• 제목/요약/키워드: View Projection

검색결과 199건 처리시간 0.024초

동적 시준을 이용한 CT 촬영과 볼록한 관심영역의 영상재구성 (Dynamically Collimated CT Scan and Image Reconstruction of Convex Region-of-Interest)

  • 진승오;권오경
    • 대한의용생체공학회:의공학회지
    • /
    • 제35권5호
    • /
    • pp.151-159
    • /
    • 2014
  • Computed tomography (CT) is one of the most widely used medical imaging modality. However, substantial x-ray dose exposed to the human subject during the CT scan is a great concern. Region-of-interest (ROI) CT is considered to be a possible solution for its potential to reduce the x-ray dose to the human subject. In most of ROI-CT scans, the ROI is set to a circular shape whose diameter is often considerably smaller than the full field-of-view (FOV). However, an arbitrarily shaped ROI is very desirable to reduce the x-ray dose more than the circularly shaped ROI can do. We propose a new method to make a non-circular convex-shaped ROI along with the image reconstruction method. To make a ROI with an arbitrary convex shape, dynamic collimations are necessary to minimize the x-ray dose at each angle of view. In addition to the dynamic collimation, we get the ROI projection data with slightly lower sampling rate in the view direction to further reduce the x-ray dose. We reconstruct images from the ROI projection data in the compressed sensing (CS) framework assisted by the exterior projection data acquired from the pilot scan to set the ROI. To validate the proposed method, we used the experimental micro-CT projection data after truncating them to simulate the dynamic collimation. The reconstructed ROI images showed little errors as compared to the images reconstructed from the full-FOV scan data as well as little artifacts inside the ROI. We expect the proposed method can significantly reduce the x-ray dose in CT scans if the dynamic collimation is realized in real CT machines.

컴퓨터게임에 나타난 투영도법의 변천과 전개방향 (The Changes and Future Direction of Graphical Projection in Computer Games)

  • 하동원;이창조
    • 한국게임학회 논문지
    • /
    • 제10권4호
    • /
    • pp.3-13
    • /
    • 2010
  • 이 글은 그래픽사용자 환경을 지원하는 컴퓨터게임에서 나타난 투영의 방법들에 관한 연구다. 기존 연구들은 특정 투영도법에 관한 사례연구나 미학적 접근들이 대부분이다. 연구자는 컴퓨터게임에 나타난 투영도법을 게임 연대기를 따라 조사하고 분석하여, 이것의 변천과정과 앞으로의 방향에 관해 연구하였다. 또한 다양한 투영도법들의 감성적 측면과 생산적 측면을 살펴본 바, 컴퓨터 게임에 나타난 투영도법들은 그래픽 디자이너의 작업난이도와 컴퓨터 처리능력에 의존하여 발전하는 것으로 드러났다. 콘텐츠 소비자의 보는 방식을 결정짓는 투영도법은 콘텐츠 개발의 기획단계에서 결정되어야 하는 매우 중요한 요소임으로 이 연구의 결과가 유관 분야에 조금이나마 기여할 수 있기를 기대한다.

전사방식 마이크로광조형을 이용한 배열 형태 미세 구조물 가공 (Fabrication of Microstructure Array using the Projection Microstereolithography System)

  • 최재원;하영명;이석희
    • 한국정밀공학회지
    • /
    • 제24권8호통권197호
    • /
    • pp.138-143
    • /
    • 2007
  • Microstereolithography technology is similar to the conventional stereolithography process and enables to fabricate a complex 3D microstructure. This is divided into scanning and projection type according to aiming at precision and fabrication speed. The scanning MSL fabricates each layer using position control of laser spot on the resin surface, whereas the projection MSL fabricates one layer with one exposure using a mask. In the projection MSL, DMD used to generate dynamic pattern consists of $1024{\times}768$ micromirrors which have $13.68{\mu}m$ per side. The fabrication range and resolution are determined by the field of view of the DMD and the magnification of the projection lens. If using the projection lens with high power, very fine microstructures can be fabricated. In this paper, the projection MSL system adapted to a large surface for array-type fabrication is presented. This system covers the meso range, which is defined as the intermediate range between micro and macro, with a resolution of a few ${\mu}m$. The fabrication of array-type microstructures has been demonstrated to verify the performance of implemented system.

The effect of the tongue in groove technique on the nasolabial angle and nasal tip projection

  • Khabir, Fatemeh;Sezavar, Mehdi;Bohluli, Behnam;Mesgarzadeh, Vahid;Tavakoli, Hamidreza
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제42권
    • /
    • pp.19.1-19.4
    • /
    • 2020
  • Background: The tongue in groove technique (TIG) is a useful technique for the correction of the nasal tip projection and the nasolabial angle. The purpose of this study was to determine the utility of this technique for nasal tip rotation and projection correction in the Iranian society. Methods: This is a retrospective clinical trial study of 20 patients undergoing open septo-rhinoplasty using TIG technique from January 2017 to August 2019 at the oral and maxillofacial unit of Bu Ali Hospital and private sector. Preoperative and postoperative profile view photographs were compared to assess the changes in tip projection and rotation. Results: Fifteen patients (75%) had normal angular size, and 5 of them (25%) were not within the normal range after the surgery. The Fisher exact test showed that this success was statistically significant (P = 0.006). Ten patients (50%) had normal projection size, postoperatively. The Fisher exact test showed that this effect was statistically significant (P < 0.01) Conclusion: The study demonstrated the benefit of TIG on the correction of nasal tip projection and rotation.

Multi-view Display with Hologram Screen using Three-dimensional Bragg Diffraction

  • Okamoto, Masaaki;Shimizu, Eiji
    • Journal of Information Display
    • /
    • 제3권3호
    • /
    • pp.1-11
    • /
    • 2002
  • Multi-view function is important to three-dimensional displays without dedicated glasses. It is the reason that the observers earnestly desire to change their positions freely. Multi-viewing is also principal to the reality of three-dimensional (3D) image displayed on the screen. The display of projection type has the advantage that the number of viewing points can be easily increased according to the number of projectors. The authors research on multi-view projection display with hologram screen. Powerful directionality of the diffracted beam from hologram screen is required unlike two-dimensional (2D) display. We developed a new method that all diffracted beams satisfied the same Bragg condition and became sufficiently bright to observe the 3D image under usual indoor light. The principle is based on the essential Bragg diffraction in the three-dimensional space. Owing to such three-dimensional Bragg diffraction we achieved an excellent hologram screen that could be multiple reconstructed in spite of single recording. This hologram screen is able to answer arbitrary numbers of viewing points within wide viewing zone. The distortion of 3D image becomes also sufficiently small with the method of dividing the cross angle between illumination and diffraction beam.

3D Projection Screen using Advanced Volume Holography

  • Okamoto, Masaaki;Shimizu, Eiji
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.1005-1008
    • /
    • 2002
  • The authors introduce 3D display systems developed in our laboratories for recent ten years. Those are mainly realized by several technologies in holography: electro-holography. holographic stereogram, holographic optical elements (HOE) and hologram screen. We are currently focusing the development of 3D projection screen without glasses. Powerful directionality of the light beam is required for 3D projection screen unlike 2D type. We succeeded in achieving the superior diffractive efficiency of hologram screen that is based on the advanced volume holography. This technology is extensively useful to retrieve the Bragg condition of volume hologram in the three-dimensional space. Owing to this technology we could establish the principle of multi-view projection screen and have confirmed the case of 4 viewing points.

  • PDF

공공디자인에 있어 프로젝션 매핑영상의 평가요소에 관한 실증적 연구 (An Empirical Study on Evaluation Criteria of Projection Mapping Videos in Terms of Public Design)

  • 이영우
    • 한국멀티미디어학회논문지
    • /
    • 제18권8호
    • /
    • pp.950-959
    • /
    • 2015
  • The necessity of an empirical study on how projection mapping videos are evaluated from consumers' point of view has arisen, as they can lead to visual pollution if factors including spatial characteristics around the structure and details of the contents are not taken into consideration. This study aims to evaluate projection mapping videos and elucidate the question on whether evaluation criteria positively influence the satisfaction level or not. Above all, five evaluation criteria including artistry, creativity, identity, immersion and usefulness were deducted and a hypothesis from preceding research "each evaluation criteria will positively(+) influence the satisfaction level of projection mapping video" has been established. In order to test the hypothesis, big domestic department stores which screened projection mapping videos were selected and a verification experiment has been conducted with ordinary citizens as subjects. In the result of the experiment, among the five evaluation criteria, artistry, creativity, and usefulness were chosen, while identity and immersion were dismissed. The result verifies that if useful information is provided in forms of interesting contents produced with distinctive ideas and creative methods, it will satisfy the consumers as attractive public design.

견관절 충돌증후군의 단순X선촬영 방법에 대한 검토 (Methods on Simple Radiography of Impingement Syndrome in Shoulder Joint)

  • 권대철;김문선;김용섭;정경모
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제23권1호
    • /
    • pp.21-27
    • /
    • 2000
  • To evaluation of patients who have shoulder impingement syndrome is by diagnostic radiography. Shoulder impingement is a problem which occurs in young, active individuals as well as older individuals. In fact, the pain is probably caused by repetitive stress placed on the shoulder joint either through recreational activities of your occupation. Impingement series approach to radiographic examination of the shoulder is take five projections. First anteroposterior oblique projection. Second standard anteroposterior projection. Third superoinferior axial projection. Fourth supraspinatus outlet projection offers a view of the outlet of the supraspinatus tendon unit as it passes under the coraacromial arch. Fifth anteroposterior $30^{\circ}$ caudal projection will adequately demonstrate the anterior acromial spur or ossification in the coraacromial ligament and more reliable to demonstrate spurring of the anterior acromion than supraspinatus outlet projection. This decreased the need for additional radiographic veiws, reduces the patient's exposure to x - ray radiation and decreases use of film. This can lower the cost of the evaluation and improve patient satisfaction.

  • PDF

Retinal Projection Display for Low Vision Aid

  • Nakamura, Hajime;Ando, Takahisa;Shimizu, Eiji
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.1009-1011
    • /
    • 2002
  • We developed a Retinal Projection Display for a low vision aid. This device can be applied to a low vision whose visual sense is weak. In the device, a digital image was formed with spatial light modulator(SLM) and projected onto a retina with the Maxwellian View. The image on this display can be seen clearly without our ocular accommodation and a low vision can see it without correction of a refraction error.

  • PDF

Application Study on the View Points Analysis for National Roads Route using Digital Elevation Data

  • Yeon, Sang-Ho;Hong, Ill-Hwa
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2002년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.292-296
    • /
    • 2002
  • This study has been accomplished as a experimental study for field application of 3D Perspective Image Map creation using Digital Topographical Map and based on the Ortho-Projection Image which is generated from Satellite Overlay Images and the precise Relative Coordinates of longitude, latitude and altitude which is corrected by GCP(Ground Control Point). AS to Contour Lines Map which is created by Coordinate conversion of 1:5,000 Topographical Map, we firstly made Satellite Image Map to substitute for Digital Topographical Map through overlapping the original images on top of each Ortho-Projection Image created and checking the accuracy. In addition to 3D Image Map creation for 3D Terrain analysis of a target district, Slope Gradient Analysis, Aspect Analysis and Terrain Elevation Model generation, multidirectional 3D Image generation by DEM can be carried out through this study. This study is to develop a mapping technology with which we can generate 3D Satellite Images of a target district through the composition of Digital Maps and Facility Blueprint and arbitrarily create 3D Perspective Images of the target district from any view point.

  • PDF