• 제목/요약/키워드: Vibration Amplitude

검색결과 1,046건 처리시간 0.026초

전기자극 변조방식이 체성감각에 미치는 영향 (Effects of Modulation Type on Electrically-Elicited Tactile Sensation)

  • 황선희;아라 조샨;송동진;배태수;박상혁;강곤
    • 한국정밀공학회지
    • /
    • 제29권7호
    • /
    • pp.711-716
    • /
    • 2012
  • The purpose of this study was to investigate how the modulation method affects the effectiveness of eliciting tactile sensations by electrical stimulation. Two methods were employed and the results were compared and analyzed; pulse amplitude modulation (PAM) and pulse width modulation (PWM). Thirty-five healthy subjects participated in the experiments to measure the stimulation intensity that began to elicit a tactile sensation - activation threshold (AT). Constant-current monophasic rectangular pulse trains were employed, and the stimulation intensity was varied from zero until the subject felt any uncomfortable sensation. The step size of the stimulation intensity was 100nC/pulse. After each experiment, the subject described the sensation both quantitatively and qualitatively. The two modulation methods did not make a significant difference as far as the AT values were concerned, but most of the subjects showed 'intra-individual' consistency. Also, it was confirmed that our range of the stimulation parameters enabled us to obtain three major tactile sensations; tickling, pressure and vibration. The results suggested that the stimulation parameters and the modulation type should be selected for each individual and that selective electrical stimulation of the mechanoreceptors needs more diversified researches on the electrode design, multi-channel stimulation protocol, waveforms of the pulse train, etc.

Beam Shaping and Speckle Reduction in Laser Projection Display Systems Using a Vibrating Diffractive Optical Element

  • Liang, Chuanyang;Zhang, Wei;Wu, Zhihui;Rui, Dawei;Sui, Yongxin;Yang, Huaijiang
    • Current Optics and Photonics
    • /
    • 제1권1호
    • /
    • pp.23-28
    • /
    • 2017
  • The laser has been regarded as the potential illumination source for the next generation of projectors. However, currently the major issues in applying the laser as an illumination source for projectors are beam shaping and laser speckle. We present a compact solution for both issues by using a vibrating diffractive optical element (DOE). The DOE is designed and fabricated, and it successfully transforms the circular Gaussian laser beam to a low speckle contrast uniform rectangular pattern. Under a vibration frequency of 150 Hz and amplitude of $200{\mu}m$, the speckle contrast value is reduced from 67.67% to 13.78%, and the ANSI uniformity is improved from 24.36% to 85.54%. The experimental results demonstrate the feasibility and potential of the proposed scheme, and the proposed method is a feasible approach to the miniaturization of laser projection display illumination systems.

Effectiveness of whole body vibratory stimulation for fall prevention in super-aged women: a preliminary randomized trial

  • Kim, Byeong-Soo;Lim, Kang-Uk;Baek, In-Seon;Kim, Min-Kyoung;Kang, Hye-Min;Nam, Gi-Jeong;Lee, Myung-Mo
    • Physical Therapy Rehabilitation Science
    • /
    • 제8권1호
    • /
    • pp.32-39
    • /
    • 2019
  • Objective: The aim of this study is to investigate the effects of whole body vibratory stimulation on muscle strength, balance, and fall efficacy among super-aged women. Design: Randomized controlled trial. Methods: Twenty-eight super-aged women over 80 years of age were assigned to either the experimental group (n=14) and control group (n=14). The experimental group received an exercise program that used the whole body vibratory stimulation with a frequency of 30 Hz and amplitude of 3 mm, and the control group received an exercise program without vibratory stimulation. Intervention was provided for 4 weeks, 3 sessions per week, and 30 minutes per session. In order to measure lower extremity muscle strength the 30-second chair stand test (CST) was used. The Berg Balance Scale (BBS) was used to measure dynamic balance. Static balance was measured by tracking the path length, velocity, and area of the center of pressure (CoP). The Falls Efficacy Scale (FES) was used to measure the subjects' fear of falling. Results: Both the experimental and control group demonstrated statistically significant increase in muscle strength, dynamic balance, and fall efficacy (p<0.05). Only the experimental group showed significant improvements in static balance before and after the intervention (p<0.05). The experimental group showed significantly greater improvements in CST, BBS, and CoP (path length, velocity) than control group (p<0.05). Conclusions: Whole body vibratory stimulation exercise is shown to be a safe and appropriate physical therapy intervention method to enhance muscle strength, balance, and fall efficacy of super-aged women.

Numerical simulation in time domain to study cross-flow VIV of catenary riser subject to vessel motion-induced oscillatory current

  • Liu, Kun;Wang, Kunpeng;Wang, Yihui;Li, Yulong
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제12권1호
    • /
    • pp.491-500
    • /
    • 2020
  • The present study proposes a time domain model for the Vortex-induced Vibration (VIV) simulation of a catenary riser under the combination of the current and oscillatory flow induced by vessel motion. In this model, the hydrodynamic force of VIV comprises excitation force, hydrodynamic damping and added mass, which are taken as functions of the non-dimensional frequency and amplitude ratio. The non-dimensional frequency is related with the response frequency, natural frequency, lock-in range and the fluid velocity. The relatively oscillatory flow induced by vessel motion is taken into account in the fluid velocity. Considering that the added mass coefficient and the non-dimensional frequency can affect each other, an iterative analysis is conducted at each time step to update the added mass coefficient and the natural frequency. This model is in detail validated against the published test models. The results show that the model can reasonably reflect the effect of the added mass coefficient on the VIV, and can well predict the riser's VIV under stationary and oscillatory flow induced by vessel motion. Based on the model, this study carries out the VIV simulation of a catenary riser with harmonic vessel motion. By analyzing the bending moment near the touchdown point, it is found that under the combination of the ocean current and oscillatory flow the vessel motion may decrease the VIV response, while increase the excited frequencies. In addition, the decreasing rate of the VIV under vessel surge is larger than that under vessel heave at small vessel motion velocity, while the situation becomes opposite at large vessel motion velocity.

Investigation of 0.5 MJ superconducting energy storage system by acoustic emission method.

  • Miklyaev, S.M.;Shevchenko, S.A.;Surin, M.I.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.961-965
    • /
    • 1998
  • The rapid development of small-scale (1-10 MJ) Superconducting Magnetic Energy Storage Systems (SMES) can be explained by real perspective of practical implementation of these devices in electro power nets. However the serious problem of all high mechanically stressed superconducting coils-problem of training and degradation (decreasing) of operating current still exists. Moreover for SMES systems this problems is more dangerous because of pulsed origin of mechanical stresses-one of the major sources of local heat disturbances in superconducting coils. We investigated acoustic emission (AE) phenomenon on model and 0.5 MJ SMES coils taking into account close correlation of AE and local heat disturbances. Two-coils 0.5 MJ SMES system was developed, manufactured and tested at Russian Research Center in the frames of cooperation with Korean Electrical Engineering Company (KEPCO) [1]. The two-coil SMES operates with the stored energy transmitted between coils in the course of a single cycle with 2 seconds energy transfer time. Maximum operating current 1.55 kA corresponds to 0.5 MF in each coil. The Nb-Ti-based conductor was designed and used for SMES manufacturing. It represents transposed cable made of Nb-Ti strands in copper matrix, several cooper strands and several stainless steel strands. The coils are wound onto fiberglass cylindrical bobbins. To make AE event information more useful a real time instrumentation system was used. Two main measured and computer processed AE parameters were considered: the energy of AE events (E) and the accumulated energy of AE events (E ). Influence of current value in 0.5 MJ coils on E and E was studied. The sensors were installed onto the bobbin and the external surface of magnets. Three levels of initial current were examined: 600A, 1000A, 2450 A. An extraordinary strong dependence of the current level on E and E was observed. The specific features of AE from model coils, operated in sinusoidal vibration current changing mode were investigated. Three current frequency modes were examined: 0.012 Hz, 0.03 Hz and 0.12 Hz. In all modes maximum amplitude 1200 A was realized.

  • PDF

High-rate Single-Frequency Precise Point Positioning (SF-PPP) in the detection of structural displacements and ground motions

  • Mert Bezcioglu;Cemal Ozer Yigit;Ahmet Anil Dindar;Ahmed El-Mowafy;Kan Wang
    • Structural Engineering and Mechanics
    • /
    • 제89권6호
    • /
    • pp.589-599
    • /
    • 2024
  • This study presents the usability of the high-rate single-frequency Precise Point Positioning (SF-PPP) technique based on 20 Hz Global Positioning Systems (GPS)-only observations in detecting dynamic motions. SF-PPP solutions were obtained from post-mission and real-time GNSS corrections. These include the International GNSS Service (IGS)-Final, IGS real-time (RT), real-time MADOCA (Multi-GNSS Advanced Demonstration tool for Orbit and Clock Analysis), and real-time products from the Australian/New Zealand satellite-based augmentation systems (SBAS, known as SouthPAN). SF-PPP results were compared with LVDT (Linear Variable Differential Transformer) sensor and single-frequency relative positioning (SF-RP) solutions. The findings show that the SF-PPP technique successfully detects the harmonic motions, and the real-time products-based PPP solutions were as accurate as the final post-mission products. In the frequency domain, all GNSS-based methods evaluated in this contribution correctly detect the dominant frequency of short-term harmonic oscillations, while the differences in the amplitude values corresponding to the peak frequency do not exceed 1.1 mm. However, evaluations in the time domain show that SF-PPP needs high-pass filtering to detect accurate displacement since SF-PPP solutions include trends and low-frequency fluctuations, mainly due to atmospheric effects. Findings obtained in the time domain indicate that final, real-time, and MADOCA-based PPP results capture short-term dynamic behaviors with an accuracy ranging from 3.4 mm to 8.5 mm, and SBAS-based PPP solutions have several times higher RMSE values compared to other methods. However, after high-pass filtering, the accuracies obtained from PPP methods decreased to a few mm. The outcomes demonstrate the potential of the high-rate SF-PPP method to reliably monitor structural and earthquake-induced ground motions and vibration frequencies of structures.

능동 조임 마찰 가새로 보강한 단자유도 구조물의 응답 (Vibration Control for a Single Degree of Freedom Structure Using Active Friction Slip Braces)

  • 이진호;아크베이-제카이;김정길;오상균
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제10권1호
    • /
    • pp.131-138
    • /
    • 2006
  • 일정한 크기의 마찰력을 도입한 가새(FSB)는 에너지를 소산시키는 효과적인 구조 부재이며, 가새의 축력이 마찰력을 넘지 않을 때까지만 탄성 거동을 한다. 본 연구에서는 FSB 개념을 보다 확장시켜서 가새를 죄는 마찰력의 크기를 능동적으로 변화시킬 수 있는 능동 조임 마찰 가새(AFSB)를 착상하여 단자유도 구조물에 적용하고 조화 하중으로 기진시켜 그 거동을 시뮬레이션 하여 FSB와 비교 분석해본다. 이를 위해 간단하고 효과적인 알고리즘을 개발해보았다. 연구 결과, 지반 가속도 값이 그다지 크지 않은 경우, AFSB는 초기에 오우버슈팅이 발생하는 문제만 제외하고 FSB에 비해 효과적으로 진폭과 밑면 전단력을 감소시켰다.

Mechanical performance analysis of an electromagnetic friction pendulum system based on Maxwell's principle

  • Mao Weikang;Li Xiaodong;Chen Enliang
    • Earthquakes and Structures
    • /
    • 제27권2호
    • /
    • pp.143-154
    • /
    • 2024
  • Friction pendulums typically suffer from poor uplift-restraining. To improve the uplift-restraining and enhance the energy dissipation capacity, this article proposed a composite isolation device based on electromagnetic forces. The device was constructed based on a remote control system to achieve semi-active control of the composite isolation device. This article introduces the theory and design of an electromagnetic chuck-friction pendulum system (ECFPS) and derives the theoretical equation for the ECFPS based on Maxwell's electromagnetic attraction equation to construct the proposed model. By conducting 1:3 scale tests on the electromagnetic device, the gaps between the practical, theoretical, and simulation results were analyzed, and the accuracy and effectiveness of the theoretical equation for the ECFPS were investigated. The hysteresis and uplift-restraining performance of ECFPS were analyzed by adjusting the displacement amplitude, vertical load, and input current of the simulation model. The data obtained from the scale test were consistent with the theoretical and simulated data. Notably, the hysteresis area of the ECFPS was 35.11% larger than that of a conventional friction pendulum. Lastly, a six-story planar frame structure was established through SAP2000 for a time history analysis. The isolation performances of ECFPS and FPS were compared. The results revealed that, under horizontal seismic action, the horizontal seismic response of the bottom layer of the ECFPS isolation structure is greater than that of the FPS, the horizontal vibration response of the top layer of the ECFPS isolation structure is smaller than that of the FPS, and the axial force at the bottom of the columns of the ECFPS isolation structure is smaller than that of the FPS isolation structure. Therefore, the reliable uplift-restraining performance is facilitated by the electromagnetic force generated by the device.

탈접착 후처치시 핸드피스(handpiece) 속도가 치아에 미치는 영향에 대한 비교 연구 (A comparison study of the effects of handpiece speed on teeth in debonding procedure)

  • 박수병;김구호;하만희
    • 대한치과교정학회지
    • /
    • 제34권1호
    • /
    • pp.83-91
    • /
    • 2004
  • 본 연구는 탈접착 후처치시 사용된 핸드피스(handpiece)속도에 따른 처치 효율성과 환자 불편감 정도를 알아보기 위하여 시행되었다. 발거된 소구치(50개)에 브라켓을 접착하고 제거한 후 tungsten carbide bur를 장착한 저속 핸드피스와 ultra-fine diamond finishing bur를 장착한 고속 핸드피스로 각각 25개씩 탈접착 후처치를 시행했으며, 이때 각 실험군내 치아의 진동정도와 치수강내 온도 변화를 측정하였다. 이후 각 실험군(저속, 고속 핸드피스군)에서 임으로 10개씩의 치아를 선택하여 주사전자현미경으로 법랑질 표면에 대한 평가를 시행하여, 다음과 같은 결론을 얻었다. 1. 저속 핸드피스를 사용한 레진 제거시 다양한 진폭의 치아 진동이 고속 핸드피스를 이용한 경우보다 많이 나타났다. 2. 고속 핸드피스를 이용한 경우의 치수강내 온도변화가 저속 핸드피스를 사용한 경우보다 유의성 있게 높았으며, 레진 제거 시간 역시 두 배정도 길게 걸렸다. 3. 레진 제거 후 법랑질 표면에 대한 주사전자현미경상은 고속 핸드피스를 사용한 경우에서 절흔들(notches)과 잔여레진들이 저속 핸드피스를 사용한 경우보다 많은 것을 보여주었다.

전기성문파형검사를 이용한 모음과 공명 자음의 발성특성 (Phonatory Caracteristics of Vwels and Resonant Consonants using the Electroglottography)

  • 최성희;남도현;임재열;임성은;최홍식
    • 대한후두음성언어의학회지
    • /
    • 제15권2호
    • /
    • pp.133-140
    • /
    • 2004
  • Background and Objectives : Vowels and resonant including nasals and liquid are produced with vocal folds vibration have been used for voice therapy of hyperadduction patients. This study was conducted to investigate phonatory characteristics of vowels and resonant consonants through the EGG measures from Lx. Speech studio (Laryngograph Ltd, UK). Materials and Method : 7 male adults produced sustained vowel /a/, /i/, /u/, nasals /m/, /n/, /${\eta}$/and liquid /I/ and read the sentences (1nasals-liquid sentence, 1 non-nasals-liquid sentence) and tongue-tip trill and humming. Fx(Hz), Ox(%) were obtained of vowels, nasals, liquid and each of the posterior vowel /a/ of /ma/, /na/, /la/, /ha/ with same F0(around F#165Hz) and amplitude (75${\pm}$5db). And also DFx(Hz), DQx(%), CFx(%) and CAx(%) were obtained from reading two kinds of sentences. Results : Qx(%) was the highest in /u/ of vowels, and nasal/n/ of the resonant consonants and nasals-liquid sentence was higher Qx than non-nasals-liquid sentence but significant differences were not found. Qx(%) of the posterior vowel /a/ of nasal consonants/n/ was higher than in the isolated vowel/a/ and other posterior vowel of resonant consonants and fricatives /h/. Regularity or periodicity and higher Qx were observed in the nasals-liquid sentence than non-nasals-liquid sentence in graphs of QxFx & CFx produced by Quantiative analysis. In the nasalance score, /u/vowel was significant higher among the vowels and /I/ liquid was significant lower among the resonant consonants and nasals-liquid sentence is higher than non-nasals -liquid sentence. CQ(%) was not significantly correlated with nasalance(%). Conclusion : These findings might signify resonant phonation was not correlated with nasalance.

  • PDF