• 제목/요약/키워드: Voltage Patterns

검색결과 348건 처리시간 0.022초

A Cascaded Multilevel Inverter Using Bidirectional H-bridge Modules

  • Kang, Feel-Soon;Joung, Yeun-Ho
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권4호
    • /
    • pp.448-456
    • /
    • 2012
  • This paper presents a multilevel inverter configuration which is designed by insertion of a bidirectional switch between capacitive voltage sources and a conventional H-bridge module. The modified inverter can produce a better sinusoidal waveform by increasing the number of output voltage levels. By serial connection of two modified H-bridge modules, it is possible to produce 9 output voltage levels including zero. There are 24 basic switching patterns with the 9 output voltage levels. Among the patterns, we select the 2 most efficient switching patterns to get a lower switching loss and minimum dv/dt stress. We then analyze characteristics of Total Harmonic Distortion (THD) of the output voltage with variation of input voltage by computer-aided simulations and experiments.

Design Parameter Optimization for Hall Sensor Application

  • Park, Chang-Sung;Cha, Gi-Ho;Kang, Hyun-Soon;Song, Chang-Sup
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.86.3-86
    • /
    • 2001
  • Hall effect sensor using 7um, 1.7 ohm-cm or 10um, 3.5 ohm-cm Bipolar process was successfully developed. The Hall sensor consists of various patterns, such as regular shapes, rectangles, diamond, hexagon and cross shapes to optimize offset voltage and sensitivity for proper applications. In order to measure offset voltage in chip scale the Agilent company´s 4156C and Nano-Voltage Meter were used and the best structure in offset voltage was finally selected by using ceramic package. The patterns appear to be the quadri-rectangular patterns entirely and three-parallelogram patterns. The measured offset voltages were found to be about 173-365uV. Meanwhile, in ...

  • PDF

교류초퍼에서 단락사고 방지를 위한 스위칭 신호 패턴 (Switching Signal Patterns to Prevent Short Circuit of AC Choppers)

  • 장도현;연재을
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권9호
    • /
    • pp.445-452
    • /
    • 2001
  • Two switching signal patterns are proposed to prevent short circuit of PWM ac choppers. The voltage detection method and the current detection method are proposed to execute two switching signal patterns. In the voltage detection method, the dead-time has to be inserted to the switching signals after polarity of input voltage is checked by voltage transducer at input side. In the current detection method, the direction of load current is checked by current transducer at output side, and the dead-time delay is not considered. Controlling circuit built by current detection method is simple because the dead-time delay is considered. The experimental results are presented to prevent short circuit of ac chopper safely.

  • PDF

레이저 마스킹과 직류전원을 이용한 선택적 전해도금 (Selective Electrodeposition Using Laser Masking and DC Voltage)

  • 신홍식;김성룡
    • 한국생산제조학회지
    • /
    • 제24권1호
    • /
    • pp.75-80
    • /
    • 2015
  • This paper proposes a selective electrodeposition process that uses laser masking and a DC voltage. Selective electrodeposition using laser masking and a DC voltage is more efficient than that using laser masking and a pulse voltage. In other words, electrodeposition with a DC voltage allows for precise selective deposition without the limitation of the deposition region. Also, a selective electrodeposition method that uses laser masking and DC voltage can reduce the electrodeposition time. The characteristics of a copper layer deposited by laser masking and DC voltage were examined under various conditions. A selective copper layer with various micro patterns of $2{\mu}m$ thickness was successfully fabricated.

An Algorithm for Applying Multiple Currents Using Voltage Sources in Electrical Impedance Tomography

  • Choi, Myoung-Hwan;Kao, Tzu-Jen;Isaacson, David;Saulnier, Gary J.;Newell, Jonathan C.
    • International Journal of Control, Automation, and Systems
    • /
    • 제6권4호
    • /
    • pp.613-619
    • /
    • 2008
  • A method to produce a desired current pattern in a multiple-source EIT system using voltage sources is presented. Application of current patterns to a body is known to be superior to the application of voltage patterns in terms of high spatial frequency noise suppression, resulting in high accuracy in conductivity and permittivity images. Since current sources are difficult and expensive to build, the use of voltage sources to apply the current pattern is desirable. An iterative algorithm presented in this paper generates the necessary voltage pattern that will produce the desired current pattern. The convergence of the algorithm is shown under the condition that the estimation error of the linear mapping matrix from voltage to current is small. Simulation results are presented to illustrate the convergence of the output current.

부극성 직류전압에 의해 형성된 공간전하가 XLPE의 부분방전패턴에 미치는 영향 (Effects of Pre-Formed Space Charge by Negative DC Voltage on Partial Discharge Patterns of XLPE)

  • 황보승;이준호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1653-1655
    • /
    • 2003
  • The purpose of this paper is to evaluate the effects of pre-formed space charge by negative DC voltage on partial discharge(PD) patterns of XLPE. We have suggested a modified pulsed electro-acoustic method and demonstrated that the PD patterns are strongly influenced by the pre-formed space charge distributions, which are hardly disappeared up to AC 8kV in electrode configuration including air gap between XLPE layer and electrode.

  • PDF

부분방전을 이용한 초고압 지중 송전 절연 케이블 내부 결함의 패턴분석 (Pattern Analysis of the Defects within the Cable Insulation for UHV Underground Transmission Using Partial Discharge)

  • 박재화;이광열;채석;오영석;김학성
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.175-179
    • /
    • 1998
  • The insulation of cable which used for Ultra-High Voltage(UHV) underground power transmission requires excellent insulation capability for high voltage. The typical insulation materials are used XLPE, EPR, etc, but insulation efficiency of these is affected by void or alien substances, existed at the inside of insulators. In this paper, the partial discharge patterns of the defects within insulation cable are observed and analyzed. In this test, void, fiber and metal inclusions which possibly exist in cables, are simulated and investigated the patterns of partial discharges for each models Also the relations between calculated field strength and the insulation breakdown voltage. The experiment shows distinct partial discharge patterns in accordance with the kinds of defects within Insulation cable.

  • PDF

3상 매트릭스 컨버터에 사용되는 옵셋전압 PWM 방법과 $V_{max}-V_{mid}$ PWM 방법의 비교분석 (Comparative Analysis of Offset Voltage PWM and $V_{max}-V_{mid}$ PWM Method for 3 Phase Matrix Converter)

  • 차한주;김우중
    • 전기학회논문지
    • /
    • 제58권2호
    • /
    • pp.285-291
    • /
    • 2009
  • In this paper, comparative analysis of offset voltage PWM method and $V_{max}-V_{mid}$ PWM method for three-phase matrix converter is addressed by using a simple analytical and graphical method. Offset voltage PWM method calculates PWM patterns in terms of offset voltage and variable slope of carrier, and it simplifies matrix converter modulation algorithm significantly. $V_{max}-V_{mid}$ PWM method generates patterns by using two phases and maintaining a remaining phase to base phase, and it is implemented in the industrial products. The most important performance criterion of modulation method is a magnitude of current ripples and it is analytically modelled. The graphical illustration of theses complex multivariable functions make per-carrier cycle and per fundamental cycle behavior of two PWM methods understood. Two modulation methods are analysed with the analytical formulas and graphics, and the analysis shows offset voltage PWM method is superior to $V_{max}-V_{mid}$ PWM method with respect to input current ripples and output voltage ripples.

XLPE에서 공간전하가 PD 패턴에 미치는 영향 (Effect of Space Charge on the PD Pattern in XLPE)

  • 황보승;심재위;이진종;이동영;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.96-100
    • /
    • 2001
  • We have measured the space charge distribution and PD patterns simultaneously in XLPE under AC voltages by modified PEA method in order to investigate the effect of space charge on PD patterns in XLPE with air-gap. From the experimental results, we found that the dynamic space charge accumulated on the surface of XLPE due to the PD dominantly affects the PD pattern in the dielectric-barrier structure and governs the voltage across the air-gap. Moreover, the space charge formed by applying DC voltage still remained after applying AC voltage, which means that the space charge formed during DC strength test is likely to be fatal to the long-time AC insulating characteristics of HV equipments. On the other hand, the PD patterns was much influenced by the pre-formed space charge by DC application. Therefore, it is possible to detect the effects of space charge by monitoring the infinitesimal change of PD patterns before and after DC strength.

  • PDF

The Characteristics of Electrocardiography Findings in Left Ventricular Remodeling Patterns of Hypertensive Patients

  • Choi, Sun Young
    • 대한의생명과학회지
    • /
    • 제21권4호
    • /
    • pp.208-217
    • /
    • 2015
  • The exact diagnosis of left ventricular hypertrophy (LVH) is very important in the treatment of hypertension. The purpose of our study is to determine the relationship between left ventricular remodeling patterns and electrocardiography (ECG) findings in hypertensive patients. We divided 137 patients into four groups according to left ventricular mass index (LVMI) and the relative wall thickness: normal, concentric remodeling, concentric hypertrophy, eccentric hypertrophy. LVH on the ECG was defined by three ECG criteria: Sokolow-Lyon voltage criteria, Cornell voltage criteria and Romhilt-Estes point score. LVH on the echocardiography was defined by LVMI. The prevalence of ECG LVH was increased in concentric hypertrophy and eccentric hypertrophy group. The QRS voltages by Sokolow-Lyon voltage criteria (r = 0.494, P = 0.002) and Cornell voltage criteria (r = 0.628, P < 0.001), and Romhilt-Estes point score (r = 0.689, P < 0.001) were positively correlated with LVMI. Also, the QRS voltages and point scores were significantly increased in the concentric hypertrophy and eccentric hypertrophy group with increased LVMI. The QRS voltage and Romhilt-Estes point scores were positively correlated with LVMI. The QRS voltages and Romhilt-Estes point scores were also increased in the left ventricular remodeling groups with increased LVMI.