• 제목/요약/키워드: Voltage surge and current surge

검색결과 208건 처리시간 0.029초

ZnO 나노분말로 제조한 Bi계 바리스터의 써지내량 특성 (Characteristics on the Surge Capability of Bi-based Varistor Fabricated with ZnO Nano-powder)

  • 왕민성;박춘배
    • 한국전기전자재료학회논문지
    • /
    • 제19권9호
    • /
    • pp.862-867
    • /
    • 2006
  • Bi-based nano-varistors and micro-varistors fabricated with each ZnO nano-powder and micro-powder were studied about characteristics on the surge capability in this study. ZnO nano-varistors were sintered in air at $1050^{\circ}C$ for 2 hr. The voltage-current and residual voltage properties of ZnO nano-varistor were compared with their of ZnO micrio-varistor. As a result of these properties, our ZnO nano-varistor has about 3 times at operating voltage as compared with conventional ZnO varistor fabricated with micro-powder and the residual voltage was 8.06 kV at nominal discharge current 101kA in the lighting impulse current test. And then the residual voltage rate 1.72 of our nano-varistor has had better performance than the 1.79 of micro-varistor because ZnO nano-varistor has shown much quick response property because of increasing effective cross-section area. Also, to analysis surge capability took thermal images for pyrexia temperature distribution with each of the varistors after operating varistors. Nano-varistor doesn't have shown local overheating and can confirm accurate temperature grade on the surface of its.

전력용 피뢰기의 MOV 미립화와 에너지 내량 특성 연구 (Study on Surge Absorption Capability for Power Arrester with MOV Micro-milling Characteristics)

  • 한세원;조한구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 방전 플라즈마 유기절연재료 초전도 자성체연구회
    • /
    • pp.120-124
    • /
    • 2004
  • The protection performance and energy absorption capability are important for both MOAs for distribution lines and MOAs for high voltage systems, therefore the manufacturing technique of ZnO varistor elements with high ability against surge impacts is great important for high voltage systems. But until now ZnO varistors for low voltage class have been developed in Korea, ZnO varistors with the rate discharge current of 5, 10kA class for high voltage systems depend on an import from advanced countries, such as Japan or U.S.A, which have developed its in the late 1980s. So in the aspect of taking independent technique the development of ZnO varistors with the rate discharge current of 5, 10kA class for high voltage systems is important. In this research project ZnO varistor elements with diameters of 35mm and 70mm for the rate discharge current of 5, 10kA class for high voltage systems are manufactured, then various chemical composition and processing variables affected the electrical and the physical characteristics of these ZnO varistors are investigated.

  • PDF

다양한 전류원에 대한 접지시스템의 위험전압 측정과 분석 (Measurement and Analysis of Risk Voltages by Various Current Sources in Grounding System)

  • 길경석;문병두;김황국;박대원;길형준
    • 전기학회논문지
    • /
    • 제58권1호
    • /
    • pp.113-118
    • /
    • 2009
  • Grounding systems set the reference voltage level of electric circuits and suppress the Ground Potential Rise (GPR) by flowing fault currents to the ground safely. There are several parameters which evaluate the performance of grounding systems as ground resistance, touch voltage and step voltage. The touch and step voltages, which is called "risk voltage", are especially important to ensure the safety of human body. This paper dealt with the influence of current sources with the different frequency components on the touch and the step voltages. Three types of current sources as commercial frequency, square wave, and surge with the fast risetime of $50\;ns{\sim}500\;ns$ were used to analyze the risk voltages in a grounding system. The risk voltages showed remarkable difference in the same current amplitude depending on the current sources, and increased linearly with the current amplitude in the same current source. From the experimental results, it was confirmed that the risk voltages can be evaluated by a small current application in large-scale grounding systems and the possible largest risk voltage can be calculated by a surge current with the risetime of 200 ns or a current source with the same frequency component as the surge current.

직류와 60 Hz 교류가 중첩된 전압에 대한 산화아연 피뢰기 소자의 누설전류 특성 (Characteristics of ZnO Arrester Blocks Leakage Currents under Mixed Direct and 60 Hz Alternating Voltages)

  • 이복희;강성만;박건영
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권1호
    • /
    • pp.23-29
    • /
    • 2005
  • This paper presents the characteristics of leakage currents flowing through ZinC Oxide(ZnO) surge arrester blocks under mixed direct and 60 Hz alternating voltages. A mixed voltage, in which an alternating voltage is superimposed upon a direct voltage, appears on the HVDC system network. The mixed direct and alternating voltage generator with a peak open-circuit of 10 kV was designed and fabricated. The leakage currents and V-I curves for the fine and used ZnO surge arrester blocks were measured as a function of the voltage ratio k, where the voltage ratio k is defined as the ratio of the peak of alternating voltage to the peak of the mixed voltages. The resistive component in the leakage current in the low conduction region is significantly increased with increasing the voltage ratio k. The V-I characteristic curves for the mixed voltages lies between the direct and alternating characteristics, and the cross-over phenomenon in the high conduction region was appeared.

Zn-Pr-Co-Cr-Er 산화물계 바리스터의 써지 스트레스에 대한 전기적 안정성에 미치는 소결온도의 영향 (Effect of Sintering Temperature on Electrical Stability against Surge Stress of Zn-Pr-Co-Cr-Er Oxides-based Varistors)

  • 남춘우;박종아;유대훈
    • 한국전기전자재료학회논문지
    • /
    • 제17권11호
    • /
    • pp.1167-1173
    • /
    • 2004
  • This paper reports the variations of varistor voltage, nonlinear exponent, leakage current, and dissipation factor against surge stress of ZnO-P $r_{6}$ $O_{11}$-CoO-C $r_2$ $O_3$-E $r_2$ $O_3$(ZPCCE)-based varistors manufactured with the variations of sintering temperature. It was found that the variations of electrical parameters against surge stressing current of 100 A/$\textrm{cm}^2$(8x20 ${\mu}\textrm{s}$) is not so large under the surge stress of 700 times. Among varistors, specially the varistor sintered at 134$0^{\circ}C$ exhibited the smallest variations, with %$\Delta$ $V_{lmA}$=+0.23%, %$\Delta$$\alpha$=+0.23%, %$\Delta$ $I_{L}$=0%, %$\Delta$tan$\delta$=-6.94%. The clamping voltage ratio( $V_{c}$/ $V_{lmA}$) of all varistors was less than 2.2.2.2.2.2.2.

배전급 피뢰기(18kV, 5kA)용 산화아연바리스타의 성능향상에 관한 연구 (A Study on the Improvement of ZnO Varistor for Distribution Class Surge Arrester(18kV, 5kA))

  • 유덕선;윤한수;김석수;최연규;장성도
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.744-746
    • /
    • 2003
  • A ZnO varistor with reference voltage 250V/mm was fabricated through the control of particle size in slurry and the variation of sintering conditions. It was found that to measure the flatness of the V-I characteristic curve in the small-current region and the flatness of the V-I characteristic curve in a large-current region was improved nonlinearity of the fabricated ZnO varistor. According to the IEC 60099-4 was measured the accelerated aging test and high current test of the distribution class surge varistor which is excellent in respect to the property of ZnO varistor.

  • PDF

Zn-Pr-Co-Cr-Y 산화물계 바리스터의 써지 스트레스에 대한 전기적 안정성에 소결시간의 영향 (Effect of Sintering lime on Electrical Stability against Surge Stress of Zn-Pr-Co-Cr-Y Oxide-based Varistors)

  • 남춘우;박종아;유대훈
    • 한국전기전자재료학회논문지
    • /
    • 제18권7호
    • /
    • pp.615-621
    • /
    • 2005
  • The electrical stability against surge stress of varistors, which are composed of Zn-Pr-Co-Cr-Y oxide system, were investigated at different sintering times. As sintering time increases, the varistor voltage and nonlinear exponent decreased in the range of $279.6\~179.1$ and $52.5\~24.9$, respectively. On the contrary, the leakage current and dielectric dissipation factor increased in the range of $1.2\~9.8\;{\mu}A$ and 0.0461\~0.0651 with increase of sintering time. For all varistors, the variation rates of V-I characteristic parameters against surge stress were more strongly affected in order of varistor voltage ${\rightarrow}nonlnear$ $exponent{\rightarrow}leakage$ current. On the whole, the electrical stability against surge stress increased with increasing sintering time. Conclusively, it is assumed that the varistors sintered for 2 h exhibited comparatively good characteristics, in view of overall characteristics.

전원용 SPD의 건전성 평가 장치 개발 (Development of Integrity Evaluation Instrument for the Power Line Surge Protective Device)

  • 장석훈;김영진;김성주;김재형
    • 한국안전학회지
    • /
    • 제30권4호
    • /
    • pp.39-45
    • /
    • 2015
  • This paper deals with development of integrity evaluation instrument for the power line surge protective device. A reliable power supply is an essential element in the developed information and communication society by highly advances in IT technology. However, the lightning incidence also increased with the recent extreme weather events. In Korea, in order to protect the electrical system from lightning surge, SPD(Surge Protective Device) has been used for these past 30 years. However, the method of diagnosing the safety of the SPD in the industry is insufficient. In this paper, SPD integrity evaluation system was composed of a variable DC power source unit, voltage-current sensor and the embedded controller. In order to measure V-I characteristics of MOV, 3 type samples were degraded by impulse current generator. After impulse tests, the varistor voltage of all samples and nonlinearity coefficient were decreased. It confirmed the utility of the developed equipment by this experimental test and the reliability of SPD is expected for surge accident prevention when applied to industrial plant.

종속 접속된 전압제한형 SPD의 직격뢰 서지전류에 대한 에너지협조 (Energy Coordination between Cascaded Voltage Limiting Type SPDs in Surge Currents due to Direct Lightning Flashes)

  • 이복희;엄상현
    • 조명전기설비학회논문지
    • /
    • 제28권5호
    • /
    • pp.68-75
    • /
    • 2014
  • Cascaded applications of surge protective devices(SPDs) are required in order to reduce the stress on the electrical and electronics equipment being protected, and the energy coordination between the cascaded SPDs is very important. This paper deals with the experimental results obtained from the installation conditions of full-scale SPDs. The energy coordination between the upstream Class I SPD and the downstream Class II SPD was measured using a $10/350{\mu}s$ impulse current due to direct lightning flashes. The distances between the cascaded SPDs were 3, 10, and 50m, and the maximum test current was 12.5kA. As a result, the energy sharing between cascaded SPDs was dependent on the voltage protection level of each SPD and the distance between two SPDs. An overview of how to select SPD ratings in applications of cascaded SPDs system was discussed based on the energy coordination between the two SPDs. The proposed test results for the energy coordination between two-stage cascaded SPDs can be used in effective applications of SPDs.

The Lightning Current Parameters that Impact on the Surge Analysis of the EHV Gas Insulated Substation by EMTP

  • Shim Eung-Bo;Han Sang-Ok
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제5C권1호
    • /
    • pp.1-7
    • /
    • 2005
  • This paper describes the lightning surge analysis model of extra high voltage GIS using EMTP. Various lightning current parameters were investigated in order to confirm the impact on the lightning surge analysis such as lightning current amplitude, waveform, size of GIS, tower footing resistance and surge arresters. The multi-story tower model and EMTP/TACS model were introduced for the simulation of dynamic arc characteristics. The margin between the maximum overvoltage and BIL of the GIS was about 10 percent and the margin between the maximum overvoltage and BIL of the transformer was 21 percent.