• 제목/요약/키워드: Volume of distribution

검색결과 2,633건 처리시간 0.034초

마이크로채널에서 과냉 핵비등 시발점의 비정상 수치해석 (TRANSIENT SIMULATION OF SUBCOOLED ONSET OF NUCLEATE BOILING IN A MICRO-CHANNEL)

  • 이희준
    • 한국전산유체공학회지
    • /
    • 제16권2호
    • /
    • pp.88-93
    • /
    • 2011
  • A numerical study of subcooled onset of nucleate boiling (ONB) in a micro-channel under pulsed heating using volume of fluids (VOF) model was conducted. The VOF simulation adopting the existing experimental condition is compared to the experimental data. The time to ONB was determined when the void fraction at the microheater surface first appeared. The theoretical superheat for homogeneous nucleation relatively predicts the transient ONB results of convective flow of water well based on local temperature distribution. It was found that once heat load increases at the heater, transient flow boiling starts to occur faster.

Analysis of Fluid-thermal Coupling in Ferrofluid Bearing Used in High Speed Machines

  • Yin, Xin;Ma, Jien;Fang, Youtong;Jin, Shuai
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권4호
    • /
    • pp.421-428
    • /
    • 2013
  • This paper describes analysis of journal bearings lubricated with ferrofluid, which are very suitable for high speed machines. Comparing to conventional lubricants, the coupling of hydrodynamic, thermal and magnetic properties of ferrofluid adds to the complexity in analysis. Modified Reynolds equation and energy equation are derived and solved numerically using finite volume method. Pressure distribution is got which takes temperature effect into consideration. Static characteristics are then discussed. One optimal scheme is also got according to analysis results.

피지옴 모델을 이용한 심실의 전기활성시간 분포에 따른 심박출 성능평가 (Estimation of Cardiac Pumping Performance according to the Ventricular Electrical Activation Time Distribution by Using Physiome Model)

  • 김형균;임기무
    • 대한의용생체공학회:의공학회지
    • /
    • 제36권5호
    • /
    • pp.198-203
    • /
    • 2015
  • The purpose of the study is to examine the effects of pacemaker location on cardiac pumping efficacy theoretically. We used a three-dimensional finite element cardiac electromechanical model of canine ventricles with models of the circulatory system. Electrical activation time for normal sinus rhythm and artificial pacing in apex, left ventricular free wall, and right ventricular free wall were obtained from electrophysiological model. We applied the electrical activation time maps to the mechanical contraction model and obtained cardiac mechanical responses such as myocardial contractile ATP consumption, stroke work, stroke volume, ejection fraction, and etc. Among three artificial pacing methods, left ventricle pacing showed best performance in ventricular pumping efficacy.

아산지역 도로변의 $NO_2$ 및 TSP 농도에 관한 연구 (A study on $NO_2$ and TSP levels of the Major Trunk Road in Asan-area)

  • 손부순;김현탁;차정훈
    • 환경위생공학
    • /
    • 제14권2호
    • /
    • pp.68-74
    • /
    • 1999
  • The atmospheric concentrations of Nitrogen Dioxide ($NO_2$) and Total Suspended Particulates (TSP) at the traffic road side were measured n Asan area, Choongchumg-namdo during May 1998 and January, 1999.The results of the study are as follows;1. The aversge value of airbone $NO_2$ and TSP levels were 28.5ppb and 5.9mg/me in Asan area. 2. The concentration distribution of NO2 and TSP is high for the season of winter. On a daily pattern, somewhat high value is appeared in the afternoon. 3. For the station, terminal, and Shinchang, the average value of $NO_2$ is 33.6ppb, 27.9ppb and 24.1ppb in sequence, and the ones of TSP is 6.3mg/m3, 6.0mg/m3 and 5.3mg/m3 in order.4. The high levels of $NO_2$ and TSP were positively related to traffic volume.

  • PDF

Vibration and stability of embedded cylindrical shell conveying fluid mixed by nanoparticles subjected to harmonic temperature distribution

  • Shokravi, Maryam;Jalili, Nader
    • Wind and Structures
    • /
    • 제25권4호
    • /
    • pp.381-395
    • /
    • 2017
  • Nonlinear vibration and instability of cylindrical shell conveying fluid-nanoparticles mixture flow are studied in this article. The surrounding elastic medium is modeled by Pasternak foundation. Mixture rule is used for obtaining the effective viscosity and density of the fluid-nanoparticles mixture flow. The material properties of the elastic medium and cylindrical shell are assumed temperature-dependent. Employing first order shear deformation theory (FSDT), the motion equations are derived using energy method and Hamilton's principal. Differential quadrature method (DQM) is used for obtaining the frequency and critical fluid velocity. The effects of different parameters such as volume percent of nanoparticles, boundary conditions, geometrical parameters of cylindrical shell, temperature change, elastic foundation and fluid velocity are shown on the frequency and critical fluid velocity of the structure. Results show that with increasing volume percent of nanoparticles in the fluid, the frequency and critical fluid velocity will be increases.

A Feasibility Study on In-Vessel Core Debris Cooling through Lower Cavity Flooding

  • Yang, Soo-Hyung;Baek, Won-Pil;Chang, Soon-Heung
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 추계학술발표회논문집(1)
    • /
    • pp.309-314
    • /
    • 1996
  • Feasibility study has been accomplished to evaluate the effectiveness of the in-vessel core debris cooling through lower cavity flooding using two dimensional finite difference scheme. The volume of cerium pool and decay power rate generated in corium pool were evaluated as important parameters to the temperature distribution on the reactor vessel lower head through previous works. In this study, the corium volume based on the System 80+ core structure and time dependent decay power rate are considered for feasibility evaluation. In addition, preliminary plans for the in-vessel core debris cooling through lower cavity flooding as severe accident management strategy, i.e. flooding timing, method and capacity, are suggested based on the result of the numerical study, international tendency related to in-vessel core debris cooling through lower cavity flooding.

  • PDF

수치모델을 이용한 ICP-CVD 장치의 증착 균일도 해석 (Numerical Modeling of Deposition Uniformity in ICP-CVD System)

  • 주정훈
    • 한국표면공학회지
    • /
    • 제41권6호
    • /
    • pp.279-286
    • /
    • 2008
  • Numerical analysis is done to investigate which would be the most influencing process parameter in determining the uniformity of deposition thickness in TiN ICP-CVD(inductively coupled plasma chemical vapor deposition). Two configurations of ICP antenna are modeled; side and top planar. Side and top gas inlets are considered with each ICP antenna geometries. Precursor for TiN deposition was TDMAT(Tetrakis Diethyl Methyl Amido Titanium). Two step volume dissociation of TDMAT is used and absorption, desorption and deposition surface reactions are included. Most influencing factors are H and N concentration dissociated by electron impact collisions in plasma volume which depends on the relative positions of gas inlet and ICP antenna generated hot plasma region. Low surface recombination of N shows hollow type concentration, but H gives a bell type distribution. Film thickness at substrate edges is sensitive to gas flow rate and at high pressures getting more dependent on flow characteristics.

경사기능재료 사각평판의 정적 및 진동해석 (Statics and Free Vibration Characteristics of Rectangular Plates Made of Functionally Graded Materials)

  • 민준식;송오섭;이윤규;정남희;강호식
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.439-445
    • /
    • 2003
  • In the recent years, functionally graded materials(FGM) have gained considerable attention in the high temperature environment applications. In the present work, study of the deflection and vibration of a functionally graded rectangular plate made of Ti-6Al-4V and Al$_2$O$_3$ is presented. Material properties are graded in the thickness direction of the plate according to volume fraction power law distribution Effects of volume fractions(power law exponent) on the deflection and natural frequency of FGM plate is studied. Also effects of temperature is studied. Wavier Solution is used to analyzed the FGM plate.

  • PDF

Investigation of Microstructure Inhomogeneity in SiCp-reinforced Aluminum Matrix Composites

  • Gacsi, Zoltan;Gur, C.Hakan;Makszimus, Andrea;Pieczonka, Tadeusz
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part2
    • /
    • pp.1303-1304
    • /
    • 2006
  • The type, volume fraction, size, shape and arrangement of embedded particles influence the mechanical properties of the particle reinforced metal matrix composites. This presents the investigation of the SiC particle and porosity distributions in various aluminum matrix composites produced by cold- and hot-pressing. The microstructures were characterized by optical microscopy and stereological parameters. SiC and porosity volume fractions, and the anisotropy distribution function were measured to establish the influence of the consolidation method.

  • PDF

$TiO_2$를 함유한 규산염 유리의 상분리를 이용한 다공질 유리의 제조 (Preparation of Porous Glasses by the Phase-separation of the Silicate Glass Containing $TiO_2$)

  • 김병훈;최석진;박태철
    • 한국세라믹학회지
    • /
    • 제28권1호
    • /
    • pp.29-36
    • /
    • 1991
  • Microporous glasses in the system TiO2-SiO2-Al2O3-B2O3-CaO-Na2O were prepared by the phase-separation technique. Morphology and distribution of pore and specific surface area of glasses heated and leached out at various conditions were investigated by SEM and Porosimeter. Crystallization of glasses heated above transition temperature was also inspected by X-ray diffraction method. When the heating temperature and time increased, the pore size and volume increased, but the specific surface area decreased above the critical temperature. The phase-separation, specific surface area and pore size showed more sensitive change on the variation of heating temperature than of heating time. The specific surface area and micropore volume of porous glasses prepared in this study were about 120-330$m^2$/g and 0.001-0.01cc/g, respectively. Mean pore size of porous glasses were about 20-90$\AA$. Anatase phases was deposited when the parent glass was heat-treated at 75$0^{\circ}C$ for 6hrs.

  • PDF