• Title/Summary/Keyword: Voltage quality

Search Result 1,545, Processing Time 0.026 seconds

Improved Evaluation Method of Flicker considering Disturbances of Power System

  • Kim, Jae-Chul;Moon, Jong-Fil;Jung, Seung-Bock;Choe, Kyu-Ha
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.3
    • /
    • pp.8-14
    • /
    • 2008
  • This paper studies a more exact flicker evaluation method by detecting power quality disturbances and excluding the effects of power quality disturbances. Up to the present, power quality disturbances affect flicker evaluation index because power quality problems do not have been considered. However, flick index should represent only flicker without power quality disturbances. Thus, in this paper, we present the improved flicker evaluation method which removing the effects of power quality disturbances such as voltage sag and transient caused by fault and inverter/breaker switching. We detect voltage sag and transient using wavelet transform and remove the effects of power quality disturbances from flicker index.

An 18-Pulse Full-Wave AC-DC Converter for Power Quality Improvement

  • Singh, Bhim;Gairola, Sanjay
    • Journal of Power Electronics
    • /
    • v.8 no.2
    • /
    • pp.109-120
    • /
    • 2008
  • In this paper, a novel delta/double-fork transformer based 18-pulse full-wave AC-DC converter is designed, modeled, simulated and developed to feed isolated DC varying loads. The proposed AC-DC converter is used for low voltage and large current DC loads in applications such as electrowinning, where isolation is required mainly for stepping down the supply voltage. The proposed converter improves power quality at AC mains and meets IEEE-519 standard requirements at varying loads.

PID control of the voltage sag compensator in three-phase unbalanced system (3상 불평형 시스템에서 순간전압 강하 보상기의 PID제어)

  • Choi, Hyen-Young;Park, Jung-Gyun;Oh, Se-Ho;Lee, Yong-Gea;Kim, Yang-Mo
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1078-1080
    • /
    • 2002
  • High electronic equipments for dem-and improvement and efficiency are requested power quality of superior quality, the compensation system of power quality is processing actively, when voltage sag occurs, we propose to a series voltage compensator and control algorithm using of pid control in unbalanced 3-phase power system.

  • PDF

A Three-Phase Four-Wire DSTATCOM for Power Quality Improvement

  • Singh, Bhim;Jayaprakash, P.;Kothari, D.P.
    • Journal of Power Electronics
    • /
    • v.8 no.3
    • /
    • pp.259-267
    • /
    • 2008
  • Power quality improvement in a three-phase four-wire system is achieved using a new topology of DSTATCOM (distribution static compensator) consisting of a star/delta transformer with a tertiary winding and a three-leg VSC (voltage source converter). This new topology of DSTATCOM is proposed for power factor correction or voltage regulation along with harmonic elimination, load balancing and neutral current compensation. A tertiary winding is introduced in each phase for a delta connected secondary in addition to the star-star windings and this delta connected winding is responsible for neutral current compensation. The dynamic performance of the proposed DSTATCOM system is demonstrated using MATLAB with its Simulink and Power System Blockset (PSB) toolboxes under varying loads. The capacitor supported DC bus of the DSTATCOM is regulated to the reference voltage under varying loads.

A Study on the Economical PQMS of the Utility Distribution Power System (전력회사 관점의 배전계통 경제형 PQM 시스템 구축방안)

  • Park, Yong-Up;Lee, Keon-Hang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.9
    • /
    • pp.1523-1529
    • /
    • 2010
  • This paper describes the distribution power system econimical PQMS(Power quality monitoring system) of Utility. Recently, the korea power quality standard has been established based on the IEC Std. By IEC Std., the power quality assessment point is measured in PCC(Point of common coupling). In this case, the utility has to construct PQM system in all customer PCC point and the PQ meter cost would be very high in order to acquire the suitable data. Also the distribution system would be encounter the communication overload problem due to the huge data. Accordingly the utilities could not apply to PQM system in the distribution power system by the cost and communication problem. In this paper, the proposed economical PQMS has the voltage and current signal reiteration function and FFT operation function is transferred the server. Also the voltage and current measurement channels are minimized by a classified substation construction.

Development of Countermeasure for Improving the Power Quality using Coordinated Control of BESS on Electric Vehicle connected System (전기 자동차 계통 연계 시 BESS의 협조제어를 이용한 전력품질 향상 대책 개발)

  • Lee, Soon-Jeong;Kim, Sang-Won;Kim, Jun-Hyeok;Kim, Chul-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.6
    • /
    • pp.63-69
    • /
    • 2015
  • Energy Storage Systems (ESSs) are essential in the future power systems because they can improve power usage efficiency. In this paper, we propose the countermeasure for improving the power quality using coordinated control of BESS(Battery Energy Storage System) on EV connected system. To verify the performance of proposed scheme, we simulate on the actual power system of KEPCO and compare the results of voltage variation, frequency variation, and load factor with those of uncoordinated control. From the simulation results, we confirm that frequency and voltage deviation are significantly reduced with proposed coordinated control of BESS.

Development of Microcomputer-Based On-Line Monitoring System of Spot Weld Quality (마이크로 컴퓨터를 이용한 온라인 점용접 품질 감시체제 개발에 관한 연구)

  • 김교형
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.2
    • /
    • pp.241-246
    • /
    • 1986
  • A new method of on-line monitoring of spot weld quality is proposed by analysing weld votage signal. Weld voltage signal has been modeled by autoregressive model which is suitable for on-line modeling scheme, and order of the model is determined by F-test. From the chosen model, strength. Upon experimental results, it has been shown that fundamental frequency dispersion of weld voltage can be used as a good parameter like maximum thermal expansion in on-line monitoring of spot weld quality. Microcomputer implementation of the proposed monitoring method is also developed and presented.

Voltage sag compensator of a high and precise quality for unbalanced three phase power system

  • Park, Hyen-Young;Oh, Se-Ho;Lee, Kyo-Sung;Kim, Do-Hun;Kim, Yang-mo
    • Proceedings of the IEEK Conference
    • /
    • 2002.07c
    • /
    • pp.1394-1397
    • /
    • 2002
  • High electronic equipments for demand improvement and efficiency are requested the power superior quality. The compensation system of power quality is processing actively. We propose to a series voltage compensator and control algorithm using pid control in unbalanced three- phase power system when voltage sag occurs.

  • PDF

Power Quality Compensate System Using Photovoltaic System (태양광발전 시스템을 이용한 전력품질 보상시스템)

  • Han S.W.;Choe G.H.;Jang D.H.;Shin W.S.;Kim H.G.
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.76-80
    • /
    • 2001
  • Voltage harmonics resulting from current harmonies produced by the nonlinear loads have become a serious problems in many systems. Moreover momentary interruptions and voltage sags are responsible for many of the power quality problems found in typical industrial plants. In this paper, proposed power quality compensate system using photovoltaic system is not only for harmonic compensation but also for harmonic isolation between supply and load, and for voltage regulation and unbalance compensation. Through computer simulations, we have verified the effectiveness of the proposed system.

  • PDF

Optimization of Image Quality according to Sensitivity and Tube Voltage in Chest Digital Tomosynthesis (디지털 흉부단층합성검사에서 감도와 관전압 변화에 따른 영상 최적화)

  • Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.541-547
    • /
    • 2018
  • To evaluate the effect of dose and image quality for Chest Digital Tomosynthesis(CDT) using sensitivity and tube voltage(kV). CDT images of the phantom were acquired varying sensitivity 200, 320, 400 according to set tube voltage of 125 kV and 135 kV. The dose and Dose Area Product(DAP) according to change of sensitivity and kV were evaluated and Image quality was evaluated by PSNR, CNR, SNR using Image J. Dose were lowered 14~23% less than sensitivity 200, 125 kV and DAP were lowered 13~26% less than sensitivity 200, 125 kV. PSNR were over 27 dB, which were significant value and CNR, SNR were better as sensitivity value was lower. But there were different statistical significant to each item. CNR and SNR were not statistically significant at sensitivity 320, 135 kV(P>0.05). CDT can improve image quality with lower radiation dose using better than quality and correction power at digital radiography system.