• 제목/요약/키워드: Viscous solution

검색결과 257건 처리시간 0.028초

반무한 연속고가교에 대한 점성경계 설정속도의 간편식 (An Approximation Expression of Wave Velocity of Viscous Boundary for Infinitely tong Elevated Bridge)

  • 이상훈;엔도타카오;이원철
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2007년도 정기총회 및 학술발표대회
    • /
    • pp.140-143
    • /
    • 2007
  • A continuing elevated bridge is replaced with mass-spring system model, and a part of the bridge is cut out as an analytical area. A viscous boundary is installed at both ends, and dynamic analyses are carried out changing the wave velocity of the viscous boundary, The result is compared with a result of a very long model corresponding to the solution with infinite length. A wave velocity is chosen so that the good performance of a viscous boundary is exhibited. The parametric analyses are carried out changing the model of various structural properties, and an approximation expression is suggested to obtain the wave velocity easily for setting a viscous boundary.

  • PDF

FINITE ELEMENT SCHEME FOR THE VISCOUS CAHN-HILLIARD EQUATION WITH A NONCONSTANT GRADIENT ENERGY COEFFICIENT

  • CHOO S. M.;KIM Y. H.
    • Journal of applied mathematics & informatics
    • /
    • 제19권1_2호
    • /
    • pp.385-395
    • /
    • 2005
  • A finite element scheme is considered for the viscous Cahn-Hilliard equation with the nonconstant gradient energy coefficient. The scheme inherits energy decay property and mass conservation as for the classical solution. We obtain the corresponding error estimate using the extended Lax-Richtmyer equivalence theorem.

Development of Viscous Boundary Conditions in an Immersed Cartesian Grid Framework

  • Lee, Jae-Doo
    • Journal of Ship and Ocean Technology
    • /
    • 제10권3호
    • /
    • pp.1-16
    • /
    • 2006
  • Despite the high cost of memory and CPU time required to resolve the boundary layer, a viscous unstructured grid solver has many advantages over a structured grid solver such as the convenience in automated grid generation and vortex capturing by solution adaption. In present study, an unstructured Cartesian grid solver is developed on the basis of the existing Euler solver, NASCART-GT. Instead of cut-cell approach, immersed boundary approach is applied with ghost cell boundary condition, which can be easily applied to a moving grid solver. The standard $k-{\varepsilon}$ model by Launder and Spalding is employed for the turbulence modeling, and a new wall function approach is devised for the unstructured Cartesian grid solver. Developed approach is validated and the efficiency of the developed boundary condition is tested in 2-D flow field around a flat plate, NACA0012 airfoil, and axisymmetric hemispheroid.

마이크로 PTV 기법을 이용한 미세채널 내부 계면의 electrokinetic 효과 해석 (Micro-PIV Measurements of interfacial electrokinetic effects in a microchannel)

  • 김국배;이상준
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2002년도 추계학술대회 논문집
    • /
    • pp.49-50
    • /
    • 2002
  • In micro-channels, the electro-viscous effect is caused by the electrical double layer on pressure-driven liquid flow. Velocity fields of flow inside micro-channels were measured using micro-PIV system for investigating the electro-viscous effect. De-ionized water and aqueous NaCl solutions with four different concentrations were used as working fluid in a PDMS micro-channel of $100{\mu}m$ width and $66{\mu}m$ height. The pressure gradient, dP/dx, was determined from the pre-determined input flow rate Q of syringe pump. The mean velocity $u_m$ used for calculating Reynolds number was obtained from the PIV velocity field data. These are used to plot the pressure gradient as a function of Reynolds numbers. The pressure gradient far lower concentration solution $(10^{-5}\;M)$ was higher than that for the higher concentration solution. The increase of flow resistance was about $30\%\;and\;37.5\%$ at Re=0.02 and 0.06, respectively.

  • PDF

상사해(相似解) 및 수치해를 이용한 점성원반 붕괴시 원반 구조 이해 (UNDERSTANDING OF DISK STRUCTURE DURING THE COLLAPSE OF THE VISCOUS DISK USING SELF-SIMILAR AND NUMERICAL SOLUTIONS)

  • 유계화
    • 천문학논총
    • /
    • 제20권1호
    • /
    • pp.37-42
    • /
    • 2005
  • The problem for the collapse of isothermal and rotational self-gravitational viscous disk is considered. We derive self-similar solutions for the cases in the inner and outer regions of the self-gravitational viscous disk. We show that surface density depends on ${\sigma}_0/r$ in the outer region of the disk using a slow accretion approximation. The ratio of a modified viscous parameter in the outer region of the disk to that in the inner region is 0.042. We resorted to numerical solutions of governing equations of the self-gravitational disk to find out profiles of ${\sigma}$, u and ${\upsilon}$ in terms of x. Their profiles were rapidly changed around the innermost region of the self-gravitational disk. It indicates that a new object was formed in the most inner region of the disk.

상피세포성장인자를 함유한 동결건조-재분산 리포좀의 입도분포 및 봉입률 (Size Distribution Characteristics and Entrapment Efficiency of Dried-Reconstituted Liposomes Containing Epidermal Growth Factor)

  • 김희준;유성운;최영욱
    • 약학회지
    • /
    • 제40권6호
    • /
    • pp.646-652
    • /
    • 1996
  • Epidermal Growth Factor (EGF), discovered by Stanley Cohen in 1960, has a potential healing effect for wounds and bums. Considering wound care, in order to avoid physical stress at the wound surface and efficiently apply EGF, the need for viscous spraying solutions was essential. Viscous spraying solutions containing EGF were prepared by utilizing viscosity-building polymer, poloxamer 407, and by introducing liposome systems. On the other hand, EGF is purified on reverse HPLC gradient program with the mobile solvent of acetonitrile. It is necessary to observe liposomal EGF changes as the acetonitrile contents varied in order to introduce liposome systems at the step of EGF solution (at the time of EGF purifying). By evaluating the size distribution and entrapment efficiency of EGF liposome, it was possible to detemine the limit contents of acetonitrile and establish the optimal conditions for solution formulations. It has been revealed that, as the acetonitrile content increases, mean diameter of EGF liposomes increased and the width of size distribution tends to decrease. The limit contents of acetonitrile were 10%, since there was little difference to the acetonitrile free liposomes.

  • PDF

안정적이고 이방성한 빙결 모델링을 위한 암시적 비압축성 유체와 얼음 입자간의 상호작용 기법 (Stable Anisotropic Freezing Modeling Technique Using the Interaction between IISPH Fluids and Ice Particles)

  • 김종현
    • 한국컴퓨터그래픽스학회논문지
    • /
    • 제26권5호
    • /
    • pp.1-13
    • /
    • 2020
  • 본 논문에서는 흐르는 물에 의해 빙결 시뮬레이션 되어 방향성이 있는 얼음 형태를 안정적으로 모델링 할 수 있는 새로운 방법을 제시한다. 제안하는 얼음 모델링 프레임워크는 빙결 시뮬레이션에서 중요한 얼음의 성장 방향에 점성이 있는 유체의 흐름을 고려한다. 물 시뮬레이션 해법은 암시적 비압축성 유체 시뮬레이션에 새로운 점성 기법을 적용한 방법을 이용하고, 얼음의 방향과 글레이즈(Glaze) 효과는 제안하는 비등방성한 빙결 해법을 이용한다. 물 입자가 얼음 입자로 상태변화하는 조건은 습도와 물의 흐름에 따른 새로운 에너지 함수에 따라 계산된다. 습도는 오브젝트 표면의 가상 수막(Virtual water film)으로 근사되며, 유체의 흐름은 얼음의 성장 방향을 가이드하기 위해 우리의 비등방성한 빙결 해법에 통합된다. 결과적으로 점성이 있는 물의 흐름 방향에 따라 글레이즈와 방향성 있는 빙결 시뮬레이션 결과를 안정적으로 보여준다.

단자유도 건물에 설치된 마찰감쇠기의 등가점성감쇠비 (Equivalent Viscous Damping Ratio of a Friction Damper Installed in a SDOF Building)

  • 성지영;민경원
    • 한국전산구조공학회논문집
    • /
    • 제23권2호
    • /
    • pp.199-208
    • /
    • 2010
  • 건물에 설치된 마찰감쇠기는 외력의 크기에 따라 정지와 운동의 상태를 반복하여 외부 입력에너지를 소산시키기 때문에 외력과 응답관계가 비선형이다. 마찰감쇠기가 설치된 단자유도 건물은 마찰감쇠기외에 점성감쇠가 동시에 존재하므로 해석적인 정해를 구하기가 어렵다. 본 연구에서는 첫째, 점성과 마찰감쇠가 있는 단자유도계 건물의 자유진동 정해를 통하여 변위응답과 가속도 응답특성을 분석하였다. 둘째, 자유진동의 경우 응답이 멈출 때까지 소산에너지식을 이용하여 등가점성감쇠비를 구하였다. 셋째, 조화가진 일 때는 수치해석을 통하여 마찰력비 $F_r$에 따른 응답 특성을 알아보았다. 넷째, 조화가진의 경우 에너지 균형식을 바탕으로 등가점성감쇠비를 유도하였다. 등가점성감쇠비는 변위응답비의 영향을 받으므로 응답을 알아야만 구할 수 있다. 건물 응답의 진동수 특성은 협소영역(narrow band)이므로 고유진동수에 의해 지배된다고 가정하여 등가점성감쇠비를 구하였다. 마지막으로, 유도한 자유진동과 조화가진의 등가점성감쇠비를 이용한 등가선형운동방정식의 해를 비선형 수치해석 한 결과와 비교하여 검증하였다.

알콜 탈수법에 의한 Mn-Zn Ferrite 분체 제조시 pH의 영향 (Effect of pH on the Preparation of Manganese Zinc Ferrite Powder by Alcoholic Dehydration of Citrate/formate Solution)

  • 김창범;신효순;이대희;김창현;이병교
    • 한국세라믹학회지
    • /
    • 제32권10호
    • /
    • pp.1123-1130
    • /
    • 1995
  • In the preparation of manganese zinc ferrite powders by alcoholic dehydration of citrate/formate solution. The effect of pH change on precipitation was investigated. The pH range for obtaining stable precipitates was studied. The glassy phase was obtained when the pH value of solution is higher than 5, and the formation mechanism of glassy phase was suggested. Below pH 5, the stable precipitates were formed, and the optimal pH was 2. Formation of glassy phase was accounted for the change of surface charge by pH change. The change of surface charge is caused by the interparticular agglomeration. The precipitate was redissolved into the water on the surface of precipitate itself and through the polymerization, it agglomerated. This mechanism is tought to be similar to that of viscous flow.

  • PDF

진동하는 2차원 날개 단면 주위에 대한 점성 유동장 계산( Part 2. 동적실속이 발생하는 경우 ) (Computation of Viscous Flows around a Two-dimensional Oscillating Airfoil ( Part 2. with Dynamic Stall ))

  • 이평국;김형태
    • 대한조선학회논문집
    • /
    • 제44권1호
    • /
    • pp.16-25
    • /
    • 2007
  • Studies of unsteady-airfoil flows have been motivated mostly by efforts to avoid. or reduce such undesirable effects as flutter, noise and vibrations, dynamic stall. In this paper, we carry out a computational study of viscous flows around a two-dimensional oscillating airfoil to investigate unsteady effects in these important and challenging flows. A fully implicit incompressible RANS solver has been used for calculating unsteady viscous flows around an airfoil. The cell-centered End order finite volume method is utilized to discretize governing equations. in order to ease the flow computation for fluid region changing in time, improve the qualify of solution and simplify the grid generation for an oscillating airfoil flow, the computational method adopts a moving and deforming grid generation technique based on the multi-block grid topology. The numerical method is applied for calculating viscous flows of an oscillating NACA 0012 in uniform flow. The computational results are compared with available experimental data. Computed results are compared with experimental data and flow characteristics of the experiment are reproduced well In the computed results.