• Title/Summary/Keyword: Vital signs (V/S)

Search Result 8, Processing Time 0.034 seconds

The Study on Effects of Breath-Counting Meditation According to Personal Characteristics (개인적 특성에 따른 수식관 명상의 효과 연구)

  • Jung, Duk-Jin;Lee, Jae-Hyok
    • Journal of Oriental Neuropsychiatry
    • /
    • v.25 no.1
    • /
    • pp.39-46
    • /
    • 2014
  • Objectives: The objective of this study is to investigate the effects of Breath-Counting Meditation according to Personal Characteristics through the changes of Vital Signs (V/S) and Heart Rate Variability (HRV). Methods: 41 adults were classified according to gender and A-type behavior, then each group was compared for the changes on V/S and HRV through Breath-Counting Meditation of 10 minutes. Results: 1) Systolic and diastolic blood pressure were both significantly decreased in females, and the respiration level decreased significantly in both the male and female groups. 2) Respiration level decreased significantly in both the A-type and Non-A-type groups. 3) LF decreased significantly in both the male and female groups. HF increased significantly in both the male and female groups. 4) TP, LF and LF/HF increased significantly and HF decreased significantly in the Non-A-type group. Conclusions: Breath-Counting Meditation has respiratory effects for all groups and HRV of male, female and Non-A-type groups.

Development of Standard Protocol-based Healthcare Services for Optimized Health Management (최적화된 건강관리를 위한 표준 프로토콜 기반 헬스케어 서비스 개발)

  • Park, Hyun-Sang;Kim, Hyun-Young;Kim, Hwa-Sun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.7
    • /
    • pp.969-975
    • /
    • 2018
  • The purpose of this study is to develop a healthcare service based on standard protocol and information communication technology for mother's sustainable postpartum care. The developed service was consisted of a client area where mothers measure, manage and transmit their vital signs using their own smartphone and personal health devices, and a server area that manages and shares with the received mother's vital signs and the results of examination results and personal health records. The client area collects vital signs through the IEEE 11073 Personal Health Device (PHD) using the m-health application of the previous study and Continua Health alliance certified personal health devices and transfers to Health Level Seven (HL7) V2.4, Continuity of Care Record (CCR) and Continuity of Care Document (CCD). The server area consists of a mobile web that manages and shares the HL7 Fast Healthcare Interoperability Resources (FHIR)-compliant personal health records to ensure interoperability of examination results, and a mobile web where the postpartum caregiver enters and manages the results of the mother's examination results and provides it to the mother. In this way, the healthcare service of this study securing continued exchanges between the mother and postpartum caregiver improves the quality of life of the mother not only to satisfy the needs of the mother who was discharged but also through self-management and postpartum. In the future, we will conduct a study applying mothers and postpartum caregiver after approval of a clinical trail at a university hospital to evaluate developed healthcare services.

A Pilot Study on the Psychological and Physical Responses of Breath - Counting Meditations (수식관 명상의 심리적 신체적 반응 연구 - 단일군)

  • Lee, Jae-Hyok
    • Journal of Oriental Neuropsychiatry
    • /
    • v.25 no.1
    • /
    • pp.47-54
    • /
    • 2014
  • Objectives: The purpose of this research was to analyze the responses of breath-counting meditations with the psychological test and the physical index. Methods: Breath-counting meditation was applied to 10 normal adults. Then, clinical research State-Trait Anxiety Inventory (STAI), State-Trait Anger eXpression Inventory (STAXI), Psychosocial Well-being Index Short Form (PWI-SF), Brief Encounter Psychosocial Instrument-Korean version (BEPSI-K), Heart Rate Variability (HRV), and Vital Signs (V/S) were carried out to analyze the responses of breath-counting meditations. Results: 1) Systolic Blood Pressure (SBP) decreased on the fifteenth day of breath-counting meditation, and Body Temperature (BT) increased on the fifteenth day. In addition, respiration decreased throughout the period of breath-counting meditation. 2) Standard deviations of N-N interval and Total Power (TP) of HRV all significantly increased on the fifteenth day of breath-counting meditation. 3) Scores of STAI1, STAXI1, STAXI2, and PWI-SF decreased after the breath-counting meditation. Conclusions: The results suggested that breath-counting meditations have positive responses to anger, anxiety and stress.

Development of HL7 V 2.5 Middleware for Patient Monitoring Device (환자감시장치를 위한 HL7 V2.5 미들웨어의 개발)

  • Kim, Hyung-Hoi;Cho, Hune;Tran, Tung;Hong, Hae-Sook;Kim, Hwa-Sun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.9
    • /
    • pp.1680-1687
    • /
    • 2007
  • A hospital room has multiple patient monitoring devices at the bedside to monitor his or her status. However, vital sign monitors, ventilator and other bedside devices are made by a variety of different manufacturers and often cannot easily interface to the hospital information system. Medical environments incorporate complex and integrated data networks to transfer vast amounts of patient information, such as images, waveforms, and other forms of digital data. Hence, to assure interoperability of images, waveforms and patient data, Health Level Seven (HL7) was developed as an international standard to facilitate the communicating and storing of medical data. In this study, we developed middleware capable of receiving data from mCare 300 vital signs monitoring devices and converting the data to HL7 data format. The HL 7 middleware streamline clinical workflow and support patients. Therefore, clinical expertise are empowered to respond to dynamic healthcare situation as soon as they emerged, and consequently quality of care while helping to reduce the length of a patient's stay in a hospital.

Surgical Repair for Ebstein's Anomaly (Ebstein 기형의 수술 -2례 보고-)

  • naf
    • Journal of Chest Surgery
    • /
    • v.12 no.3
    • /
    • pp.289-296
    • /
    • 1979
  • For years, physicians and anatomists have been interested in the heart that has one functioning ventricle. Various terms have been suggested for this entity including single ventricle, common ventricle, double-inlet left ventricle, cor biatriatum triloculare, and primitive ventricle. In this report, the term "single ventricle" is utilized as suggested by Van Praagh, and is defined as that congenital cardiac anomaly in which a common or separate atrioventricular valves open into a ventricular chamber from which both great arterial trunks emerge. An outlet chamber, or infundibulum, may or may not be present and give rise to the origin of either of the great arteries. This definition excludes the entity of mitral and tricuspid atresia. An 11 year old cyanotic boy was admitted chief complaints of exertional dyspnea and frequent upper respiratory infection since 2 weeks after birth. He was diagnosed as inoperable cyanotic congenital heart disease, and remained without any corrective treatment up to his age of 11 year when he suffered from aggravation of symptoms and signs of congestive heart failure for 2 months before this admission. On 22nd of May 1979, he was admitted for total corrective operation under the impression of tricuspid atresia suggested by a pediatrician. Physical check revealed deep cyanosis with finger and toe clubbing, and grade V systolic ejection murmur with single second heart sound was audible at the left 3rd intercostal space. Development was moderate in height [135 cm] and weight[28Kg]. Routine lab findings were normal except increased hemoglobin [21.1gm%], hematocrit [64 %], and left axis deviation with left ventricular hypertrophy on EKG. Cardiac catheterization and angiography revealed 1-transposition of aorta, pulmonic valvular stenosis, double inlet of a single ventricle with d-loop, and normal atriovisceral relationship [Type III C solitus according to the classification of Van Praagh]. At operation, longitudinal incision at the outflow tract of right ventricle in between the right coronary artery and its branch [LAD from RCA] revealed high far anterior aortic valve which had fibrous continuity with mitral annulus, and pulmonic valve was stenotic up to 4 mm in diameter positioned posterolaterally to the aorta. Ventricular septum was totally defective, and one markedly hypertrophied moderator band originated from crista supraventricularis was connected down to the imaginary septum of the ventricular cavity as a pseudoseptum of the ventricle. Size of the defect was 3X3 cm2 in total. Patch closure of the defect with a Teflon felt of 3.5 x 4 cm2 was done with interrupted multiple sutures after cut off of the moderator band, which was resutured to the artificial septum after reconstruction of the ventricular septum. Pulmonic valvotomy was done from 4 mm to 11 mm in diameter thru another pulmonary arteriotomy incision, and right ventriculotomy wound was closed reconstructing the right ventricular outflow tract with pericardial autograft of 3 x 4 cm2. Atrial septal defect of 2 cm in diameter was closed with 3-0 Erdeck suture, and atrial wall was sutured also when rectal temperature reached from 24`C to 35.5`C. Complete A-V block was managed with temporary external pacemaker with a pacing rate of 110/min. thru myocardial wire, and arterial blood pressure of 80/50 mmHg was maintained with Isuprel or Dopamine dripping under the CVP of 25-cm saline. Consciousness was recovered one hour after the operation when his blood pressure reached 100 /70 mmHg, but vital signs were not stable, and bleeding from the pericardial drainage and complete anuria were persisted until his heart could not capture the pacemaker impulse, and patient died of low output syndrome 320 min after the operation.

  • PDF

Design and Implementation of a Wearable $SpO_2$ Module based WSN (무선센서네트워크 기반의 손목 착용형 $SpO_2$ 모듈 설계 및 구현)

  • Jung, Sang-Joong;Seo, Yong-Su;Chung, Wan-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.495-498
    • /
    • 2008
  • This paper describes design of a real-time, wearable reflectance pulse oximetry which is based Wireless Sensor Network. For the purpose of continuously monitoring vital signs of a human, wearable reflectance pulse oximetry is built into a wrist type that can be obtained $SpO_2$ value of patient unobtrusively. This designed $SpO_2$ module is based on a low-power 8 bit ATmega128L microcontroller operating in 3V. Low power operating $SpO_2$ module was integrated to wireless sensor node for user's health monitoring. This paper is focused on the successful integration of all these components into wearable reflectance pulse oximetry and evaluates its ability to measure patient' $SpO_2$ value. Information from this sensor was wirelessly transmitted to a base-station for storage and display purposes.

  • PDF

CONVERTING FROM ORAL SEDATION TO INTRAVENOUS SEDATION USING TOPICAL ANESTHETICS ON SKIN AFTER ORAL SEDATION FAILURE (경구진정 실패 후 피부 도포마취제를 사용한 정주진정으로의 전환 치료)

  • Lee, Eun-Hui;Kim, Seung-Oh;Kim, Jong-Soo;Yoo, Seung-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.2
    • /
    • pp.213-217
    • /
    • 2010
  • The use of chloral hydrate and hydroxyzine for oral sedation is most effective in children aged less than 36 months and weighing less than 15 kg. Children who do not belong to this category may show frequent movements due to shallow sedation level, and it can lead to sedation failures. One of the solutions to such sedation failure is conversion to deeper sedation. But, it is not so much of an option, since inhalation anesthetics and devices are required. In this case, conversion from oral sedation to intravenous sedation was successfully achieved without causing injection pain while searching for an intravenous route, by using EMLA cream (Eutectic Mixture of Local Anesthesia). A patient aged 46 months and weighing 15 kg visited the Pediatric Department of Dankook University Dental Hospital. Treatment under TSD(Tell Show Do) was offered, but due to the parent's request, oral sedative measures were taken. Considering prompt converting from oral sedation to iv sedation in case the oral sedation fails, EMLA cream was apllied preemptively. Adequate sedation level could not be achieved after 90 minutes of oral administration, therefore, under the parent's consent, intravenous route was prepared after conscious sedation by $N_2O-O_2$. During treatment, $ETCO_2$, $SPO_2$ and heart rate was monitored every 5 minutes. The patient showed stable vital signs and did not show any movements. The whole procedure took two and a half hours in total, and the treatment was completed without any adverse effects.

Measure of Agreement between Prehospital EMS Personnel and Hospital Staffs using Guidelines for Field Triage of Injured Patients (외상환자의 병원 전 및 병원단계 중증도 평가의 일치도)

  • Kim, Dae Kon;Hong, Ki Jeong;Noh, Hyun;Hong, Won Pyo;Kim, Yu Jin;Shin, Sang Do;Park, Ju Ok
    • Journal of Trauma and Injury
    • /
    • v.27 no.4
    • /
    • pp.126-132
    • /
    • 2014
  • Purpose: The field trauma triage for injured patients is essential for trauma care system. In this study, agreement of patient evaluation between by prehospital EMS personnel and by hospital staffs and the appropriateness of prehospital triage were evaluated. Methods: This observational study was conducted from September to October 2012 for 5 weeks. During this period, EMT evaluated patient's severity according to guideline for field triage and recorded. Same guideline was applied in 26 hospitals for patients with EMS use. Kappa statistics were used to measure agreement for each item of guideline. Finally, over-triage and under-triage rate of EMT were calculated. Results: During study period, total 3,106 patients were transferred to 26 hospital emergency departments with EMS use. Kappa statistics for "vital signs" items were 0.45 for mentality lower than V and 0.44 for systolic blood pressure lower than 90 mmHg as a moderate agreement. In "anatomy of injury" items Kappa statistics were very low. In "mechanism of injury" items Kappa statistics were 0.28 for high-rise fall down and 0.27 for high energy traffic accident but in other items Kappa statistics were very low. 362 patients (12.0%) were over-triaged and 281 patients (9.3%) were under-triaged. Conclusion: Field triage can be applied but need to evaluate and modify in order to become accurate and sensitive for decision of transportation.