• Title/Summary/Keyword: Volumetric Rate

Search Result 470, Processing Time 0.029 seconds

체적비와 오프셋 변화에 의한 소음기내의 유동특성과 압력손실에 관한 연구 (A Study on the Flow Characteristics and Pressure Loss of a Muffler for the Variation of Volumetric Rate and Offset)

  • 김민호;정우인;천인범
    • 한국자동차공학회논문집
    • /
    • 제8권4호
    • /
    • pp.93-99
    • /
    • 2000
  • It is well known that an automotive muffle strongly influences engine efficiency and noise reduction. The performance of a muffler system is determined by the geometrical parameters such as the relative location of an inlet and outlet pipe size and cross sectional geometry of a chamber. In this study numerical analysis was performed to examine the flow characteristics in the simple automotive muffler for the variation of volumetric rate and offset. The computational grid generation was carried out. The RNG k-$\varepsilon$ turbulence model was applied. To provide the boundary condition for numerical analysis the experimental measurement wes carried out. As a result of this study we could understand that there was a recirculation flow inside muffler and pressure loss depends on the variation of volumetric rate and offset.

  • PDF

힘센서를 이용한 기상 연료의 과도적 분사율 계측에 관한 연구 (A Study on Transient Injection Rate Measurement of Gas Fuels Using Force Sensor)

  • 이재현;배규한;기영민;문석수
    • 한국분무공학회지
    • /
    • 제27권4호
    • /
    • pp.181-187
    • /
    • 2022
  • For carbon neutrality, direct-injection hydrogen engines are attracting attention as a future power source. It is essential to estimate the transient injection rate of hydrogen for the optimization of hydrogen injection in direct injection engines. However, conventional injection rate measurement techniques for liquid fuels based on the injection-induced fuel pressure change in a test section are difficult to be applied to gaseous fuels due to the compressibility of the gas and the sealing issue of the components. In this study, a momentum flux measurement technique is introduced to obtain the transient injection rate of gaseous fuels using a force sensor. The injection rate calculation models associated with the momentum flux measurement technique are presented first. Then, the volumetric injection rates are estimated based on the momentum flux data and the calculation models and compared with those measured by a volumetric flow rate meter. The results showed that the momentum flux measurement can detect the injection start and end timings and the transient and steady regimes of the fuel injection. However, the estimated volumetric injection rates showed a large difference from the measured injection rates. An alternative method is suggested that corrects the estimated injection rate results based on the measured mean volumetric flow rates.

혐기성 생물막법에 의한 유기성 배수의 처리 (Treatment of Organic Wastewater by the Anaerobic Fixed-Film Process)

  • 김용대;정경훈
    • 한국환경보건학회지
    • /
    • 제17권2호
    • /
    • pp.41-47
    • /
    • 1991
  • A study on the effects of volumetric loading rate, surface loading rate and hydraulic. retention time (HRT) for the anaerobic treatment was conducted with the anaerobic fixed-film process using synthetic wastewater at lower temperature than that of conventional anaerobic treatment. The results are as follows 1. Alkalinity and pH value decreased as the hydraulic retention time increased 2. Increase of the volumetric lodaing rate led to increasl of effluent COD concentration and decrease of COD removal efficiency. 3. The removed volumetric loading rate increased linearly according to the increase of the volumrtric loading rate. 4. Similarly, the linear increase of the removed surface loading rate was noticed with an increase of the surface loading rate.

  • PDF

터빈 유량계를 사용한 이상유동의 측정

  • 심재우
    • 한국해양공학회지
    • /
    • 제12권2호통권28호
    • /
    • pp.147-152
    • /
    • 1998
  • In this study turbine flowmeters were used to predict volumetric flow rate of each phase in two-phase, gas-liquid, flowing in a vertical tube. To determine volumetric flow rates of two-phase, air-water, flowing vertically upward through the polycarbonate tube(57mm ID-inside diameter), two turbine flow meters were used. For void fraction measurements, two gamma densitometers were used at each location of the turbine flow meter, one at the upstream and the other at the downstream. It was determined that the turbine flowmeter's outputs were a function of actual volumetric flow rate of each of the two phases. A two-phase flow model was developed.

  • PDF

Phenol함유 폐수의 처리에서 분말 활성탄 첨가의 영향 (Effects of Fine Powder Active Carbon Addition on the Wastewater Treatment Containing Phenol)

  • 강선태;김정목
    • 한국환경보건학회지
    • /
    • 제22권3호
    • /
    • pp.98-102
    • /
    • 1996
  • This study investigated performance of the phenol degradation and reaction characteristics according to variation of phenol volumetric loading rates and dilution rates in suspension and PACT reactors using Pseudomonas sp. B3. 1. Removal efficiencies of the PAC unit indicated about 100 % with phenol volumetric loading rates from 0.4 phenol $kg/ma^3\cdot d$ to 1.2 phenol $kg/m^3\cdot d$, however, which of the suspension reactor showed about 100% with from 0.2 phenol $kg/m^3\cdot d$ to 0.75 phenol $kg/ma^3\cdot day$. 2. The cell density slightly was decreased from 298.2 mg/l to 272 mg/l, when dilution rate for suspension was reactor increased from 0.4 to 1.41 1/d, and also the cell density suddenly was decreased to 145.5 mg/l and was washed out at the dilution rate higher than 1.60 1/d. But the cell density for the PAC unit was linearly decreased with dilution rate of from 0.8 to 3.0 1/d, and showed 220.75 mg/l at maximum dilution rate. 3. The phenol utilization rate was increased from 0.008 to 0.031 phenol g/l$\cdot$h, when dilution rate for suspension reactor was increased from 0.4 to 1.5 1/d, however, the rate for the PAC unit was linearly increased from 0.017 to 0.061 phenol g/l$\cdot$h as variation changes from 0.017 to 0.061 phenol g/l$\cdot$h dilution rate.

  • PDF

무산소-RBC 공정을 이용한 질소제거 특성 및 동력학적 인자 도출 (Characteristics and Biological Kinetics of Nitrogen Removal in Wastewater using Anoxic-RBC Process)

  • 최명섭;손인식
    • 한국환경과학회지
    • /
    • 제12권10호
    • /
    • pp.1085-1093
    • /
    • 2003
  • This study was conducted to investigate anoxic-RBC (rotating biological contactor) and its application in advanced municipal wastewater treatment process to remove biologically organics and ammonia nitrogen. Effluent COD and nitrogen concentration increased as the increase of volumetric loading rate. But, the concentration changes of NO$_2$$\^$-/ -N and NO$_3$$\^$-/ -N were little, as compared to COD and NH$_4$$\^$+/ -N. When the volumetric loading rate increased, COD removal efficiency and nitrification appeared very high as 96.7∼98.8% and 92.5∼98.8%, respectively. However, denitrification rate decreased to 76.2∼88.0%. These results showed that the change of volumetric loading rate affected to the denitrification rate more than COD removal efficiency or nitrification rate. The surface loading rates applied to RBC were 0.13~6.0lg COD/㎡-day and 0.312∼1.677g NH$_4$$\^$+/-N㎡-day and they were increased as the increase of volumetric loading rate. However, the nitrification rate showed higher than 90%. The thickness of the biofilm in RBC was 0.130 ∼0.141mm and the density of biofilm was 79.62∼83.78mg/㎤. They were increased as surface loading rate increased. From batch kinetic tests, the k$\_$maxH/ and k$\_$maxN/ were obtained as 1.586 g C/g VSS-day, and 0.276 g N/g VSS-day, respectively. Kinetic constants of denitrifer in anoxic reactor, Y, k$\_$e/, K$\_$s/, and k were 0.678 mg VSS/mg N, 0.0032 day$\^$-1/, 29.0 mg N/l , and 0.108 day$\^$-l/, respectively. P and K$\_$s/, values of nitrification and organics removal in RBC were 0.556 g N/㎡-day and 18.71 g COD/㎡-day, respectively.

Pichia stipitis 세포의 재순환 생물반응기를 이용한 Xylose로부터 Ethanol 생산 (Ethanol Production from Xylose by Pichia stipitis Using Cell-recycled Bilreactor)

  • 박영민;정인식;크리스론식;이윤형
    • KSBB Journal
    • /
    • 제4권2호
    • /
    • pp.74-77
    • /
    • 1989
  • Volumetric productivity를 향상시키기 위하여 미생물 재순환에 의한 연속 시스템을 이용하였다. 연속발효조의 연구에서 9.2g/1와 15.0,g/1의 범위의 세포 농도를 유지할 수 있었다. 4%의 xylose의 feed와 1.04g $O{_2}$hr-g DCW의 specific oxygen supply rate의 조건에서 희석율이 0.0349 h$^{-1}$ethanol 수율은 0.36이었다. Ethanol volumetric productivity는 같은 희석율에서 0.244g/hr-$\ell$로 증가하였으며 이것은 회분배양값의 260%이었다.

  • PDF

공기부상 생물막 반응기를 이용한 산업폐수 처리 (Wastewater Treatment using Air-lift Biofilm Reactor)

  • 최광수;한기백
    • 한국환경과학회지
    • /
    • 제9권4호
    • /
    • pp.351-367
    • /
    • 2000
  • Air-lift biofilm reactor should be an admirable process substituting conventional activated sludge process, because of its small area requirement as well as high volumetric loading capacity and stability against loading and chemical shocks. However most of the past research on the performance of ABR was focused on the sewage treatment. This research studied the applicability of ABR to treat high strength wastewater. A bench-scale ABR was operated to treat high strength synthetic wastewater, tannery wastewater and petrochemical wastewater, and its applicability was conclusive In case of synthetic wastewater, ABR showed good performance in which the substarate removal efficiency was higher that 80% even under short HRT(1.4 hr) and high volumetric loading rate(9.3 kgCODcr/$m^3$.day). When ABR was applied to treat tannery wastewater, it was suggested that the maximum volumetric loading rate and F/M ratio should be 7.7kgCODcr/$m^3$.day, 0.76 $day^{-1}$, respectively. And high substrate removal efficiency over than 90 % was observed with 4,000 mgCODcr/L of petrochemical wastewater. Even though effluent concentration was quite high, ABR should be applicable to treat the high strength wastewater, because of its high loading capacity.

  • PDF

체적효율을 고려한 가변밸브 개폐시기의 조정에 의한 실린더내 잔류가스량에 관한 연구 (A Study on the Residual Gas Fraction in Cylinder by the Adjustment of Variable Valve Timing with Volumetric Efficiency)

  • 남정길
    • 한국자동차공학회논문집
    • /
    • 제9권5호
    • /
    • pp.82-88
    • /
    • 2001
  • The EGR is needed fur one of various strategies to reduce NOx emission. But to get the proper EGR rate, the intake and exhaust system become complicated. That is a reason why we consider using the internal EGR system. The internal EGR is a system which reduces NOx by controling the residual gas fraction in cylinder by changing valve timing and valve lift of intake and exhaust. In this paper, characteristics of volumetric efficiency and residual gas fraction in cylinder were investigated for various engine speeds by changing valve timing and valve lift of intake and exhaust in the 4 stroke-cycle diesel engine. Volumetric efficiency and residual gas fraction were calculated by the method of characteristics. As the results, residual gas fraction and volumetric efficiency in cylinder by variable valve timing were visualized.

  • PDF

고정화 공생 Bacteria를 이용한 호발폐수 중 PVA분해 신공정 개발 (Development of a New Process for PVA Degradation in Desize Wastewater by lmmobilized Symbiotic Bacteria)

  • 김정목;조무환조윤래정선용
    • KSBB Journal
    • /
    • 제6권4호
    • /
    • pp.395-402
    • /
    • 1991
  • A new process was developed to degrade PVA(polyvinyl alcohol) in desize wastewater. Two symbiotic bacteria of Pseudomonas strain G5Y and PW were immobilized on the media by adsorption. A natural zeolite was chosen as the best media considering cell adhesion capacity, sedimentation rate, and material cost. PVA and COD removal efficiencies of this system for synthetic wastewater were 84% and 85% at the retention time of 6 hr, when the volumetric loading rate was PVA 8g/L·day and COD 8g/L·day, and cell density was 19,775 mg/L. In case of desire wastewater, they were 78% and 72% at the retention time of 6 hr, respectively, when the volumetric loading rate was PVA 8g/L·day and COD 13.2g/L·day, and cell density was 32,899mg/L. In case of desize wastewater, PVA and COD removal efficiencies were lower than synthetic wastewater, but cell density of the desize wastewater was lower than that of the synthetic wastewater, because there were insufficiency of necessary nutrition and variety of desize materials in the desize wastewater. A pilot test was successfully performed showing 88% and 82%, PVA and COD removal efficiencies at the retention time of 24 hr, when volumetric loading rate were 4.7 PVA g/L·day and COD 6.9g/L·day, and cell density was 12,,324 mg/L.

  • PDF