• 제목/요약/키워드: Voltage Transfer Function

검색결과 176건 처리시간 0.023초

N-Input NAND Gate에서 입력조건에 따른 Voltage Transfer Function에 관한 연구 (A Study of The Voltage Transfer Function Dependent On Input Conditions For An N-Input NAND Gate)

  • 김인모;송상헌;김수원
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권10호
    • /
    • pp.510-514
    • /
    • 2004
  • In this paper, we analytically examine the voltage transfer function dependent on input conditions for an N-Input NAND Gate. The logic threshold voltage, defined as a voltage at which the input and the output voltage become equal, changes as the input condition changes for a static NAND Gate. The logic threshold voltage has the highest value when all the N-inputs undergo transitions and it has the lowest value when only the last input connected to the last NMOS to ground, makes a transition. This logic threshold voltage difference increases as the number of inputs increases. Therefore, in order to provide a near symmetric voltage transfer function, a multistage N-Input Gate consisting of 2-Input Logic Gates is desirable over a conventional N-Input Gate.

벡터 곱에 근거한 에너지함수 유도와 선로 컨덕턴스 및 커패시터를 포함한 전력시스템에의 적용 연구 (Derivation of an Energy Function Based on Vector Product and Application to the Power System with Transfer Conductances and Capacitors)

  • 문영현;오용택;이병하
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권6호
    • /
    • pp.274-283
    • /
    • 2005
  • This paper presents a new method to derive energy function based on vector product. Using this method, an energy function to consider transfer conductances and capacitors is derived. Then we recommend a voltage collapse criteria to predict the voltage collapse in power systems by using the energy margin derived by the proposed energy function. This energy function is applied to a 2-bus power system reflecting transfer conductances and capacitors. We show that the energy function derived based on vector product can be applied in order to analyze power system stability and the energy margin can be utilized as a criterion of voltage collapse by simulation for the 2-bus system.

Realization of n-th Order Voltage Transfer Function Using a Single Operational Transresistance Amplifier

  • Kilinc, Selcuk;Cam, Ugur
    • ETRI Journal
    • /
    • 제27권5호
    • /
    • pp.647-650
    • /
    • 2005
  • A new configuration to realize the most general n-th order voltage transfer function is proposed. It employs only one operational transresistance amplifier (OTRA) as the active element. In the synthesis of the transfer function, the RC:-RC decomposition technique is used. To the best of author's knowledge, this is the first topology to be used in the realization of n-th order transfer function employing single OTRA.

  • PDF

선로저항을 반영하는 에너지함수 유도를 위한 등가시스템 기법의 개발 (The Development of Equivalent System Technique for Deriving an Energy Function Reflecting Transfer Conductances)

  • 문영현;조병훈;노태훈;최병곤
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권10호
    • /
    • pp.1175-1182
    • /
    • 1999
  • This paper shows that a well-defined energy function can be developed to reflect the transfer conductances for multi-machine power systems under an assumption that all transmission lines have uniform R/X rations. The energy function is derived by introducing a pure reactive equivalent system for the given system. In this study, a static energy function reflecting transfer conductances is also derived as well as the transient energy function. The proposed static energy function is applied to voltage stability analysis and tested for various sample systems. The test results show that the accuracy of voltage stability analysis can be considerable improved by reflecting transfer conductances into the energy function.

  • PDF

비시변 시비율 전달함수 구현에 의한 양방향 충전기 제어특성 개선 (Implementation of Non-time-varying Duty Ratio Transfer Function for Improvement of Control Characteristics Bi-directional Charger)

  • 황정구;김선필;한상택;김기선;추영배;박성준
    • 전력전자학회논문지
    • /
    • 제19권2호
    • /
    • pp.124-132
    • /
    • 2014
  • In this paper, we implement a non-time-varying transfer function of the duty ratio to improve the control characteristics in a control system that Input voltage and the output voltage is varied, DC / DC converters for bi-directional charging. When control is performed with using controller gain of conventional design, characteristics of the control is varied to fluctuations of the input voltage. The proposed method is the equivalently removing method for duty ratio in entire control block, by voltage controller gain is changed for inverse of the duty ratio. The proposed non-time-varying duty ratio transfer function is applied to DC / DC converter for bi-directional charging. In this paper, feasibility and superiority is verified through PSIM simulations and experiments.

Study on the Transfer Functions for Detecting Windings Displacement of Power Transformers with Impulse Method

  • Shon, Chae-Hwa;Yi, Sang-Hwa;Lee, Heun-Jin;Kang, Dong-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권6호
    • /
    • pp.876-883
    • /
    • 2012
  • The paper investigates three types of transfer function methods for detecting displacements of winding in a model transformer. To acquire these transfer functions, the measuring method of input voltage, current and its response is used in impulse method. The applied impulse voltages had three rising times, which were short rising time (less than 0.6 ${\mu}s$), medium rising time (about 0.8 ${\mu}s$) and long rising time (about 1 ${\mu}s$) in front waves. Every 10 measurements of voltage and current waves were averaged from 50 measurements of voltage and current waves. These transfer functions were tested in normal, 24mm elevated and 48mm elevated windings conditions and were analyzed with correlation coefficients and spectrum deviations. In the analysis, the results depend on the types of transfer functions and the rising times of input voltages.

철도차량 보조전원장치의 순시전압제어 (Instantaneous Voltage Control Scheme of Auxiliary Power Supply System for Electric Railway Vehicles)

  • 김재식;최재호;임성수;이은규
    • 전력전자학회논문지
    • /
    • 제4권4호
    • /
    • pp.349-356
    • /
    • 1999
  • 본 논문에서는 철도차량용 보조전원장치에 순시전압제어기법을 적용할 때 발생하는 문제들의 해결방안을 제시한다. 비선형부하나 과도상태에서 빠른 응답특성을 얻기 위해 순시전압제어기법을 사용할 때 LC 필터의 공진문제와 존재하는 정상상태 오차가 더욱 심각해진다. 인버터 출력측 LC 필터에 기인하는 공진현상을 억제하기 위해 전압전달함수의 제동비를 증가시키기 위한 방안으로 필터 커패시터 궤환제어기가 고려되었다. 그리고 교류전압 순시제어시 존재하는 정상상태 오차를 제거하기 위하여 고이득 전달함수를 기존의 PI 제어기에 첨가하였다. 이론적인 분석이 시뮬레이션 결과와 함께 잘 설명되어져 있다. 제안된 기법의 타당성을 5kVA급 시제품에 대한 시뮬레이션과 실험을 통하여 입증하였다.

  • PDF

에너지함수법을 이용한 가용송전용량(ATC) 계산에 관한 연구 (A study on the ATC(Available Transfer Capabilily) calculation using an Energy Function Method)

  • 김재현;정성원;김양일
    • 조명전기설비학회논문지
    • /
    • 제22권2호
    • /
    • pp.94-100
    • /
    • 2008
  • 가용송전용량(ATC)은 계통내의 한 지역에서 다른 지역까지 실제 전력을 증가시키는 것이다. 지금까지 ATC 계산은 대부분 정상상태에서 실행가능성을 주로 고려하여 계산되어 왔다. 하지만 ATC 평가시 과도안정도로 제약된 ATC 계산은 매우 중요한 부분이다. ATC 평가시에는 제약조건으로 열적용량, 전압 및 과도안정도로 제약된 상정사고(n-1)시 안전도 평가가 요구된다. 본 논문은 자코비안 행렬의 고유치를 이용하여 상정사고 우선순위를 선정하였고, 에너지 함수법을 이용하여 선로의 열적용량, 전압안정도 및 과도안정도를 고려한 ATC를 계산하였다.

부하전류 전향보상기를 이용한 강압쵸퍼의 동특성 제어 (Dynamic Characteristics Control of a Step-down Chopper Using Load current Feed-forward Compensator)

  • 전춘병;전지용;전기영;한경희
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.66-69
    • /
    • 2008
  • In this paper, The author present a load current feed-forward compensator by method that improve voltage controller of Step-down Chopper to get stable output voltage to sudden change of load current. To confirm the characteristicsof a presented load current feed -forward compensator compared each transfer function of whole system that load current feed-forward compensator is added with transfer function of whole system that existent voltage controller is included using Mason gains formula in Root locus and Bode diagram. As a result the pole of system is improved, extreme point of the wave and system improves, and size of peak value and phase margin of break frequency in resonance frequency confirmed that is good. Therefore, presented control technique could confirm that reduce influence by perturbation and improves stationary state and dynamic characteristics in output of Step-down Chopper.

  • PDF

A Cross Regulation Analysis for Single-Inductor Dual-Output CCM Buck Converters

  • Wang, Yao;Xu, Jianping;Zhou, Guohua
    • Journal of Power Electronics
    • /
    • 제16권5호
    • /
    • pp.1802-1812
    • /
    • 2016
  • Cross regulation is a key technical issue of single-inductor multiple-output (SIMO) DC-DC converters. This paper investigates the cross regulation in single-inductor dual-output (SIDO) Buck converters with continuous conduction mode (CCM) operation. The expressions of the DC voltage gain, control to the output transfer function, cross regulation transfer function, cross coupled transfer function and impedance transfer function of the converter are presented by the time averaging equivalent circuit approach. A small signal model of a SIDO CCM Buck converter is built to analyze this cross regulation. The laws of cross regulation with respect to various load conditions are investigated. Simulation and experiment results verify the theoretical analysis. This study will be helpful for converter design to reduce the cross regulation. In addition, a control strategy to reduce cross regulation is performed.