• Title/Summary/Keyword: Vibration Test Control

Search Result 572, Processing Time 0.027 seconds

Estimation of flanking transmission due to difference between laboratory and field test (실험실 및 현장실험을 통한 벽체의 우회전달음 평가에 관한 연구)

  • Chung, J.Y.;Lee, S.H.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1383-1386
    • /
    • 2006
  • This study examines the difference of airborne sound isolation between laboratory and field test. The airborne sound isolation between adjacent dwellings in multi-family buildings is often much less than would be expected from the rated sound reduction index of the nominally-separating wall, due to structure-borne transmission of vibration at the junctions of wall. A variety of construction modifications to control such transmission have also been evaluated. This study presents a factor of the difference for flanking involving joint of wall, and shows the effect of some practical modifications that control the key flanking paths

  • PDF

Effect of Local Vibration on Elbow Joint in Position Sense and Maximal Grip Force (국소적 진동 적용이 주관절의 위치 감각과 최대악력에 미치는 영향)

  • Heo, Gwang-Ho;Lee, Hyun-Min;Choen, Song-Hee;Bang, Hyun-Soo;Kang, Jong-Ho;Kim, Jin-Sang
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.3 no.3
    • /
    • pp.145-149
    • /
    • 2008
  • Purpose : The purpose of this study was evaluate the effects of vibration on joint position sense. Methods : The subjects were divided into vibration group(n=20) and control group(n=20). Vibration group was given local vibration on elbow joint for 15 minutes and control group was given resting 15 minutes by resting position. All subjects of each group were tested pre-post on maximal grip force and joint position sense. Results : Maximal grip force test and joint position sense test of vibration group was showed a significant difference between pre and post(p<0.05). Conclusion : There was a different change on maximal grip force and joint position sense.

  • PDF

Active Vibration Control of a Plate Using TMS320C6713DSK

  • Choi, Hyeung-Sik;You, Sam-Sang;Her, Jae-Gwan;Seo, Hae-Yong;Tran, Ngoc-Huy
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.3
    • /
    • pp.309-316
    • /
    • 2011
  • This paper deals with the experimental study of the vibration suppression of the smart structures. First, a new high-speed active control system is presented using the DSP320C6713 microprocessor. A peripheral system developed is composed of a data acquisition system, A/D and D/A converters, piezoelectric (PZT) actuator/sensors, and drivers using PA 95 for fast data processing. Next, the processing time of the peripheral device is tested and the corresponding test results are provided. Since fast data processing is very important in the active vibration control of the structures, achieving the fast loop times of the control system is focused. The control algorithm using PPF in addition to FIR filter is implemented. Finally, numerous experiments were carried out on the aluminum plate to validate the superior performance of the vibration control system at different control loop times.

The Effects of Whole-Body Vibration Training on the Flexibility and Agility of Professional Soccer Players (전신진동운동이 프로축구선수들의 유연성과 민첩성에 미치는 효과)

  • Kim, Kwang-Tae;Kim, Jin-Hong
    • PNF and Movement
    • /
    • v.18 no.1
    • /
    • pp.87-95
    • /
    • 2020
  • Purpose: The purpose of this study was to investigate the effect of whole-body vibration training on the flexibility and agility of professional soccer players. Methods: Sixteen professional soccer players participated voluntarily in the study. Subjects were allocated to two groups: the experimental group received whole-body vibration (WBV) and team training, and the control group received only team training. Team training was conducted in 15 sessions of 70 min duration over 3 weeks. WBV training was applied at 40 Hz frequency, 5 sets (1 min-training, 1 min-resting) in a squatting position. Outcomes from sit-and-reach, side-step test, burpee test, and T-test were measured before and after training. To examine pre- and post-intervention differences between the two groups, a paired t-test was used. Independent t-tests were performed to compare pre- and post-test scores and the time difference of the two groups. Results: Significant improvements in sit-and-reach and agility variables were observed in the experimental group (p < 0.05). In particular, flexibility (sit-and-reach) and agility (the side-step test and the burpee test) were significantly different between the two groups (p < 0.05). Conclusion: These findings suggest that whole-body vibration training has a positive effect on performance enhancement for professional soccer players.

A Study of Vibration Control of a Slender Structure Using a Multi-Degree-of-Freedom Manipulator (다 자유도 운동장치를 이용한 세장구조물의 진동제어 연구)

  • Kim, Nak-In;Lee, Jong-Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.8
    • /
    • pp.1227-1234
    • /
    • 2001
  • A multi d.o.f robotic manipulator is considered for multi-axis vibration control of a slender structure, using the concept of the flow source based vibration control. In order not to cause the motion saturation of the manipulator system, a hybrid dynamics associated with the flexible and desired manipulator error dynamics is also modeled as the control object. It is numerically shown that the flexible vibrations and the base motions of a test structure can be effectively controlled with the proposed hybrid dynamics.

A study on the vibration control of a MDOF system using the adaptive bang-bang control algorithm (적응형 뱅뱅 제어 알고리듬을 이용한 다자유도계의 진동 제어에 관한 연구)

  • Lim, C.W.;Chung, T.Y.;Moon, S.J.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.239-245
    • /
    • 2000
  • Adaptive bang-bang control algorithm has been proposed by the authors to improve peak response reduction of building structures under unexpected large earthquake. At the previous research, control performance of the proposed algorithm was experimentally confirmed by using a I-DOF test structure. As an extended research, performance tests on a multi-DOF model structure have been conducted to prove the usefulness of the adaptive bang-bang control algorithm using a hydraulic AMD. It is confirmed that the proposed adaptive bang-bang algorithm is applicable to suppress the vibration of multi-DOF structures subject to severe external excitations.

  • PDF

Vibration Control Performance of a Two-way Tuned Liquid Mass Damper Using Real-time Hybrid Shaking Table Testing Method (실시간 하이브리드 진동대 실험법에 의한 양방향 TLMD의 진동제어 성능평가)

  • Heo, Jae-Sung;Lee, Sung-Kyung;Park, Eun-Churn;Lee, Sang-Hyun;Kim, Hong-Jin;Jo, Ji-Seong;Cho, Bong-Ho;Min, Kyung-Won
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.5
    • /
    • pp.485-495
    • /
    • 2008
  • An experimental real-time hybrid method, which implements the vibration control of a building structure with only a two-way TLMD, is proposed and verified through a shaking table test. The building structure is divided into the upper experimental TLMD and the lower numerical structural part. The shaking table vibrates the TLMD with the response calculated from the numerical substructure, which is subjected to the excitations of the measured interface control force at its top story and sinusoidal waves input at its base. The results show that the conventional method can be replaced by the proposed methodology with a simple installation and accuracy for evaluating the control performance of a TLMD.

Study on the Vibration of Diesel Engine Generator of Drill Ship (드릴쉽 디젤엔진 발전기의 진동에 관한 연구)

  • Jin, Bong-Man;Park, Hyung-Sik;Kong, Yong-Mo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.4
    • /
    • pp.502-508
    • /
    • 2009
  • To obtain high power, diesel engines continuously increase combustion pressure and mean effective pressure each cylinder, and the excitation sources and noisy sources are increased, too. Moreover, to reduce the costs, shipyards make hull structures weaker than before. As above reasons, it is more difficult to control the vibration phenomenon nowadays. In this study, it was investigated why diesel generator sets reached the vibration allowable limits during the FAT and heavy vibration phenomenon of diesel generator sets using ODS test during onboard tests. Also, it is found out the stiffness of deck and common bed using the test result of their structural impedance. To find out the vibratory characteristics of diesel generator sets, model tests were carried out. From the sensitivity analysis after above tests, it was selected points to be reinforced and studied troubleshooting to solve heavy vibration phenomenon of diesel generator sets.

Effects of Simultaneous Application of Focal Vibration Stimulation and Task-Oriented Training in the Improvement of Upper Extremity Motor Function after Stroke (국소 진동자극과 과제 지향적 훈련의 동시 적용이 뇌졸중 환자의 상지 기능 개선에 미치는 효과)

  • Kim, Sunho
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.7 no.3
    • /
    • pp.117-125
    • /
    • 2019
  • Purpose : The purpose of this study was to determine the effects of simultaneous application of focal vibration stimulation and task-oriented training on the improvement in upper extremity motor function after stroke. Methods : The study period was from January to April 2019; 23 patients who fulfilled the study eligibility criteria were enrolled. The participants were divided into two groups: the experimental group with vibration stimulation and task-oriented training and the control group with only task-oriented training. Training was conducted in a total of 20 sessions, 5 times a week for 30 minutes a day for 4 weeks. The amount of use of the affected and unaffected side by accelerometers, and Box and Block test (BBT), Action Research Arm Test (ARAT) was measured with a pre-test, a post-test. Wilcoxon Signed Rank Test and Analysis of Covariance were used to compare and analyze the changes within and between the groups. Results : Both the groups showed statistically significant changes in the results of the BBT and the ARAT, as well as the amount of use of the affected and unaffected side. Regarding the use of the affected side, BBT results, and the grasp and gross movement item of the ARAT showed significant changes in the experimental group compared with the control group. Conclusion : We found that simultaneous application of focal vibration stimulation and task-oriented training was more effective than task-oriented training alone. A large-scale comparative study involving a group that is only given vibration stimulation should be conducted for more generalizable results.

A Noise Control of Cooler Housing in Large Scale Vertical Motor (대형 수직전동기 Cooler Housing의 이상소음 제어)

  • Joo, W.H.;Kim, D.H.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.132-137
    • /
    • 2000
  • Recently, a severe noise problem was encountered during a shop test of large scale vertical motor. In order to identify the noise characteristics and propose the countermeasure, a variety of experiments such as sound excitation test and contribution analysis was earned out in addition to ordinary noise and vibration measurements. The results showed that the severe noise level was dominated by an acoustic resonance phenonmenon in the cooler housing and higher sound power of outer fan. Through proper treatments, the noise level could be acceptable.

  • PDF