mineral trioxide aggregate repair high-plasticity [MTA HP] and Bio-C Repair, Angelus), in comparison with a zinc oxide and eugenol-based material (intermediate restorative material [IRM]; Dentsply DeTrey). Materials and Methods: Gypsum models with cavities 3 mm deep and 1 mm in diameter were manufactured and scanned using micro-CT (SkyScan 1272. Bruker). The cavities were filled with the cements and scanned again to evaluate their filling capacity. Another scan was performed after immersing the samples in distilled water for 7 days to assess the volumetric changes of the cements. The statistical significance of differences in the data was evaluated using analysis of variance and the Tukey test with a 5% significance level. Results: Bio-C Repair had a greater filling ability than MTA HP (p < 0.05). IRM was similar to Bio-C and MTA HP (p > 0.05). MTA HP presented the largest volumetric change (p < 0.05), showing more volume loss than Bio-C and IRM, which were similar (p > 0.05). Conclusions: Bio-C Repair is a new endodontic material with excellent filling capacity and low volumetric change. The gypsum model proposed for evaluating filling ability and volumetric changes by micro-CT had appropriate and reproducible results. This model may enhance the physicochemical evaluation of premixed bioceramic materials, which need moisture for setting.

Stabilized 3D Pose Estimation of 3D Volumetric Sequence Using 360° Multi-view Projection (360° 다시점 투영을 이용한 3D 볼류메트릭 시퀀스의 안정적인 3차원 자세 추정)

  • Lee, Sol;Seo, Young-ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.76-77
    • /
    • 2022
  • In this paper, we propose a method to stabilize the 3D pose estimation result of a 3D volumetric data sequence by matching the pose estimation results from multi-view. Draw a circle centered on the volumetric model and project the model from the viewpoint at regular intervals. After performing Openpose 2D pose estimation on the projected 2D image, the 2D joint is matched to localize the 3D joint position. The tremor of 3D joints sequence according to the angular spacing was quantified and expressed in graphs, and the minimum conditions for stable results are suggested.

  • PDF

3D Volumetric Capture-based Dynamic Face Production for Hyper-Realistic Metahuman (극사실적 메타휴먼을 위한 3D 볼류메트릭 캡쳐 기반의 동적 페이스 제작)

  • Oh, Moon-Seok;Han, Gyu-Hoon;Seo, Young-Ho
    • Journal of Broadcast Engineering
    • /
    • v.27 no.5
    • /
    • pp.751-761
    • /
    • 2022
  • With the development of digital graphics technology, the metaverse has become a significant trend in the content market. The demand for technology that generates high-quality 3D (dimension) models is rapidly increasing. Accordingly, various technical attempts are being made to create high-quality 3D virtual humans represented by digital humans. 3D volumetric capture is spotlighted as a technology that can create a 3D manikin faster and more precisely than the existing 3D model creation method. In this study, we try to analyze 3D high-precision facial production technology based on practical cases of the difficulties in content production and technologies applied in volumetric 3D and 4D model creation. Based on the actual model implementation case through 3D volumetric capture, we considered techniques for 3D virtual human face production and producted a new metahuman using a graphics pipeline for an efficient human facial generation.

Error Analysis and Compensation for the Volumetric Errors of a Vertical Machining Center Using Hemispherical Helix Ball Bar Test (반구상의 나선형 볼바측정을 통한 수직형 머시닝 센터의 오차 해석 및 보정)

  • Yang, Seung-Han;Kim, Ki-Hoon;Park, YongKuk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.9
    • /
    • pp.34-40
    • /
    • 2002
  • Machining accuracy is affected by quasi-static errors of machining center. Since machine errors have a direct influence upon both the surface finish and geometric shape of the finished workpiece, it is very important to measure the machine errors and to compensate these errors. The laser measurement method for identifying geometric errors of machine tool has the disadvantages such as high cost, long calibration time and usage of volumetric error synthesis model. Accordingly, this paper deals with analysis of the geometric errors of a machine tool using ball bar test without using complicated error synthesis model. Statistical analysis method was adopted in this paper for deriving geometric errors using hemispherical helix ball bar test. As a result of experiment, geometric errors of the vertical machining center are compensated by 88%.

Kinetic Study of Coal/Biomass Blended Char-CO2 Gasification Reaction at Various temperature (다양한 온도에서 석탄/바이오매스의 혼합 촤-CO2 가스화 반응특성 연구)

  • Kim, Jung Su;Kim, Sang Kyum;Cho, Jong Hoon;Lee, Si Hoon;Rhee, Young Woo
    • Korean Chemical Engineering Research
    • /
    • v.53 no.6
    • /
    • pp.746-754
    • /
    • 2015
  • In this study, we investigated the effects of the temperature on the coal/biomass $char-CO_2$ gasification reaction under isothermal conditions of $700{\sim}900^{\circ}C$ using the lignite(Indonesia Eco coal) with biomass (korea cypress). Ni catalysts were impregnated on the coal by the ion-exchange method. Four kinetic models which are shrinking core model (SCM), volumetric reaction model (VRM), random pore model (RPM) and modified volumetric reaction model (MVRM) for gas-solid reaction were applied to the experimental data against the measured kinetic data. The Activation energy of Ni-coal/biomass, non-catalyst coal/biomass $Char-CO_2$ gasification was calculated from the Arrhenius equation.

Low-rank Coal Char Gasification Research with Mixed Catalysts at Fixed Reactor (고정층 반응기에서의 저등급 석탄 혼합촉매가스화 반응특성)

  • An, Seung Ho;Park, Ji Yun;Jin, Gyoung Tae;Rhee, Young Woo
    • Korean Chemical Engineering Research
    • /
    • v.55 no.1
    • /
    • pp.99-106
    • /
    • 2017
  • In this study, mixed catalytic char gasification of Indonesia low-rank coal Kideco was investigated under nitrogen atmosphere and isothermal conditions at a fixed reactor. The effects of the temperature were investigated at various temperature (700, 750, 800, $850^{\circ}C$). The effects of blend ratio of catalysts ($K_2CO_3$, Ni) were investigated with different blend ratios (1:9, 3:7, 5:5, 7:3 and 9:1). The sample was prepared by mixing with $K_2CO_3$ physically and by ionexchange method with Ni. The data from thermogravimetric analyzer and gas chromatography were applied to four gassolid reaction kinetic models including shrinking core model, volumetric reaction model, random pore model and modified volumetric reaction model.