• Title/Summary/Keyword: Volume Duration

Search Result 472, Processing Time 0.029 seconds

A Study on Development of High Efficiency Toilets with VOF Numerical Analysis (VOF 수치해석을 통한 고절수형 위생도기 개발에 관한 연구)

  • An, Il Yong;Lee, Young Lim;Jo, Woo Suck;Kim, Jin Ho
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.6
    • /
    • pp.946-953
    • /
    • 2012
  • When water shortage has been getting worse recently, toilet water-saving is one of the most effective way to solve the water shortage. Therefore, in this study, toilet flushing performance was investigated with VOF(Volume Of Fluid) model to obtain the basic design data for the development of high-efficiency toilets. The result showed that the shorter trapway, the longer the flushing duration time. However, the shorter trapway is found to have disadvantage in exhausting dirt due to relatively weak siphon and higher curvature. Since the remaining water in a trapway appears to help siphon, it is also an important factor in developing high-efficiency toilets. Although higher water level in the water tank shows better performance in flushing, lower water level is preferred to save water. Too low water level may cause dirt to clog the trapway due to relatively weak siphon.

MIXING CONDITIONS WITH SPRAY-JET INTERACTION FOR EFFECTIVE SOOT REDUCTION IN DIESEL COMBUSTION

  • Chikahisa, Takemi;Hishinuma, Yukio;Ushida, Hirohisa
    • International Journal of Automotive Technology
    • /
    • v.3 no.1
    • /
    • pp.17-26
    • /
    • 2002
  • The authors have reported significant reductions in particulate emissions of diesel engines by generating strong turbulence during the combustion process. This study aims to identify optimum conditions of turbulent mixing for effective soot reduction during combustion. The experiments were conducted with a constant volume combustion vessel equipped with abet-generating cell, in which a small amount of fuel is injected during the combustion of the main spray. The jet of burned gas from the cell impinges the main flame, causing changes In the mixing of fuel and air. Observation was made for a variety combinations of distances between spray nozzle and Jet orifice at different directions of impingement. It Is shown that compared with the case without Jet flame soot decreases when the jet impinges. When the jet is very close to the flame, it penetrates the soot cloud and causes little mixing. There were no apparent differences in the combustion duration when the direction of impingement was varied, although the mechanisms of soot reduction seemed different. An analysis of local turbulent flews with PIV (Particle image Velocimetry) showed the relationship between the scale of the turbulence and the size of the soot cloud.

Study of the Migration Rate of L-menthol into Cigarette Pack and Delivery Rate to Cigarette Smoke (포갑 내에서 L-menthol의 이동과 연중 이행 효과에 관한 연구)

  • 김병구;김시몽;양범호;제병권;이규서
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.24 no.1
    • /
    • pp.46-52
    • /
    • 2002
  • This study was carried out to investigate the transfer rate of I-menthol constituent into cigarette case and delivery rate to cigarette smoke. Test sample was used a light-type standard brand cigarette made in Korea. I-Menthol contents was measured according to A.O.A.C(1990) method by G.C and smoking conditions was a puff volume of 35$m\ell$ and 2.0s duration, taken once per minute to filter tipping paper plus 3mmwith 20 cigarettes. Migration rate of menthol into cigarette case had an interrelation with triacetin contents into filter and 6% triacetin level was most suitable. I-Menthol transferred to filter part from tobacco sheet by 20.2% in one month after cigarette manufacture, and the transfer was continued subsequently. Maximum menthol transfer in five months was 4.1% to foils and other packing materials and the loss outside of cigarette pack was also 3.9% below. The migration balance of menthol into cigarette pack and the delivery to cigarette smoke were the optimum condition when menthol was added at the ration of 30% in filter to 70% in the other parts into cigarette.

Effect of Austempering Time on the Microstructure and Mechanical Properties of Ultra-High Strength Nanostructured Bainitic Steels (오스템퍼링 시간에 따른 초고강도 나노 베이나이트강의 미세조직과 기계적 특성)

  • Lee, Ji-Min;Hwang, Byoungchul
    • Korean Journal of Materials Research
    • /
    • v.30 no.2
    • /
    • pp.87-92
    • /
    • 2020
  • This study deals with the effects of austempering time on the microstructure and mechanical properties of ultra-high strength nanostructured bainitic steels with high carbon and silicon contents. The steels are composed of bainite, martensite and retained austenite by austempering and quenching. As the duration of austempering increases, the thickness of bainitic ferrite increases, but the thickness of retained austenite decreases. Some retained austenites with lower stability are more easily transformed to martensite during tensile testing, which has a detrimental effect on the elongation due to the brittleness of transformed martensite. With increasing austempering time, the hardness decreased and then remained stable because the transformation to nanostructured bainite compensates for the decrease in the volume fraction of martensite. Charpy impact test results indicated that increasing austempering time improved the impact toughness because the formation of brittle martensite was prevented by the decreased fraction and increased stability of retained austenite.

Drought Index Calculation for Irrigation Reservoirs (관개용 저수지의 한발지수산정)

  • 김선주;이광야;신동원
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.37 no.6
    • /
    • pp.103-111
    • /
    • 1995
  • Drought index calculation based on the principal hydrological parameters, such as rainfall and reservoir storage, can estimate the duration and intensity of drought in irrigation reservoirs. It is difficult to build up a drought criteria since the conditions change variously by the reliability of rainfall. Because of the increasing water demands, it is urgent to prepare a generalized positive countermeasure to overcome drought. Water demands can at calculated but the estimation of drought characteristics, and the effective water management method can be established. The purpose of this study is to obtain a drought index and build up a data-base on the reservoir basins for establishing the fundamental hydrological data-base. This Index can observe the behavior of the WSI(Water Supply Index) and the component indices. The results summarized through this study are as follows. 1. WSI value of zero does not correspond to 100% in average due to the skewness in the probability distributions. 2. WSI is not a linear index; that is, given change in terms of water volume or percentage of average does not result in a proportional change on the WSI scale. 3. WSI is not always between the reservoir and the rainfall index in magnitude. This is only true if the component indices are of opposite sign. If they are of the same sign, the SWSI will often have a mangitude greater than either of the component indices. This is easily understood, because the concurrence of extreme values of the same sign for the two components is rarer than the occurrence of extreme values for either of the two components individually.

  • PDF

Effect of Fludioxonil, Flutolanil, and Thifluzamide on Suppression of Damping-off Caused by Rhizoctonia solani on Panax ginseng (인삼 잘록병(Rhizoctonia solani) 발생억제에 미치는 Fludioxonil, Flutolanil 및 Thifluzamide의 효과)

  • Cho, Dae-Hui;Yu, Yun-Hyun
    • Journal of Ginseng Research
    • /
    • v.29 no.4
    • /
    • pp.185-191
    • /
    • 2005
  • In vitro and in vivo effectiveness of fungicides were evaluated for the control of damping off caused by Rhizoctonia solani on Panax ginseng. Fludioxonil(67 mg a. i./L), flutolanil(75 mg a. i./L), thifluzamide(35 mg a. i./L), and mepronil (750 mg a. i./L) were selected from 9 fungicides, which were based on inhibition of mycelial growth of R. solani (isolate Rh 9801) and duration of fungicidal effectiveness against the pathogen in vitro. Field trials were made twice in the year of 2003 and 2004. Experimental plots $(54m{\times}0.9m)$ of 4-year-old ginseng fields were artificially infested with 5kg and 14 kg in fresh weight of inoculum in 2003 and 2004, respectively. The fungicides were drenched at a volume of 8l in $3.6m{\times}0.9m$ with 3 replications. Fludioxonil, flutolanil, thifluzamide and mepronil reduced the incidence of damping off by $73\%,\;69\%,\;69\%\;and\;43\%$, respectively. In the 2004 trial, fludioxonil, flutolanil, and thifluzamide showed similar result as reducing the incidence by $85\%,\;84\%,\;and\;82\%$, respectively, in the plot where the inoculum was applied 2.8 times more than the 2003. The disease incidences in untreated control were $12\%$ in 2003 and $47\%$ in 2004.

A Study on the Determination of Ionic and Molecular Weight of Dissolved Substance by Dialysis Method (Ⅳ). Effects of Specific Surface Area and Pore Size of Dialysis Membrane on Dialysis (透析法에 依한 이온量 및 分子量의 決定에 關한 硏究 (第4報). 比表面積 및 透析膜孔이 透析에 미치는 影響)

  • Yun Kyoung Shin;Jhun Rhee;Taechun Kim
    • Journal of the Korean Chemical Society
    • /
    • v.21 no.1
    • /
    • pp.44-52
    • /
    • 1977
  • The effects of specific surface area and pore size of dialysis membrane on the dialysis were studied. It was confirmed that the intermittent sampling method(in which any volume of dialyzing solution is sampled intermittently at every moment after any duration of the dialysis experiment) is suitable for the determination of a dialysis coefficient. It was also confirmed that the diffusion coefficient of a electrolyte through membrane is smaller than the free diffusion coefficient though the pore size of dialysis membrane is extremely large.

  • PDF

Characteristics of high-efficiency rust removal by adjusting variable frequency and voltage charging using the Pulsed Power system (펄스파워를 이용한 전압 및 주파수 가변에 의한 고효율 RUST (녹) 제거 특성에 대한 연구)

  • Song, Woo-Jung;Kim, Su-Weon;Jeon, Jin-An;Joung, Jong-Han;Kim, Hwi-Young;Kim, Hee-Je
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.180-183
    • /
    • 2002
  • The pulsed power system was widely making use good of many industrial and environments. The pulse generator generally required for short pulse duration and high peak value was forced to consider its volume and economy. In this paper, this system is designed and fabricated which has a compact size of pulse generator with switched MOSFET. We have studied the removal of rust material using Arc discharging. It have tested their characteristics by adjusting variable voltage charging and pulse repetition rate. As a result, We can eliminate rust materials with this device.

  • PDF

Study on Pultrusion of FRP by Dielectric Heating (유전가열에 의한 FRP의 인발성형 연구)

  • Park, Hoy-Yul;Kang, Dong-Pil;Ahn, Myeong-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.445-448
    • /
    • 2004
  • Radio frequency and microwave dielectric heating are well-known electroheating methods, used in industrial applications where non electrically conducting materials are to be heated, dried or otherwise processed. The major reason for considering this technique for any process is based on its unique ability to transfer heat into the volume of an electrically non conducting material such as insulator directly, rather than, via a surface. Conventional heating must first bring heat to the product surface and there after it depends on the physical characteristics and condition of the material as to how effectively this heat is transmitted into the mass. The product would suffer surface damage before the main body is adequately processed. Dielectric heating is applied to enhance conventional heating methods and to drastically shorten the required processing duration. Although the use of dielectric heating has been a well proven technique for several years in some industries, its application in the preheating of FRP has been limited by the insufficient experience. In this paper a method is described for uniform radio frequency heating of preheating of FRP.

  • PDF

A Study on Backwashing of Granular Fiters Used in Water Treatment (정수처리를 위한 여과지의 역세척에 관한 연구)

  • Lee, Jung Taek;Ahn, Jong Ho;Choi, Keun Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.3
    • /
    • pp.61-72
    • /
    • 1999
  • To obtain the experimental data for design and operation of actual filtration processes, a sand filter and three kinds of dual media filters in pilot-plant scale were operated in this study. We analyzed the effect of filter medium composition on the filter performance and the effects of backwash water flow rates, length of stream line and air flow rate on the filter backwash efficiency. We also compared the efficiencies of the combined air-water backwashing and the water backwashing in dual media filters. As the backwash water flow rates or the length of stream line increased, the final turbidity of backwash water was decreased and the filtration duration time after backwash was increased. In the case of the combined air-water backwashing, the backwash water quantity needed for backwashing the dual media filters could be decreased. The total volume of filtered water for the dual media filters during filter run was over three times larger than that for the sand filter. The dual media filters could be operated at a high filtration rate of 360 m/day.

  • PDF