• Title/Summary/Keyword: Visual stimulator

Search Result 19, Processing Time 0.019 seconds

A Display-based Visual Stimulator for Psychophysical and Electrophysiological Color Sensitivity Measurements

  • Hwang, Jisoo;Park, Seung-Nam;Park, Cheol-Min;Lee, Geun Woo;Kim, Kiseong
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.145-150
    • /
    • 2012
  • We present a display-based visual stimulator for psychophysical and electrophysiological visual sensitivity measurements. The stimulator offers various psychophysical visual stimuli and transfers the signals from external devices along with the stimulation signals to an electrophysiological recorder. As an experimental demonstration, we perform a visual sensitivity experiment in the mesopic vision range by using the display-based stimulator. The intensity of the steady-state visual evoked potential is observed to correlate with the luminance of the flickering visual stimulation. For the psychophysically determined detection thresholds, we determine the mesopic luminance, showing agreement with the perceived brightness within the uncertainty of the luminance measurement.

An Arbitrary Waveform 16 Channel Neural Stimulator with Adaptive Supply Regulator in 0.35 ㎛ HV CMOS for Visual Prosthesis

  • Seo, Jindeok;Lim, Kyomuk;Lee, Sangmin;Ahn, Jaehyun;Hong, Seokjune;Yoo, Hyungjung;Jung, Sukwon;Park, Sunkil;Cho, Dong-Il Dan;Ko, Hyoungho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.1
    • /
    • pp.79-86
    • /
    • 2013
  • We describe a neural stimulator front-end with arbitrary stimulation waveform generator and adaptive supply regulator (ASR) for visual prosthesis. Each pixel circuit generates arbitrary current waveform with 5 bit programmable amplitude. The ASR provides the internal supply voltage regulated to the minimum required voltage for stimulation. The prototype is implemented in $0.35{\mu}m$ CMOS with HV option and occupies $2.94mm^2$ including I/Os.

fMRI STUDTY ON HUMAN BRAIN'S ACTIVATION BY THE BRAIN STIMULATOR

  • Jeong, Hee-Chang;Choe, Bo-Young;Chung, Sung-Taek;Lee, Hyoung-Koo;Suh, Tae-Suk
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.359-359
    • /
    • 2002
  • Brain Stimulator processes both visual and audible stimulus and send them human sensory organ. The stimulus was accepted by our sensory organ effect upon human mental function. In this study, we examine the actual effect of commercial brain stimulator using tMRI system.

  • PDF

Functional MRI of Visual Cortex: Correlation between Photic Stimulator Size and Cortex Activation (시각피질의 기능적 MR 연구: 광자극 크기와 피질 활성화와의 관계)

  • 김경숙;이호규;최충곤;서대철
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.114-118
    • /
    • 1997
  • Purpose: Functional MR imaging is the method of demonstrating changes in regional cerebral blood flow produced by sensory, motor, and any other tasks. Functional MR of visual cortex is performed as a patient stares a photic stimulation, so adaptable photic stimulation is necessary. The purpose of this study is to evaluate whether the size of photic stimulator can affect the degree of visual cortex activation. Materials and Methods: Functional MR imaging was performed in 5 volunteers with normal visual acuity. Photic stimulator was made by 39 light-emitting diodes on a plate, operating at 8Hz. The sizes of photic stimulator were full field, half field and focal central field. The MR imager was Siemens 1.5-T Magnetom Vision system, using standard head coil. Functional MRI utilized EPI sequence (TR/TE= 1.0/51. Omsec, matrix $No.=98{\times}128$, slice thickness=8mm) with 3sets of 6 imaging during stimulation and 6 imaging during rest, all 36 scannings were obtained. Activation images were obtained using postprocessing software(statistical analysis by Z-score), and these images were combined with T-1 weighted anatomical images. The activated signals were quantified by numbering the activated pixels, and activation a index was obtained by dividing the pixel number of each stimulator size with the sum of the pixel number of 3 study using 3 kinds of stimulators. The correlation between the activation index and the stimulator size was analysed. Results: Mean increase of signal intensities on the activation area using full field photic stimulator was about 9.6%. The activation index was greatest on full field, second on half field and smallest on focal central field in 4. The index of half field was greater than that of full field in 1. The ranges of activation index were full field 43-73%(mean 55%), half field 22-40 %(mean 32%), and focal central field 5-24%(mean 13%). Conclusion: The degree of visual cortex activation increases with the size of photic stimulator.

  • PDF

Efficacy of Low Frequency Stimulator in Patients with Frozen Shoulder (오십견 환자의 치료에 있어서 저주파자극기의 효과)

  • Lim, Yun Hee;Lee, Pyung Bok;Seo, Myung Sin;Park, Sang Hyun;Oh, Yong Seok;Park, Ji Hyun
    • The Korean Journal of Pain
    • /
    • v.18 no.2
    • /
    • pp.156-160
    • /
    • 2005
  • Background: Frozen shoulder is not an uncommon disease, which is associated with chronic pain and joint movement limitation. However, there are numerous devices to assist in the treatment of shoulder pain, but their efficacy has not been proven and their use remains immensely controversial. Therefore, a randomized clinical study was conducted to determine the effectiveness of a low-frequency stimulator for the treatment of frozen shoulder. Methods: A randomized clinical trial was carried out on 40 patients with frozen shoulder, with 40 patients assigned to two groups; a control treatment group (group C, n = 20) and a low frequency stimulator application group (group T, n = 20). Both groups were given a routine treatment modality, such as trigger point injection, intramuscular stimulation or suprascapular nerve block etc. The level of the shoulder pain was evaluated using a 100mm VAS (visual analog scale) at each visit, with the limitation in the range of motion simultaneously evaluated. Results: All the subjects improved after treatment, with the VAS scores after termination of treatment showed a statistically significant reduction (P < 0.05). However, there was no significant difference between the two groups. One month after termination of 5 cycles of treatment, group T maintained their improved state, whereas the pain in some of those in group C reemerged, which also showed a statistically significant difference (P < 0.05). The limitation in the range of motion improved, with most subjects able to resume daily activity. Conclusions: Although the low frequency stimulation provided no more pain relief than routine treatment, the effect was significantly prolonged. From this result, low frequency stimulation can be considered to aide the therapeutic effect of classical frozen shoulder therapy.

A 16-channel Neural Stimulator IC with DAC Sharing Scheme for Artificial Retinal Prostheses

  • Seok, Changho;Kim, Hyunho;Im, Seunghyun;Song, Haryong;Lim, Kyomook;Goo, Yong-Sook;Koo, Kyo-In;Cho, Dong-Il;Ko, Hyoungho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.5
    • /
    • pp.658-665
    • /
    • 2014
  • The neural stimulators have been employed to the visual prostheses system based on the functional electrical stimulation (FES). Due to the size limitation of the implantable device, the smaller area of the unit current driver pixel is highly desired for higher resolution current stimulation system. This paper presents a 16-channel compact current-mode neural stimulator IC with digital to analog converter (DAC) sharing scheme for artificial retinal prostheses. The individual pixel circuits in the stimulator IC share a single 6 bit DAC using the sample-and-hold scheme. The DAC sharing scheme enables the simultaneous stimulation on multiple active pixels with a single DAC while maintaining small size and low power. The layout size of the stimulator circuit with the DAC sharing scheme is reduced to be 51.98 %, compared to the conventional scheme. The stimulator IC is designed using standard $0.18{\mu}m$ 1P6M process. The chip size except the I/O cells is $437{\mu}m{\times}501{\mu}m$.

A study of sight-psychological effects by a color area of greenspace (녹지의 색면적에 따른 시각심리적 효과에 관한 연구)

  • 김은일
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.26 no.1
    • /
    • pp.36-43
    • /
    • 1998
  • We compared the electroencephalogram, blood pressure, and sensory evaluation inspectioni several color of Petunia hybrida to analyze the physiopsychological effects of a plant. Considering occipital is related to visuosensory field, green color is thought as mild visual stimulator unlike to pink color. The results are coincident with the well-known facts that green color is less stimulating color. It is also accorded with the sensory evaluation results that green color showed te feeling of blue and stable. In case of green color is showed the feeling of blue and stable. In case of green color the generatioin of alpha waves increased according to the increase color area. Therefore it is thought that green color helps decrease of visual stimulation and increase in visual stability. However it is thought that pink has less physiopsychological effects on human beings depending on area sizes than green has.

  • PDF

Two Cases of Plantar Fasciitis Treated with Magnetic Acupuncture

  • Yun, Gee Won;Kang, Jae Hui;Oh, Seo Young;Park, Jung Hwan;Lee, Hyun
    • Journal of Acupuncture Research
    • /
    • v.34 no.1
    • /
    • pp.89-96
    • /
    • 2017
  • Objectives : The aim of the study was to ascertain the effectiveness of magnetic acupuncture in patients with plantar fasciitis. Methods : The patients were treated with magnetic acupuncture using a magnetic therapy stimulator (Whata 153), as well as with moxibustion therapy. Acupuncture treatment was conducted on the acupoints of Ashi-as well as on 太谿 (KI3), 崑崙 (BL60), and 委中 (BL40)-for 15 minutes. The intensity of pain was evaluated using the visual analogue scale (VAS), and the tenderness threshold (TT) was measured at each visit using an algometer. Results : After treatment, evaluation using the VAS had improved, as had the TT; furthermore, plantar fasciitis pain was reduced. Conclusion : Magnetic acupuncture relieved pain in plantar fasciitis. In further clinical study, more research on magnetic acupuncture is required.

Development of Programmable Nerve Stimulator ( I ) - Implementation of the Nerve Stimuli Waveform Generator using the Microprocessor - (프로그램 가능한 신경 자극기 개발 ( I ) - 마이크로프로세서를 이용한 신경자극 파형 발생기 구현 -)

  • Kim, K.W.;Eum, S.H.;Lee, S.Y.;Jang, Y.H.;Jun, K.R.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.260-265
    • /
    • 1996
  • The purpose of this study was to implemented a general purpose programmable nerve stimulator system as a research tool for studying psychophysiological performance associated with various stimulation waveform. This system is composed of hardware and software, the former are the personal computer(180586) and control unit(one-chip microprocessor, D/A converter, digital output), the latter are programmed in VISUAL BASIC and ASSEMBLY Which are programmed for the programmable nerve stimuli pattern editor and communication interface, waveform preprocessing, and stimuli generator. The control unit which is entrolled by the personal computer is capable of delivering the programmable nerve stimuli waveform. This system has research potential for determining the effect of various neuromuscular blockade in alternated physiological stat is.

  • PDF

The Effects of Visual and Auditory Feedback on Pain Reduce (시각과 청각되먹임이 통증감소에 미치는 영향)

  • Bae, Young-Sook;Kim, Soon-Hoe;Min, Kyung-Ok
    • Journal of Korean Physical Therapy Science
    • /
    • v.9 no.1
    • /
    • pp.1-8
    • /
    • 2002
  • This study set out to investigate what kind of effects the consistent visual stimuli and verbal and non verbal auditory stimuli have on pain alleviation, as well as to see the influence of joint application of visual and auditory stimuli at the same time on pain alleviation, according to lightness of 50lux and 200lux, ultimately providing basic data in setting up an environment in case of treating pain. The subject were comprised of 30 male and female adults with pain in the neck and back area. The subject were treated in their pain area with Transcutaneous Electrical Nerve Stimulator(TENS) 100HZ for 20 minutes in the research set where each visual, auditory, and joint visual and auditory stimuli was given. For analysis methods, Visual Analogue Scale(VAS) and McGill Pain Questionnaire were adopted to see the changes before and after treatment, and the electrocardiogram, systolic and diastolic pressure, number of heart rate and breathing frequence and endorphin were compared and analyzed using the Wilcoxon singed-rank test. And The Kreskal-walllis test was used to compare the two subgroups from each group. Wilcoxon singed-rank test and the Kreskal-walllis test was used to compare the two subgroups from each group. The results were as follows: 1. The group of 50lux and 200lux were compared given varying degrees of visual stimuli. The group of 200lux showed more reduction in pain points, average systolic and diastolic pressure and average endorphin. 2. The group of verbal and non verbal were compared given varying degrees of auditory stimuli. The group of non-verbal showed more reduction in average systolic and diastolic pressure. 3. The group of 200lux+verbal and 200lux+non verbal were compared given varying degrees of joint visual and auditory stimuli. There was found a statistical significance(p<0.05) in endorphin between the two groups, with more endorphin reduction for 200lux+non verbal group. And there was a statistically significant reduction in VAS and McGill before and after the treatment between the two groups.

  • PDF