• Title/Summary/Keyword: Volume quantification

Search Result 139, Processing Time 0.027 seconds

Stochastic buckling quantification of porous functionally graded cylindrical shells

  • Trinh, Minh-Chien;Kim, Seung-Eock
    • Steel and Composite Structures
    • /
    • v.44 no.5
    • /
    • pp.651-676
    • /
    • 2022
  • Most of the experimental, theoretical, and numerical studies on the stability of functionally graded composites are deterministic, while there are full of complex interactions of variables with an inherently probabilistic nature, this paper presents a non-intrusive framework to investigate the stochastic nonlinear buckling behaviors of porous functionally graded cylindrical shells exposed to inevitable source-uncertainties. Euler-Lagrange equations are theoretically derived based on the three variable refined shear deformation theory. Closed-form solutions for the shell buckling loads are achieved by solving the deterministic eigenvalue problems. The analytical results are verified with numerical results obtained from finite element analyses that are conducted in the commercial software ABAQUS. The non-intrusive framework is completed by integrating the Monte Carlo simulation with the verified closed-form solutions. The convergence studies are performed to determine the effective pseudorandom draws of the simulation. The accuracy and efficiency of the framework are verified with statistical results that are obtained from the first and second-order perturbation techniques. Eleven cases of individual and compound uncertainties are investigated. Sensitivity analyses are conducted to figure out the five cases that have profound perturbative effects on the shell buckling loads. Complete probability distributions of the first three critical buckling loads are completely presented for each profound uncertainty case. The effects of the shell thickness, volume fraction index, and stochasticity degree on the shell buckling load under compound uncertainties are studied. There is a high probability that the shell has non-unique buckling modes in stochastic environments, which should be known for reliable analysis and design of engineering structures.

Characterizing Organelles in Live Stem Cells Using Label-Free Optical Diffraction Tomography

  • Kim, Youngkyu;Kim, Tae-Keun;Shin, Yeonhee;Tak, Eunyoung;Song, Gi-Won;Oh, Yeon-Mok;Kim, Jun Ki;Pack, Chan-Gi
    • Molecules and Cells
    • /
    • v.44 no.11
    • /
    • pp.851-860
    • /
    • 2021
  • Label-free optical diffraction tomography (ODT), an imaging technology that does not require fluorescent labeling or other pre-processing, can overcome the limitations of conventional cell imaging technologies, such as fluorescence and electron microscopy. In this study, we used ODT to characterize the cellular organelles of three different stem cells-namely, human liver derived stem cell, human umbilical cord matrix derived mesenchymal stem cell, and human induced pluripotent stem cell-based on their refractive index and volume of organelles. The physical property of each stem cell was compared with that of fibroblast. Based on our findings, the characteristic physical properties of specific stem cells can be quantitatively distinguished based on their refractive index and volume of cellular organelles. Altogether, the method employed herein could aid in the distinction of living stem cells from normal cells without the use of fluorescence or specific biomarkers.

Quantification of the 25 Components in Onkyung-Tang by Ultra Performance Liquid Chromatography-Electrospray Ionization-Tandem Mass Spectrometry (UPLC-ESI-MS/MS를 이용한 온경탕 중 25종 성분의 함량분석)

  • Seo, Chang-Seob;Shin, Hyeun-Kyoo
    • Korean Journal of Pharmacognosy
    • /
    • v.47 no.1
    • /
    • pp.92-101
    • /
    • 2016
  • In this study, an ultra-performance liquid chromatography-electrospray ionization-mass spectrometry (UPLC-ESI-MS/MS) method was established for simultaneous determination of the 25 marker components, including chlorogenic acid, gallic acid, oxypaeoniflorin, homogentisic acid, methyl gallate, caffeic acid, 3,4-dihydroxybenzaldehyde, paeoniflorin, albiflorin, liquiritin, nodakenin, ferulic acid, ginsenoside Rg1, liquiritigenin, coumarin, cinnamic acid, benzoylpaeoniflorin, ginsenoside Rb1, cinnamaldehyde, paeonol, glycyrrhizin, 6-gingerol, evodiamine, rutecarpine, and spicatoside A in traditional Korean formula, Onkyung-tang. All analytes were separated on a Waters Acquity UPLC BEH $C_{18}$ analytical column ($2.1{\times}100mm$, $1.7{\mu}m$) at $45^{\circ}C$ using a mobile phase of 0.1% (v/v) formic acid in water and acetonitrile with gradient elution. The MS analysis was carried out using a Waters ACQUITY TQD LC-MS/MS coupled with an electrospray ionization (ESI) source in the positive and negative modes. The flow rate and injection volume were 0.3 mL/min and $2.0{\mu}L$, respectively. The correlation coefficient of all analytes in the test ranges was greater than 0.98. The limits of detection and quantification values of the 25 marker compounds were in the ranges 0.03-19.43 and 0.09-58.29 ng/mL, respectively. As a result, methyl gallate, 3,4-dihydroxybenzaldehyde, evodiamine, and rutecarpine were not detected in this sample and the concentrations of the 21 compounds except for the above 4 compounds were $33.09-3,496.32{\mu}g/g$ in Onkyung-tang decoction. Among these compounds, paeonol was detected at the highest amount as a $3,496.32{\mu}g/g$.

Rapid High Performance Liquid Chromatographic Quantification of Major Isoflavones in Soybeans and Soybean Pastes

  • Kim, Won-Chan;Kwon, Soon-Ho;Rhee, In-Koo;Hur, Jong-Moon;Jeong, Hyun-Hee;Choi, Sun-Ha;Lee, Kyung-Bok;Kang, Young-Hwa;Song, Kyung-Sik
    • Food Science and Biotechnology
    • /
    • v.15 no.1
    • /
    • pp.24-27
    • /
    • 2006
  • A simple HPLC quantification method was developed for genistein, genistin, daidzein, and daidzin in soybeans and soybean products. The procedure used a $4.6{\times}100\;mm$ $Chromolith^{(R)}$ RP-18e column with a mobile phase of 1% HOAc in 20% MeOH to 1% HOAc in 80% MeOH for 10 min. The injection volume was $2\;{\mu}L$ at a flow rate of 2 mL/min. Detection was carried out under UV at 254 nm. Under these conditions, the major isoflavones daidzein, daidzin, genistein, and genistin in soybean and soybean pastes were eluted within 7 min with baseline separation. Optimal extraction of the above four major isoflavones was achieved when 40 g of soybean or soybean paste was refluxed in 100 mL of 95% ethanol for 2 hr. Ten different soybean cultivars and nine commercial soybean pastes were analyzed by this method. The total isoflavone content was highest in the cultivar Somyung ($2,497\;{\mu}g/g$ dry weight). The isoflavone content in soybean pastes varied widely from manufacturer to manufacturer (an almost five-fold difference between the highest and lowest values). Such variations were presumably due to differences in fermentation conditions, type of soybeans used, and levels of such additives as starch and salt.

Residue analysis of spinetoram and spinosad on paprika leaf using the modified QuEChERS pre-treatment methods

  • Kim, Young-Shin;Yang, Jun-Young;Jin, Na-Young;Yu, Yong-Man;Youn, Young-Nam;Lim, Chi-Hwan
    • Korean Journal of Agricultural Science
    • /
    • v.44 no.4
    • /
    • pp.487-494
    • /
    • 2017
  • Spinosad and spinetoram are widely used insecticides for the control of lepidopteran larvae, leaf miners, and thrips; however, they might also have low toxicity toward beneficial insects like bees. Because these pesticides are easily photolyzed by ultraviolet radiation, the QuEChERS method, with its simple pretreatment procedure, is often used for analyzing residues of spinosad and spinetoram. The present study performed a residue analysis using a modified QuEChERS method by pretreating with ammonium salt. The limit of detection (LOD) of the modified method was 0.05 mg/kg and the limit of quantification (LOQ) was 0.25 mg/kg. The coefficient of determination ($R^2$) for the calibration curve was 0.999. Also, we examined any change in the adhesion of spinosad and spinetoram on the plants depending on a spray volume. The adhesion was approximately 70% when the spray volume was increased from 60 L to 120 L per 10 a whereas the adhesion was approximately 37% when the spray volume was increased from 125 L to 250 L. This showed that the amount of adhesion decreased with the higher spray volume. The efficacy result of spinetoram was that over 90% of Frankliniella occidentalis was controlled with the application volume of 125 L per 10 a. Therefore, the result of this study indicates that control of insects is effective and sufficient with a spray volume of 125 L per 10 a in paprika cultivation facilities.

Inter- and Intra-Observer Variability of the Volume of Cervical Ossification of the Posterior Longitudinal Ligament Using Medical Image Processing Software

  • Shin, Dong Ah;Ji, Gyu Yeul;Oh, Chang Hyun;Kim, Keung Nyun;Yoon, Do Heum;Shin, Hyunchul
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.4
    • /
    • pp.441-447
    • /
    • 2017
  • Objective : Computed tomography (CT)-based method of three dimensional (3D) analysis ($MIMICS^{(R)}$, Materialise, Leuven, Belgium) is reported as very useful software for evaluation of OPLL, but its reliability and reproducibility are obscure. This study was conducted to evaluate the accuracy of $MIMICS^{(R)}$ system, and inter- and intra-observer reliability in the measurement of OPLL. Methods : Three neurosurgeons independently analyzed the randomly selected 10 OPLL cases with medical image processing software ($MIMICS^{(R)}$) which create 3D model with Digital Imaging and Communication in Medicine (DICOM) data from CT images after brief explanation was given to examiners before the image construction steps. To assess the reliability of inter- and intra-examiner intraclass correlation coefficient (ICC), 3 examiners measured 4 parameters (volume, length, width, and length) in 10 cases 2 times with 1-week interval. Results : The inter-examiner ICCs among 3 examiners were 0.996 (95% confidence interval [CI], 0.987-0.999) for volume measurement, 0.973 (95% CI, 0.907-0.978) for thickness, 0.969 (95% CI, 0.895-0.993) for width, and 0.995 (95% CI, 0.983-0.999) for length. The intra-examiner ICCs were 0.994 (range, 0.991-0.996) for volume, 0.996 (range, 0.944-0.998) for length, 0.930 (range, 0.873-0.947) for width, and 0.987 (range, 0.985-0.995) for length. Conclusion : The medical image processing software ($MIMICS^{(R)}$) provided detailed quantification OPLL volume with minimal error of inter- and intra-observer reliability in the measurement of OPLL.

Measurement of the left ventricular regurgitation by gated cardiac blood pool scan: Before and after valvular replacement surgery (대동맥 및 승모판 판막폐쇄부전증에서 방사성동위원소 심혈관촬영술을 이용한 혈역류량 측정에 관한 연구)

  • Shin, Seong-Hae;Chung, June-Key;Lee, Myung-Chul;Cho, Bo-Youn;Seo, Jung-Don;Lee, Young-Woo;Koh, Chang-Soon;Suh, Kyung-Phill;Lee, Yung-Kyoon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.16 no.2
    • /
    • pp.29-36
    • /
    • 1982
  • Quantification of the regurgitation amount is important before and after valvular replacement surgery. Until now cardiac catheterization with cineventriculography, echocardiography have been used to measure the regurgitation amount, but also have many limitations. EKG gated cardiac blood pool scan provides a simple, non-invasive -method for quantify the regurgitation amount. By calculating the ratio of left ventricular to right ventricular stroke counts (stroke volume ratio) in gated bood pool scan, we measured the left ventricular regurgitation amount in 28 cases of valvular regurgitation and 25 cases of normal group. 1. Stroke volume ratio was higher in cases of valvular regurgitation $(2.11{\pm}0.58)$ than in cases of normal control $(1.15{\pm}0.31)$. (p<0.01). 2. Stroke volume ratio was classified by regurgitation grade using X-ray cineventriculography. In grades of mild regurgitation $(Grade\;I{\sim}II)$, stroke volume ratio was $2.02{\pm}0.29$, and in grades of severe regurgitation $(Grade\;III{\sim}IV)$, stroke volume ratio was $2.55{\pm}0.34$, so stroke volume ratio was well correlated with the grade of X-ray cineventriculography. 3. Stroke volume ratio was classfied by functional class made in New York Heart Association. In classes of mild regurgitation $(class\;I{\sim}II)$, stroke volume ratio was $2.08{\pm}0.26$, and in classes of severe regurgitation $(class\;III{\sim}IV)$, stroke volume ratio was $2.55{\pm}0.38$, Stroke volume ratio well represented the functional class. 4. After aortic and mitral valve replacement in 28 patients, the stroke volume ratio, decreased from $2.11{\pm}0.58\;to\;1.06{\pm}0.26$. Gated blood pool scan provides a noninvasive method of qnantifying valvular regurgitation and assessing the result of surgical interventions.

  • PDF

A Study on Characteristics of On-Street Parking on Local Streets (국지도로의 노상주차 특성에 관한 연구)

  • Kim, Ki-Hyuk;Lee, Sang-Inn
    • Journal of Korean Society of Transportation
    • /
    • v.22 no.7 s.78
    • /
    • pp.33-40
    • /
    • 2004
  • This study aims to provide guidelines for the selection of on-street parking spot on local streets considering conditions of surrounding area and characteristics of traffic generation. This guideline provides the method which determine required roadway width for planning and design of local streets. It is necessary to identify factors for the location selection analysis. This research team selects 12 case study areas to investigate traffic environment on the sites for this analysis. Most of factors which influence on-street parking are found to have a qualitative data format except traffic volume and pedestrian movement data. Quantification theory II which is known to be suitable for qualitative analysis has been applied to identify the meaningful variables for dependent variable. In addition, discriminant analysis has performed to verify the correlation for each variable with hit ratio. Road width, traffic volume, street traders and their heavy packages, and illegally parked vehicle are found to be most significant factors for selection of on-street parking location. Therefore, it is necessary to consider traffic volume generated from massive residential complex and traffic volume for outside and above-mentioned factors for installation of on-street parking facility in the case of new road construction or road width widen.

Quantification of Oxygen Transfer in Test Tubes by Integrated Optical Sensing

  • Wittmann, Christoph;Schutz, Verena;John, Gernot;Heinzle, Elmar
    • Journal of Microbiology and Biotechnology
    • /
    • v.14 no.5
    • /
    • pp.991-995
    • /
    • 2004
  • Immobilized sensor spots were applied for online measurement of dissolved $O_2$, in test tubes. Oxygen transport was quantified at varied shaking frequency and filling volumes. The k$_{L}$ a increased with increasing shaking frequency and decreasing filling volume. In non-baffled tubes the maximum $k_{L}a$ value was $70h^{-1}$, equivalent to a maximum $O_2$ transfer capacity of 15mMh^{-1}$. Monitoring of the hydrodynamic profile revealed that the liquid bulk rotated inside the tube with an inclined liquid surface, whereby the angle between the surface and tube wall increased with increasing shaking frequency. The $k_{L}a$ clearly correlated to the surface area. Placement of four baffles into the tubes improved the oxygen transfer up to 3-fold. The highest increase in $k_{L}a$ was observed at high filling volume and high shaking frequency. The maximum $k_{L}a$ in baffled tubes was $100 h^{-1}$.

Automated Segmentation of the Lateral Ventricle Based on Graph Cuts Algorithm and Morphological Operations

  • Park, Seongbeom;Yoon, Uicheul
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.2
    • /
    • pp.82-88
    • /
    • 2017
  • Enlargement of the lateral ventricles have been identified as a surrogate marker of neurological disorders. Quantitative measure of the lateral ventricle from MRI would enable earlier and more accurate clinical diagnosis in monitoring disease progression. Even though it requires an automated or semi-automated segmentation method for objective quantification, it is difficult to define lateral ventricles due to insufficient contrast and brightness of structural imaging. In this study, we proposed a fully automated lateral ventricle segmentation method based on a graph cuts algorithm combined with atlas-based segmentation and connected component labeling. Initially, initial seeds for graph cuts were defined by atlas-based segmentation (ATS). They were adjusted by partial volume images in order to provide accurate a priori information on graph cuts. A graph cuts algorithm is to finds a global minimum of energy with minimum cut/maximum flow algorithm function on graph. In addition, connected component labeling used to remove false ventricle regions. The proposed method was validated with the well-known tools using the dice similarity index, recall and precision values. The proposed method was significantly higher dice similarity index ($0.860{\pm}0.036$, p < 0.001) and recall ($0.833{\pm}0.037$, p < 0.001) compared with other tools. Therefore, the proposed method yielded a robust and reliable segmentation result.