• Title/Summary/Keyword: Voltage Quality

Search Result 1,548, Processing Time 0.035 seconds

The Concept and International Standards of Power Quality (전력 품질의 개념 정립과 국제 표준 비교)

  • Lim, Su-Saeng;Lee, Eun-Woong;Sohn, Hong-Kwan;Joh, Hyun-Kil;Jeong, Jong-Ho;Kim, Jun-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.174-177
    • /
    • 2001
  • The dependence of modern life upon the continuous supply of electrical energy makes system reliability and power quality topics of the utmost importance in the power systems. Power quality is the combination of voltage quality and current quality. But in this paper, voltage quality and harmonic distortion are focused. Transient phenomena and current quality are not included. Voltage quality is split into voltage sags. voltage swells, and short interruptions. These voltage variations are studied on their definitions, origins, the effect on electric equipment. Related industrial standards and guidelines are summarized. Harmonic voltage and current distortion are strongly linked. The concepts and contributions of harmonic distortions are studied. Typical symptoms of harmonic problems and a summary of the trends and guidelines are given.

  • PDF

An Investigation into the Impact on Voltage Sag due to Faults in Low Voltage Power Distribution Systems

  • Aggarwal R. K.
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.2
    • /
    • pp.97-102
    • /
    • 2005
  • Voltage sags are the most widespread quality issues affecting distribution systems. This paper describes in some detail the voltage sag characteristics due to different types and locations of fault in a practical low voltage power distribution system encountered in the UK. The results not only give utility engineers very useful information when identifying parts of the system most likely to pose problems for customer equipments, but also assist the facility personnel to make decisions on purchasing power quality mitigation equipment.

Power Quality Index and Cost based on Load-Voltage Characteristics (부하의 전압특성을 고려한 모선별 전력품질 지표 및 가격 산정기법)

  • 이근준
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.4
    • /
    • pp.213-218
    • /
    • 2003
  • In front of the opening of electric distribution market in 2004, it is indispensable to have a proper estimation of power quality index and rower quality cost calculation mechanism which are indispensable to stabilize highly industrialized society and to vitalize the Investment lot electric power system. However, there were not enough measures to reflect the voltage characteristics such as voltage sags and Interruptions which make electric load in unstable operation. This paper suggests power quality index and power quality cost which translate various kinds of voltage records into bus load drop index(BLDI) and bus power quality cost(BPQC) based on aggregated load CBEMA curve. A sample calculation result shows that this method can produces the acceptable power Quality index and costs for utilities and customers requirements.

Voltage Quality Analysis of Low Voltage Customer Connected to the Wind Generation System (풍력발전시스템에 연계된 저압수용가의 전압품질 분석)

  • Kim Moon Chan;Kim Hyun Jong;Kim Tae Ik;Yang Ik Jun;Na Kyoung Yun;Kim Se Ho
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.233-235
    • /
    • 2004
  • Operation of wind turbines has impacts on the voltage quantity at the connected electricity network. Increasing penetration of wind energy makes necessary to study the power quality regarding voltage variations(sag, swell, interruption) and presence of harmonics in the id. This paper investigates the voltage quality of low voltage customers connected to wind generation system. To study the influences of wind power generation to low voltage power system, voltage data are collected in three house using PQM(Power Quality Monitoring) equipment during one month and analyzed regarding voltage variation and harmonics

  • PDF

Connected Characteristics for Small Generation Source of Low Voltage Model Grids (저압 모의선로에 소형발전원 연계시 특성)

  • Lee, Sang-Woo;Kang, Jin-Kyu;Lee, Dong-Ha;Park, Tae-Joon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.2
    • /
    • pp.45-53
    • /
    • 2013
  • In this paper, we analyze the typical phase voltage and line current waveform characteristics of the distribution system with 3 phase small synchronous generation source in case with load and non-load group, in order to investigate the power quality for end load connected of generation source. As demonstrated by our experimental results, the distortion and power quality of phase voltage and line current waveform were relatively good for low voltage 3 phase model grids connected of 3 phase small synchronous generation source in case with non-load group. However, distortion and power quality of voltage and current waveform was poor for low voltage 3 phase model grids connected to 3 phase small synchronous generation source in the load group with some phase voltage and frequency difference. From the above results, we conclude that the phase voltage and frequency of 3 phase generation source must be identical to that of distribution system source to maximize the power quality. Also, special attention is required in case of having load group or non-load group to 3 phase generation source.

A Study on the Characteristic of Capacitor Current by Voltage Harmonics (전압 고조파에 의한 커패시터 전류 특성 해석)

  • Kim, Jong-Gyeum;Kim, Sung-Hyun;Kim, Il-Jung
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.2
    • /
    • pp.148-153
    • /
    • 2009
  • As the increasing of non-linear load, we have a growing interest in power quality. Power quality has come to the voltage quality. Voltage harmonics consist in at the PCC by the non-linear load. Capacitor is generally used for the power compensation and as the passive filter by the serial connection with reactor. Capacitor has low impedance as the frequency increases, so easily fall down by the harmonic component of non-linear load. Small voltage of low-order acts on quite a few at the capacitor by the current increase. In this paper, we measured the magnitude and angle of voltage at the PCC and calculated under the same condition. we checked out that lower voltage of higher order produces current magnification.

Design of a Series Voltage Sag Compensation System in Transmission Line

  • Park, Hyen-Young;Kim, Yang-Mo;Lee, Gyo-Sung;Oh, Se-Ho;Park, Jung-Gyun
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.2B no.4
    • /
    • pp.191-200
    • /
    • 2002
  • When power consumption increases, power supply must be efficient and reliable for good power quality. The studies on compensation system of power quality are processing actively. Voltage sag among of factors for power quality is generally PI dual control that voltage sag compensation is used. But this control is no more available since of 120[KHz] ripple rejection. So we proposed the control algorithm using PID control in 3-phase unbalanced power system and the series voltage compensator, when voltage sag occurs.

Phase Shift Control for Series Active Voltage Quality Regulators

  • Xiao, Guochun;Teng, Guofei;Chen, Beihai;Zhang, Jixu
    • Journal of Power Electronics
    • /
    • v.12 no.4
    • /
    • pp.664-676
    • /
    • 2012
  • A phase shift algorithm based on the closed-loop control of dc-link voltage implemented on a series active voltage quality regulator (AVQR) is proposed in this paper. To avoid pumping-up the dc-link voltage, a general phase shift compensation strategy is applied. The relationships among the operation variables are discussed in detail, which is very important for guiding the design of both the main circuit and the control system. Then on the basis of an investigation of the dc-link voltage pumping-up from viewpoint of the active power flow, a novel phase shift control method based on the closed-loop of the dc-link voltage is proposed. This method can adjust the phase of the output voltage gradually and automatically according to the dc-link voltage variation without introducing a phase jump. The effectiveness of the proposed strategy is verified through simulations of a single-phase 5kVA prototype and laboratory experiments on both a single-phase 5kVA and a three-phase 15kVA prototype.

The Detection of Voltage Sag using Wavelet Transform (웨이브렛 변환을 이용한 Voltage Sag 검출)

  • Kim, Cheol-Hwan;Go, Yeong-Hun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.9
    • /
    • pp.425-432
    • /
    • 2000
  • Wavelet transform is a new method fro electric power quality analysis. Several types of mother wavelets are compared using voltage sag data. Investigations on the use of some mother wavelets, namely Daubechies, Symlets, Coiflets, Biorthogonal, are carried out. On the basis of extensive investigations, optimal mother wavelets for the detection of voltage sag are chosen. The recommended mother wavelet is 'Daubechies 4(db4)' wavelet. 'db4', the most commonly applied mother wavelet in the power quality analysis, can be used most properly in disturbance phenomena which occurs rapidly for a short time. This paper presents a discrete wavelet transform approach for determining the beginning time and end time of voltage sags. The technique is based on utilising the maximum value of d1(at scale 1) coefficients in multiresolution analysis(MRA) based on the discrete wavelet transform. The procedure is fully described, and the results are compared with other methods for determining voltage sag duration, such as the RMS voltage and STFT(Short-Time Fourier Transform) methods. As a result, the voltage sag detection using wavelet transform appears to be a reliable method for detecting and measuring voltage sags in power quality disturbance analysis.

  • PDF

The study on the characteristics of operating limit of low voltage electric machine under the effects of voltage quality (순간전압품질이 저압 전기기기 운전한계에 미치는 특성연구)

  • Park, In-Deok;Jeong, Sung-Won;Gim, Jae-Hyeon;Lee, Geun-Joon
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.95-97
    • /
    • 2007
  • This paper studies on operating limit curve of low voltage electric machinery with respect to source voltage variation or sag. Also, it discusses electric machine and compensation equipment design methodology based on voltage quality effect assessment technology. Voltage quality standards, such as SEMI47, CBEMA, ITIC curve are regarded to examine the relation between time constants of load and sagging time of sag generator, the load(low voltage electric machinery) study. Voltage sag characteristics of loads, time constant and sag relation voltage-time operating limits are tested and verified.

  • PDF