• Title/Summary/Keyword: Voc

Search Result 1,275, Processing Time 0.028 seconds

Reduction of Lean VOC Emission by Reforming with a Rotating Arc Plasma and Combustion with a Turbulent Partially-Premixed Flame (난류 부분예혼합화염과 로테이팅 아크 플라즈마를 이용한 난연성 유증기의 연소처리)

  • Ahn, Taekook;Lee, Daehoon;Park, Sunho
    • Journal of the Korean Society of Combustion
    • /
    • v.22 no.1
    • /
    • pp.23-31
    • /
    • 2017
  • Large-scale fuel tanks emit massive amount of hardly-combustible VOC mixtures which are light hydrocarbon species in dilution with nitrogen and carbon dioxide. We have developed a lab-scale burner to combust those VOC mixtures by use of a turbulent partially-premixed flame as a pilot flame. For a higher HC treatment ratio, the mixture gases were reformed by a rotating arc plasma device. The results showed that the nitrogen mole fraction and the injecting speed of the VOC mixture influence on the performance of the burner. It was also found that the size of the pilot flame and the power supplied to the plasma device determine the overall HC treatment ratio and the concentrations of CO and NOx in the exhaust gas.

The effect of heat treatment parameters on the emitter formation of the n-type silicon solar cell (n형 규소 태양전지 emitter형성에 미치는 열처리 변수의 영향)

  • Shim, Ji-Myung;Kim, Young-Kwan
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.18 no.5
    • /
    • pp.179-183
    • /
    • 2008
  • Employing screen printing technology, aluminum is applied to the back side of the n-type silicon wafer to see the effect of the heat treatment parameters on the Voc of the solar cell, Heat treatment at $850^{\circ}C$ produces the highest Voc among various heat treatment conditions. Heat treatment at the temperatures higher than $850^{\circ}C$ results in lower Voc, which is due to the destruction of the Al-Si alloy emitter layer. The destruction of Al-Si layer observed to be caused by the vigorous movement of silicon atoms toward aluminum layer during the heat treatment.

A Numerical Analysis of the Abatement of VOC with Photocatalytic Reaction in a Flow Reactor (연속흐름 반응기에서 광촉매 반응에 의한 VOC 물질제거 특성에 대한 수치적 연구)

  • 최우혁;김창녕;정석진
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.7
    • /
    • pp.637-646
    • /
    • 2001
  • VOC(Volatile Organic Compound) removal characteristics in continuous flow reactors have been numerically investigated. The photocatalytic reaction have been simulated with the binding constant and the reaction rate constant obtained from experimental data for the constant-volume batch reactor, and then VOC abatement in continuous flow reactors with the same conditions as those of batch reactor has been analyzed. The standard 4\kappa-\varepsilon$ model and mass conservation equation have been employed for numerical calculation, and heterogeneous reaction rate has been used in terms of the boundary condition of the conservation equation. in the case of the continuous flow reactor, reaction characteristics have been estimated with various inlet velocities and with different number of baffles. The result shows that the concentration distribution and flow patterns are strongly affected by the inlet velocity, and that with the increased inlet velocity, VOC removal rate is increased, while removal efficiency is decreased. This result may be useful in the design of reactors with improved VOC removal efficiency.

  • PDF

Evaluation of Volatile Organic Compounds Levels in Industrial Complex and Nearby Residential Areas of Daegu (대구지역 공단과 인근 주거지역의 휘발성유기화합물질 오염도 평가)

  • Jo, Wan Geun;Lee, Jin U
    • Journal of Environmental Science International
    • /
    • v.13 no.6
    • /
    • pp.519-525
    • /
    • 2004
  • Air pollution from the Daegu industrial complex (Die) in Korea has been a common nuisance and cause of complaints for nearby residents. The current study measured the indoor and outdoor levels of six VOC (benzene, toluene, ethylbenzene, and three isomeric xylenes) at two residential areas with a different proximity to the ODIC, plus the ambient levels at two industrial areas within the boundary of the DDIC. The QA/QC program included the range of correlation coefficient (0.94-0.99) for calibration curves, within the permissible range. Toluene was the most abundant VOC in the ambient air both in residential and industrial areas. Both indoor and outdoor air concentrations of all target VOC except benzene were higher in residential area near the DIC compared to that further away from the DIC. Moreover, the ambient air concentrations of all target VOC except benzene for two industrial sites (A and B) were significantly higher than the outdoor or indoor air concentrations in the two residential areas. The findings further suggested that VOC ambient levels measured in a residential area near the DIC be used as a potential indicator of odor-causing unidentified air pollutants transported from the DIC. Moreover, it was found that the elevated ambient toluene levels outweighed the indoor sources with respect to the environmental exposure of residents nearby the DIC. However, in the residential area further away from the DIC, the toluene indoor sources outweighed the outdoor sources.

Biological Removal of a VOC Mixture in a Two-stage Bioreactor (이단미생물반응조에서 혼합 VOCs의 생분해 특성)

  • Song, Ji-Hyeon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.6
    • /
    • pp.758-766
    • /
    • 2006
  • A two-stage bioreactor, which consists of a biotrickling filter module and a biofilter module in series, was investigated for the enhanced treatment of a VOC mixture, toluene and methyl ethyl ketone (MEK). Throughout the experiments, the overall inlet loading rate was maintained at approximately $43g/m^3/hr$, but the inlet ratios of the VOCs were modified. The experimental results showed that the different ratios of the VOC mixture resulted in changes of overall removal efficiencies, elimination capacities (ECs) and microbial accumulation on the surface of each packing material. The ratio of inlet toluene to MEK at 50 : 150 was found to be most effective in terms of the overall removal efficiency, because, at this condition, MEK (i.e., the hydrophilic compound) was mostly removed in the biotrickling filter module and the following biofilter module was used to remove toluene. It was also found that when the inlet loading rate of the VOC mixture was serially increased stepwise within short-term periods, the ECs for toluene dropped significantly but the ECs for MEK increased at the ratio of the VOC mixture. These results implied that substrate interaction and/or substrate preferable utilization might have an effect on the biological removal of each compound in the two-stage bioreactor; therefore, the bioreactor should be operated in the condition where the substrate interaction could be minimized in order to maximize overall performance of the two-stage bioreactor.

Analyzing Customer Feedback Differences between VOCs and External Channels (VOC와 외부채널간의 고객 피드백 차이 분석)

  • Ahn, Sang Hyeon;Baek, Dong Hyun
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.41 no.3
    • /
    • pp.129-137
    • /
    • 2018
  • VOCs have been used as the most definitive resource to reflect customer feedback when developing products and services. However, due to the development of the Internet and the emergence of SNS, VOC is no longer the only channel that represents customer opinions. There are also a number of studies showing that many customers express complaints through channels other than VOCs. In this paper, we analyze the difference between the official VOC data and the data collected through the external channel, and suggest ways to reflect the various opinions of customers. To do this, this study uses keyword analysis that can identify differences according to frequency through social network, modular analysis to distinguish topics according to centrality and similarity, and emotional analysis to confirm word polarity (positive and negative). The results of this study show that the opinions of the customers were different depending on channels such as VOCs and external channels. Therefore, the collected data through VOC as well as external channels should be used in order to reflect the opinions of customers. In particular, this paper confirms that the results of one channel may vary depending on the channel characteristics even for the same channel. This confirms that collecting voc only on certain channels may differ from what real customers require. Therefore, data collected through VOCs as well as external channels must be used to reflect various customer feedback.

Destruction of Volatile Organic Compounds Using Photocatalyst-Coated Construction Materials (건축자재의 산화티타늄 코팅을 통한 휘발성 유기화합물 분해)

  • Jo Wan-Kuen;Chun Hee-Dong
    • Journal of Environmental Science International
    • /
    • v.14 no.8
    • /
    • pp.785-792
    • /
    • 2005
  • In order to reduce roadside and indoor air pollution for volatile organic compounds VOC), it may be necessary to apply photocatalyst-coated construction materials. This study evaluated the technical feasibility of the application of $TiO_2$ photocatalysis for the removal of VOC present in roadside or indoor air. The photocatalytic removal of five target VOC was investigated: benzene, toluene, ethyl benzene and o,m,p-xylenes. Variables tested for the current study included ultraviolet(UV) light intensity coating materials, relative humidity (RH), and input concentrations. Prior to performing the parameter tests, adsorption of VOC onto the current experiment was surveyed, and no adsorption was observed. Stronger UV intensity provided higher photocatalytic destruction(PCD) efficiency of the target compounds. For higher humidity, higher PCD efficiency was observed. The PCD efficiency depended on coating material. Contrary to certain previous findings, lower PCD efficiencies were observed for the experimental condition of higher input concentrations. The current findings suggested that the four parameters tested in the present study should be considered for the application of photocatalyst-coated construction materials in cleaning VOC of roadside or indoor air.

FMEA Measures for Service Failure Management (서비스 실패 관리를 위한 FMEA 이용 방안)

  • Kim, Hyun Jung;An, Qin Rui;Kim, Soo Wook
    • Journal of Korean Society for Quality Management
    • /
    • v.42 no.1
    • /
    • pp.43-61
    • /
    • 2014
  • Purpose: This study identifies preventive measures for VOC management by analyzing the causes and effects of factors that contribute to high risk service failure using FMEA on KORAIL VOC data. Methods: Two research methods were used. First, a Risk Priority Number (RPN) was assigned to each KORAIL VOC based on Failure Mode and Effect Analysis (FMEA). Second, multiple regression analysis was run with RPN factors that include severity, occurrence, and detection as the independent variables and customer dissatisfaction as the dependent variable. Results: Multiple regression analysis showed that RPN factors including severity, occurrence, and detection had significantly positive relationship with customer dissatisfaction. Based on these results, an FMEA was performed on VOC categories with high RPN for railroad stations including platform, ticketing, ticket verification, parking, and escalator, and VOC categories with high RPN for trains including entrance doors, cafes, air quality, announcement, and ticket verification. Conclusion: This study has practical implications to service failure management. A priority order using FMEA was established for the list of customer dissatisfactions that should be addressed to actively manage service failure, and strategies for tackling this priority list are offered.

Biofilter Treatment of Waste Air Containing Malodor and VOC: 2. Transient Behavior of Biofilter with Improved Design to Eliminate Malodor and VOC (악취 및 VOC를 함유한 폐가스의 바이오필터 처리: 2. 개선된 바이오필터설계에 의한 악취 및 VOC 제거거동)

  • Lee, Eun Ju;Lim, Kwang-Hee
    • Korean Chemical Engineering Research
    • /
    • v.51 no.1
    • /
    • pp.136-143
    • /
    • 2013
  • In this study, both transient behaviors of a biofilter system with improved design and a conventional biofilter were observed to perform the treatment of waste air containing malodor and volatile organic compound (VOC). Their behaviors of removal efficiency and treated concentration of malodor and VOC were compared each other. During 1st~7th stages of improved biofilter system operation it was observed that the order of treated ethanol concentration at each sampling port was switched due to the difference of microbe-population-distribution in spite of the difference of biofilter effective height. However, at 8th stage of its operation, the order of treated ethanol concentration at each sampling port was consistent to the order of biofilter effective height at each sampling port. The same was applied to the case of hydrogen sulfide, even though the difference of switched treated-hydrogen sulfide-concentrations was less than that of switched treated-ethanol-concentrations. The ethanol-removal efficiency of the biofilter system with improved design was ca. 96%, which was greater by 2% than that of the conventional biofilter. The transient behavior of treated hydrogen sulfide concentration of both biofilters were similar to each other. However, the concentration of hydrogen sulfide treated by the biofilter system with improved design was observed lower than that by the conventional biofilter. The hydrogen sulfide-removal efficiency of the biofilter system with improved design was higher by ca. 2% than that of the conventional biofilter. Therefore, the hydrogen sulfide-removal efficiency of the biofilter system with improved design was observed to be enhanced by the same as its ethanol-removal efficiency.

Biodegradation of VOC Mixtures using a Bioactive Foam Reactor I: Reactor Performance (계면활성제 미생물반응기의(혼합 VOCs) 생분해 I: 반응기 거동평가)

  • Shin, Shoung Kyu;Jang, Hyun Sup;Hwang, Sun Jin;Song, Ji Hyeon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.6B
    • /
    • pp.689-694
    • /
    • 2006
  • The system performance of a bioactive foam reactor (BFR), that consists of a foam column using a surfactant and a biodegradation basin containing suspended bacteria, was investigated for the treatment of gaseous toluene or a mixture of four volatile organic compounds (VOCs, benzene, toluene, p-xylene, and styrene). Overall, the BFR achieved stable VOC removal efficiencies, indicating that it can be used as a potential alternative over conventional packed-bed biofilters. Furthermore, a dynamic loading test showed that relatively constant removal was maintained at the elevated loading due to a high mass transfer rate in the foam column. However, as the inlet concentration of VOCs increased, a portion of the VOCs mass-transferred to the liquid phase was stripped out from the biodegradation basin, resulting in a decrease in the overall removal efficiency. In the BFR, the removal efficiency of the individual VOC was mainly determined depending on the biodegradation rate (styrene > toluene > benzene > p-xylene), rather than the mass transfer rate. Consequently, increases in the microbial activity and the volume of the basin could improve the overall performance of the BFR system. Further investigation on microbial activity and community dynamics is required for the BFR when subjected to high loadings of VOC mixtures.