• Title/Summary/Keyword: Vital energy

Search Result 395, Processing Time 0.025 seconds

Assessment of Post-LOCA Radiation Fields in Service Building Areas for Wolsong 2, 3, and 4 Nuclear Power Plants (월성 원자력 발전소 2,3,4호기에서의 LOCA 사고후 보조건물의 방사선장 평가)

  • Jin, Yung-Kwon;Kim, Yong-Il
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.1
    • /
    • pp.53-64
    • /
    • 1995
  • The radiation fields following the large loss of coolant accident (LOCA) have been assessed for the vital areas in the service building of Wolsong 2, 3, and 4 nuclear power plants. The ORIGEN2 code was used in calculating the fission product inventories in the fuel. The source terms were based upon the activity released following the dual failure accident scenario, i.e., a LOCA followed by impaired emergency core cooling (ECC). Configurations of the reactor building, the service building, and the ECC system were constructed for the QAD-CG calculations. The dose rates and the time-integrated doses were calculated for the time period of upto 90 days after the accident. The results showed that the radiation fields in the vital access areas were found to be sufficiently low. Some areas however showed relatively high radiation fields that may require limited access.

  • PDF

Implementation of a Bluetooth-LE Based Wireless ECG/EMG/PPG Monitoring Circuit and System (블루투스-LE 기반 심전도/근전도/맥박 무선 모니터링 회로 및 시스템 구현)

  • Lee, Ukjun;Park, Hyeongyeol;Shin, Hyunchol
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.6
    • /
    • pp.261-268
    • /
    • 2014
  • This paper presents a electrocardiogram(ECG), electromyogram(EMG), and Photoplethysmography(PPG) signal wireless monitoring system based on Bluetooth Low Energy (BLE). ECG and EMG sensor interface analog front-end circuits are designed by using off-the-shelf parts. Texas Instruments(TI)'s CC2540DK is used for BLE-based communication. Two CC2540DK modules are used as Peripheral and Central nodes. In peripheral device, vital signals are acquired by the analog front-ends and fed to ADC for analog-to-digital conversion. The peripheral transmitts the data through the air to the central device. The central device receive the data and sends them to PC using UART. GUI is designed using Labview for displaying the acquired vital signals. The developed system can be used for future ubiquitous wireless healthcare system based on bluetooth 4.0.

Clinical Applications of the Meridian Theory in the Point of Hyungsang Medicine (형상의학적(形象醫學的) 관점(觀点)에서 본 경락이론(經絡理論)의 임상활용(臨床活用))

  • Kang, Kyung-Hwa;Song, Choon-Ho;Kim, Hyung-Gyu;Lee, Yong-Tae
    • Korean Journal of Acupuncture
    • /
    • v.21 no.1
    • /
    • pp.149-173
    • /
    • 2004
  • Objective & Methods : In the point of several medical books included 'Internal Classic' and Hyungsang medicine, the writer studied about meridian theory and it's disorders, after adapting to acupuncture and herb medicine. Results : 1. Dr. Jisan explained concretely physiological and pathological meridian appearances with using metaphor about phenomenons of nature and human living. 2. Shapes corresponding to meridian are considered as Yukkyunghyung formed by more or less of vigor and blood, and by tendency of up and down in eyes and nose, and also contained diseases of viscera and characters. 3. The colors connected with meridian are changed according to conditions, and meridian is seen through colors. And then colors is the properties of vital energy and symbol of spirit, that is expressed as aspect of essence, vigor, spirit and blood, as the original color of five viscera, as the colors of four seasons and as the colors of diseases. So the changes of feelings are appeared to meridian flow. 4. The method of examining pulse for meridian disorders is applied to Jisan diagram. Jisan diagram is devised from mutual communication of viscera and connection with inside and outside. It is conjugated widely in clinical examination to be distinguished into Dam-Bangkwang, into diseased part of viscera and into meridian. Also it is conjugated recuperation of diseases. 5. The meridian diseases are appeared all the distributed parts of meridian, especially skin, hair, eyebrow, and the ends of the extremities which are sensitive to stimulus. The causes are the disharmony between vital energy and blood and the discordance of six atmospheric variation. The symptoms are skinny aches, itching and eruption, etc. Conclusions : The acupuncture of Hyungsang medicine which utilizes classification of shapes, examining pulse according to Jisan diagram and demonstration of symptoms, is very effective and required systematical study from now on.

  • PDF

The effects of Sipjeondaebotanggamibang on anti-tumor chemotherapheutic cytotoxicity and lysosomal enzymes of tumor cell (십전대보탕가미방(十全大補湯加味方)이 항암화학요법제(抗癌化學療法劑)의 세포독성(細胞毒性) 및 종양세포(腫瘍細胞)의 lysosomal enzymes에 미치는 영향(影響))

  • Lee, Hyung-Ju;Jeon, Byung-Hun;Won, Jin-Hee;Moon, Gu;Moon, Seok-Jae
    • The Journal of Internal Korean Medicine
    • /
    • v.19 no.1
    • /
    • pp.491-504
    • /
    • 1998
  • Mainly side effects of antitumor chemotheraphy are fatigue, G-Ⅰ trouble(such as vomitting, nausea, diarrhea) and reduction of medullary function etc. Differentiated from syndromes in oriental medicine, above symptoms are recognized to 'Deficiency of both ki(vital energy) and blood'. And SDT(Sipjeondaebotang) has been widely used in 'Deficiency of both ki(vital energy) and blood'. Dr. Mun's SDTG(Sipjeondaebotanggamibang) consists of SDT plus several herb medicines-these have antitumor effect and reduce chemotherapheutic side effect. This experiment was undertaken to study the effects of SDTG on chemotherapheutic side effect and cytotoxicity. The results obtained in this study were as follows: Antitumor activities of the ethanol extract from SDTG(Sipjeondaebotanggamibang) and MMC(Mytomycin) on ascitis form of calcinoma in mice is a little improved. Especialy mean survival times of the group of SDTG(200mg/kg) and MMC(0.1mg/kg) is improved over 50%. When SDTG and MMC is administrated together, the weight of tumor is more decreased than MMC alone. The effect of the ethanol extract from SDTG and MMC on the lysosomal enzymes in Ehrich ascites carcinoma cell are more significantly improved than MMC alone. SDTG extract increases both NKcell conjugation and cyto-lysis against target cell. According to the above results it is recognized that SDTG increases the chemotherapheutic cytotoxicity of MMC and the activity of NKcell.

  • PDF

Literatural Study on the Causes of Infertility in Women (여성(女性) 불임(不姙)의 원인(原因)에 관(關)한 문헌적(文獻的) 고찰(考察))

  • Kim, Eun Seop;Yoo, Dong Yeol
    • Journal of Haehwa Medicine
    • /
    • v.9 no.1
    • /
    • pp.267-285
    • /
    • 2000
  • According to the literatural study on the causes of Infertility in women, the results were as follows. 1. The causes of Infertility in women were arranged scholarly thoery during to Jin-Yuan era (金 元 時代) from Huang-Di-Nei-Jing(黃帝內經), and literatures after Ming-Qing era(明 淸 時代) divided and added one's own thoery since they choose preceding thoery. 2. In the Modern Medicine, the causes of Infertility in women are divided the product obstruction of Oocyte, the union obstruction of sperm and oocyte by abnormality of vagina, cervix, corpus, fallopian tubes, pelvic, and peritoneum, Endocrine factor, Immunologic factor, and Emotion factor. 3. In the Oriental Medicine, the causes of Infertility in women are attached importance to functional side as 'asthenia-cool of uterus'(子宮虛寒), 'deficiency of vital energy and blood'(氣血虛), 'deficiency of yin'(陰虛), 'impairement of seven emotion'(七情傷), 'disease of extra mierdians'(寄經病), and so forth; while on the other in the Modern Medicine, the causes of Infertility in women are attached importance to organic side as abnormality of uterus and ovary. 4. In the successive literatures, 'asthenia-cool of uterus'(子宮虛寒) occupied most frequency in the causes of Infertility in women and in the next obesity(體肥), 'deficiency of vital energy and blood'(氣血虛), menstrual irregularity(月經不調), deficiency of yin'(陰虛), 'impairement of seven emotion'(七情傷), emaciation(體瘦), 'disease of extra mierdians'(寄經病), and so forth occupied much frequency. 5. In the bodily form, obesity(體肥) and emaciation(體瘦) occupied comparatively more frequency.

  • PDF

Improvement of Calculation Accuracy in the Electron Monte Carlo Algorithm with Optional Air Profile Measurements

  • Sung, Jiwon;Jin, Hyeongmin;Kim, Jeongho;Park, Jong Min;Kim, Jung-in;Choi, Chang Heon;Chun, Minsoo
    • Progress in Medical Physics
    • /
    • v.31 no.4
    • /
    • pp.163-171
    • /
    • 2020
  • Purpose: In this study, the accuracies of electron Monte Carlo (eMC) calculation algorithms were evaluated to determine whether electron beams were modeled by optional air profiles (APs) designed for each applicator size. Methods: Electron beams with the energies of 6, 9, 12, and 16 MeV for VitalBeam (Varian Medical System, Palo Alto, CA, USA) and 6, 9, 12, 16, and 20 MeV for Clinac iX (Varian Medical System) were used. Optional APs were measured at the source-to-detector distance of 95 cm with jaw openings appropriate for each machine, electron beam energy, and applicator size. The measured optional APs were postprocessed and converted into the w2CAD format. Then, the electron beams were modeled and calculated with and without optional APs. Measured profiles, percentage depth doses, penumbras with respect to each machine, and energy were compared to calculated dose distributions. Results: For VitalBeam, the profile differences between the measurement and calculation were reduced by 0.35%, 0.15%, 0.14%, and 0.38% at 6, 9, 12, and 16 MeV, respectively, when the beams were modeled with APs. For Clinac iX, the differences were decreased by 0.16%, -0.31%, 0.94%, 0.42%, and 0.74%, at 6, 9, 12, 16, and 20 MeV, respectively, with the insertion of APs. Of note, no significant improvements in penumbra and percentage depth dose were observed, although the beam models were configured with APs. Conclusions: The accuracy of the eMC calculation can be improved in profiles when electron beams are modeled with optional APs.

Protective Effect of the Water Extract of Tissue Cultured Root of Wild Ginseng Against Doxorubicin Toxicity (배양산삼 추출액의 Doxorubicin 독성 완화 효과)

  • Choi, Kyung-Un;Lee, Pyeong-Jae;Kim, Ho-Hyun
    • The Korea Journal of Herbology
    • /
    • v.24 no.3
    • /
    • pp.13-19
    • /
    • 2009
  • Objectives : This study was aimed to define the protective effect of Tissue Cultured Root of Wild Ginseng (CWG) against doxorubicin (Doxo) toxicity, and investigate the anti-tumor synergic effect of CWG in combination with Doxo in tumor-bearing C57BL/6 mice. Methods : Tumor-bearing mice were established by single inoculation with B16/F10 melanoma cells (2$\times$10$^6$/ml) subcutaneously. Tumor-bearing mice (tumor volume between 50-100 mm$^3$) were selected and divided them into control, Doxo, and Doxo+CWG group. Mice of Doxo group were received with Doxo (4 mg/kg of B.W.) intraperitoneally at 0, 4, 8 days after starting the experiment. Mice of Doxo+CWG group were received CWG water extract during 12 days in combination with Doxo treatment. The body weight, tumor volume, tumor weight, and organ weight (heart, liver, kidney, and testis) were measured. And serum SPK, GOT and creatinine values were analysed. Results : The volume and weights of tumor masses in Doxo group were decreased significantly compared with the those of control group. And the those of Doxo+CWG group were not significantly different from the those of Doxo group. Whereas the weight of body, liver, kidney and testis in Doxo+CWG group were increased significantly compared with the those of Doxo group. The level of serum CPK and GOT in Doxo group were increased compared with the those of control group. But the value of Doxo+CWG group were decreased significantly compared with the values of Doxo group. Conclusions : These results suggest that CWG has protective effect against doxorubicin toxicity. And these effect is guessed that is caused in augmentation of vital energy.

MCRO-ECP: Mutation Chemical Reaction Optimization based Energy Efficient Clustering Protocol for Wireless Sensor Networks

  • Daniel, Ravuri;Rao, Kuda Nageswara
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.7
    • /
    • pp.3494-3510
    • /
    • 2019
  • Wireless sensor networks encounter energy saving as a major issue as the sensor nodes having no rechargeable batteries and also the resources are limited. Clustering of sensors play a pivotal role in energy saving of the deployed sensor nodes. However, in the cluster based wireless sensor network, the cluster heads tend to consume more energy for additional functions such as reception of data, aggregation and transmission of the received data to the base station. So, careful selection of cluster head and formation of cluster plays vital role in energy conservation and enhancement of lifetime of the wireless sensor networks. This study proposes a new mutation chemical reaction optimization (MCRO) which is an algorithm based energy efficient clustering protocol termed as MCRO-ECP, for wireless sensor networks. The proposed protocol is extensively developed with effective methods such as potential energy function and molecular structure encoding for cluster head selection and cluster formation. While developing potential functions for energy conservation, the following parameters are taken into account: neighbor node distance, base station distance, ratio of energy, intra-cluster distance, and CH node degree to make the MCRO-ECP protocol to be potential energy conserver. The proposed protocol is studied extensively and tested elaborately on NS2.35 Simulator under various senarios like varying the number of sensor nodes and CHs. A comparative study between the simulation results derived from the proposed MCRO-ECP protocol and the results of the already existing protocol, shows that MCRO-ECP protocol produces significantly better results in energy conservation, increase network life time, packets received by the BS and the convergence rate.

Improved Mechanical Fault Identification of an Induction Motor Using Teager-Kaiser Energy Operator

  • Agrawal, Sudhir;Giri, V.K.
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.5
    • /
    • pp.1955-1962
    • /
    • 2017
  • Induction motors are a workhorse for the industry. The condition monitoring and fault analysis are the main concern for the engineers. The bearing is one of the vital segment of the induction machine and the condition of the whole machine is decided based on the condition of the bearing. In the present paper, the vibration signal of the bearing has been used for the analysis. The first line of action is to perform a statistical analysis of the vibration signal which gives trends in signal. To get the location of a fault in the bearing the second action is to develop an index based on Wavelet Packet Transform node energy named as Bearing Damage Index (BDI). Further, Teager-Kaiser Energy Operator (TKEO) has been calculated from higher index value to get the envelope and finally Power Spectral Density (PSD) has been applied to identify the fault frequencies. A performance index has also been developed to compare the usefulness of the proposed method with other existing methods. The result shows that the strong amplitude of fault characteristics and its side bands help to decide the type of fault present in the recorded signal obtained from the bearing.

Studies on Variable Liquid-Column Oscillator for High Efficiency Floating Wave Energy Conversion System (가변 수주진동장치를 이용한 고효율 파력발전에 관한 연구)

  • Yang, Dong-Soon;Cho, Byung-Hak
    • Journal of Ocean Engineering and Technology
    • /
    • v.23 no.5
    • /
    • pp.15-24
    • /
    • 2009
  • The results of a simulation study of variable liquid column oscillations in U-tanks with a novel control scheme are presented. The configuration under investigation is analogous to that of the tuned liquid-column damper used to suppress oscillatory motion in large structures like tall buildings and cargo ships. However, by virtue of an adequate controller, the response of amplitude of the U-tanks becomes larger in a desired frequency range. The motion of wave energy conversion system equipped with a variable liquid column oscillator is described by a series of nonlinear differential equations. The equations describe the motion of body under ocean wave excitation, and the motion of liquid with an air-spring effect caused by the compression and expansion of air in vertical liquid columns and air chambers. It is shown that the effect of the air-spring has a vital role to maintain the natural frequency of oscillation in the system to synchronize with the frequency of the ocean wave, thus the system provides the most effective mode for energy extraction from the ocean.