• 제목/요약/키워드: Vibrational device

검색결과 30건 처리시간 0.028초

직교형 2차원 진동절삭기의 기구학적 해석 및 진동 특성 고찰 (Kinematical Analysis and Vibrational Characteristics of Orthogonal 2-dimensional Vibration Assisted Cutting Device)

  • 노병국;김기대
    • 한국소음진동공학회논문집
    • /
    • 제22권9호
    • /
    • pp.903-909
    • /
    • 2012
  • In elliptical vibration cutting(EVC) where the cutting tool traces a micro-scale 2-dimensional elliptical trajectory, the kinematical and vibrational characteristics of the EVC device greatly affect cutting performance. In this study, kinematical and vibrational characteristics of an EVC device constructed with two orthogonally-arranged stacked piezoelectric actuators were investigated both analytically and experimentally. The step voltage was applied to the orthogonal EVC device and the associated displacements of the cutting tool were measured to assess kinematical characteristics of the orthogonal EVC device. To investigate the vibrational characteristic of the orthogonal EVC, sinusoidal voltage was applied to the EVC device and the resulting displacements were measured. It was found from experiments that coupling of displacements in the thrust and cutting directions and the tilt of the major axis of the elliptical trajectory exists. In addition, as the excitation frequency is in vicinity of resonant frequencies the distortion in the shape of the elliptical trajectory becomes greater and change in the rotation direction occurs. To correct the shape distortion of the elliptical trajectory, the shape correcting procedure developed for the parallel EVC device was applied for the orthogonal EVC device and it was shown that the shape correcting method successfully corrects distortion.

고성능 AC-DC 변환기를 이용한 저전압 진동에너지 하베스팅 회로 (A Low-voltage Vibrational Energy Harvesting Circuit using a High-performance AC-DC converter)

  • 공효상;한장호;최진욱;윤은정;유종근
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 추계학술대회
    • /
    • pp.533-536
    • /
    • 2016
  • 본 논문에서는 진동 에너지를 이용한 MPPT 제어기능을 갖는 에너지 하베스팅 회로를 설계하였다. Body-bias technique과 bulk-driven technique을 이용하여 저전압에서도 높은 효율특성을 갖는 고성능 AC-DC 변환기를 제안하고 진동에너지 하베스팅 회로 설계에 적용하였다. MPPT (Maximum Power Point Tracking) 제어는 진동소자의 개방회로전압과 MPP 전압간의 관계를 이용하였으며, 진동소자의 개방회로전압을 주기적으로 샘플링 함으로써 이를 이용해 MPPT 기준전압을 생성하고, 이를 기준으로 부하로의 에너지 공급을 제어한다. $0.35{\mu}m$ CMOS 공정으로 설계된 회로의 칩 면적은 $1.21mm{\times}0.98mm$이다.

  • PDF

고속 생산형 필름 진동판 성형기 및 금형 국산화 개발(I) - 단수 생산 진동판 성형기 - (Domestic Development of Vibrational Film Forming Machine and Die and Mold in the High Speed Production(I) - Single production forming machine -)

  • 김정현
    • 한국기계가공학회지
    • /
    • 제11권6호
    • /
    • pp.9-15
    • /
    • 2012
  • Vibrational film has been more employed in ear-phones or small type of speakers along with a wide use of portable multi-media equipments such as MP3 and MP4. However, the current hand work production process of diaphragms is inefficient. In this study, a die-and-mold and a single production forming machine are developed, and they result in a multi-production forming machine. The multi-production forming machine consists primarily of a film feeding unit and an unwinding unit. A vacuum suction device provides the film feeding unit, while the unwinding unit is obtained using an appropriate damper. The advantage of the developed single production forming machine is shown according to a proper voice test.

Broadband energy harvester for varied tram vibration frequency using 2-DOF mass-spring-damper system

  • Hamza Umar;Christopher Mullen;Soobum Lee;Jaeyun Lee;Jaehoon Kim
    • Smart Structures and Systems
    • /
    • 제32권6호
    • /
    • pp.383-391
    • /
    • 2023
  • Energy harvesting in trams may become a prevalent source of passive energy generation due to the high density of vibrational energy, and this may help power structural health monitoring systems for the trams. This paper presents a broadband vibrational energy harvesting device design that utilizes a varied frequency from a tram vehicle using a 2 DOF vibrational system combined with electromagnetic energy conversion. This paper will demonstrate stepwise optimization processes to determine mechanical parameters for frequency tuning to adjust to the trams' operational conditions, and electromagnetic parameters for the whole system design to maximize power output. The initial optimization will determine 5 important design parameters in a 2 DOF vibrational system, namely the masses (m1, m2 (and spring constants (k1, k2, k3). The second step will use these parameters as initial guesses for the second optimization which will maintain the ratios of these parameters and present electrical parameters to maximize the power output from this system. The obtained values indicated a successful demonstration of design optimization as the average power generated increased from 1.475 mW to 17.44 mW (around 12 times).

진동절삭기 구성을 위한 자기변형 재료의 진동 특성 규명 (Vibrational Characteristics of Magnetostrictive Materials for a Vibration Assisted Cutting Device)

  • 이호철;김기대
    • 한국정밀공학회지
    • /
    • 제29권11호
    • /
    • pp.1214-1220
    • /
    • 2012
  • Vibration assisted cutting (VAC) is one of the promising methods for precision machining, which has been normally equipped with piezoelectric materials. In this paper, a feasibility of applying magnetostrictive materials to VAC as a cutting device instead of piezoelectric materials was studied. For this, the vibrational characteristics of a magnetostrictive material was investigated with respect to a coil design, a preload, and the effects of a biasing and an exciting magnetic fields. The output strain of a magnetostrictive material is restricted due to an increasing inductive impedance as the exciting frequency increases and the heat of coil, etc. Through the experimental results, it was found that the biasing and the exciting magnetic field affected the output performance significantly but not the preload. In conclusion, the magnetostrictive material could be used only in the low frequency range but not a good candidate for high frequency actuating application.

P(VDF-TrFE-CFE)를 이용한 초소형 압전 적층형 진동 출력 소자의 제작 (Fabrication of Ultra-Small Multi-Layer Piezoelectric Vibrational Device Using P(VDF-TrFE-CFE))

  • 조성우;;김재규;류정재;김윤정;김혜진;박강호;홍승범
    • 한국전기전자재료학회논문지
    • /
    • 제32권2호
    • /
    • pp.157-160
    • /
    • 2019
  • P(VDF-TrFE-CFE) (Poly (vinylidene fluoride-trifluoroethylene-chlorofluoroethylene)), which exhibits a high electrostriction of about 7%, can transmit tactile output as vibration or displacement. In this study, we investigated the applicability of P(VDF-TrFE-CFE) to wearable piezoelectric actuators. The P(VDF-TrFE-CFE) layers were deposited through spin-coating, and interspaced with patterned Ag electrodes to fabricate a two-layer $3.5mm{\times}3.5mm$ device. This layered structure was designed and fabricated to increase the output and displacement of the actuator at low driving voltages. In addition, a laser vibrometer and piezoelectric force microscope were used to analyze the device's vibration characteristics over the range of ~200~4,200 Hz. The on-off characteristics were confirmed at a frequency of 40 Hz.

PSN-PT 세라믹스의 진동레벨 특성 (Characteristics of vibrational level to PSN-PT ceramics)

  • 지승한;전석환;박성현;이능헌;이상훈;추순남;김용혁;이덕출
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1521-1523
    • /
    • 2001
  • In this paper, High quality factor and fine dielectric loss was resulted on specimen added 0.5wt% $MnO_2$ after compared and analyzed dielectric and piezoelectric properties following that added each 0 $\sim$ 0.9wt% of $Fe_2O_3$, $Nb_2O_5$, and $MnO_2$ on dopant at PSN-PT in two material disposition ceramics with research still is not completed to material investigation to increase high power piezoelectric actuator device efficiency. And, a measuring method and the experimental results of the temperature rise under the high vibrational velocity are also described.

  • PDF

와이어 방전가공기용 와이어의 진동 특성과 장력 변동 조절 (Vibration Characteristics and Tension Control of a Wire in WEDM)

  • 채호중;이승엽
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.629-635
    • /
    • 2000
  • Vibrational characteristics and tension fluctuation of a translating wire in WEDM are the main problems to deteriorate the cutting accuracy and processing performance. In this paper, we analyze natural frequencies of the wire used in WEDM, both theoretically and experimentally. To reduce the tension variation of the wire. which directly affects cutting performance. we have designed a simply tension reduction device using springs and rollers. It is shown that tension fluctuation is reduced about 25% using the passive tension controller.

  • PDF

초음파 수술기의 수술 효율성 향상을 위한 진동자 임피던스 측정에 따른 조직 분류 연구 (Classification of Organs Using Impedance of Ultrasonic Surgical Knife to improve Surgical Efficiency)

  • 김홍래;김성천;김광기;김영우
    • 대한의용생체공학회:의공학회지
    • /
    • 제34권3호
    • /
    • pp.141-147
    • /
    • 2013
  • Ultrasonic shears is currently in wide use as an energy device for minimal invasive surgery. There is an advantage of minimizing the carbonization behavior of the tissue due to the vibrational energy transfer system of the transducer by applying a piezoelectric ceramic. However, the vibrational energy transfer system has a pitfall in energy consumption. When the movement of the forceps is interrupted by the tissue, the horn which transfers the vibrational energy of the transducer will be affected. A study was performed to recognize different tissues by measuring the impedance of the transducer of the ultrasonic shears in order to find the factor of energy consumption according to the tissue. In the first stage of the study, the voltage and current of the transducer connecting portion were measured, along with the phase changes. Subsequently, in the second stage, the impedance of the transducer was directly measured. In the final stage, using the handpiece, we grasped the tissue and observed the impedance differences appeared in the transducer To verify the proposed tissue distinguishing method, we used the handpiece to apply a force between 5N and 10N to pork while increasing the value of the impedance of the transducer from 400 ${\Omega}$.. It was found that fat and skin tissue, tendon, liver and protein all have different impedance values of 420 ${\Omega}$, 490 ${\Omega}$, 530 ${\Omega}$, and 580 ${\Omega}$, respectively. Thus, the impedance value can be used to distinguish the type of tissues grasped by the forceps. In the future study, this relationship will be used to improve the energy efficiency of ultrasonic shears.