• Title/Summary/Keyword: Visible Image

Search Result 502, Processing Time 0.027 seconds

Visibility of the mandibular canal and the mental foramen in panoramic radiography (파노라마 방사선사진에서 하악관과 이공의 관찰되는 정도)

  • Jeong Seon-Jin;Choi Eui-Hwan;Kim Jae-Duk
    • Imaging Science in Dentistry
    • /
    • v.31 no.3
    • /
    • pp.153-158
    • /
    • 2001
  • Purpose : To determine the head position that the superior border of the mandibular canal as well as mental foramen can be more clearly visualized in panoramic radiography Materials and Methods : Ten dry mandibles were radiographed bilaterally using PM 2002 CC panoramic machine. A 20 mm thick aluminium filter was added to the slit collimator to obtain radiographs with acceptable density. The specimens were tilted by 2, 4, 6, 8, and 10 degrees downward with and without radiopaque markers. Radiopaque markers were inserted into the mandibular canals and the mental canals of each side of the specimens to serve as reference image when assessing the radiographs. The visibility of the mandibular canal and the mental foramen was estimated by 4 observers on all radiographs. The obtained results were analyzed statistically. Results: Mandibular canals were significantly more clearly visible in the radiographs with 4 and 6 degree downward position on both sides (P<0.05). Mental foramens were significantly more clearly visible in the radiographs with 4, 6, and 8 degree downward on right side and 6 degree downward on left side (P<0.05). There was not significant difference between right and left sides. Conclusion: Panoramic radiographs with 4 to 6 degree downward tilting could be valuable in locating the mandibular canal as well as the mental foramen.

  • PDF

Sea fog detection near Korea peninsula by using GMS-5 Satellite Data(A case study)

  • Chung, Hyo-Sang;Hwang, Byong-Jun;Kim, Young-Haw;Son, Eun-Ha
    • Proceedings of the KSRS Conference
    • /
    • 1999.11a
    • /
    • pp.214-218
    • /
    • 1999
  • The aim of our study is to develop new algorism for sea fog detection by using Geostational Meteorological Satellite-5(GMS-5) and suggest the techniques of its continuous detection. So as to detect daytime sea fog/stratus(00UTC, May 10, 1999), visible accumulated histogram method and surface albedo method are used. The characteristic value during daytime showed A(min) > 20% and DA < 10% when visble accumulated histogram method was applied. And the sea fog region which detected is of similarity in composite image and surface albedo method. In case of nighttime sea fog(18UTC, May 10, 1999), infrared accumulated histogram method and maximum brightness temperature method are used, respectively. Maximum brightness temperature method(T_max method) detected sea fog better than IR accumulated histogram method. In case of T_max method, when infrared value is larger than T_max, fog is detected, where T_max is an unique value, maximum infrared value in each pixel during one month. Then T_max is beneath 700hpa temperature of GDAPS(Global Data Assimilation and Prediction System). Sea fog region which detected by T_max method was similar to the result of National Oceanic and Atmosheric Administration/Advanced Very High Resolution Radiometer (NOAA/AVHRR) DCD(Dual Channel Difference). But inland visibility and relative humidity didn't always agreed well.

  • PDF

Fast Lamp Pairing-based Vehicle Detection Robust to Atypical and Turn Signal Lamps at Night

  • Jeong, Kyeong Min;Song, Byung Cheol
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.6 no.4
    • /
    • pp.269-275
    • /
    • 2017
  • Automatic vehicle detection is a very important function for autonomous vehicles. Conventional vehicle detection approaches are based on visible-light images obtained from cameras mounted on a vehicle in the daytime. However, unlike daytime, a visible-light image is generally dark at night, and the contrast is low, which makes it difficult to recognize a vehicle. As a feature point that can be used even in the low light conditions of nighttime, the rear lamp is virtually unique. However, conventional rear lamp-based detection methods seldom cope with atypical lamps, such as LED lamps, or flashing turn signals. In this paper, we detect atypical lamps by blurring the lamp area with a low pass filter (LPF) to make out the lamp shape. We also propose to detect flickering of the turn signal lamp in a manner such that the lamp area is vertically projected, and the maximum difference of two paired lamps is examined. Experimental results show that the proposed algorithm has a higher F-measure value of 0.24 than the conventional lamp pairing-based detection methods, on average. In addition, the proposed algorithm shows a fast processing time of 6.4 ms per frame, which verifies real-time performance of the proposed algorithm.

Conceptual Design of Laser Plasma-based Soft X-ray Microscope system for Biomedical Application (레이저 플라즈마 기반의 생물의료용 연 X-선 현미경 설계)

  • 김경우;윤권하
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.690-693
    • /
    • 2003
  • Soft x-ray microscopy provides a unique set of capabilities in-between those of visible light and electron microscopy. It has long been recognized that nature provides a 'water window' spectral region between the K shell x-ray absorption edges of carbon (~290eV) and oxygen (~540eV), where organic materials show strong absorption and phase contrast, while water is relatively non-absorbing. This enables imaging of hydrated biological specimens that are several microns thick with high intrinsic contrast using x-rays with a wavelength of 2.3~4.4nm. Soft X-ray microscopy is therefore well suited to the study of specimens like single biological cells. The most direct advantage of X-ray microscope is their high spatial resolution when compared with visible light microscopes, combined with an ability to image hydrated specimens that are several microns with a minimum of preparation. Our study describes the conceptual design of soft x-ray microscope system based on a laser-based source for biomedical application with high resolution ($\leq$50nm) and short exposure time ($\leq$30sec).

  • PDF

Tomographic Interpretations of Visible Emissions from the Axisymmetric Partially Premixed Flames (단층진단법을 이용한 축대칭 부분예혼합 화염의 자발광 스펙트럼 해석에 관한 연구)

  • Ha, Kwang-Soon;Choi, Sang-Min
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.6
    • /
    • pp.769-776
    • /
    • 2000
  • Visible spectral characteristics of cross-sectional emissions from a partially premixed methane/air and propane/air flames have been investigated. An optical train with a two-axis scanning mirror system was used to record line-of-sight emission spectra from 354nm to 618nm, and inversion technique was adapted to obtain cross-sectional emission spectra. By analyzing the reconstructed emission spectra, cross-sectional intensities of CH and $C_2$ radicals were separated from the background emissions. The blue flame edge and yellow flame edge were also obtained by image processing technique for edge detection with color photograph of flame. These edges were compared with radial distributions of CH, $C_2$ radicals and background emissions. The CH radicals were observed at blue flame edge. The background emissions were generated by soot precursor at upstream of flame and by soot at downstream of flame. The $C_2$ radicals in propane/air flame were observed more than those in methane/air flame.

Synthesis and Characterization of Soluble Polyaniline and TiO2 Composite

  • Kim, Byoung-Ju;Kang, Kwang-Sun
    • Current Photovoltaic Research
    • /
    • v.3 no.3
    • /
    • pp.71-74
    • /
    • 2015
  • Soluble polyaniline was synthesized by attaching titanium isoproxide ($Ti(OPr)_4$) to the amine group of the aniline. Approximately 1 to 1 molar ratio of aniline and $Ti(OPr)_4$ was mixed and polymerized with ammonium persulfate. The FTIR result showed clear difference between $TiO_2$-aniline composite ($TiO_2An$) and $TiO_2$-polyaniline composite ($TiO_2PAn$). Although the $TiO_2An$ had negligible UV-visible absorption, the $TiO_2PAn$ showed strong absorption in the UV-visible region. Photoluminescence (PL) peaks of $TiO_2An$ were shifted toward red with the reduction of the excitation energy, which could be due to the multiple emission centers. The luminescence peak shift stopped at 501 nm. The PL spectra of $TiO_2PAn$ exhibited three emission peaks at 2.88 eV (430 nm), 2.48 eV (501 nm) and 2.22 eV (558 nm). The new emission center (2.22 eV) was observed after polymerization. Field emission scanning electron microscope image showed crack-free composite film.

Park-Weir Excision for Flaring Alar Correction (넓어진 콧방울의 교정을 위한 Park-Weir 절제술)

  • Han, Sung-Bum;Park, Beyoung-Yun
    • Archives of Plastic Surgery
    • /
    • v.38 no.5
    • /
    • pp.674-678
    • /
    • 2011
  • Purpose: Straight closure line of classic Weir excision leaves visible scars and makes it difficult to precisely approximate resection margins. Hence this study introduces Park-Weir excision that effectively reduces alar width with minimal alar rim scar by 3-dimensional zigzag incision and properly controls the approximation of edges. Methods: From 2008 to 2010, 14 patients underwent Park-Weir excision, crossed wedge excision on alar rim not exceeding 5 mm in width. Each patient was photographed in the same position. Alar width and columellar height against intercanthal distance was compared preoperatively and postoperatively, using image analysis software. Results: Five patients were female and nine were male. Average follow up period was 8 month. Alar width was reduced by 50.50% to 45.96%, original alar width reduced by 8.98% without significant changes in columellar height which was reduced by 0.39%. No visible scar was reported during outpatient follow-up. Conclusion: Park-Weir excision effectively reduces alar width and corrects the flaring of alar without affecting the columellar height. Zigzag incision of Park-Weir excision leaves aesthetically more pleasant scar than straight single incision of classical Weir excision.

Asymmetric Metal-Semiconductor-Metal Al0.24Ga0.76N UV Sensors with Surface Passivation Effect Under Local Joule Heating

  • Byeong-Jun Park;Sung-Ho Hahm
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.6
    • /
    • pp.425-431
    • /
    • 2023
  • An asymmetric metal-semiconductor-metal Al0.24Ga0.76N ultraviolet (UV) sensor was fabricated, and the effects of local Joule heating were investigated. After dielectric breakdown, the current density under a reverse bias of 2.0 V was 1.1×10-9 A/cm2, significantly lower than 1.2×10-8 A/cm2 before dielectric breakdown; moreover, the Schottky behavior of the Ti/Al/Ni/Au electrode changed to ohmic behavior under forward bias. The UV-to-visible rejection ratio (UVRR) under a reverse bias of 7.0 V before dielectric breakdown was 87; however, this UVRR significantly increased to 578, in addition to providing highly reliable responsivity. Transmission electron microscopy revealed interdiffusion between adjacent layers, with nitrogen vacancies possibly formed owing to local Joule heating at the AlGaN/Ti/Al/Ni/Au interfaces. X-ray photoelectron microscopy results revealed decreases in the peak intensities of the O 1s binding energies associated with the Ga-O bond and OH-, which act as electron-trapping states on the AlGaN surface. The reduction in dark current owing to the proposed local heating method is expected to increase the sensing performance of UV optoelectronic integrated devices, such as active-pixel UV image sensors.

Color change of dried laver according to heating conditions (가열조건에 따른 마른김의 색택 변화 연구)

  • Kyoung-In Lee;Geun-Jik Lee;Young-Seung Yoon
    • Journal of Marine Bioscience and Biotechnology
    • /
    • v.16 no.1
    • /
    • pp.19-25
    • /
    • 2024
  • To verify the color change in dried laver postproduction during the heating process, chromaticity elements were compared via a spectrophotometer across various heating conditions within the visible light spectrum. In general, the moisture reduction rate increased with rising temperature and time. Surface image comparisons revealed an expanded area of light reflection on the heat-treated dried laver sample due to surface roughening from shrinkage. No statistically significant differences in chromaticity values were observed in the measurements of brightness (L*), redness (a*), and yellowness (b*). Reflectance spectrum measurements in the visible light region confirmed high reflectance under red wavelength conditions. In particular, a significant increase in reflectance at 700 nm compared with untreated samples was noted. The correlation between the increase in 700 nm reflectance of dried laver samples and heating conditions ranged from 0.7471 to 0.7793, suggesting its potential use as an indicator for comparing color changes in dried laver based on heating conditions.

A Real-Time Control of SCARA Robot Based Image Feedback (이미지 피드백에 의한 스카라 로봇의 실시간 제어)

  • Lee, Woo-Song;Koo, Young-Mok;Shim, Hyun-Seok;Lee, Sang-Hoon;Kim, Dong-Yeop
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.17 no.2
    • /
    • pp.54-60
    • /
    • 2014
  • The equipment of SCARA robot in processing and assembly lines has rapidly increased. In order to achieve high productivity and flexibility, it becomes very important to develop the visual feedback control system with Off-Line Programming System(OLPS). We can save much efforts and time in adjusting robots to newly defined workcells by using OLPS. A proposed visual calibration scheme is based on position-based visual feedback. The calibration program firstly generates predicted images of objects in an assumed end-effector position. The process to generate predicted images consists of projection to screen-coordinates, visible range test, and construction of simple silhouette figures. Then, camera images acquired are compared with predicted ones for updating position and orientation data. Computation of error is very simple because the scheme is based on perspective projection, which can be also expanded to experimental results. Computation time can be extremely reduced because the proposed method does not requirethe precise calculation of tree-dimensional object data and image Jacobian.