• Title/Summary/Keyword: Voltage quality control

Search Result 459, Processing Time 0.026 seconds

A Novel Analytical Method for Selective Harmonic Elimination Problem in Five-Level Converters

  • Golshan, Farzad;Abrishamifar, Adib;Arasteh, Mohammad
    • Journal of Power Electronics
    • /
    • v.17 no.4
    • /
    • pp.914-922
    • /
    • 2017
  • Multilevel converters have attracted a lot of attention in recent years. The efficiency parameters of a multilevel converter such as the switching losses and total harmonic distortion (THD) mainly depend on the modulation strategy used to control the converter. Among all of the modulation techniques, the selective harmonic elimination (SHE) method is particularly suitable for high-power applications due to its low switching frequency and high quality output voltage. This paper proposes a new expression for the SHE problem in five-level converters. Based on this new expression, a simple analytical method is introduced to determine the feasible modulation index intervals and to calculate the exact value of the switching angles. For each selected harmonic, this method presents three-level or five-level waveforms according to the value of the modulation index. Furthermore, a flowchart is proposed for the real-time implementation of this analytical method, which can be performed by a simple processor and without the need of any lookup table. The performance of the proposed algorithm is evaluated with several simulation and experimental results for a single phase five-level diode-clamped inverter.

Determination of Recombinant Human Epidermal Growth factor (rhEGF) in a Pharmaceutical Preparation by Capillary Electrophoresis

  • Hwang, Kyung-Hwa;Lee, Kang-Woo;Kim, Chang-Soo;Han, Kun;Chung, Youn-Bok;Moon, Dong-Cheul
    • Archives of Pharmacal Research
    • /
    • v.24 no.6
    • /
    • pp.601-606
    • /
    • 2001
  • A simple assay method of recombinant human epidermal growth factor (rhEGF) in a pharmaceutical preparation was studied and validated by capillary electrophoresis (CE) using micellar electrokinetic chromatography (MEKC) techniques. Factors affecting the migration behavior and separation performances of the peptide; type of buffers pH, butler concentration, and concentration of sodium dodecyl sulfates (SDS) were investigated to optimize the analytical performance. CE was performed using running buffers 50.0 mM borate (pH 8.5) containing 12.5 mM SDS at 20 $mutextrm{V}$ of the applied voltage. Calibration curves for the rhEGF showed good linearity (r>0.999) over the wide dynamic range from 1.25 to $100{\mu\textrm{g}}/ml$. Sample analysis was performed by using standard addition method to eliminate the matrix effects of dosage vehicle. This method is assumed to be useful for quality control (QC) of various forms of pharmaceutical products of the peptide.

  • PDF

Simulation Study for a UV Water Disinfection Unit Powered by a Photovoltaic System

  • Riahi, Said;Mami, Abdelkader;Minzu, Viorel
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.1
    • /
    • pp.175-182
    • /
    • 2022
  • This work presents a simulation model for a specific UV disinfection system (UVDS) powered by a Photovoltaic System. The global UVDS also includes the electronic converters, Electronic Ballast, UV Lamp and Motor Pump. The equations that model the physical components' behaviour are connected to obtain a dynamic global model. The latter is converted in a Simulink/Matlab model, which allows to carry out simulation series concerning the entire UVDS. The physical parameters: the irradiation G and the temperature T, are considered as inputs. series of measurements carried out in order to show how these parameters affect the current, the voltage of the PVs and especially the value of the current of the UV lamp, on the other hand a study on the behavior and the evolution of the parameters of the motor pump such as the armature current, motor torque, speed of rotation and the water flow. The purpose of all this is to realize how important are the two parameters concerning the lamp current and the water flow because they are two very important factors to keep an adequate water quality.

A Study on Detecting and Monitoring of Weld Root Gap using Neural Networks (신경회로망을 이용한 용접 Root Gap 검출과 모니터링에 관한연구)

  • Kang Sung-In;Kim Gwan-Hyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.7
    • /
    • pp.1326-1331
    • /
    • 2006
  • Weld root gap is a important fact of a falling-off weld quality in various kind of weld defect. The welding quality can be controlled by monitoring important parameters, such as, the Arc voltage, welding current and welding speed during the welding process. Welding systems use either a vision sensor or an Arc sensor, both of which are unable to control these parameters directly. Therefore, it is difficult to obtain necessary bead geometry without automatically controlling the welding parameters through the sensors. In this paper we propose a novel approach using neural networks for detecting and monitoring of weld root gap and bead shape. Through experiments we demonstrate that the proposed system can be used for real welding processes. The results demonstrate that the system can efficiently estimate the weld bead shape and detect the welding defects.

Optimal Voltage Management Based on the Flexible, Reliable, Intelligent and Energy-conservative Distribution System (FRIENDS) (차세대 전기에너지공급시스템(FRIENDS)에 의한 최적 전압관리방안에 관한 연구)

  • 노대석
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.4 no.4
    • /
    • pp.409-417
    • /
    • 2003
  • In recent years, better quality in power electric services is being required with the development of information industries and the improvement of living standards. Also, the small scaled dispersed storage and generation (DSG) systems are being interconnected with the distribution systems and customers by the influence of the recent issues such as deregulation and global environmental problems in power system. Under these circumstances, it is very important to maintain the customer voltages within allowable limits for the distribution system which is located at the most sensitive part in the power system. To overcome these problems, this paper shows the basic concepts of FRIENDS which is considered as one of the power delivery system in the near future and also presents an evaluation method on the impacts of customer voltages by operation models of FRIENDS. The FRIENDS can change the system configuration in a flexible manner by using the static switches and offer the different power qualities in power services through the power quality control centers which play the most important role in FRIENDS. Numerical examples are shown in order to indicate the efficiency of the proposed method.

  • PDF

Performance Analysis of load simulator interconnected with Power Quality Compensator (전력품질 보상기와 부하모의장치의 연계시험 분석)

  • Bae, Byung-Yeol;Cho, Yun-Ho;Park, Yong-Hee;Han, Byung-Moon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.89-97
    • /
    • 2007
  • This paper describes a load simulator with power recovery capability, which is based on the voltage source converter-inverter set. The load simulator can save the electric energy that should be consumed to test the operation and performance of the power quality compensator and the power equipment. The load simulator consists of a converter-inverter set with a DSP controller for system control and PWM pulse generation. The converter operates as a universal load to model the linear load and the non-linear load, while the inverter feed the energy back to the power source with harmonic compensation. the performance of proposed load simulator was analyzed with scaled-model experiment, interconnected with the active power filter. The experimental results confirms that the proposed load simulator can be utilized to test the performance of active power filter.

Performance Evaluation of an Electrometer for Quality Control and Dosimetry in Radiation Therapy (방사선 치료의 정도관리 및 선량측정에 이용되는 전리계의 성능평가)

  • Kim, Chang-Seon;Kim, Chul-Yong;Park, Myung-Sun
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.123-130
    • /
    • 2000
  • The performance of an electrometer directly affects on the accuracy and precision in radiation dosimetry. This study is to list of the quality control for maintaining performance and to perform evaluation tests of an electrometer. Performance tests selected include proper polarizing voltages, warm-up and equalization time, leakages, long-term stability, linearity, and effect of ambient conditions. An electrometer connected with a rigid stem ionization chamber was evaluated with a Strontium-90 check device. Bias voltage was measured directly on the input socket. Equalization time is the time required for reaching threshold of charged state after the power is on or the bias voltage is changed. Pre- and post-signal leakages are defined as the accumulation of signal with no exposure and after exposure, respectively. Over three months period, the electrometer's long-term stability was measured by comparison of the temperature-pressure corrected readings. Linearity was expressed as the deviation of readings from multiple short exposures from one continuous exposure. Effect of ambient conditions was expressed as the zero drift of the electrometer over 17-34$^{\circ}C$ temperature ranges. For two nominal values, 300 and 500 volts, measured voltages were lower by 2.5 and 5.8%, respectively. The warm-up time, 20 minutes, was longer than the lamp time by 9 minutes and the equalization time was less than 1 minute. Without exposure, the zero-drift was 0.002 scale-unit in 15 minutes and the leakage after 10 minutes exposure was minimal. The IQ-4 was stable over 99.4% for three-month periods. Deviation from the linearity was 0.9% for measurement scale, 0.000-9.991. Over 17-34$^{\circ}C$ temperature range, the zero-drift was minimal, less than 0.2%. For a clinically-used electrometer, a list for the basic peformance evaluations is proposed. By running this program, the measurement error using an electrometer can be reduced and in turn the improvement in accuracy and precision of radiation dosimetry can be achieved.

  • PDF

Optimal Design of VCO Using Spiral Inductor (나선형 인덕터를 이용한 VCO 최적설계)

  • Kim, Yeong-Seok;Park, Jong-Uk;Kim, Chi-Won;Bae, Gi-Seong;Kim, Nam-Su
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.5
    • /
    • pp.8-15
    • /
    • 2002
  • We optimally designed the VCO(voltage-controlled oscillator) with spiral inductor using the MOSIS HP 0.5${\mu}{\textrm}{m}$ CMOS process. With the developed SPICE model of spiral inductor, the quality factor of spiral inductor was maximized at the operating frequency by varying the layout parameters, e.g., metal width, number of turns, radius, space of the metal lines. For the operation frequency of 2㎓, the inductance of about 3nH, and the MOSIS HP 0.5 CMOS process with the metal thickness of 0.8${\mu}{\textrm}{m}$, oxide thickness of 3${\mu}{\textrm}{m}$, the optimal width of metal lines is about 20${\mu}{\textrm}{m}$ for the maximum Quality factor. With the optimized spiral inductor, the VCO with LC tuning tank was designed, fabricated and measured. The measurements were peformed on-wafer using the HP8593E spectrum analyzer. The oscillation frequency was about 1.610Hz, the frequency variation of 250MHz(15%) with control voltage of 0V - 2V, and the phase noise of -108.4㏈c(@600KHz) from output spectrum.

A Quality Assurance on Digital Chest Radiography in Medical Institution for Pneumoconiosis : Compared with Analog Radiography (진폐요양기관의 흉부 디지털촬영과 아날로그촬영의 정도관리 비교)

  • Lee, Won-Jeong;Ko, Kyung-Sun;Park, Jai-Soung;Kim, Sung-Jin;Chu, Sang-Deok;Park, So-Young;Choi, Byung-Soon
    • Journal of radiological science and technology
    • /
    • v.33 no.2
    • /
    • pp.85-91
    • /
    • 2010
  • Digital radiography has been replacing rapidly the analog radiography for diagnosis of pneumoconiosis. The purpose of this study is to compare quality control of digital radiography (DR) and analog radiography (AR) for chest radiography in medical institution for pneumoconiosis (MIP) For the first time, we visited MIP to evaluate the chest radiography which is used for patients with pneumoconiosis, including equipment, technical parameters and reading environment. There were 33 institutions. DR and AR were installed in 24 and 9 institutions, respectively. Between DR and AR, we compared the radiological technique (RT), image quality (IQ) and reading environment (RE) to use the guideline published by Occupational Safety and Health Research Institute (OSHRI). The image quality was rated by two experienced chest radiologists for pneumoconiosis with certified from OSHRI. The chest radiography equipment was not significantly difference between AR and DR, but there were significantly difference in tube voltage and grid ratio used for chest radiography except to tube current, exposure time. Statistically, DR is significantly higher in RT(70.3 vs. 43.8, p = 0.009), RE(77.7 vs. 33.3, p = 0.004) than AR, but it's not significantly difference in IQ (65.6 vs. 52.8, p = 0.050). AR and DR in RT were passed 33.3%, 75.0% respectively (p = 0.044) and 44.4%, 79.2% (p = 0.090) in IQ and 44.4%, 91.7% (p = 0.009) in RE. In MIP, DR needs to replace AR in diagnosis of pneumoconiosis.

Approximate SHE PWM for Real-Time Control of 2-Level Inverter (3레벨 인버터의 실시간 제어를 위한 근사화 SHE PWM)

  • 박영진;홍순찬
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.4
    • /
    • pp.365-374
    • /
    • 1998
  • The SHE(Selected Harmonic Elimination) PWM scheme which eliminates specific lower order harmonics can generate h high quality output waveforms in 3-level PWM inverters. However. its application has limited since SHE switching a angles cannot be calculated on-line by a microprocessor-implemented control system. Based on off-line optimization. in which multiple SHE solutions were found and analysed for 2 to 5 switching angles per quarter in the 3-level SHE PWM pattern. this paper presents an algebraic algorithm for an ordinary microprocessor to calculate approximate SHE S switching angles on-line with such high resolution that it makes no practical difference between the accurate and the a approximate SHE switching angles. By employing the variable of the dc-link voltage Vdc' the proposed SHE PWM p pattern can ideally compensate the dc input fluctuation together with selected harmonics eliminated.

  • PDF