• Title/Summary/Keyword: Vibration Test Control

Search Result 572, Processing Time 0.023 seconds

Sensitivity Analysis of Anti-resonance Frequency for Vibration Test Control of a Fixture

  • Jeong, Weui-Bong;Yoo, Wan-Suk;Kim, Jun-Yeop
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.11
    • /
    • pp.1732-1738
    • /
    • 2003
  • The test specimen in environmental vibration test is connected to the fixture through several attachment points. The forces generated by the shaker must be transmitted equally to all attachment points. The forces transmitted to attachment points, however, are different because of the flexural vibration of the fixture. The variations of the transmitted force cause the under-test, especially at anti-resonance frequencies, in vibration test control. Anti-resonance frequencies at the attachment points of the fixture must be same in order to avoid the under-test in vibration test control. The structural modification of the fixture is needed so that anti-resonance frequencies at attachment points have the same value. In this paper, the method to calculate the anti-resonance frequencies and those sensitivities is presented. This sensitivity analysis is applied to the structural modification of the fixture excited at multi-points by the shaker. The antiresonance frequencies at the attachment points of the fixture can have the same value after structural modification, and the under-test in the vibration test control can be removed. Several computer simulations show that the proposed method can remove the under-tests, which are not removed in conventional vibration test control.

Vibration Control of Tower Structure under Wind Load (풍하중에 의한 타원형 구조물의 진동 제어)

  • Hwang Jae-Seung;Kim Yun-Seok;Joo Seok-Jun
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.427-430
    • /
    • 2002
  • The present parer outlines the system identification and vibration control performance of air traffic control tower of Yangyang international airport with tuned mass damper(TMD). From the free vibration test, natural frequency, damping ratio and mode shape of tower are obtained and these values are compared with the values from numerical analysis. In the vibration control test to evaluate the vibration control performance, equivalent damping ratio increased by tuned mass damper are obtained in case the TMD is operated as passive mode. Damping ratio of tower evaluated from free vibration test is about $1.0{\%}$. It is very low value than damping ratio recommended in general code. Damping ratio of passive mode is about $5{\%}$. These equivalent damping ratio increased by TMD is enough to enhance the serviceability of tower structure under wind load.

  • PDF

Active Control of Structural Vibration Using An Instantaneous Control Algorithm including Acceleration Feedback (가속도가 포함된 순간최적제어 알고리듬을 이용한 구조물 진동의 능동제어)

  • 문석준;정태영
    • Journal of KSNVE
    • /
    • v.6 no.2
    • /
    • pp.215-224
    • /
    • 1996
  • Active vibration control is generally used to reduce vibration level by the actuators based on measured signal. Dynamic properties of a structure can be easily modified by the active vibration control, so that the vibration level may be effectively reduced to the magnitude below the allowable limit over a wide frequency rangs. In this paper, an instantaneous optimal control algorithm including acceleration feedback is presented for the active vibration control of large structures considering facts that the acceleration response can be easily measured, but the displacement and velocity response are obtained by numerically integrating the measured acceleration response with some errors. The adverse effect of the time delay is overcomed by taking into account the dynamic characteristics of an actuator and filters in the design of controller. Performance test is carried out using a hydraulic active mass driver on a test structure$(L{\times}W{\times}H;=;1200mm{\times}800mm{\times}1600mm, about;500kg)$ supported by four columns under base excitations. It is confirmed that the vibration level of the test structure are reduced to about 1/6 near resonance.

  • PDF

Effects of Local Vibration on Knee Joint on Postural Control (슬관절에 대한 국소 진동 적용이 자세 조절 능력에 미치는 영향)

  • Park, Soo-Jin;Bang, Hyun-Soo;Choen, Song-Hee;Kang, Jong-Ho;Kim, Jin-Sang
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.2 no.2
    • /
    • pp.195-203
    • /
    • 2007
  • Purpose : The purpose of this study was to evaluate the effects of local vibration on knee joints on ability of postural control. Methods : The subjects(50) were divided into control group(25) and vibration group(25). Vibration group was given vibration on knee joint for 10 minutes and control group was given resting for 10 minutes. All subjects of each group were tested on MFT balance tester board for 30 seconds and MFT Balance Test English 1.7 was used to measure ability of postural control pre and post test. Results : 1. Laterality didn't have statistically significant difference pre and post test in both groups(p<0.05). 2. In the control group Body stability didn't have significant difference pre and post test(p>0.05), but had significant difference in the vibration group(p<0.05). 3. At assessment Movement of COG, sector2 in the control group and sector 1, 5 in the experimental group had significant difference pre and post test(p<0.05). Conclusion : From this result vibration on knee have an effect on Body stability. Therefore, the vibration will be effective in treatment of patients who have disability of postural control.

  • PDF

Application of Linear Oscillatory Actuator to Active Structural Vibration Control (Linear oscillatory actuator를 이용한 구조물 진동의 능동 제어 연구)

  • 정태영;문석준;정종안;박희창;장석명
    • Journal of KSNVE
    • /
    • v.7 no.2
    • /
    • pp.311-317
    • /
    • 1997
  • In this paper the active vibration control system using a linear oscillatory actuator(LOA) is studied to suppress structural vibration. In the LOA, the AC-power-energized armature generates a shift field in an air gap, which produces a oscillating force to the mover in the magnetic field generated by high density permanent magnets. LOA has relatively simple structure with almost maintenance free, compared with a hydraulic actuator. Performance test of the active vibration control system using a LOA is carried out on a steel test structure under base excitation. From this test, it is confirmed that the acceleration level of the test structure is drastically reduced near the resonant region.

  • PDF

Experimental Structural Dynamic Modification of Fixture for Environmental Vibration Test Control (환경진동시험제어를 위한 치구의 실험적 구조변경 설계)

  • 김준엽;정의봉
    • Journal of KSNVE
    • /
    • v.6 no.3
    • /
    • pp.317-323
    • /
    • 1996
  • This paper proposes the method of experimental structural dynamic modification of fixture for environmental vibration test control. This method can predict the responses at any points on the fixture utilizing the experimental data, and structural dynamic modification of fixture is made using the predicted responses for the spectra at the specimen attachment points to meet the specified reference spectrum. From the results of controlling the fixture before and after modification by conventional control method and optimal reference spectrum, which has been previously reported by the authors, the proposed method is shown to be an effective one.

  • PDF

Structural Dynamic Modification of Fixture by Antiresonance Frequency Analysis in Environmental Vibration Test Control (환경진동시험 제어에서 반공진 진동수해석에 의한 치구의 구조변경설계)

  • 김준엽;정의봉
    • Journal of KSNVE
    • /
    • v.5 no.4
    • /
    • pp.555-563
    • /
    • 1995
  • This paper proposes the method of antiresonance frequency analysis of multi-input multi-output system. The structural dynamic modification techniques by antiresonance frequency analysis are also applied to reduce the undertest at specimen attachment points on the fixture in environmental vibration test, which is resulted from the inconsistency of antiresonance frequencies at any specified points. Several computer simulations show that the proposed method can remove the undertest problem which is not removed in conventional vibration test control. And the effectiveness of the method is verified with the impact hammer excitation of aluminium fixture model.

  • PDF

Vibration Control of Beam using Piezoceramic Composite Actuator LIPCA (압전 복합재료 작동기 LIPCA를 이용한 보의 진동 제어)

  • Arief, Suhariyono;Goo, Nam-Seo;Park, hoon-Cheol;Yoon, Kwang-Joon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.8 no.4 s.23
    • /
    • pp.130-135
    • /
    • 2005
  • This paper presents application possibility of Lightweight Piezoceramic Composite Actuator(LIPCA) to suppress vibration of dynamic structures as an actuator. LIPCA is composed of a piezoelectric layer, a carbon/epoxy layer and glass/epoxy layers. When compared to the bare piezoelectric ceramic(PZT), LIPCA has advantages such as high performance, durability and reliability. In this study, performances of LIPCA have been estimated in an active vibration control system. Experiments were performed on an aluminum beam with cantilever configuration. In this test, strain gages and single LIPCA are attached on the aluminum beam with epoxy resin. Digital ON-OFF control algorithm is applied into the system to exhibit performance of LIPCA as actuator in active vibration control system. First, we performed static actuation test of bare PZT and LIPCA in order to show the superiority of LIPCA. Secondly, we carried out beam vibration control test using LIPCA. The results showed LIPCA could suppress free vibration of the aluminum beam, which means that LIPCA can be applied as an actuator to control vibration of dynamic structures.

Application of Linear Oscillatory Actuator to Active Structural Vibration Control (Linear Oscillatory Actuator를 이용한 구조물 진동의 능동제어연구)

  • 정태영;문석준;정종안;박희창;장석명
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.10a
    • /
    • pp.248-254
    • /
    • 1996
  • In this paper active vibration control system using a linear oscillatory actuator (LOA) is studied to suppress structural vibration. Being compared with a hydraulic actuator, a LOA has simplified structure and requires a few elements, so it has lots of merits with respect to economics and maintenance. Performance test of active vibration control system using LOA is carried out on a steel test structure under base excitation. From this test it is confirmed that acceleration level of test structure is reduced near the resonance region. In the future research on the application to large to structures will be studied.

  • PDF

Full-scale experimental verification on the vibration control of stay cable using optimally tuned MR damper

  • Huang, Hongwei;Liu, Jiangyun;Sun, Limin
    • Smart Structures and Systems
    • /
    • v.16 no.6
    • /
    • pp.1003-1021
    • /
    • 2015
  • MR dampers have been proposed for the control of cable vibration of cable-stayed bridge in recent years due to their high performance and low energy consumption. However, the highly nonlinear feature of MR dampers makes them difficult to be designed with efficient semi-active control algorithms. Simulation study has previously been carried out on the cable-MR damper system using a semi-active control algorithm derived based on the universal design curve of dampers and a bilinear mechanical model of the MR damper. This paper aims to verify the effectiveness of the MR damper for mitigating cable vibration through a full-scale experimental test, using the same semi-active control strategy as in the simulation study. A long stay cable fabricated for a real bridge was set-up with the MR damper installed. The cable was excited under both free and forced vibrations. Different test scenarios were considered where the MR damper was tuned as passive damper with minimum or maximum input current, or the input current of the damper was changed according to the proposed semi-active control algorithm. The effectiveness of the MR damper for controlling the cable vibration was assessed through computing the damping ratio of the cable for free vibration and the root mean square value of acceleration of the cable for forced vibration.