• Title/Summary/Keyword: Voltage Source Inverter

Search Result 797, Processing Time 0.025 seconds

Common Model EMI Prediction in Motor Drive System for Electric Vehicle Application

  • Yang, Yong-Ming;Peng, He-Meng;Wang, Quan-Di
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.205-215
    • /
    • 2015
  • Common mode (CM) conducted interference are predicted and compared with experiments in a motor drive system of Electric vehicles in this study. The prediction model considers each part as an equivalent circuit model which is represented by lumped parameters and proposes the parameter extraction method. For the modeling of the inverter, a concentrated and equivalent method is used to process synthetically the CM interference source and the stray capacitance. For the parameter extraction in the power line model, a computation method that combines analytical method and finite element method is used. The modeling of the motor is based on measured date of the impedance and vector fitting technique. It is shown that the parasitic currents and interference voltage in the system can be simulated in the different parts of the prediction model in the conducted frequency range (150 kHz-30 MHz). Experiments have successfully confirmed that the approach is effective.

Compensation of the rotor time constant of induction motor using current error feedback (전류오차 궤환을 이용한 유도전동기 회전자 시정수 보상)

  • 김승민;이무영;권우현
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.195-198
    • /
    • 1997
  • This paper proposes the effective compensation method of the rotor time constant of induction motor. An indirect vector control method is highly dependent on the motor parameters. To solve the problem of performance degradation due to parameter variation in an indirect vector control of induction motor, we compensate the rotor time constant by current error feedback. The proposed method is a simple on-line rotor time constant compensation method using the information from terminal voltages and currents. As the current error, difference between current command and estimated current, approaches to zero, the value of rotor time constant in an indirect vector controller follows the real value of induction motor. This scheme is valid transient region as well as steady state region regardless of low or high speed. This method is verified by computer simulation. For this, we constructed the simulation model of induction motor, indirect vector controller and current regulated PWM (CRPWM) voltage source inverter (VSI) using SIMULINK in MATLAB.

  • PDF

Motor drive control development: a new approach to learning and design

  • Porobic, Vlado;Ivanovic, Zoran;Adzic, Evgenije;Vekic, Marko;Celanovic, Nikola;Oh, Hyounglok
    • Proceedings of the KIPE Conference
    • /
    • 2013.11a
    • /
    • pp.37-38
    • /
    • 2013
  • This paper presents an intuitive and powerful way to study and design motor drive control. The control of induction motors, as most widely used machines, is discussed. Thanks to ultra low latency and high fidelity Hardware-in-the-Loop systems, different aspects of up-to-date drive regulation are examined. A power stage, comprised of a grid voltage source, a rectifier, a VSC inverter and an induction motor, is emulated on the HIL platform in real time. A digital signal controller is plugged into the interface board and connected to the HIL emulation platform, without any hardware modifications. For motor control and power electronics applications, a dedicated Texas Instruments TMS320F2808 DSP is chosen. The same controller can drive an emulation platform and a real device with no modifications. Current and speed control loop test results are presented and discussed.

  • PDF

A Fuzzy Current Controller using General Purposed Fuzzy Control Software Tool (범용 퍼지 지원 도구를 이용한 퍼지 전류제어기)

  • Min, Seong-Sik;Lee, Kyu-Chan;Song, Jhong-Whan;Cho, Kyu-Bok
    • Proceedings of the KIEE Conference
    • /
    • 1991.11a
    • /
    • pp.341-344
    • /
    • 1991
  • Current controlled pulse width modulation(PWM) for voltage source inverter(VSI) is one of the control method which controls the current directly so that we can perform vector control because it reduces the orders of differential equations of the induction machine. This paper propose a Fuzzy current controlled PWM which properly minimize a current ripple using Fuzzy theory in a constant switching frequency. This technique is applied to an electrical drive system with an induction machine(IM) by simulation. By comparison with the known classical method such as ramp comparison, hysteresis band method, our contribution shows the better performances.

  • PDF

ANALYSIS of A VSI-FED INDUCTION MOTOR VECTOR CONTROL with MODEL TRACKING CONTROLLER (전압형 인버터 구동 유도전동기 벡터제어계의 모델추종제어의 해석)

  • Kim, Keun-Ha;Kim, Yong-Ju;Choe, Gyu-Ha;Kim, Han-Sung;Shin, Dae-Cheol;Yu, Gwon-Jong
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.347-351
    • /
    • 1990
  • In this paper voltage source inverter(VSI)-fed induction motor vector control system is controlled by a derived model tracking controller. The system analysis is discussed from the viewpoints of ideal vector control, adoption of model tracking controller and derivation of linear model. Furthermore, the result is obtained by the model-tracking control compare with that of P-I, I-P control.

  • PDF

The Control of Stand-Alone Induction Generator with Vector Control (벡터 제어 방식에 의한 자립형 유도 발전기의 제어기)

  • Kee, Tae-Hoon;Jeong, Seung-Gi;Park, Min-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.303-308
    • /
    • 1990
  • The stand alone induction generator has been excited by capacitor bank or voltage source inverters. The conventional excitation methods offer several restrictions on the operation of the induction generator in various operating conditions. To overcome the restrictions, this paper presents the induction generator system excited by the current controlled inverter which operates on the principle of vector control. The proposed control scheme is based on the rotor flux oriented indirect vector control. The steady state characteristics are investigated to yield control ranges under various operating conditions. Through the simulation, it is confirmed that the system has good dynamic characteristics wi thin the controllable ranges given by the steady state analysis.

  • PDF

A Implementation of PRT Current Control Algorithm for Current-Controlled Voltage Source Inverter (전류제어형 전압원 인버터용 PRT 전류제어알고리즘 구현)

  • Kwon, Hyuk-Dae;Park, Chun-Sung;Yoo, Won-Ho;Choi, Jae-Hyuk;Ko, Sung-Hun;Lee, Seong-Ryong
    • Proceedings of the KIEE Conference
    • /
    • 2008.04c
    • /
    • pp.146-148
    • /
    • 2008
  • 본 논문에서는 계통의 전력품질을 향상시키기 위해 사용되어지는 전류제어형 전압원 인버터를 구동하기 위한 PRT(Polarized RamTime) 전류제어알고리즘의 구현방법을 설명한다. PRT 전류제어알고리즘은 스위칭 시퀀스의 예측이 가능하고 히스테리시스 전류제어기법의 단점인 가변스위칭 주파수 문제를 해결할 수 있다. 본 연구에서는 전류제어형 전압원인버터용 PRT 전류제어알고리즘을 FPGA(Field Programmable Gate Array)를 이용하여 구현하였고, 이의 유용성을 확인하기 위해 1KVA급 계통연계 전류제어형 전압원 인버터에 적용하여 실험 하였다.

  • PDF

Hysteresis Current Control with Self-Locked Frequency Limiter for VSI Control (자기동조 주파수 제한기를 갖는 전압원 인버터의 히스테리시스 전류제어)

  • Choe, Yeon-Ho;Im, Seong-Un;Gwon, U-Hyeon
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.1
    • /
    • pp.23-33
    • /
    • 2002
  • A hysteresis control is widely used to control output current of inverter. A hysteresis bandwidth is affected by system parameters such as source voltage, device on/off time, load inductance and resistance. The frequency limiter is used to protect switching devices overload. In the conventional hysteresis controller, a lock-out circuit with D-latch and timer is used to device protection circuit. But switching delay time and harmonic components are appeared in output current. In this paper the performance of lock-out circuit is tested, and new circuit for switching device fault protection is proposed ad it's performance is simulated.

New Anti-windup PI Control for Variable-Speed Motor Drives (가변속 전동기구동을 위한 새로운 반포화 PI 제어기)

  • 신휘범;이정훈;정세교
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.357-363
    • /
    • 1997
  • The windup phenomenon appears and results in the performance degradation when the PI controller output is saturated. A new anti-windup PI controller is proposed to improve the control performance of the variable-speed motor drives and it is experimentally applied to the speed control of a vector-controlled induction motor driven by a pulse width modulated(PWM) voltage source inverter (VSI). The integral state is separately controlled corresponding to whether the PI controller output is saturated or not. The experimental results show that the speed response has the much improved performances such as small overshoot and fast settling time over the conventional anti-windup technique. Although the operating speed command is changed, the similar control performance can be obtained by using the PI gains selected in the linear region.

  • PDF

Modeling and Simulation Analysis of Grid-Connected Photovoltaic Generation System in terms of Dynamic behavior (계통연계형 태양광발전시스템의 동특성 모델링 및 모의해석)

  • Kim, Eung-Sang;Kim, Seul-Ki
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.127-131
    • /
    • 2005
  • The paper addresses modeling and analysis of a grid-connected photovoltaic generation system (PV system). PSCAD/EMIDC. an industry standard simulation tool for studying the transient behavior of electric power system and apparatus. is used to conduct all aspects of model implementation and to carry out extensive simulation study. An equivalent circuit model of a solar cell has been used for modeling solar array. A PWM voltage source inverter (VSI) and its current control scheme have been implemented. A maximum power point tracking (MPPT) technique is employed for drawing the maximum available energy from the PV array. Comprehensive simulation results are presented to examine PV array behaviors and PV system control performance in response to irradiation changes. In addition, dynamic responses of PV array and system to network fault conditions are simulated and analysed

  • PDF