• Title/Summary/Keyword: Volume Calibration

Search Result 252, Processing Time 0.023 seconds

A Study on the Development of CCTV Camera Autonomous Posture Calibration Algorithm for Simultaneous Operation of Traffic Information Collection and Monitoring (교통정보 수집 및 감시 동시운영을 위한 CCTV 카메라 자율자세 보정 알고리즘 개발에 관한 연구)

  • Jun Kyu Kim;Jun Ho Jung;Hag Yong Han;Chi Hyun SHIN
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.22 no.1
    • /
    • pp.115-125
    • /
    • 2023
  • This paper relates to the development of CCTV camera posture calibration algorithm that can simultaneously collect traffic information such as traffic volume and speed in the state of view of the CCTV camera set for traffic monitoring. The developed autonomous posture calibration algorithm uses vehicle recognition and tracking techniques to identify the road, and automatically determines the angle of view for the operator's traffic surveillance and traffic information collection. To verify the performance of the proposed algorithm, a CCTV installed on site was used, and the results of the angle of view automatically calculated by the autonomous posture calibration algorithm for the angle of view set for traffic surveillance and traffic information collection were compared.

Development of the calibration procedure of the reference sound source and case study on the uncertainty evaluation (기준음원의 교정 절차 개발 및 불확도 평가 사례)

  • Jae-Gap Suh;Wan-Ho Cho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.3
    • /
    • pp.344-350
    • /
    • 2024
  • A Reference Sound Source (RSS) is an important standard device employed in measuring sound power. The specifications of RSS is specified in international standards, and it is classified as a major calibration item in the field of acoustic metrology. Since the output power of RSS is affected by the supply voltage, each country needs to secure its own calibration service system. In this study, a procedure for calibrating a RSS is established based on the reverberant room conditions and uncertainty evaluation is conducted. Basically, the calibration procedure can apply a precision measurement process of acoustic power, and here, the measurement method using the reverberation chamber of ISO 3741 is applied. For this purpose, a measurement system is constructed, measurements are conducted with two types of RSS, and measurement uncertainty is evaluated. Through measurement examples, it is confirmed that the non-uniformity of the sound pressure distribution in the reverberation room and the volume measurement uncertainty contributed significantly to the overall uncertainty. Additionally, the influence of input voltage is experimentally examined to examine the uncertainty contribution that can be reflected in acoustic power measurements.

Estimation of Body Weight Using Body Volume Determined from Three-Dimensional Images for Korean Cattle (한우의 3차원 영상에서 결정된 몸통 체적을 이용한 체중 추정)

  • Jang, Dong Hwa;Kim, Chulsoo;Kim, Yong Hyeon
    • Journal of Bio-Environment Control
    • /
    • v.30 no.4
    • /
    • pp.393-400
    • /
    • 2021
  • Body weight of livestock is a crucial indicator for assessing feed requirements and nutritional status. This study was performed to estimate the body weight of Korean cattle (Hanwoo) using body volume determined from three-dimensional (3-D) image. A TOF camera with a resolution of 640×480 pixels, a frame rate of 44 fps and a field of view of 47°(H)×37°(V) was used to capture the 3-D images for Hanwoo. A grid image of the body was obtained through preprocessing such as separating the body from background and removing outliers from the obtained 3-D image. The body volume was determined by numerical integration using depth information to individual grid. The coefficient of determination for a linear regression model of body weight and body volume for calibration dataset was 0.8725. On the other hand, the coefficient of determination was 0.9083 in a multiple regression model for estimating body weight, in which the age of Hanwoo was added to the body volume as an explanatory variable. Mean absolute percentage error and root mean square error in the multiple regression model to estimate the body weight for validation dataset were 8.2% and 24.5kg, respectively. The performance of the regression model for weight estimation was improved and the effort required for estimating body weight could be reduced as the body volume of Hanwoo was used. From these results obtained, it was concluded that the body volume determined from 3-D of Hanwoo could be used as an effective variable for estimating body weight.

A Study on the Waste Volume Calculation for Efficient Volume Monitoring in a Landfill Facility (매립장의 효율적인 체적 모니터링을 위한 체적 계산 방법에 대한 연구)

  • Lee, Young Dae;Cho, Sung Youn
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.5
    • /
    • pp.153-159
    • /
    • 2012
  • For the enhancement of civilization of a city, the standard landfill facility is needed for the efficient, and computerized management. In this paper, we proposed the waste volume calculation method using the point cloud of the surface of three dimensional object based on stereo camera measurement. This computes the quantity of waste volume for continuos monitoring. It helps not only to predict the evaluation factor of the usable age of a landfill. facility. Furthermore, it can be used for the basis of general algorithm of three dimensional object.

Measurements of Soot Volume Fraction Using Laser Induced Incandescence (레이저 유도 백열법을 이용한 화염 내부 매연 농도 측정)

  • Lee, Seung;Lee, Sang-Hup;Lee, Byeong-Jun;Hahn, Jae-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.5
    • /
    • pp.725-732
    • /
    • 2000
  • Laser induced incandescence (LII) method is frequently used to measure soot volume fraction in flames. In this study, experiments were performed to measure soot volume fraction in coaxial diffusion flame using LII method and calibrated with laser scattering/extinction method. The effects of laser intensity (>$1{\times}10^8W/cm^2$), laser wavelength (532nm, 1064nm) and detection wavelength (400nm, 600nm) on the LII signal were investigated. On the range of $4{\times}10^8{\sim}8{\times}10^8W/cm^2$ there were no effects of laser intensity on LII signal. Except these ranges, LII signal was increased with laser intensity. For the long gate width, the LII signals of the higher laser intensity (>${\vartheta}(GW/cm^2)$) cases had better correlation with soot volume fraction which were measured by laser extinction method compared with lower laser intensity cases. The errors of 2-dimensional cases at the calibration height were approximately 50% regardless of laser wavelength.

Application of SDAHL-74 Watershed Model to a Long Term Runoff Analysis in the Mountainous Watershed (산지유역에 대한 USDAHL-74 유역수문모형의 장기유출 해석적용)

  • 권순국;고덕구
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.29 no.2
    • /
    • pp.53-63
    • /
    • 1987
  • Due to their wide range of application, deterministic comprehensive hydrologic models using digital computers have been developed in all countries of the world and researches are being undertaken for their appropriate applications. The aim of this study has been to demonstrate the practical implementation of a physically based distributed hydrologic model, the USDAHL-74 model and to investigate its ability to simulate the long term estimate of water balance quantities in a Korean mountainous watershed. Application of the model to Dochuk watershed indicates the following results. 1.Since the USDAHL-74 model includes all the major components of the hydrologic cycle in agricultural watersheds, thus is comprehnsive, the model seems to have a wide range of application from the fact that simulation results obtained are not only runoff volumes m various time units but their spatial variation as well as even soil moisture within the watershed. 2.An approximate calibration to determine the parameter values in the model using various data obtained from D0chuk shed shows that the simulation error of yearly runoff volume is only 0.6 % and a correlation coefficient between observed daily runoff volume and simulated one is 0.91 in all calibrated period.3.As a verification test of the model, runoff volumes are simulated using 1986 year data without changing the parameter values determined by 1985 year data. The tests show that the USDAHL-74 model is a flexible tool and that realistic production to simulate the long term estimate of runoff in Korean mountainous watershed could be obtained using only a short period of calibration.4. Despite of the encouraging results, there still remain minor problems concerning the practical application of the model to improve the result of simulations. Some of these are the small descrepancies between observed and simulated daily runoff volume appeared in the vicinity of peaks and the recession of1 the daily hydrographs and the model performance for the frozen ground and melting process in the model. 5. Alough the use of parameter with physical significance and the ability to improve calibrations on the basis of physical reasoning represents advantages in the simulation for ungaged watersheds, further researches are needed to use the USDAHL-74 mode to simulate runoff in ungaged watersheds.

  • PDF

A Study on the Uncertainty Estimation of Flowmeter Calibrator with Two Master Flowmeters (2개의 기준유량계를 이용한 유량계 교정장치의 측정불확도 평가에 관한 연구)

  • Choi Jong Oh;Lee Woan Kyu;Lim Ki Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.10
    • /
    • pp.1219-1230
    • /
    • 2004
  • Comparing to the gravimetric and volumetric method, the flowmeter calibration based on the master meter method is relatively economical and convenient, especially for high flowrate. The uncertainty of flow quantity and flowrate using the master meter method was evaluated according to the GUM (Guide to the Expression of Uncertainty in Measurement). In order to apply for the wider flow range, two master meters (electromagnetic flow meter) were employed as reference flowmeters. The uncertainty of the master meter was obtained by combining the statistical variation of the repeated measurements and the variation of fluid density and pipe material due to temperature and pressure changes were scrutinized. for a practical application, the uncertainty of calibrator, whose measuring capacity of 1000 ㎥/h obtained by employing two 500 ㎥/h electromagnetic How meters, was evaluated. The uncertainty budget shows the quantitative contribution of each uncertainty component to the overall uncertainty of the calibrator. As a result, it was found that the dominant uncertainties were from the master meter, which was evaluated statistically, and from the process of least squares fitting. On the contrary, the uncertainties arising from the variation of the fluid density and the pipe volume due to the temperature and pressure were negligible.

Correction of Secondary ion Mass Spectrometry depth profile distorted by oxygen flooding (Oxygen flooding에 의해 왜곡된 SIMS depth profile의 보정)

  • 이영진;정칠성;윤명노;이순영
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.2
    • /
    • pp.225-233
    • /
    • 2001
  • Distortion of Secondary Ion Mass Spectrometry(SIMS) depth profile, which is usually observed when the analysis is made using oxygen flooding on the surface of Si with oxide on it, has been corrected. The origin of distortion has been attributed to depth calibration error due to sputter rate difference and concentration calibration error due to relative sensitivity factor(RSF) difference between $SiO_2$ and Si layers, In order to correct depth calibration error, artifact in analysis of sodium ion on oxide was used to define the interface in SIMS depth profile and oxide thickness was measured with SEM and XPS. The differences of sputter rate and RSF between two layers have been attributed to volume swelling of Si substrate occurred by oxygen flooding induced oxidation. The corrected SIMS depth profiles showed almost the same results with those obtained without oxygen flooding.

  • PDF

Calibration Methods for the Gas Chromatographic Analysis of ppt-level Hydrogen Sulfide (H2) in Air (환경 대기 중 ppt 수준의 황화수소 분석을 위한 GC 방식의 검량 기법에 대한 연구)

  • 김기현;오상인;최여진;최규훈;주도원
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.6
    • /
    • pp.679-687
    • /
    • 2003
  • In this study, we investigated the analytical techniques to quantify the ambient concentration of hydrogen sulfide (H$_2$S) in air at ppt concentration level. For this purpose, an on-line GC analytical system equipped with both pulsed-flame photometric detector (PFPD) and thermal desorption unit (TDU) was investigated by collecting ambient air samples. The results of our study generally indicated that calibration conditions of GC system is highly sensitive to affect the accuracy of the analytical technique. Most importantly. we found that the use of different matrices in the the preparation stage of working standards was sensitive to control the overall performance of this technique. The calibration of our analytical system was tested by the two types of working standard (prepared by mixing either with high purity $N_2$ or with the ambient air). According to this test, the latter represented more efficiently the detecting conditions of actual air samples. The peak occurrence patterns of both air samples and standards (prepared by mixing with ambient air) were altered in a similar manner as the function of the loaded volume; however, it was not the case for the $N_2$-mixed standards. Results of our study suggest that detection of H$_2$S is highly different from other sulfides and that its quantification requires minimiaing interfering effects of non -pure substance (like water vapor) and (either sorptive or destructive) loss effects.

Quantitative Measurements of Soot Particles in a Laminar Diffusion Flame Using a LII/LIS Technique (LII/LIS 기법을 이용한 층류확산화염 매연입자의 정량화)

  • Chung, J.W.;Lee, W.;Han, Y.T.;Kim, B.S.;Lee, C.B.;Kim, D.J.;Lee, K.H.
    • Journal of the Korean Society of Combustion
    • /
    • v.8 no.4
    • /
    • pp.1-8
    • /
    • 2003
  • In this study, the quantification of soot particles in laminar diffusion flame with LII/LIS methods was performed. In these quantification, soot diameter, number density and volume fraction are included. For the quatification of soot particles, calibration tests are needed and the development of algorithm has to be performed. So, in this study, extinction and scattering test at co-flow burner were performed to acquire calibration data. And algorithm for LII/LIS simultaneous measurement for the quantification of soot were developed. The algorithm, which was the quantification of simultaneous photographing using one ICCD camera, to measure LII/LIS signal simultaneously, the best fitted light intensity and acquisition time was needed.

  • PDF