• Title/Summary/Keyword: Visual imaging

Search Result 629, Processing Time 0.031 seconds

Calculation of Renal Depth by Conjugate-View Method Using Dual-head Gamma Camera (이중 헤드 감마 카메라를 이용한 Conjugate-View 계수법에 의한 신장 깊이 도출)

  • Kim, Hyun-Mi;Suh, Tae-Suk;Choe, Bo-Young;Chung, Yong-An;Kim, Sung-Hoon;Chung, Soo-Kyo;Lee, Hyoung-Koo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.6
    • /
    • pp.378-388
    • /
    • 2001
  • Purpose: In this study, we developed a new method for the determination of renal depth with anterior and posterior renal scintigrams in a dual-head gamma camera, considering the attenuation factor $e^{-{\mu}x}$ of the conjugate-view method. Material and Method: We developed abdomen and kidney phantoms to perform experiments using Technetium-99m dimercaptosuccinic acid ($^{99m}Tc$-DMSA). The phantom images were obtained by dual-head gamma camera equipped with low-energy, high-resolution, parallel-hole collimators (ICONf, Siemens). The equation was derived from the linear integration of omission ${\gamma}$-ray considering attenuation from the posterior abdomen to the anterior abdomen phantom surface. The program for measurement was developed by Microsoft Visual C++ 6.0. Results : Renal depths of the phantoms were derived from the derived equations and compared with the exact geometrical values. Differences between the measured and the calculated values were the range of 0.1 to 0.7 cm ($0.029{\pm}0.15cm,\;mean{\pm}S.D.$). Conclusion: The present study showed that the use of the derived equations for renal depth measurements, combined with quantitative planar imaging using dual-head gamma camera, could provide more accurate results for individual variation than the conventional method.

  • PDF

Diagnostic Accuracy of Rest T1-201/Stress Tc-99m-MIBI Myocardial SPECT in the Diagnosis of Coronary Artery Disease (휴식 T1-201/부하 Tc-99m MIBI 심근 SPECT의 관상동맥질환 진단 정확성)

  • Yeo, Jeong-Seok;Lee, Dong-Soo;Kang, Keon-Wook;Sohn, Dae-Won;Oh, Byung-Hee;Lee, Myung-Mook;Chung, June-Key;Park, Young-Bae;Lee, Myung-Chul;Seo, Jung-Don;Lee, Young-Woo;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.1
    • /
    • pp.112-117
    • /
    • 1996
  • Objective: Standard stress/rest Tc-99m MIBI and T1-201 myocardial perfusion study have some limitations such as stress/rest image overlap for Tc-99m-MIBI, low energy for T1-201 and long period of study time for two separate studies. Separate acquisition rest T1-201/stress Tc-99m MIBI dual isotope study is a potentially efficient myocardial perfusion imaging protocol that combines the high resolution of Tc-99m for stress perfusion assessment and T1-201 for viability assessment. This study assessed the usefulness and diagnostic accuracy for this new approach. Methods: We tried to evaluate sensitivity and specificity of dual isotope separate acquisition protocol in 67 patients. Immediately after resting T1-201 SPECT data was acquired, dipyridamole stress Tc-99m MIBI myocardial perfusion study was performed. Visual analysis was carried out qualitatively with 0 to 3 scoring system for 17 segments of left ventricle in the reconstructed horizontal long axis and short axis slices. Results: Total study was completed within 3 hours. In angiographic correlation, dual isotope SPECT demonstrated high sensitivity(85%) and in a small group of patients, high specificity was also observed (100%). Conclusion: Combined thallium-201/stress Tc-99m MIBI SPECT displayed similiar diagnostic accuracy to protocol using stress/rest Tc-99m MIBI SPECT. This protocol was completed in shorter period than the previous protocols and therefore enhance laboratory throughput and patients convenience.

  • PDF

EARLY DETECTION OF INITIAL DENTAL CARIES USING A $DIFOTI^{TM}$ (Digital Imaging Fiber-Optic Trans-illumination을 이용한 초기 법랑질 우식병소의 조기 진단)

  • Yeom, Hae-Woong;Yoo, Seung-Hoon;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.587-597
    • /
    • 2004
  • Over the past 20 years, great strides have been made in research regarding the mechanisms involved in the progression of carious lesions, but new equipment and research tools need to be developed to continue these advancements in caries research. Various methods have been applied to reduce the incidence of carious lesions, which have led to a significant decrease in the number of occlusal caries, but a concurrent increase in the proportion of proximal carious lesions. New diagnostic equipment has been developed to detect early stage carious lesions, and these have demonstrated excellent laboratory results and show promise in clinical applications. The research presented here examines the efficacy of the newly developed $DIFOTI^{TM}$ system in detecting proximal carious lesions compared to traditional intraoral exam and bitewing radiography, possible problems or deficiencies of using the system in clinic, possible improvements that can be made to the system, and the efficacy of detecting early, reversible carious lesions that can be remineralized by preventative fluoride applications. The subject pool consisted of 23 grammer school age patients just prior to entering the mixed dentition phase. Each patient was given a thorough oral examination, radiographic examination consisting of bitewing radiographs of the posterior teeth, and $DIFOTI^{TM}$ examination of the anterior and posterior teeth. Each examination was carried out two times by two examiners, and the data were statistically analyzed. The results are as follows: 1. The mean alpha value of reliability test of the visual oral examination was as follows; occlusal surface was 0.8470. mesial surface was 0.6430, distal surface was 0.5727. lingual surface was 0.2807 and distal surface was 0.2339. When the examination was limited to posterior teeth, the mean alpha value was as follows; occlusal surface was 0.8577, distal surface was 0.8211, lingual surface was 0.7728, buccal surface was 0.7152 and mesial surface was 0.6782. 2. The alpha value of reliability test of the radiographic analysis of carious lesions of the occlusal, mesial, and distal surfaces was 0.8500. 3. The alpha value of reliability test of the $DIFOTI^{TM}$ diagnostic analysis of carious lesions of the occlusal, buccal, lingual, mesial, and distal surfaces was determined to be 0.7917. 4. The $DIFOTI^{TM}$ diagnostic system was found to be the most accurate means of detecting occlusal, buccal, and lingual surface carious lesions (p<0.05), while mesial and distal proximal carious lesions were most accurately assessed using bitewing radiography (p<0.05).

  • PDF

The Therapeutic Effect of Postganglionic Nerve Block for Symptomatic Schmorl Nodule: A Retrospective Case Series (증후성 쉬모를 결절에 대한 신경절 이후 신경차단술의 치료 효과: 후향적 증례 분석)

  • Son, In Seok;Hwang, Suk Hyun;Lee, Suk Ha;Kang, Min Seok
    • Journal of Korean Society of Spine Surgery
    • /
    • v.25 no.4
    • /
    • pp.147-153
    • /
    • 2018
  • Study Design: Retrospective case series. Objectives: We retrospectively evaluated the clinical efficacy of postganglionic nerve block in symptomatic Schmorl nodules (SNs). Summary of Literature Review: SNs are common lesions that are often asymptomatic. In certain cases, SNs have been reported to cause severe axial back pain, thereby considerably impacting patients' quality of life. No consensus currently exists on the treatment of symptomatic SNs. Materials and Methods: From October 2015 to October 2017, a total of 21 patients with symptomatic SNs diagnosed by magnetic resonance imaging (MRI) that did not respond to conservative treatment after 4 weeks were included in the study. All patients received postganglionic nerve block. We evaluated effective pain relief (improvement of back pain of more than 50% compared with before the intervention) and functional improvements, assessed by visual analogue scale (VAS) and Oswestry Disability Index scores obtained at 4 hours, 4 weeks, 8 weeks, 3 months, and 6 months after the procedure. Results: Symptomatic SNs were more common at the L2-3 level, and the lower end plate was more commonly involved than the upper end plate. Eighteen of the 21 patients (85.7%) showed effective pain relief, and no deterioration was observed within the followup period. Throughout the follow-up period, the VAS remained significantly improved compared to before the procedure (p<0.05). Complications were not reported in any cases. Conclusions: Postganglionic nerve block for symptomatic SNs that do not respond to conservative treatment is a non-invasive modality for pain relief.

Evaluation of waterlogging tolerance using chlorophyll fluorescence reaction in the seedlings of Korean ginseng (Panax ginseng C. A. Meyer) accessions (엽록소 형광반응을 이용한 인삼 유전자원의 습해 스트레스 평가)

  • Jee, Moo Geun;Hong, Young Ki;Kim, Sun Ick;Park, Yong Chan;Lee, Ka Soon;Jang, Won Suk;Kwon, A Reum;Seong, Bong Jae;Kim, Me-Sun;Cho, Yong-Gu
    • Journal of Plant Biotechnology
    • /
    • v.49 no.3
    • /
    • pp.240-249
    • /
    • 2022
  • Measuring chlorophyll fluorescence (CF) is a useful tool for assessing a plant's ability to tolerate abiotic stresses such as drought, waterlogging and high temperature. Korean ginseng is highly sensitive to water stress in paddy fields. To evaluate the possibility of non-destructively diagnosing waterlogging stress using chlorophyll fluorescence (CF) imaging techniques, we screened 57 ginseng accessions for waterlogging tolerance. To evaluate waterlogging tolerance among the 2-year-old Korean ginseng accessions, we treated ginseng plants with water stress for 25 days. The physiological disorder rate was characterized through visual assessment (an assigned score of 0-5). The physiological disorder rates of Geumjin, Geumsun and GS00-58 were lower than that of other accessions. In contrast, lines GS97-62, GS97-69 and GS98-1-5 were deemed susceptible. Root traits, chlorophyll content and the reduction rates decreased in most ginseng accessions. Further, these metrics were significantly lower in susceptible genotypes compared to resistant ones. All CF parameters showed a positive or negative response to waterlogging stress, and this response continuously increased over the treatment time among the genotypes. The CF parameter Fv/Fm was used to screen the 57 accessions, and the results showed clear differences in Fv/Fm between the susceptible and resistant genotypes. Susceptible genotypes had an especially low Fv/Fm value of less than 0.8, reflecting damage to the reaction center of photosystem II. It is concluded that Fv/Fm can be used as a CF parameter index for screening waterlogging stress tolerance in ginseng genotypes.

Humeral Head Decentralization of Preoperative Magnetic Resonance Images and the Treatment of Shoulder Dislocations in Large to Massive Rotator Cuff Tears in Elderly over 65 Years Old (65세 이상 고령의 회전근 개 대파열 및 광범위 파열에 동반된 견관절 탈구의 치료 및 술 전 자기공명영상의 상완골두 탈중심화)

  • Lee, Bong-Ju;Song, In-Soo;Cha, Kihun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.5
    • /
    • pp.418-426
    • /
    • 2019
  • Purpose: This study analyzed the features of humeral head decentralization in large to massive rotator cuff tears with a shoulder dislocation in the elderly. Moreover, shoulder instability and treatment were reviewed. Materials and Methods: From May 2005 to February 2017, Group A containing 45 cases (45 patients) over 65 years old accompanied by a large or massive rotator cuff tear with a shoulder dislocation and Group B containing 45 cases (45 patients) without a shoulder dislocation were enrolled. The mean ages in Groups A and B were 73.2 and 72.1 years old, and the mean follow-up periods were 30.7 and 31.3 months, respectively. Twenty-one cases (46.7%) in Group A underwent rotator cuff repair, and 8 cases (17.8%) underwent concomitant rotator cuff repair with Bankart repair. Sixteen cases (35.6%) underwent reverse total shoulder arthroplasty for cuff tear arthropathy. 45 cases (100%) in Group B underwent rotator cuff repair. The off-the center and head elevation were measured in the preoperative magnetic resonance imaging (MRI) of Groups A and B. The preoperative and postoperative visual analogue scale (VAS) score, American Shoulder and Elbow Surgeons (ASES) score, and University of California Los Angeles (UCLA) score in Groups A and B were compared. Results: In Groups A and B, the mean off-the centers were posterior 7.41 mm and posterior 2.02 mm (p=0.03), and the mean head elevations were superior 6.66 mm and superior 2.44 mm (p=0.02), respectively. The mean ASES scores of Groups A and B were 32.8 and 33.4 before surgery, and 77.1 (p=0.02) and 78.1 (p=0.02) after surgery (p=0.18), respectively. The mean UCLA scores of Groups A and B were 13.1 and 12.8 before surgery, and 28.9 (p=0.02) and 29.5 (p=0.01) after surgery (p=0.15), respectively. Conclusion: Patients over 65 years old with a shoulder dislocation in large to massive rotator cuff tears had higher off-the center and head elevation on the preoperative MRI than those without a shoulder dislocation. This measurement can help predict preceding shoulder instability. Early rotator cuff repairs should be performed and other treatments, such as Bankart repair and reverse total shoulder arthroplasty, should also be considered.

Generative Adversarial Network-Based Image Conversion Among Different Computed Tomography Protocols and Vendors: Effects on Accuracy and Variability in Quantifying Regional Disease Patterns of Interstitial Lung Disease

  • Hye Jeon Hwang;Hyunjong Kim;Joon Beom Seo;Jong Chul Ye;Gyutaek Oh;Sang Min Lee;Ryoungwoo Jang;Jihye Yun;Namkug Kim;Hee Jun Park;Ho Yun Lee;Soon Ho Yoon;Kyung Eun Shin;Jae Wook Lee;Woocheol Kwon;Joo Sung Sun;Seulgi You;Myung Hee Chung;Bo Mi Gil;Jae-Kwang Lim;Youkyung Lee;Su Jin Hong;Yo Won Choi
    • Korean Journal of Radiology
    • /
    • v.24 no.8
    • /
    • pp.807-820
    • /
    • 2023
  • Objective: To assess whether computed tomography (CT) conversion across different scan parameters and manufacturers using a routable generative adversarial network (RouteGAN) can improve the accuracy and variability in quantifying interstitial lung disease (ILD) using a deep learning-based automated software. Materials and Methods: This study included patients with ILD who underwent thin-section CT. Unmatched CT images obtained using scanners from four manufacturers (vendors A-D), standard- or low-radiation doses, and sharp or medium kernels were classified into groups 1-7 according to acquisition conditions. CT images in groups 2-7 were converted into the target CT style (Group 1: vendor A, standard dose, and sharp kernel) using a RouteGAN. ILD was quantified on original and converted CT images using a deep learning-based software (Aview, Coreline Soft). The accuracy of quantification was analyzed using the dice similarity coefficient (DSC) and pixel-wise overlap accuracy metrics against manual quantification by a radiologist. Five radiologists evaluated quantification accuracy using a 10-point visual scoring system. Results: Three hundred and fifty CT slices from 150 patients (mean age: 67.6 ± 10.7 years; 56 females) were included. The overlap accuracies for quantifying total abnormalities in groups 2-7 improved after CT conversion (original vs. converted: 0.63 vs. 0.68 for DSC, 0.66 vs. 0.70 for pixel-wise recall, and 0.68 vs. 0.73 for pixel-wise precision; P < 0.002 for all). The DSCs of fibrosis score, honeycombing, and reticulation significantly increased after CT conversion (0.32 vs. 0.64, 0.19 vs. 0.47, and 0.23 vs. 0.54, P < 0.002 for all), whereas those of ground-glass opacity, consolidation, and emphysema did not change significantly or decreased slightly. The radiologists' scores were significantly higher (P < 0.001) and less variable on converted CT. Conclusion: CT conversion using a RouteGAN can improve the accuracy and variability of CT images obtained using different scan parameters and manufacturers in deep learning-based quantification of ILD.

The Usefulness of 18F-FDG PET to Differentiate Subtypes of Dementia: The Systematic Review and Meta-Analysis

  • Seunghee Na;Dong Woo Kang;Geon Ha Kim;Ko Woon Kim;Yeshin Kim;Hee-Jin Kim;Kee Hyung Park;Young Ho Park;Gihwan Byeon;Jeewon Suh;Joon Hyun Shin;YongSoo Shim;YoungSoon Yang;Yoo Hyun Um;Seong-il Oh;Sheng-Min Wang;Bora Yoon;Hai-Jeon Yoon;Sun Min Lee;Juyoun Lee;Jin San Lee;Hak Young Rhee;Jae-Sung Lim;Young Hee Jung;Juhee Chin;Yun Jeong Hong;Hyemin Jang;Hongyoon Choi;Miyoung Choi;Jae-Won Jang;Korean Dementia Association
    • Dementia and Neurocognitive Disorders
    • /
    • v.23 no.1
    • /
    • pp.54-66
    • /
    • 2024
  • Background and Purpose: Dementia subtypes, including Alzheimer's dementia (AD), dementia with Lewy bodies (DLB), and frontotemporal dementia (FTD), pose diagnostic challenges. This review examines the effectiveness of 18F-Fluorodeoxyglucose Positron Emission Tomography (18F-FDG PET) in differentiating these subtypes for precise treatment and management. Methods: A systematic review following Preferred Reporting Items for Systematic reviews and Meta-Analyses guidelines was conducted using databases like PubMed and Embase to identify studies on the diagnostic utility of 18F-FDG PET in dementia. The search included studies up to November 16, 2022, focusing on peer-reviewed journals and applying the goldstandard clinical diagnosis for dementia subtypes. Results: From 12,815 articles, 14 were selected for final analysis. For AD versus FTD, the sensitivity was 0.96 (95% confidence interval [CI], 0.88-0.98) and specificity was 0.84 (95% CI, 0.70-0.92). In the case of AD versus DLB, 18F-FDG PET showed a sensitivity of 0.93 (95% CI 0.88-0.98) and specificity of 0.92 (95% CI, 0.70-0.92). Lastly, when differentiating AD from non-AD dementias, the sensitivity was 0.86 (95% CI, 0.80-0.91) and the specificity was 0.88 (95% CI, 0.80-0.91). The studies mostly used case-control designs with visual and quantitative assessments. Conclusions: 18F-FDG PET exhibits high sensitivity and specificity in differentiating dementia subtypes, particularly AD, FTD, and DLB. This method, while not a standalone diagnostic tool, significantly enhances diagnostic accuracy in uncertain cases, complementing clinical assessments and structural imaging.

The Photography as Technological Aesthetics (데크놀로지 미학으로서의 사진)

  • Jin, Dong-Sun
    • Journal of Science of Art and Design
    • /
    • v.11
    • /
    • pp.221-249
    • /
    • 2007
  • Today, photography is facing to the crisis of identity and dilemma of ontology from the digital imaging process in the new technology form. It is very important points to say rethinking of the traditional photographic medium, that has changed the way we view the world and ourselves is perhaps an understatement and that photography has transformed our essential understanding of reality. Now, no longer are photographic images regarded as the true automatic recording, innocent evidence and the mirror to the reality. Rather, photography constructs the world for our entertainment, helping to create the comforting illusions by which we live. The recognition that photographs are not constructions and reflections of reality, is the basis for the actual presence within the contemporary photographic world. It is shock. This thesis's aim is to look for the problems of photographic identity and ontological crisis that is controlling and regulating digital photographic imagery, allowing the reproduction of the electronic simulations era. Photography loses its special aesthetic status and becomes no more true information and, exclusively evidence by traditional film and paper that appeared both as a technological accuracy and as a medium-specific aesthetic. The result, photography is facing two crises, one is the photographic ontology(the introduction of computerized digital images) and the other is photographic epistemology(having to do broader changes in ethics, knowledge and culture). Taken together, these crises apparently threaten us with the death of photography, with the 'end' of photography and the culture it sustains. The thesis's meaning is to look into the dilemma of photography's ontology and epistemology, especially, automatical index and digital codes from its origin, meaning, and identity as the technological medium. Thus, in particular, thesis focuses on the analog imagery presence, from the nature in the material world, and the digital imagery presence from the cultural situations in our society. And also thesis's aim is to examine the main issues of the history of photography has been concentrated on the ontological arguments since the discovery of photography in 1839. Photography has never been only one static technology form. Rather, its nearly two centuries of technological development have been marked by numerous, competing of technological innovation and self revolution from the dual aspects. This thesis examines recent account of photography by the analysis of the medium's concept, meaning, identity between film base image and digital base image from the aspects of photographic ontology and epistemology. Thus, the structure of thesis is fairy straightforward to examine what appear to be two opposing view of photographic conditions and ontological situations. Thesis' view contrasts that figure out the value of photography according to its fundamental characteristic as a medium. Also, it seeks a possible solution to the dilemma of photographic ontology through the medium's origin from the early years of the nineteenth century to the raising questions about the different meaning(analog/digital) of photography, now. Finally, this thesis emphasizes and concludes that the photographic ontological crisis reflects to the paradoxical dynamic structure, that unsolved the origins of the medium, itself. Moreover, even photography is not single identity of the photographic ontology, and also can not be understood as having a static identity or singular status from the dynamic field of technologies, practices, and images.

  • PDF