• Title/Summary/Keyword: Virtual patient

Search Result 181, Processing Time 0.023 seconds

Efficient Graph Construction and User Movement Path for Fast Inspection of Virus and Stable Management System

  • Kim, Jong-Hyun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.8
    • /
    • pp.135-142
    • /
    • 2022
  • In this paper, we propose a graph-based user route control for rapidly conducting virus inspections in emergency situations (eg, COVID-19) and a framework that can simulate this on a city map. A* and navigation mesh data structures, which are widely used pathfinding algorithms in virtual environments, are effective when applied to CS(Computer science) problems that control Agents in virtual environments because they guide only a fixed static movement path. However, it is not enough to solve the problem by applying it to the real COVID-19 environment. In particular, there are many situations to consider, such as the actual road traffic situation, the size of the hospital, the number of patients moved, and the patient processing time, rather than using only a short distance to receive a fast virus inspection.

Basic Survey on the Knowledge, Performance, Confidence, and Attitude for CPR Education Proposal for Inactive Nurse

  • Park, Jung-Ha
    • International Journal of Advanced Culture Technology
    • /
    • v.10 no.1
    • /
    • pp.187-195
    • /
    • 2022
  • Since most of the first witnesses of cardiac arrest in clinical settings are nurses, the ability to perform CPR is important. The purpose of this study is to provide basic data for developing education that strengthens CPR performance in the future by examining inactive nurses' CPR knowledge, attitude, performance confidence, device discomfort, continued use intention, and educational achievement. The final subjects of this study were 88 inactive nurses residing in B city. The study period was from June 23, 2020 to December 24, 2020. The collected data were analyzed by descriptive statistics and Pearson correlation using SPSS WIN 24.0 program. After obtaining the subject's consent for the study, an inactive nurse who understood the purpose of the study and voluntarily consented to the study participated. To investigate the perception of experience, the subjects watched 360-degree virtual reality contents about CPR in the hospital using HMD. The data of this study were analyzed using SPSS WIN 22.0.program. As a result of this 360-degree study on CPR in the hospital, the average score for the inactive nurses on CPR knowledge was 12.70±3.43, the average score for performance confidence was 6.04±2.45, and the average score for attitude was 4.63±0.80. As a result of experience recognition of 360-degree virtual reality contents for CPR in hospitals, the average score for device discomfort was 4.01±0.94, the average score for continued use intention was 2.07±0.85, and the average score for educational achievement was 2.11±0.79. As a result of correlation analysis, educational achievement and continued use intention were significantly positively correlated (r=.77, p<.001). Based on the results of this study, in order to strengthen the CPR performance capability of inactive nurses in emergency situations, it is necessary to increase CPR knowledge and confidence in performing CPR, and to cultivate a positive attitude toward performing CPR. In addition, it is necessary to implement CPR simulation education based on patient cases by applying content that considers educational achievement and continuous use intention.

Spatial Relationship of the Left Ventricle in the Supine Position and the Left Lateral Tilt Position (Implication for Cardiopulmonary Resuscitation in Pregnant Patients) (앙와위와 좌측 기울린위치에서의 좌심실의 공간적 관계 변화. 임신부 심폐소생술 측면에서)

  • Yun, Jong Geun;Lee, Byung Kook
    • Fire Science and Engineering
    • /
    • v.27 no.5
    • /
    • pp.75-79
    • /
    • 2013
  • Application of the left lateral tilt position has been recommended during cardiopulmonary resuscitation (CPR) of pregnant patients. However, the left lateral tilt could displace the left ventricle (LV) besides the gravid uterus and may compromise the cardiac pump mechanism of CPR. Thus, we investigated the effect of left lateral tilt on the spatial relationship between the anterior-posterior axis (AP axis), which represents the direction of sternal displacement during CPR, and the LV. We retrospectively reviewed the medical records and multidetector computed tomography (MDCT) scans of 90 patients who underwent virtual gastroscopy using MDCT. Virtual gastroscopy was performed with the patient both in the left lateral tilt position and in the supine position. On an axial image showing the maximal area of the LV, the angle between the AP axis and the LV axis ($Angle_{AP-LV}$), the shortest distance between the AP axis and the mid-point of LV cavity ($D_{AP-MidLV}$) and the shortest distance between the AP axis and the LV apex ($D_{AP-Apex}$) were measured. In the supine scans, the LV was situated on the left side of the AP axis in 87 patients (96.7%). On the left lateral tilt scans, the mean tilt angle was $43.4{\pm}11.0^{\circ}$. $D_{AP-MidLV}$ and $D_{AP-Apex}$ were significantly longer in the left lateral tilt position (p<0.001), but $Angle_{AP-LV}$ was comparable between the positions. This study indicates that the left lateral tilt position may compromise the cardiac pump mechanism of chest compression in pregnant cardiac arrest patients.

Evaluation of the Usefulness of Virtual Reality Equipment for Relieving Patients' Anxiety during Whole-Body Bone Scan (전신 뼈 검사 환자의 불안감 해소를 위한 가상현실 장비의 유용성 평가)

  • Kim, Hae-Rin;Kim, Jung-Yul;Lee, Seung-Jae;Baek, Song-Ee;Kim, Jin-Gu;Kim, Ga-Yoon;Nam-Koong, Hyuk;Kang, Chun-Goo;Kim, Jae-Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.1
    • /
    • pp.27-32
    • /
    • 2022
  • Purpose When performing a whole-body bone scan, many patients are experiencing psychological difficulties due to the close distance to the detector. Recently, in the medical field, there is a report that using virtual reality (VR) equipment can give pain relief to pediatric patients with weak concentration or patients receiving severe treatment through a distraction method. Therefore, in this paper, VR equipment was used to provide psychological stability to patients during nuclear medicine tests, and it is intended to evaluate whether it can be used in clinical practice. Materials and Methods As VR equipment, ALLIP Z6 VR (ALLIP, Korea) was used and the experiment was conducted after connecting to a mobile phone. The subjects were 30 patients who underwent whole-body bone examination from September 1, 2021 to September 30, 2021. After intravenous injection of 99mTc-HDP, 3 to 6 hours later, VR equipment was put on and whole body images were obtained. After the test, a survey was conducted, and a Likert scale of 5 points was used for psychological anxiety and satisfaction with VR equipment. Hypothesis verification and reliability of the survey were analyzed using SPSS Statistics 25 (IBM, Corp., Armonk, NY, USA). Results Anxiety about the existing whole-body bone test was 3.03±1.53, whereas that of anxiety after wearing VR equipment was 2.0±1.21, indicating that anxiety decreased to 34%. When regression analysis of the effect of the patient's concentration on VR equipment on anxiety about the test, the B value was 0.750 (P<0.01) and the t value was 6.181 (P<0.01). decreased and showed an influence of 75%. In addition, overall satisfaction with VR equipment was 3.76±1.28, and the intention to reuse was 66%. The Cronbach α value of the reliability coefficient of the questionnaire was 0.901. Conclusion When using VR equipment, patients' attention was dispersed, anxiety was reduced, and psychological stability was found. In the future, as VR equipment technology develops, it is thought that if the equipment can be miniaturized and the resolution of VR content images is increased, it can be used in various clinical settings if it provides more realistic stability to the patient.

Esthetic restoration of maxillary anterior teeth considering facial features in digital diagnostic wax-up: a case report (디지털 진단 왁스업을 통하여 안모를 고려한 상악 전치부 심미수복 증례)

  • Sung-Ji Gong;Sang-Won Park;Hyun-Pil Lim;Kwi-dug Yun;Chan Park;Woohyung Jang
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.3
    • /
    • pp.179-188
    • /
    • 2024
  • To enhance the predictability of aesthetic treatment outcomes in aesthetic prosthetic restorations, considerations must include analysis of facial features, the relationship between teeth and lips, proportions of tooth width/length, gingival form, and more. Traditional diagnostic wax-ups have limitations in considering the patient's facial features and are unable to facilitate rapid form modifications. With recent advancements in digital technology, it is now possible to digitize the patient's facial features in three dimensions, enabling the design of restorations that harmonize with facial features. These digital workflows not only improve efficiency but also provide patients with faster visualization of treatment outcomes, thereby enhancing motivation. Therefore, in this case, a treatment plan is devised to utilize digital diagnostic wax-ups considering the patient's facial features for the final prosthetic design.

Implant Fixture Installation in the Anterior Mandible by Use of a Mucosa Supported Surgical Template Based on Computer Assisted Treatment Planning (컴퓨터보조 기반 점막지지 서지컬템프레이트를 이용한 하악전치부 임플란트 식립)

  • Lee, Jee-Ho;Kim, Soung-Min;Kim, Myung-Joo;Park, Jung-Min;Seo, Mi-Hyun;Myoung, Hoon;Lee, Jong-Ho;Kim, Myung-Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.33 no.2
    • /
    • pp.158-165
    • /
    • 2011
  • A 73-year-old Korean female patient with a fully edentulous mandible was planned to have five implant fixtures installed in the anterior mandible for the fixed prosthesis. After 3-dimensional (3D) computed tomographic scanning was transferred to OnDemand3D$^{(R)}$ (Cybermed Co., Seoul, Korea) software program for the virtual planning, five fixtures of MK III Groovy RP implants of Branemark System$^{(R)}$ (Nobel Biocare AB Co., Goteborg, Sweden) were installed in the anterior mandible between both mental foramens using In2Guide$^{(R)}$ (CyberMed Co., Seoul, Korea) mucosa-supported surgical template with Quick Guide Kit$^{(R)}$ (Osstem Implant Co., Seoul, Korea) systems. Fixture installations were completed successfully without any complications, such as mental nerve injury, bony bleedings, fenestrations and other unexpected events. Postoperative computed tomographic scans were aligned and fused to the planned implant, then angular and linear deviations were compared with the planned virtual implants. The mean angular deviation between the planned and actual implant axes was $3.42{\pm}1.336^{\circ}$. The mean distance between the planned and actual implant at the neck area was $0.544{\pm}0.290$ mm horizontally and $0.118{\pm}0.079$ mm vertically. The average distance between the planned and actual implant at the apex area was $1.166{\pm}0.566$ mm horizontally and $0.14{\pm}0.091$ mm vertically. These results could be considered more precise and accurate than previous reports, and even our recent results. The entire procedures of this case are reported and reviewed.

A Study on Virtual Reality Management of 3D Image Information using High-Speed Information Network (초고속 정보통신망을 통한 3차원 영상 정보의 가상현실 관리에 관한 연구)

  • Kim, Jin-Ho;Kim, Jee-In;Chang, Chun-Hyon;Song, Sang-Hoon
    • The Transactions of the Korea Information Processing Society
    • /
    • v.5 no.12
    • /
    • pp.3275-3284
    • /
    • 1998
  • In this paper, we deseribe a Medical Image Information System. Our system stores and manages 5 dimensional medical image data and provides the 3 dimensional medical data via the Internet. The Internet standard VR format. VRML(Virtual Reality Modeling Language) is used to represent the 3I) medical image data. The 3D images are reconstructed from medical image data which are enerated by medical imaging systems such ans CT(Computerized Tomography). MRI(Magnetic Resonance Imaging). PET(Positron Emission Tomograph), SPECT(Single Photon Emission Compated Tomography). We implemented the medical image information system shich rses a surface-based rendering method for the econstruction of 3D images from 2D medical image data. In order to reduce the size of image files to be transfered via the Internet. The system can reduce more than 50% for the triangles which represent the surfaces of the generated 3D medical images. When we compress the 3D image file, the size of the file can be redued more than 80%. The users can promptly retrieve 3D medical image data through the Internet and view the 3D medical images without a graphical acceleration card, because the images are represented in VRML. The image data are generated by various types of medical imaging systems such as CT, MRI, PET, and SPECT. Our system can display those different types of medical images in the 2D and the 3D formats. The patient information and the diagnostic information are also provided by the system. The system can be used to implement the "Tele medicaine" systems.

  • PDF

Dental Surgery Simulation Using Haptic Feedback Device (햅틱 피드백 장치를 이용한 치과 수술 시뮬레이션)

  • Yoon Sang Yeun;Sung Su Kyung;Shin Byeong Seok
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.12 no.6
    • /
    • pp.275-284
    • /
    • 2023
  • Virtual reality simulations are used for education and training in various fields, and are especially widely used in the medical field recently. The education/training simulator consists of tactile/force feedback generation and image/sound output hardware that provides a sense similar to a doctor's treatment of a real patient using real surgical tools, and software that produces realistic images and tactile feedback. Existing simulators are complicated and expensive because they have to use various types of hardware to simulate various surgical instruments used during surgery. In this paper, we propose a dental surgical simulation system using a force feedback device and a morphable haptic controller. Haptic hardware determines whether the surgical tool collides with the surgical site and provides a sense of resistance and vibration. In particular, haptic controllers that can be deformed, such as length changes and bending, can express various senses felt depending on the shape of various surgical tools. When the user manipulates the haptic feedback device, events such as movement of the haptic feedback device or button clicks are delivered to the simulation system, resulting in interaction between dental surgical tools and oral internal models, and thus haptic feedback is delivered to the haptic feedback device. Using these basic techniques, we provide a realistic training experience of impacted wisdom tooth extraction surgery, a representative dental surgery technique, in a virtual environment represented by sophisticated three-dimensional models.

Full-mouth rehabilitation of a patient with severe wear using digital facebow transfer and virtual articulator (디지털 안궁이전과 가상교합기를 이용한 광범위한 치아 마모 환자의 완전구강회복 증례)

  • Jinmook Chung;Younghoo Lee;Seoung-Jin Hong;Janghyun Paek;Kwantae Noh;Hyeong-Seob Kim;Kung-Rock Kwon;Ahran Pae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.275-283
    • /
    • 2023
  • The progressive wear of teeth is a physiologic process of aging, but excessive wear can lead to occlusal disharmony, tooth sensitivity and pulp exposure, decreased masticatory efficiency, and aesthetic problems. It should be treated by evaluating the cause of tooth wear and establishing a stable centric relation with appropriate vertical dimension of occlusion and occlusal plane. The present case report successfully rehabilitated a full-mouth case of a severely worn dentition with the use of digital facebow transfer and virtual articulator.

In Pediatric Leukemia, Dose Evaluation according to the Type of Compensators in Total Body Irradiation (소아백혈병 환자의 전신방사선조사 시 조직보상체의 재질변화에 따른 선량평가)

  • Lee, Dongyeon;Kim, Changsoo;Kim, Junghoon
    • Journal of radiological science and technology
    • /
    • v.38 no.1
    • /
    • pp.17-21
    • /
    • 2015
  • Total body irradiation(TBI) and chemotherapy are the pre-treatment method of a stem cell transplantations of the childhood leukemia. in this study, we evaluate the Quantitative human body dose prior to the treatment. The MCNPX simulation program evaluated by changing the material of the tissue compensators with imitation material of pediatric exposure in a virtual space. As a result, first, the average skin dose with the material of the tissue compensators of Plexiglass tissue compensators is 74.60 mGy/min, Al is 73.96 mGy/min, Cu is 72.26 mGy/min and Pb 67.90 mGy/min respectively. Second, regardless of the tissue compensators material that organ dose were thyroid, gentile, digestive system, brain, lungs, kidneys higher in order. Finally, the ideal distance between body compensator and the patient were 50 cm aparting each other. In conclusion, tissue compensators Al, Cu, Pb are able to replace of the currently used in Plexiglass materials.