• Title/Summary/Keyword: Voltage Transfer Function

Search Result 176, Processing Time 0.022 seconds

A Study of The Voltage Transfer Function Dependent On Input Conditions For An N-Input NAND Gate (N-Input NAND Gate에서 입력조건에 따른 Voltage Transfer Function에 관한 연구)

  • Kim In-Mo;Song Sang-Hun;Kim Soo-Won
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.10
    • /
    • pp.510-514
    • /
    • 2004
  • In this paper, we analytically examine the voltage transfer function dependent on input conditions for an N-Input NAND Gate. The logic threshold voltage, defined as a voltage at which the input and the output voltage become equal, changes as the input condition changes for a static NAND Gate. The logic threshold voltage has the highest value when all the N-inputs undergo transitions and it has the lowest value when only the last input connected to the last NMOS to ground, makes a transition. This logic threshold voltage difference increases as the number of inputs increases. Therefore, in order to provide a near symmetric voltage transfer function, a multistage N-Input Gate consisting of 2-Input Logic Gates is desirable over a conventional N-Input Gate.

Derivation of an Energy Function Based on Vector Product and Application to the Power System with Transfer Conductances and Capacitors (벡터 곱에 근거한 에너지함수 유도와 선로 컨덕턴스 및 커패시터를 포함한 전력시스템에의 적용 연구)

  • Moon Young-Hyun;Oh Yong-Taek;Lee Byung Ha
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.6
    • /
    • pp.274-283
    • /
    • 2005
  • This paper presents a new method to derive energy function based on vector product. Using this method, an energy function to consider transfer conductances and capacitors is derived. Then we recommend a voltage collapse criteria to predict the voltage collapse in power systems by using the energy margin derived by the proposed energy function. This energy function is applied to a 2-bus power system reflecting transfer conductances and capacitors. We show that the energy function derived based on vector product can be applied in order to analyze power system stability and the energy margin can be utilized as a criterion of voltage collapse by simulation for the 2-bus system.

Realization of n-th Order Voltage Transfer Function Using a Single Operational Transresistance Amplifier

  • Kilinc, Selcuk;Cam, Ugur
    • ETRI Journal
    • /
    • v.27 no.5
    • /
    • pp.647-650
    • /
    • 2005
  • A new configuration to realize the most general n-th order voltage transfer function is proposed. It employs only one operational transresistance amplifier (OTRA) as the active element. In the synthesis of the transfer function, the RC:-RC decomposition technique is used. To the best of author's knowledge, this is the first topology to be used in the realization of n-th order transfer function employing single OTRA.

  • PDF

The Development of Equivalent System Technique for Deriving an Energy Function Reflecting Transfer Conductances (선로저항을 반영하는 에너지함수 유도를 위한 등가시스템 기법의 개발)

  • Moon, Young-Hyun;Cho, Byoung-Hoon;Roh, Tae-Hoon;Choi, Byoung-Kon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.10
    • /
    • pp.1175-1182
    • /
    • 1999
  • This paper shows that a well-defined energy function can be developed to reflect the transfer conductances for multi-machine power systems under an assumption that all transmission lines have uniform R/X rations. The energy function is derived by introducing a pure reactive equivalent system for the given system. In this study, a static energy function reflecting transfer conductances is also derived as well as the transient energy function. The proposed static energy function is applied to voltage stability analysis and tested for various sample systems. The test results show that the accuracy of voltage stability analysis can be considerable improved by reflecting transfer conductances into the energy function.

  • PDF

Implementation of Non-time-varying Duty Ratio Transfer Function for Improvement of Control Characteristics Bi-directional Charger (비시변 시비율 전달함수 구현에 의한 양방향 충전기 제어특성 개선)

  • Hwang, Jung-Goo;Kim, Sun-Pil;Han, Sang-Taek;Kim, Ki-Seon;Choo, Young-Bae;Park, Sung-Jun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.124-132
    • /
    • 2014
  • In this paper, we implement a non-time-varying transfer function of the duty ratio to improve the control characteristics in a control system that Input voltage and the output voltage is varied, DC / DC converters for bi-directional charging. When control is performed with using controller gain of conventional design, characteristics of the control is varied to fluctuations of the input voltage. The proposed method is the equivalently removing method for duty ratio in entire control block, by voltage controller gain is changed for inverse of the duty ratio. The proposed non-time-varying duty ratio transfer function is applied to DC / DC converter for bi-directional charging. In this paper, feasibility and superiority is verified through PSIM simulations and experiments.

Study on the Transfer Functions for Detecting Windings Displacement of Power Transformers with Impulse Method

  • Shon, Chae-Hwa;Yi, Sang-Hwa;Lee, Heun-Jin;Kang, Dong-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.6
    • /
    • pp.876-883
    • /
    • 2012
  • The paper investigates three types of transfer function methods for detecting displacements of winding in a model transformer. To acquire these transfer functions, the measuring method of input voltage, current and its response is used in impulse method. The applied impulse voltages had three rising times, which were short rising time (less than 0.6 ${\mu}s$), medium rising time (about 0.8 ${\mu}s$) and long rising time (about 1 ${\mu}s$) in front waves. Every 10 measurements of voltage and current waves were averaged from 50 measurements of voltage and current waves. These transfer functions were tested in normal, 24mm elevated and 48mm elevated windings conditions and were analyzed with correlation coefficients and spectrum deviations. In the analysis, the results depend on the types of transfer functions and the rising times of input voltages.

Instantaneous Voltage Control Scheme of Auxiliary Power Supply System for Electric Railway Vehicles (철도차량 보조전원장치의 순시전압제어)

  • 김재식;최재호;임성수;이은규
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.4
    • /
    • pp.349-356
    • /
    • 1999
  • This paper presents an instantaneous voltage control scheme of au킹liary power supply system for the electric railway v vehicles, The resonance problem of the LC filter and the existing steady state error are more serious as the use of l instantaneous voltage control techniques for the fast transient response at the nonlinear load, A filter capacitor current f feedback loop is considered to increase the damping ratio of the voltage transfer function for the suppression of the resonance problem of the LC inverter output filter. To eliminate the steady state en‘or existing in case of the AC l instantaneous voltage control. the high gain transfer function is added to the conventional PI controller. The theoretical a analysis is well described with the simulation results. The validity of the proposed schemes is well verified through the s simulation and expelimental results for the 5 kVA prototype.

  • PDF

A study on the ATC(Available Transfer Capabilily) calculation using an Energy Function Method (에너지함수법을 이용한 가용송전용량(ATC) 계산에 관한 연구)

  • Kim, Jae-Hyeon;Jeong, Sung-Won;Kim, Yong-Il
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.2
    • /
    • pp.94-100
    • /
    • 2008
  • Available transfer capability(ATC) quantifies the viable increase in real power transfer from one point to another in a power system. ATC calculation has predominantly focussed on steady-state viability. But ATC assessment with transient stability constraints has a dominant part in overall ATC calculation. ATC assessment requires a reputation of (n-1) security assessment with constraints of thermal limits, voltage stability and dynamic stability. An estimation of determinant contingency screening method is used for computing eigenvalue of Jacobian matrix. This paper proposed a methods to ATC calculation using energy function. Constraints is used thermal limits, voltage stability and transient stability.

Dynamic Characteristics Control of a Step-down Chopper Using Load current Feed-forward Compensator (부하전류 전향보상기를 이용한 강압쵸퍼의 동특성 제어)

  • Chung, Chun-Byung;Chun, Ji-Yong;Jeon, Kee-Young;Han, Kyung-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.66-69
    • /
    • 2008
  • In this paper, The author present a load current feed-forward compensator by method that improve voltage controller of Step-down Chopper to get stable output voltage to sudden change of load current. To confirm the characteristicsof a presented load current feed -forward compensator compared each transfer function of whole system that load current feed-forward compensator is added with transfer function of whole system that existent voltage controller is included using Mason gains formula in Root locus and Bode diagram. As a result the pole of system is improved, extreme point of the wave and system improves, and size of peak value and phase margin of break frequency in resonance frequency confirmed that is good. Therefore, presented control technique could confirm that reduce influence by perturbation and improves stationary state and dynamic characteristics in output of Step-down Chopper.

  • PDF

A Cross Regulation Analysis for Single-Inductor Dual-Output CCM Buck Converters

  • Wang, Yao;Xu, Jianping;Zhou, Guohua
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1802-1812
    • /
    • 2016
  • Cross regulation is a key technical issue of single-inductor multiple-output (SIMO) DC-DC converters. This paper investigates the cross regulation in single-inductor dual-output (SIDO) Buck converters with continuous conduction mode (CCM) operation. The expressions of the DC voltage gain, control to the output transfer function, cross regulation transfer function, cross coupled transfer function and impedance transfer function of the converter are presented by the time averaging equivalent circuit approach. A small signal model of a SIDO CCM Buck converter is built to analyze this cross regulation. The laws of cross regulation with respect to various load conditions are investigated. Simulation and experiment results verify the theoretical analysis. This study will be helpful for converter design to reduce the cross regulation. In addition, a control strategy to reduce cross regulation is performed.