• Title/Summary/Keyword: Vibro-hammer

Search Result 11, Processing Time 0.022 seconds

A Study on the Performance Improvement of a Hydraulic Vibro-hammer System (유압식 진동 항타 시스템의 성능 향상을 위한 연구)

  • 정해권;성원준;송창섭
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.6
    • /
    • pp.169-175
    • /
    • 2000
  • In this study, the hydraulic vibro-hammer system was analyzed and the analysis tool using GUI was developed. From the parametric analysis, the effects of each factor were revealed. Through the simulation with varying parameters, the method to improve the performance of the hydraulic vibro-hammer system was presented. The analysis tool will help an unskilled programmer analyze the hydraulic vibro-hammer system. The result of this study will help improve the performance of the hydraulic vibro-hammer systems.

  • PDF

Enhancement of the Technique for Analyzing a Pile Driven by Vibro Hammer (진동해머에 의해 시공되는 말뚝의 해석기법 제고)

  • Lee, Seung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3596-3601
    • /
    • 2015
  • Enhancement of the existing program for analyzing a pile driven by vibro hammer was tried. Damping effect of dynamic soil resistance and clutch friction were added to the existing governing equation which constitute vibrating system of vibro hammer-pile-soil. Parameters of the modified Ramberg-Osgood model which simulates dynamic load transfer curves for the developed program were recomputed. Comparing the results of the modified program with those of the field tests, pile displacement with time and load transfer behavior were more similar to those of the field test. The penetration rates obtained from the modified program were more close to those of the field test rather than those of the commertical program.

Analytical Study on Vibrational Properties of Vibro-hammer (진동해머의 진동특성에 대한 해석적 연구)

  • Lee, Seung-Hyun;Kim, Eung-Seok;Yoon, Ki-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.7
    • /
    • pp.3577-3581
    • /
    • 2013
  • In order to analyze a pile constructed by vibro-hammer, vibrational characteristics of vibro-hammer should be investigated first. Analytical studies were conducted in order to investigate vibrational properties of vibro-hammer. It is thought that the concept of acting the spring force to the pile head should be replaced by the concept of considering the lumped mass of the exciter and the pile. For the situation of free vibration, spring force increase with increase of spring constant and the amplitude is little affected by the spring constant. Also for the situation of free vibration, amplitude is inversely proportional to the increase of mass of the exciter and it can be seen that spring force increase with amplitude by the same ratio. It can be seen that directions of the spring force and displacement are opposite to that of rotating mass.

The Design of Parameters to Improve Actuating Performance in High Frequency Vibro-Hammer(HFVH) and the Study of Characteristic Propagation and Attenuation of Piling Vibration (초고주파 진동항타기의 구동 성능향상을 위한 파라미터 설계 및 항타진동의 전달과 감쇠특성에 관한 연구)

  • Jang, Tae-In;Park, Joon-Hyuk;Baek, Yoon-Su;Kim, Sung-Bae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.6
    • /
    • pp.763-773
    • /
    • 2004
  • This paper suggests the 2 D.O.F mathematical model of the High Frequency Vibro-Hammer (HFVH), introduces an experimental method for measuring of the attenuation of piling vibration and proves what experiments are coincident with the equation of wave propagation. As vibratory installation of piles and casings has many economic merits in the construction field, most of all contractors prefer to vibratory pile driving method than the other. Compared to impact pile driving, vibratory installation has the advantage of reducing vibration or noise pollution and can drive piles under high frequency. Experiments serve estimations of capabilities and limitations of the HFVH's excitation force and finding of sensitivity for important soil resistance parameters. Also, we discuss the HFVH that can drive with three kinds of input waves (triangular, sine and square wave) and propose the design of parameters to improve actuating performance in it.

Performance Evaluation of the Vibro Hammer with Variable Amplitude by Field Tests (현장실험을 통한 저진동·저소음 진폭가변형 진동해머 성능 평가)

  • Han, Jin-Tae;Lee, Joonyong;Choi, Changho;Park, Jeong-Yel
    • Journal of the Korean Geosynthetics Society
    • /
    • v.14 no.3
    • /
    • pp.1-12
    • /
    • 2015
  • During installing sheet piles for an impermeable wall or a retaining wall, vibratory hammers are widely used. Among vibratory hammers, a hydraulic hammer is used most commonly. However, a hydraulic hammer causes excessive vibration and noise due to resonance by change of natural frequency according to movements of eccentric shaft when the hammer starts and stops. In this study, new variable amplitude type hammer is developed in order to reduce the vibration and noise due to resonance produced in starting and stopping the hammer. By controlling horizontal angle in two pairs of eccentric body inside of the hammer, the amplitude and vibration of the new hammer can be controlled. The performance tests with the new hammer and existing hammers such as the hydraulic hammer and electric hammer are carried out, and the new hammer shows reduced vibration and noise results in comparison with existing hammers from performance tests. Also, this study shows that penetration rates of sheet pile using the new hammer increase due to impellent force of a backhoe in comparison with the electric hammer and penetration rate increase in comparison with a general hydraulic hammer, since the new hammer can control the amplitude during penetration of sheet pile according to soil condition.

An Estimation of Bearing Capacity and Driveability of Steel Sheet Pile Installed by Vibratory Hammer (진동해머에 의해 설치되는 강널말뚝의 지지력 및 항타관입성 평가)

  • Lee, Seung-Hyun;Yune, Chan-Young;Kim, Byoung-Il
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.2
    • /
    • pp.339-347
    • /
    • 2007
  • Penetration tests were performed for two types of steel sheet piles which were driven in clay deposit and sand deposit. Penetration velocity data acquired from penetration tests were used in order to estimate bearing capacity and vibro-driveability of steel sheet piles. Bearing capacity values predicted from Davisson method and Bombard method were greater than that calculated from static bearing capacity formula by 11.9 times and 1.6 times respectively. Vibro-driveability predictions from $T\ddot{u}nkers$ method and ${\beta}$ method show correspondence to field test result fur sand deposit but not for clay deposit. From motor powers estimated by Savinov and Luskin method it can be seen that larger capacities of motor powers are required for clay deposit and adequate hammer was used for sand deposit.

  • PDF

Field Driveability Test of Wide Hat-type Sheet Pile using Vibro-Hammer (바이브로해머를 이용한 광폭 Hat형 강널말뚝의 현장 관입시험)

  • Kim, Byoung-Il;Kim, Jae-Kyu;Back, In-Chul;Lee, Seung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.1
    • /
    • pp.103-109
    • /
    • 2007
  • A new steel sheet pile of wide hat-type was developed. Advantage of using wide type of sheet pile is reducing steel weight and consequently cutting down construction cost. Field driveability tests were conducted in order to verifying vibro-driveability of wide hat-type sheet pile. As a result of the tests, penetration rates of newly developed sheet piles were less than those of U-type sheet piles. Axial stresses developed in sheet pile during driving were fur less than yield stress of sheet pile. Futhermore, initial penetration rates of sheet piles were much larger than those obtained from WEAP program.

  • PDF

A field-replace case for the cutoff of water on a seawall (방조제 차수를 위한 현장대체공법 사례)

  • Kim, Joon-Seok
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2016.11a
    • /
    • pp.181-182
    • /
    • 2016
  • 방조제 차수공사를 실시하는 현장 지반의 하부에 철재이물질과 돌망태 와이어 등이 매립되어 있는 것으로 확인된 상황에서 강널말뚝(sheet pile)을 풍화대까지 항타하는 것이 현실적으로 불가능하므로 상부는 철재이물질(돌망태 등)이 없는 심도까지 T-4 및 Vibro Hammer 에 의한 강널말뚝(sheet pile)을 이용하여 차수하고, 철재이물질과 돌망태 와이어 등이 매립되어 있는 것으로 확인된 하부 풍화대까지는 그라우팅에 의한 차수를 시도하는 현장차수방법을 시공하여 성공적으로 차수결과를 얻을 수 있었다.

  • PDF

Case History of Low Vibration and Low Noise Granular Pile Method in the Area of Incurred the Popular Enmity (민원발생지역에서의 저진동$\cdot$저소음 Granular Pile의 시공사례)

  • Chun, Byung-Sik;Kim, Baek-Young
    • Proceedings of the KSR Conference
    • /
    • 2003.10b
    • /
    • pp.176-181
    • /
    • 2003
  • Damages by vibration and noise due to the construction performance are increasing. The rise of construction demand and enlargement of equipments are major reasons of this damage. As a result, the enmity of the people is provoked and this appears to be an obstacle of construction work. Especially, in case of ground improvement construction. Casing pipe is inserted into the Sand Drain, Sand Compaction Pile and Vibrated Crushed-stone Pile by vibration power when carrying out. Hence, a pillar is formed and it creates vibration and noise. This causes a lot of restrictions to construction condition. The low Vibration and low noise construction equipments uses earth auger and hydrulic cylinder for insertion and chopping operation instead of vibro hammer, which is the source of vibration and noise. This minimize ground disturbanceand decrease vibration and noise successfully, but increase chopping effect greatly. Thus, this new equipment is not only suitable for environment but also excellent engineering method of construction.

  • PDF

A Case Study of Caisson Typed Bridge-Foundation Fabrication and Installation in Ul-san Newport Breakwater Project (케이슨식 교량기초 제작 및 거치 시공사례 -울산 신항 방파제현장 시공 사례를 중심으로-)

  • JANG BYUNG-SOO;SIN SUNG-GWEN;KIM DUCK-HO
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.45-50
    • /
    • 2004
  • The method of caisson typed bridge-foundation fabrication and installation applied in Ul-san newport breakwater project is throughly carried out to compact QRR mound vibro-hammer step by step to minimize settlement through stability check. Floating Dock was mobilized for caisson fabrication due to limited site area. fabricated caisson on the Floating Dock was towed to the deeper area of 8m water depth to be launched, and Floating Crane assisted launching and installation work of the caisson. finally water filling was done followed by surveying work to permanent installation.

  • PDF