• 제목/요약/키워드: Viscous damper

검색결과 197건 처리시간 0.021초

Cable vibration control with internal and external dampers: Theoretical analysis and field test validation

  • Di, Fangdian;Sun, Limin;Chen, Lin
    • Smart Structures and Systems
    • /
    • 제26권5호
    • /
    • pp.575-589
    • /
    • 2020
  • For vibration control of stay cables in cable-stayed bridges, viscous dampers are frequently used, and they are regularly installed between the cable and the bridge deck. In practice, neoprene rubber bushings (or of other types) are also widely installed inside the cable guide pipe, mainly for reducing the bending stresses of the cable near its anchorages. Therefore, it is important to understand the effect of the bushings on the performance of the external damper. Besides, for long cables, external dampers installed at a single position near a cable end can no longer provide enough damping due to the sag effect and the limited installation distance. It is thus of interest to improve cable damping by additionally installing dampers inside the guide pipe. This paper hence studies the combined effects of an external damper and an internal damper (which can also model the bushings) on a stay cable. The internal damper is assumed to be a High Damping Rubber (HDR) damper, and the external damper is considered to be a viscous damper with intrinsic stiffness, and the cable sag is also considered. Both the cases when the two dampers are installed close to one cable end and respectively close to the two cable ends are studied. Asymptotic design formulas are derived for both cases considering that the dampers are close to the cable ends. It is shown that when the two dampers are placed close to different cable ends, their combined damping effects are approximately the sum of their separate contributions, regardless of small cable sag and damper intrinsic stiffness. When the two dampers are installed close to the same end, maximum damping that can be achieved by the external damper is generally degraded, regardless of properties of the HDR damper. Field tests on an existing cable-stayed bridge have further validated the influence of the internal damper on the performance of the external damper. The results suggest that the HDR is optimally placed in the guide pipe of the cable-pylon anchorage when installing viscous dampers at one position is insufficient. When an HDR damper or the bushing has to be installed near the external damper, their combined damping effects need to be evaluated using the presented methods.

Toggle 시스템을 이용한 구조물의 진동제어 (Vibration Control of Structure Using the Toggle System)

  • 황재승;송진규;강경수;윤태호
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 춘계 학술발표회논문집
    • /
    • pp.491-498
    • /
    • 2003
  • The purpose of this study is to analyze the geometric nonlinearity of a toggle system and to evaluate the vibration control performance when the toggle system with a viscous damper was applied to a structure. Numerical analysis shows that the relative displacement of the structure can be amplified by amplification mechanism of the toggle system and the capacity of the damper can be reduced without the loss of vibration control performance. It is also observed that the geometric nolinearity of toggle system using the linear viscous damper has little effect on the performance.

  • PDF

Optimum design of viscous dampers to prevent pounding of adjacent structures

  • Karabork, Turan;Aydin, Ersin
    • Earthquakes and Structures
    • /
    • 제16권4호
    • /
    • pp.437-453
    • /
    • 2019
  • This study investigates a new optimal placement method for viscous dampers between structures in order to prevent pounding of adjacent structures with different dynamic characteristics under earthquake effects. A relative displacement spectrum is developed in two single degree of freedom system to reveal the critical period ratios for the most risky scenario of collision using El Centro earthquake record (NS). Three different types of viscous damper design, which are classical, stair and X-diagonal model, are considered to prevent pounding on two adjacent building models. The objective function is minimized under the upper and lower limits of the damping coefficient of the damper and a target modal damping ratio. A new algorithm including time history analyses and numerical optimization methods is proposed to find the optimal dampers placement. The proposed design method is tested on two 12-storey adjacent building models. The effects of the type of damper placement on structural models, the critical period ratios of adjacent structures, the permissible relative displacement limit, the mode behavior and the upper limit of damper are investigated in detail. The results of the analyzes show that the proposed method can be used as an effective means of finding the optimum amount and location of the dampers and eliminating the risk of pounding.

Experimental calibration of forward and inverse neural networks for rotary type magnetorheological damper

  • Bhowmik, Subrata;Weber, Felix;Hogsberg, Jan
    • Structural Engineering and Mechanics
    • /
    • 제46권5호
    • /
    • pp.673-693
    • /
    • 2013
  • This paper presents a systematic design and training procedure for the feed-forward back-propagation neural network (NN) modeling of both forward and inverse behavior of a rotary magnetorheological (MR) damper based on experimental data. For the forward damper model, with damper force as output, an optimization procedure demonstrates accurate training of the NN architecture with only current and velocity as input states. For the inverse damper model, with current as output, the absolute value of velocity and force are used as input states to avoid negative current spikes when tracking a desired damper force. The forward and inverse damper models are trained and validated experimentally, combining a limited number of harmonic displacement records, and constant and half-sinusoidal current records. In general the validation shows accurate results for both forward and inverse damper models, where the observed modeling errors for the inverse model can be related to knocking effects in the measured force due to the bearing plays between hydraulic piston and MR damper rod. Finally, the validated models are used to emulate pure viscous damping. Comparison of numerical and experimental results demonstrates good agreement in the post-yield region of the MR damper, while the main error of the inverse NN occurs in the pre-yield region where the inverse NN overestimates the current to track the desired viscous force.

Seismic analysis of 3-D two adjacent buildings connected by viscous dampers with effect of underneath different soil kinds

  • Farghaly, Ahmed Abdelraheem
    • Smart Structures and Systems
    • /
    • 제15권5호
    • /
    • pp.1293-1309
    • /
    • 2015
  • 3D two adjacent buildings with different heights founded in different kinds of soil connected with viscous dampers groups, with especial arrangement in plane, were investigated. Soil structure interaction for three different kinds of soil (stiff, medium and soft) were modeled as 3D Winkler model to give the realistic behavior of adjacent buildings connected with viscous dampers under various earthquake excitations taking in the account the effect of different kinds of soil beneath the buildings, using SAP2000n to model the whole system. A range of soil properties and soil damping characteristics are chosen which gives broad picture of connected structures system behavior resulted from the influence soil-structure interaction. Its conclusion that the response of connected structures system founded on soft soil are more critical than those founded on stiff soil. The behavior of connected structures is different from those with fixed base bigger by nearly 20%, and the efficiency of viscous dampers connecting the two adjacent buildings is reduced by nearly 25% less than those founded on stiff soil.

Full-scale test of dampers for stay cable vibration mitigation and improvement measures

  • Zhou, Haijun;Xiang, Ning;Huang, Xigui;Sun, Limin;Xing, Feng;Zhou, Rui
    • Structural Monitoring and Maintenance
    • /
    • 제5권4호
    • /
    • pp.489-506
    • /
    • 2018
  • This paper reported test of full-scale cables attached with four types of dampers: viscous damper, passive Magneto-Rheological (MR) damper, friction damper and High Damping Rubber (HDR) damper. The logarithmic decrements of the cable with attached dampers were calculated from free vibration time history. The efficiency ratios of the mean damping ratios of the tested four dampers to theoretical maximum damping ratio were derived, which was very important for practical damper design and parameter optimization. Non-ideal factors affecting damper performance were discussed based on the test results. The effects of concentrated mass and negative stiffness were discussed in detail and compared theoretically. Approximate formulations were derived and verified using numerical solutions. The critical values for non-dimensional concentrated mass coefficient and negative stiffness were identified. Efficiency ratios were approximately 0.6, 0.6, and 0.3 for the viscous damper, passive MR damper and HDR damper, respectively. The efficiency ratio for the friction damper was between 0-1.0. The effects of concentrated mass and negative stiffness on cable damping were positive as both could increase damping ratio; the concentrated mass was more effective than negative stiffness for higher vibration modes.

단자유도 건물에 설치된 마찰감쇠기의 등가점성감쇠비 (Equivalent Viscous Damping Ratio of a Friction Damper Installed in a SDOF Building)

  • 성지영;민경원
    • 한국전산구조공학회논문집
    • /
    • 제23권2호
    • /
    • pp.199-208
    • /
    • 2010
  • 건물에 설치된 마찰감쇠기는 외력의 크기에 따라 정지와 운동의 상태를 반복하여 외부 입력에너지를 소산시키기 때문에 외력과 응답관계가 비선형이다. 마찰감쇠기가 설치된 단자유도 건물은 마찰감쇠기외에 점성감쇠가 동시에 존재하므로 해석적인 정해를 구하기가 어렵다. 본 연구에서는 첫째, 점성과 마찰감쇠가 있는 단자유도계 건물의 자유진동 정해를 통하여 변위응답과 가속도 응답특성을 분석하였다. 둘째, 자유진동의 경우 응답이 멈출 때까지 소산에너지식을 이용하여 등가점성감쇠비를 구하였다. 셋째, 조화가진 일 때는 수치해석을 통하여 마찰력비 $F_r$에 따른 응답 특성을 알아보았다. 넷째, 조화가진의 경우 에너지 균형식을 바탕으로 등가점성감쇠비를 유도하였다. 등가점성감쇠비는 변위응답비의 영향을 받으므로 응답을 알아야만 구할 수 있다. 건물 응답의 진동수 특성은 협소영역(narrow band)이므로 고유진동수에 의해 지배된다고 가정하여 등가점성감쇠비를 구하였다. 마지막으로, 유도한 자유진동과 조화가진의 등가점성감쇠비를 이용한 등가선형운동방정식의 해를 비선형 수치해석 한 결과와 비교하여 검증하였다.

보통중심가새골조의 내진보강을 위한 자가복원형 점성감쇠기 시스템 개발 (Development of Self-centering Viscous Damper System for Seismic Retrofit of Ordinary Concentrically Braced Frame)

  • 김도연;최혁순;강주형;이용선
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제27권6호
    • /
    • pp.70-78
    • /
    • 2023
  • 보통중심가새골조는 단순한 설계절차를 갖는 이점이 있다. 이와 같은 이유로, 지진하중에 대한 내진성능이 다른 골조 시스템에 비해 크게 효과적이지 않음에도 불구하고 중간 또는 낮은 수준의 지진을 받는 소규모 골조 구조물에 널리 사용되어 왔다. 횡방향 지진 하에서 압축 거동에 대해 취약한 가새부재를 갖는 보통중심가새골조의 내진성능을 향상시키기 위해, 통상적으로 점성감쇠기에 의한 내진보강이 도입되어 왔다. 하지만, 점성감쇠기 자체는 일반적으로 구조물을 원래 위치로 복원시킬 수 있는 강성을 갖지 않는다. 이는 구조물에 잔류 변위를 유발시킬 수도 있다. 이 논문에서는 휨강성을 갖는 상·하부 보가 비선형-탄성 스프링 역할을 하여 외부 변위 이력을 받는 스프링-감쇠기 시스템을 원래 위치로 복원시키는 자가복원형 점성감쇠기 시스템이 개발되었다. 단순화된 골조 구조물에 대한 수치해석은 개발된 자가복원형 점성감쇠기 시스템을 포함할 경우 지진이 가해지는 동안 에너지 소산을 통해 어떻게 골조 구조물의 향상된 내진성능을 가져오는지 보여준다.

원자력발전소 비상디젤발전기의 가동중 진동저감 효과 (Operating Vibration Reduction Effect Evaluation of EDG at the NPP Site)

  • 김민규;전영선
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.111-118
    • /
    • 2006
  • The Emergency Diesel Generator(EDG) is a very important piece of equipment for the safety of a Nuclear Power Plant(NPP). In this study, the operating vibration or three kinds or EDG system was measured. The target EDG systems art Yonggwang 5 unit, Ulchin 2 unit and Ulchin 3 unit. The Yonggwang 5 and Ulchin 3 unit EDG system is the same type but the foundation systems are different. One is an anchor bolt type and the other is a spring and viscous-damper type. The purpose of this measurement is for a verification of the vibration isolation effect according to the foundation system. As a result. it can he said that the spring and viscous damper system of the EDG performed well for the vibration isolation.

  • PDF

점성댐퍼를 갖는 엔진 축계의 안정성 해석 및 비선형 비틀림강제진동 (A Study on the Stability Analysis and Non-linear Forced Torsional Vibration for the Dngine Shafting System with Viscous Damper)

  • 박용남;하창우;김의간;전효중
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1996년도 추계학술대회논문집; 한국과학기술회관, 8 Nov. 1996
    • /
    • pp.282-287
    • /
    • 1996
  • The non-linear torsional vibrations of the propulsion shafting system with viscous damper are considered. The motion is modeled by non-linear differential equations of second order. the equivalent system is modeled by two mass softening system with Duffing's oscillator. The steady state response of a equivalent system is analyzed for primary resonance only. Harmonic balance method as a non-linear vibration analysis technique is used. Jump phenomena are explained. The primary unstable region obtained by the Mathieu equation is investigated. Both theoretical and measured results of the propulsion shafting system are compared with and evaluated. As a result of comparisons with both data, it was confirmed that Duffing's oscillator can be used as a analysis method in the modeling of the propulsion shafting system attached viscous damper with non-linear stiffness.

  • PDF