• 제목/요약/키워드: Vibration avoidance

검색결과 51건 처리시간 0.022초

무인 헬리콥터 마스터의 진동해석 및 공진회피 설계 (Vibration Analyses and Design of Resonance Avoidance of the Unmanned Helicopter Master)

  • 이성철;손인수;허관도
    • 한국정밀공학회지
    • /
    • 제28권8호
    • /
    • pp.951-958
    • /
    • 2011
  • In this paper, the purpose is to investigate the vibration characteristics and the design of resonance avoidance of the unmanned helicopter master. Based on the Euler-Bernoulli beam theory for helicopter master, the equation of motion is derived by using extended Hamilton's principle. It was studied about the natural frequency of helicopter master as the design variances(tip mass, length and diameter of master). Also, it was compared the theoretical results for natural frequency with the results of FE analysis. The results of this study showed the vibration characteristics of helicopter master for the design of resonance avoidance.

초임계 보일러 재열기 급수 공급배관의 과도 음향진동 진단 및 회피설계 (Mechanism Diagnosis and Avoidance Design on Transient Acoustic Vibration of Reheater Water Supply Piping in Supercritical Boiler)

  • 김연환;배용채;김재원;이두영;허해용
    • 한국소음진동공학회논문집
    • /
    • 제23권5호
    • /
    • pp.385-393
    • /
    • 2013
  • In this paper, the mechanism identification and the avoidance measures on the phenomena of transient acoustic vibration amplified at the water-supply piping system to regulate the steam temperature of the boiler reheater in 500MW class supercritical power plant are presented. The pressure pulsation waves induced by the impeller passing of two feed-water pumps with five blades are coincident with the local acoustic modes of boiler reheater water-supply piping system. There are the phenomena amplified at the peaks of 5X, 10X, 15X and 20X in spectrums of piping vibration, sound pressure, and the feed-water's pressure pulsation waves. The shut-off device is installed in the piping system for the interception of pressure pulsation waves transmitted from two feed-water pumps and the modified design change of the piping layout is applied for the acoustic resonance avoidance. The acoustic natural frequencies are separated from the harmonics of pressure pulsation waves induced by the pump impellers passing through the design change of the span length. The acoustic vibration is gone by resonance avoidance measures. As a result, more than 20 dBA reduction is achieved from 100 dBA to 80 dBA.

비전 시스템의 성능개선을 위한 진동 적응 방법 (Vibration Adaptive Algorithm for Vision Systems)

  • 서갑호;윤성조;박정우;박성호;김대희;손동섭;서진호
    • 한국생산제조학회지
    • /
    • 제25권6호
    • /
    • pp.486-491
    • /
    • 2016
  • Disturbance/vibration reduction is critical in many applications using machine vision. The off-focusing or blurring error caused by vibration degrades the machine performance. In line with this, real-time disturbance estimation and avoidance are proposed in this study instead of going with a more familiar approach, such as the vibration absorber. The instantaneous motion caused by the disturbance is sensed by an attitude heading reference system module. A periodic vibration modeling is conducted to provide a better performance. The algorithm for vibration avoidance is described according to the vibration modeling. The vibration occurrence function is also proposed, and its parameters are determined using the genetic algorithm. The proposed algorithm is experimentally tested for its effectiveness in the vision inspection system.

복합재 쿼드콥터의 진동 특성 분석과 공진 회피에 대한 연구 (Research of Vibration Analysis and Resonance Avoidance Design of Composite Quadcopter)

  • 김상률;김위대
    • Composites Research
    • /
    • 제33권3호
    • /
    • pp.133-139
    • /
    • 2020
  • 본 연구에서는 복합재료가 적용된 쿼드콥터의 진동 특성을 분석하고, 공진에 대해 회피 설계 및 해석을 수행하였다. 로터-암의 파이프가 복합재료로 구성된 상용 쿼드콥터의 플랫폼을 모사하고 상용 해석 프로그램을 이용하여 진동 특성 분석을 하였다. 실제 적층 배열을 해석에 적용하고, 참고 문헌과의 비교를 통해 신뢰성을 판단하였다. 그리고 모터의 가동범위 내에 특정 모드의 고유 진동수가 포함되는 것을 확인하였다. 기존 모델에서 적층 배열, 로터-암의 길이, 두께의 총 3가지의 변수를 선정해 공진 회피 설계를 수행하였다. 공진 회피 설계의 3가지 변수에서 각 해석의 결과를 비교한 후, 공진 회피 설계의 효율성 측면에서 방향을 제시하였다.

채터진동 검출 및 회피를 위한 가상 동적 가공시스템 구축 (Virtual Dynamic Machining System for Chatter Detection and Avoidance)

  • 김혁;조문호;구준영;이종환;김정석
    • 한국생산제조학회지
    • /
    • 제23권3호
    • /
    • pp.273-278
    • /
    • 2014
  • This study presents a chatter vibration avoidance program for the milling process. Chatter vibration has a negative effect on workpieces and spindle-tools. When chatter vibration occurs, the cutting tool is loaded dynamically, a chatter pattern is generated on the workpiece, and the tool life is reduced. The developed program is composed of various modules such as an FFT analyzer, an impact test analyzer, a chatter vibration indicator, and a spindle speed recommender. The proposed program is verified using an AISI D2 cutting experiment in milling process. The effect of chatter vibration on the machining condition can be simulated by the suggested method, and successfully exploited to avoid chatter vibration.

Directing the turning behavior of carp using virtual stimulation

  • Kim, Cheol-Hu;Kim, Dae-Gun;Kim, Daesoo;Lee, Phill-Seung
    • Ocean Systems Engineering
    • /
    • 제7권1호
    • /
    • pp.39-51
    • /
    • 2017
  • Fishes detect various sensory stimuli, which may be used to direct their behavior. Especially, the visual and water flow detection information are critical for locating prey, predators, and school formation. In this study, we examined the specific role of these two different type of stimulation (vision and vibration) during the obstacle avoidance behavior of carp, Cyprinus carpio. When a visual obstacle was presented, the carp efficiently turned and swam away in the opposite direction. In contrast, vibration stimulation of the left or right side with a vibrator did not induce strong turning behavior. The vibrator only regulated the direction of turning when presented in combination with the visual obstacle. Our results provide first evidence on the innate capacity that dynamically coordinates visual and vibration signals in fish and give insights on the novel modulation method of fish behavior without training.

입형펌프의 공진회피와 안전성 평가 (Resonance avoidance and Safety Evaluation of Vertical Pump)

  • 정우영;송진대
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 춘계학술대회 논문집
    • /
    • pp.698-702
    • /
    • 2013
  • This paper considers the vertical pumps resonance and soundness. Normally large vertical pump's rotating speed is low, so the low natural mode can make a resonance on the motor and motor stand assembly. The pump resonance makes a very high vibration and trouble on the pump systems. Thus to avoid pump resonance when the pump is on the resonance region, we give the added mass method and evaluate the structure soundness by computer simulation and test on the site. Furthermore we evaluate the modal sensitivity and expect running conditions by the using ISO10814.

  • PDF

개인고속이동 시스템의 차량운행에 대한 제어 (Control of the Operational Vehicles for Personal Rapid Transit System)

  • 이준호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.947-950
    • /
    • 2008
  • PRT(Personal Rapid Transit) systems requires very short headways to increase the line capacity and a very reliable vehicle control algorithm for avoidance of the impact between vehicles. In this paper a brake curves (or speed patterns) for PRT system that make it possible the effective vehicle control and a collision avoidance algorithm are introduced. For the simulations and the evaluations of the proposed algorithm a combined simulation platform that consists of Labview Simulation Interface Toolkit and Matlab/Simulink and a specific hardware configuration are employed.

  • PDF

배관에 의한 구조진동 진단 및 해결 사례 (A diagnosis and solution case of structural vibration caused by pipe)

  • 이정환;구동식;최병근
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1371-1374
    • /
    • 2007
  • A few intake stations have vibration problems caused by pipes. The vibration transffered from pipes excites building severely. Therefore, the crack is generated on building wall and people who work at intake station are damaged. In this paper, the vibration is measured and analysis is carried out for pipes at intake station in order to identify the usefulness and effectiveness of the solution proposed for pipe resonance avoidance. According to the result of analysis, bellows is reduced the vibration of pipes.

  • PDF