• Title/Summary/Keyword: Voltage Detector

Search Result 508, Processing Time 0.026 seconds

Assessment of Insulation Condition in High Voltage Motor Stator Windings (고압전동기 고정자 권선의 절연상태 평가)

  • Kim, Hee-Dong;Park, Eui-Gab;Park, Wan-Jo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2392-2395
    • /
    • 1999
  • This paper describes to access the insulation deterioration condition of the stator windings in six high voltage motors. Nondestructive tests have been carried out on stand-still motors. These tests include ac current increase rate($\Delta$I), delta tan delta(${\Delta}tan{\delta}$), and maximum partial discharge(PD). AC current and $tan{\delta}$ were measured by Schering bridge. The measurement of PD patterns were conducted using digital partial discharge detector. PD patterns were observed treeing and internal discharges in Motor 1 and 2. The stator windings of two motors were found to be in a poor condition and their were recommended to rewind. The stator. windings of four motors were judged to be in serviceable condition.

  • PDF

Partial Discharge Properties of High Voltage Motor Stator Insulation using Partial Discharge Analyzer (PDA를 이용한 고압전동기 고정자 권선에서 부분방전 특성)

  • Kim, Hee-Dong;Lee, Sang-Kil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.225-228
    • /
    • 2001
  • Partial discharge(PD) testing for different capacitive couplers was performed on a 6.6kV, 448kW pulverizer motor. The motor has been in service for twenty years. PD tests were measured using digital partial discharge detector(DPDD) and partial discharge analyzer(PDA), respectively. PDA is used to in the motor stator insulation, which three 80pF or three 500pF epoxy-mica couplers were installed, one per phase. The 500pF couplers did detect more normalized quantity number(NQN) than the 80pF couplers. DPDD and PDA showed that PD and NQN magnitudes increased with increase of ac voltage. Internal discharge was discovered in the motor stator insulation. DPDD and PDA test results are in accordance with the pattern and magnitude of PD.

  • PDF

Control Characteristics of Three-Phase Utility Interactive Phovotovoltaic Power Generation System (3상 계통연계 태양광발전시스템의 운전특성)

  • Kim, Yeong-Cheol;Jeong, Myeong-Ung;Seo, Gi-Yeong;Lee, Hyeon-U;U, Jun-In
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.8
    • /
    • pp.536-543
    • /
    • 2000
  • The photovoltaic power generation system has a great future as clean energy instead of fossil fuel which has many environmental problems such as exhausted gas or air pollution. In a utility interactive photovoltaic generation system, a three-phase inverter is used for the connection between the photovoltaic array and the utility. This paper present a three phase inverter for photovoltaic power system with current controller, voltage controller, PLL Control system and the Phase detector of Interactive Voltage by using dq transformation. The proposed inverter system provides a sinusoidal ac current for domestic loads and the utility line with unity power factor.

  • PDF

The Construction and Operating Characteristics analysis of Utility interactive PV power generation system (계통연계형 태양광 발전시스템의 운전특성 해석과 문제점 분석)

  • Hong, D.S.;Koh, K.H.;Koh, H.S.;Lee, H.W.
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.334-336
    • /
    • 2001
  • The photovoltaic power generation system has a great future as clean energy instead of fossil fuel which has many environmental problems such as exhausted gas or air pollution. In a utility interactive photovoltaic generation system, a three-phase inverter is used for the connection between the photovoltaic array and the utility. This paper presents a three phase inverter for photovoltaic power system with current controller, voltage controller PLL control system and the phase detector of interactive voltage by using do transformation. The proposed inverter system provides a sinusoidal are current for domestic loads and the utility line with unity power factor. The results of the operated from January to October show the system characteristics.

  • PDF

A Phase Detection Method For Line Lock (전원동기를 위한 위상검출방법)

  • Kim, Young-Choon;Lee, Sa-Young
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.428-430
    • /
    • 2007
  • Converter that is dc source equipment source's phase by reference control function that detect source's phase because should be done compulsorily use. Source's phase detect method there be method that use source's ac voltage directly by signal, and use methods that voltage detects status by PLL method and so on via point that '0' becomes usually. All above methods to detect phase are using, wrong action of phase detector converter's ailment or converter of burn can. Ths paper compares and examined usable phase detection method in source's frequency fluctuation presuming source's frequency using observer.

  • PDF

Partial Discharge Property of Hydrogenerator Stator Windings (수력발전기 고정자 권선에서 부분방전 특성)

  • Kim, Hee-Dong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.86-90
    • /
    • 2000
  • Partial discharge(PD) tests were performed when the hydrogenerator(rated 11kV and 25MVA) was shut down(off-line). Six cable couplers were installed in the ring bus as well as within hydrogenerator terminal box. PD tests were conducted using partial discharge analyzer(PDA) and digital partial discharge detector(PDD). PDA showed that the normalized quantity number(NQN) and the partial discharge magnitude increased with increase of ac voltage. Slot discharges were discovered in three phases(A, B and C) at the rated voltage. PDA and PDD test results are in accordance with the pattern and magnitude of partial discharge. This hydrogenerator stator windings were in good condition.

  • PDF

Analysis of Partial Discharge in High Voltage Motor Model Coils (고압전동기 모델 코일의 부분방전 분석)

  • Kim, Hee-Dong;Kong, Tae-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2091-2093
    • /
    • 2005
  • Five model coils of 6.6kV motor were manufactured with several defects. These stator coils have artificial defects such as void of groundwall insulation, removal of semi-conductive coating and damage of strand insulation. Epoxy-mica coupler(80 pF) was connected to five model coil terminals, respectively The voltage applied to the coils was 3.81kV, 4.76kV, 6.0kV and 6.6kV. Partial discharge(PD) tests performed in the laboratory and shield room. Digital PD detector (PDD) and turbine generator analyzer(TGA) were used to measure PD activity. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). The PD levels in pC were measured with PDD. PD patterns of model coils were indicated the internal and slot discharges. PD patterns coincide with both PDD and TGA.

  • PDF

A filed operation characteristics and the controversial point of Photovoltaic power generation system (태양광 발전시스템의 현장 운전특성 및 문제점)

  • Koh, Kang-Hoon;Suh, Ki-Young;Lee, Hyun-Woo;Hong, Doo-Sung;Gang, Yeong-Cheol;U, Jung-In
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.381-383
    • /
    • 2000
  • The photovoltaic power generation system has a great future as clean energy instead of fossil fuel which has many environmental problems such as exhausted gas or air pollution. In a utility interactive photovoltaic generation system, a three-phase inverter is used for the connection between the photovoltaic array and the utility. This paper presents a three phase inverter for photovoltaic power system with current controller, voltage controller, PLL control system and the phase detector of interactive voltage by using da transformation. The proposed inverter system provides a sinusoidal ac current for domestic loads and the utility line with unity power factor. The results of the operated from January to October show the system characteristics.

  • PDF

Response Characteristics of Charged Particle Type Display (대전입자형 디스플레이의 응답특성)

  • Lee, Dong-Jin;Kim, Young-Cho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.2
    • /
    • pp.169-173
    • /
    • 2009
  • We studied driving characteristics according to the ratio of mass and charging (m/q) value for charged toner particles with black and yellow color in charged particle type display panel. After biasing rectangle pulse to the transparency electrodes of putted panel with toner particles, its response time and contrast ratio are simultaneously measured using a laser as a optical source, photodiode as a detector and reflective system. As a results, contrast ratio is largest at the shortest response time region which is different to the particle because of m/q. We proposed relational equation for response time, m/q, cell gap and biasing voltage. It has not been studied and reported to analyze the relationship of response time, biasing voltage, lumping phenomena, cell gap, and contrast ratio for toner particle type display.

Integrated Circuit of a Peak Detector for Flyback Converter using a 0.35 um CMOS Process (0.35 um CMOS 공정을 이용한 플라이백 컨버터용 피크검출기의 집적회로 설계)

  • Han, Ye-Ji;Song, Han-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.42-48
    • /
    • 2016
  • In this paper, a high-precision peak detector circuit that detects the output voltage information of a fly-back converter is proposed. The proposed design consists of basic analog elements with only one operational amplifier and three transistors. Because of its simple structure, the proposed circuit can minimize the delay time of the detection process, which has a strong impact on the precision of the regulation aspect of the fly-back converter. Furthermore, by using an amplifier and several transistors, the proposed detector can be fully integrated on-chip, instead of using discrete circuit elements, such as capacitors and diodes, as in conventional designs, which reduces the production cost of the fly-back converter module. In order to verify the performance of the proposed scheme, the peak detector was simulated and implemented by using a 0.35 m MagnaChip process. The gained results from the simulation with a sinusoidal stimulus signal show a very small detection error in the range of 0.3~3.1%, which is much lower than other reported detecting circuits. The measured results from the fabricated chip confirm the simulation results. As a result, the proposed peak detector is recommended for designs of high-performance fly-back converters in order to improve the poor regulation aspect seen in conventional designs.