• Title/Summary/Keyword: Voc

Search Result 1,275, Processing Time 0.03 seconds

Optimized ultra-thin tunnel oxide layer characteristics by PECVD using N2O plasma growth for high efficiency n-type Si solar cell

  • Jeon, Minhan;Kang, Jiyoon;Oh, Donghyun;Shim, Gyeongbae;Kim, Shangho;Balaji, Nagarajan;Park, Cheolmin;Song, Jinsoo;Yi, Junsin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.308-309
    • /
    • 2016
  • Reducing surface recombination is a critical factor for high efficiency silicon solar cells. The passivation process is for reducing dangling bonds which are carrier. Tunnel oxide layer is one of main issues to achieve a good passivation between silicon wafer and emitter layer. Many research use wet-chemical oxidation or thermally grown which the highest conversion efficiencies have been reported so far. In this study, we deposit ultra-thin tunnel oxide layer by PECVD (Plasma Enhanced Chemical Vapor Deposition) using $N_2O$ plasma. Both side deposit tunnel oxide layer in different RF-power and phosphorus doped a-Si:H layer. After deposit, samples are annealed at $850^{\circ}C$ for 1 hour in $N_2$ gas atmosphere. After annealing, samples are measured lifetime and implied Voc (iVoc) by QSSPC (Quasi-Steady-State Photo Conductance). After measure, samples are annealed at $400^{\circ}C$ for 30 minute in $Ar/H_2$ gas atmosphere and then measure again lifetime and implied VOC. The lifetime is increase after all process also implied VOC. The highest results are lifetime $762{\mu}s$, implied Voc 733 mV at RF-power 200 W. The results of C-V measurement shows that Dit is increase when RF-power increase. Using this optimized tunnel oxide layer is attributed to increase iVoc. As a consequence, the cell efficiency is increased such as tunnel mechanism based solar cell application.

  • PDF

Characterization of Volatile Organic Compounds(VOCs) Concentrations in Jinju (진주시 대기중 휘발성 유기화합물의 농도특성 기초조사)

  • Park, Jeong-Ho;Park, Hyung-Gun;Suh, Jeong-Min
    • Journal of Environmental Science International
    • /
    • v.22 no.1
    • /
    • pp.91-98
    • /
    • 2013
  • In order to study the seasonal patterns and possible origins of air concentrations of volatile organic compounds(VOC), measurements were taken with GC-MS at 3 sampling sites in Jinju for 12 months from Mar. 2010 to Feb. 2011. Atmospheric VOC are sampled on tubes containing solid adsorbents(Tenax TA) with a time resolution of 2hrs. Composition and concentration of VOC are analysed with a GC system equipped with thermal desorption apparatus(ATD). The most abundant compound appeared to be Toluene, Ethylbenzene and m,p-Xylene. The mean concentrations of Benzene were 0.20 ppb at GN site, 0.18 ppb at DA site, and 0.25 ppb at SP site, respectively. VOC concentration showed a strong seasonal variation, with higher concentrations during the spring and lower concentrations during the summer. The results showed that monthly fluctuations in measured VOC concentrations depended on variations in the strength of sources, as well as on photochemical activity and meteorological conditions. In Jinju, the total VOC emissions for 2009 were estimated to be 4,407 ton/year by Clean Air Policy Support System(CAPSS). It is shown that solvent use 57.5%(2,534 ton/yr), waste treatment and disposal 23.3%(1,025 ton/yr), and mobil source-road traffic 12.2%(537 ton/yr) are the most significant anthropogenic source.

The Change Rate of Fuel Consumption for Different IRI of Paved Roads (포장도로의 거칠기 변화에 대한 차량 연료소모량 변화율)

  • Ko, Kwang-H.
    • International Journal of Highway Engineering
    • /
    • v.12 no.1
    • /
    • pp.55-59
    • /
    • 2010
  • High VOC(Vehicle Operating Cost) is the main reason for the rehabilitation of paved road and VOC is composed of fuel consumption, lubricant oil consumption, parts consumption, etc. Fuel consumption is one of the largest components of VOC and the roughness of road represents the deterioration level of the road. For these reasons, the fuel consumption is measured for different IRI(International Roughness Index) in this study. The fuel consumption was measured by processing the voltage signal of fuel injector of vehicle and the speed was measured with GPS. The change rate of fuel consumption for different IRI can be calculated with the results of this test. It's concluded that fuel consumption(L/100km) of medium and large passenger car increases 7 times fast of the increase of IRI(m/km) around 3.5m/km in the speed range of 40 ~ 100km/h, and fuel consumption is the best at 60km/h.

Characterization of Air Quality in Various Types of Indoor Environments in Urban Areas - Focusing on Homes, Offices, and Restaurants - (도시지역 실내환경 유형별 공기질 특성 평가 -가정, 사무실 및 식당을 중심으로-)

  • 백성옥;김윤신
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.4
    • /
    • pp.343-360
    • /
    • 1998
  • In this study, comprehensive air quality monitoring was undertaken with a variety of objectives to collect data on the levels of various indoor and ambient air quality parameters in the urban areas of Seoul and Taegu. The sampling sites were comprised of six offices, six residences and six restaurants in each city. The ambient air adjacent to the indoor sites was also simultaneously sampled for the same constituents. The sampling was conducted in two phases: summer of 1994 and winter of 1994/95. A range of air quality parameters were measured simultaneously, which include RSP, CO, COB, NOB, a range of VOC, airborne microbials, temperature, and relative humidity. The indoor and ambient levels of the pollutants measured in this study varied widely between the three types of environments studied. Comparison of median values for the three groups revealed that restaurants had higher indoor levels of most pollutants than homes or offices. There was also a clear pattern of the indoor levels of target pollutants being higher than those outdoors, particularly in restaurants. Concentrations of CO and most of the VOC were found to be significantly higher in the commercial districts, indicating the influence of vehicle exhaust emissions. A very wide range of VOC levels was documented in this study. Although median indoorloutdoor ratios indicated a generally increasing level of VOC indoors when compared to those outdoors, no statistically significant differences were found between indoor and outdoor VOC levels in homes and offices, implying the importance of ambient air quality in determining the quality of indoor air for homes and offices in urban areas. In addition, there was a general pattern of increasing concentrations from summer to winter, and similarly from outdoor to indoor air for nearly all target compounds. The seasonal differences in median levels were very clearly seen for fuel combustion related pollutants such as RSP, CO and VOC, this being attributed to the effects of increased fuel consumption during the cold season and to meteorological factors.

  • PDF

Analysis of Higher Temporal Moments for Breakthrough Curves of Volatile Organic Compounds in Unsaturated Soil (불포화 토양에서 유동하는 가스상 Volatile Organic Compounds의 출현곡선에 대한 고차 Temporal Moment의 분석)

  • Kim, Heon-Ki
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.6
    • /
    • pp.60-69
    • /
    • 2007
  • Understanding the behavior of gas phase VOCs (volatile organic compounds) in unsaturated soils is of a great environmental importance for public health concerns. Moment analysis for the breakthrough curves (BTCs) during transport of chemicals in porous media was known to be a useful tool to evaluate the velocity, spreadness, and the skewness of the plume of the chemicals. In this study, the temporal moments of the BTCs of a group of VOCs were analyzed for the gaseous transport in an unsaturated soil. BTCs were measured using lab-scale column experiments for four different VOCs at the water saturation range of 0.04-0.46, and for eleven VOCs at a water saturation of 0.21. The central second and third moments of the VOCs were compared with the water saturation and the first moment. It was found that both central second and third moments increased with the first moment. The central third moment was, however, found to be more sensitive to the first moment.

VOC 제거를 위한 상압플라즈마 발생장치 개발

  • Choe, Seong-Chang
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.553-553
    • /
    • 2013
  • 상압 플라즈마 기술은 표면처리, 온존 발생장치, VOC (Volatile Organic compound) 제거등 다양한 산업분야에서 응용되고 있다. 상압플라즈마 기술 또한 DBD (Dielectric barrier discharge), Griding Arc, SDIP (Surface Discharge Induced Plasma) 등 다양한 기술들이 개발되어져 왔다. VOC를 제거하기 위한 다양한 플라즈마 기술중 특히 BDB 방법과 SDIP 기술들은 플라즈마에 의한 VOC 분해 뿐만 아니라 오존 발생을 통하여 VOC성분을 분해하는 것으로 알려져 있으며 효율이 매우 뛰어난 것으로 보고 되고 있다. 그러나 BDB 방전의 경우 방전이 발생하는 간격이 매우 작아 공기를 정화시키기 위해 좁은 유로를 통하여 일정넓이를 이동하여하 하기 때문에 압력감소가 심하며 이를 개선하기위해 다단으로 설계할 경우 구조가 복잡하고 가격이 고가인 단점이 있다. 본 연구에서는 두 개의 면 전극이 마주보는 형태로 된 DBD 구조의 단점을 보완하기 위하여 빗살무늬 모양의 다층구조의 선형전극으로 구조를 변화시켜 전극에 의한 압력감소를 방지하고 효율적으로 플라즈마 및 오존을 발생시킬 수 있는 VOC제거용 상압 플라즈마 발생장치를 개발하였다. 또한 플라즈마 발생 및 오존발생량이 우수한 것으로 알려져 있는 SDIP 장치 또한 제작하여 비교 평가를 하였다. 제작된 플라즈마 발생장치는 60 Hz와 20kHz의 교류 고압파워 서플라이를 이용하여 플라즈마 발생실험을 진행하였다. 선행 연구에서는 60 Hz의 고압 파워 서플라이를 이용하여도 플라즈마 방전이 잘 된다고 보고되었는데 본 실험에서 60 Hz 파워 서플라이를 사용할 경우 15 kV 이상이 인가될 때 아주 약하게 오존이 발생하는 현상이 관찰되었으나 육안으로 구분이 될 만큼의 플라즈마 방전은 발생하지 않았다. 20kHz의 고압파워 서플라이를 사용한 경우에는 비교적 낮은 전압인 7 kV에서 방전이 관찰되었으며 분당 22 mg의 오존이 발생하였다. SDIP를 이용한 경우 플라즈마가 발생하는 조건은 SDIP의 기하학적 형상에 많이 의존하게 된다. 본 실험에 SDIP 장치는 매우 낮은 전압에서 방전을 시작하였다. 기존의 DBD와는 다르게 1.7 kV에서 플라즈마 발생하였으며 1.8 kV에서 정상적인 플라즈마 방전이 발생하였다. 이때 분당 3.1 mg의 오존이 발생하였다. 오존 발생양은 앞에 빗살형 플라즈마 방전장치에 비하여 낮은데 인가되는 전력을 고려하면 입력된 전기 에너지당 오존발생양은 비슷한 수준이였다.

  • PDF

Estimating Ozone Sensitivity Coefficients to NOx and VOC Emissions Using BFM and HDDM for A 2007 June Episode (HDDM과 BFM을 이용한 NOx와 VOC 배출량에 대한 오존민감도계수 산정 및 결과 비교: 2007년 6월 수도권 사례)

  • Kim, Soon-Tae
    • Journal of Environmental Science International
    • /
    • v.20 no.11
    • /
    • pp.1465-1481
    • /
    • 2011
  • The accuracy of ozone sensitivity coefficients estimated with HDDM (High-order Decoupled Direct Method) can vary depending on the $NO_x$ (Nitrogen Oxides) and VOC (Volatile Organic Compound) conditions. In order to evaluate the applicability of HDDM over the Seoul Metropolitan Area (SMA) during a high ozone episode in 2007 June, we compare BFM (Brute Force Method) and HDDM in terms of the $1^{st}$-order ozone sensitivity coefficient to explain ozone change in response to changes in NOx and VOC emissions, and the $2^{nd}$-order ozone sensitivity coefficient to represent nonlinear response of ozone to the emission changes. BFM and HDDM estimate comparable ozone sensitivity coefficients, exhibiting similar spatial and temporal variations over the SMAduring the episode. NME (Normalized Mean Error) between BFM and HDDM for the episode average $1^{st}$- and $2^{nd}$-order ozone sensitivity coefficients to NOx and VOC emissions are less than 3% and 9%, respectively. For the daily comparison, NME for the $1^{st}$- and $2^{nd}$-order ozone sensitivity coefficients are less than 4% ($R^2$ > 0.96) and 15% ($R^2$ > 0.90), respectively. Under the emission conditions used in this study, two methods show negative episode average $1^{st}$-order ozone sensitivity coefficient to $NO_x$ emissions over the core SMA. The $2^{nd}$-order ozone sensitivity coefficient to $NO_x$ emissions leads ozone to respond muchnonlinear to the reduction in $NO_x$ emissions over Seoul. Nonlinear ozone response to reduction in VOC emissions is mitigated due to the $2^{nd}$-order ozone sensitivity coefficient which is much smaller than the $1^{st}$-order ozone sensitivity coefficient to the emissions in the magnitude.

Evaluation of experimental reliability for trace-quantity of gaseous VOC working standards based on thermal desorption analysis (극미량 휘발성유기화합물질의 기체상 표준시료 조제와 열탈착분석방식에 기초한 분석안정도의 평가)

  • Park, Shin-Young;Kim, Ki-Hyun
    • Analytical Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.553-558
    • /
    • 2006
  • In this study, an attempt was made to measure uncertainties involved in the VOC analysis for the VOC working standards prepared by a dilution technique using Tedlar bags. For this purpose, VOC standard gases of benzene, toluene, xylene, and styrene were prepared at four different concentrations (4, 8, 20, and 40 ppb). These standard samples were then loaded on to the GC system equipped with air server/thermal desorption (AS/TD) system. Each of these four standard concentrations was analyzed individually to derive their respective calibration results. These calibration data sets were then compared across four different compounds. According to this comparison, differences in calibration patterns were moderately insignificant within the selected concentration range of 4~40 ppb. It was also observed that the loss of styrene standard was fairly high compared to other VOCs investigated simultaneously. The results of our study suggest that the analytical uncertainty associated with the preparation of VOC starndard gas using a dilution technique can be assessed in a fairly reasonable manner for samples with a narrow concentration range.

Analysis of detected anomalies in VOC reduction facilities using deep learning

  • Min-Ji Son;Myung Ho Kim
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.4
    • /
    • pp.13-20
    • /
    • 2023
  • In this paper, the actual data of VOC reduction facilities was analyzed through a model that detects and predicts data anomalies. Using the USAD model, which shows stable performance in the field of anomaly detection, anomalies in real-time data are detected and sensors that cause anomalies are searched. In addition, we propose a method of predicting and warning, when abnormalities that time will occur by predicting future outliers with an auto-regressive model. The experiment was conducted with the actual data of the VOC reduction facility, and the anomaly detection test results showed high detection rates with precision, recall, and F1-score of 98.54%, 89.08%, and 93.57%, respectively. As a result, averaging of the precision, recall, and F1-score for 8 sensors of detection rates were 99.64%, 99.37%, and 99.63%. In addition, the Hamming loss obtained to confirm the validity of the detection experiment for each sensor was 0.0058, showing stable performance. And the abnormal prediction test result showed stable performance with an average absolute error of 0.0902.